Acessibilidade / Reportar erro

Evoked potencial by median nerve stimulation: comparison of central conduction time defined by different measuring points

After stimulation of the right median nerve in 20 normal adult volunteers interpeak latency N13-N20 and the difference in onset latency of the components N11-N20 are compared. A fractionation of the last measure was made at the onset of the P13-14 complex. The results concur with the ones in the literature, and it has been observed that all points measured could be obtained without significant difference on the C6-FZ and P3-FZ montages.

evoked potentials; somatosensory; median nerve; central conduction time


Academia Brasileira de Neurologia - ABNEURO R. Vergueiro, 1353 sl.1404 - Ed. Top Towers Offices Torre Norte, 04101-000 São Paulo SP Brazil, Tel.: +55 11 5084-9463 | +55 11 5083-3876 - São Paulo - SP - Brazil
E-mail: revista.arquivos@abneuro.org