SARS-CoV-2 and the ocular surface: test accuracy and viral load

SARS-CoV-2 e a superfície ocular: acurácia dos testes e carga viral

ABSTRACT

Purpose:

This study aimed to evaluate the pre-sence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) RNA in the ocular surface of individuals clinically suspected of coronavirus disease 2019 (COVID-19) and determine the accuracy of different approaches of molecular testing on the ocular surface based on the nasopharyngeal positivity status for COVID-19.

Methods:

A total of 152 individuals with suspected COVID-19 symptoms who simultaneously underwent nasopharyngeal and two different tear film collection techniques for quantitative reverse-transcriptase polymerase chain reaction (RT-qPCR) were included. Tears were collected and randomized: one eye had the filter strip for the Schirmer test and the contralateral eye had conjunctival swab/cytology in the inferior fornix. All patients underwent slit lamp biomicroscopy. The accuracy of various ocular surface collection techniques used for the detection of SARS-CoV-2 RNA was determined.

Results:

Of the 152 patients enrolled in the study, 86 (56.6%) had COVID-19 confirmed by nasopharyngeal PCR. Both tear film collection techniques detected viral particles: the Schirmer test was positive in 16.3% (14/86) and the conjunctival swab/cytology in 17.4% (15/86), with no statistically significant differences. No positive ocular tests were found among those with negative nasopharyngeal PCR tests. The overall agreement of the ocular tests was 92.7%, and in combination, the sensitivity would increase to 23.2%. The mean cycle threshold values in the nasopharyngeal, Schirmer, and conjunctival swab/cytology tests were 18.2 ± 5.3, 35.6 ± 1.4, and 36.4 ± 3.9, respectively. Compared with the nasopharyngeal test, the Schirmer (p=0.001) and conjunctival swab/cytology (p<0.001) tests had significantly different Ct values.

Conclusion:

The Schirmer (16.3%) and conjunctival swab (17.4%) tests were comparably capable of detecting SARS-CoV-2 RNA in the ocular surface by RT-PCR accurately based on nasopharyngeal status and demonstrated indistinct sensitivity and specificity. Simultaneous specimen sampling and processing from the nasopharyngeal, Schirmer, and conjunctival swab/cytology tests demonstrated significantly lower viral load in both ocular surface approaches than in the nasopharyngeal test. Ocular manifestations detected by slit lamp biomicroscopy were not associated with ocular RT-PCR positivity.

Keywords:
COVID-19; SARS-CoV-2; Conjunctiva; Tears; Reverse transcriptase polymerase chain reaction; RNA; viral