Acessibilidade / Reportar erro
Brazilian Dental Journal, Volume: 22, Número: 3, Publicado: 2011
  • Oxidative nanopatterning of titanium surfaces promotes production and extracellular accumulation of osteopontin

    Bueno, Renan de Barros e Lima; Adachi, Patricia; Castro-Raucci, Larissa Moreira Spinola de; Rosa, Adalberto Luiz; Nanci, Antonio; Oliveira, Paulo Tambasco de

    Resumo em Português:

    A interface osso-implante é caracterizada pela presença de uma camada de matriz extracellular (MEC) afibrilar rica em proteínas não-colágenas, incluindo osteopontina (OPN), cujas funções no tecido ósseo estão relacionadas à adesão celular e ao controle do processo de mineralização da MEC (crescimento de cristais). Aspectos físicos e químicos das superfícies de biomateriais podem afetar as interações célula-MEC-substrato. O objetivo do presente estudo foi demonstrar a capacidade de aspectos nanotopográficos de superfície de titânio (Ti) de controlar a deposição extracelular de OPN in vitro. Discos de Ti foram tratados quimicamente por solução de H2SO4/H2O2 durante 30 min [Nano(30') Ti] ou 4 h [Nano(4h) Ti]. Superfícies de Ti não tratadas foram usadas como controle. Células osteogênicas primárias derivadas de calvárias de ratos recém-nascidos foram plaqueadas sobre os discos de Ti e cultivadas em condições osteogênicas por até 7 dias. Microscopia eletrônica de varredura de alta resolução revelou que os discos de Ti tratados quimicamente exibiam superfície nanoporosa, com áreas de nanoporos maiores para Nano(4h) Ti. Apenas para esse grupo detectavam-se acúmulos extensos de OPN extracelular, os quais se distribuíam em áreas adjacentes a células OPN-positivas, com aspectos morfológicos típicos de células em migração. Em conclusão, a nanoestruturação química de superfície de Ti pode favorecer o aumento da deposição extracelular de OPN endógena por células osteogênicas in vitro, dependendo do tempo de condicionamento utilizado, o que deve ser considerado no desenvolvimento de estratégias para funcionalizar superfícies de implantes com moléculas com reconhecido efeito no processo de adesão celular.

    Resumo em Inglês:

    The bone-biomaterial interface has been characterized by layers of afibrillar extracellular matrix (ECM) enriched in non collagenous proteins, including osteopontin (OPN), a multifunctional protein that in bone controls cell adhesion and ECM mineralization. Physical and chemical aspects of biomaterial surfaces have been demonstrated to affect cell-ECM-substrate interactions. The present paper described the ability of oxidative nanopatterning of titanium (Ti) surfaces to control extracellular OPN deposition in vitro. Ti discs were chemically treated by a mixture of H2SO4/H2O2 for either 30 min [Nano(30') Ti] or 4 h [Nano(4h) Ti]. Non-etched Ti discs were used as control. Primary osteogenic cells derived from newborn rat calvarial bone were plated on control and etched Ti and grown under osteogenic conditions up to 7 days. High resolution scanning electron microscopy revealed that treated Ti discs exhibited a nanoporous surface and that areas of larger nanopits were noticed only for Nano(4h) Ti. Large extracellular OPN accumulation were detectable only for Nano(4h) Ti, which was associated with OPN-positive cells with typical aspects of migrating cells. At day 3, quantitative results in terms of areas of OPN labeling were as follows: Nano(4h) Ti > Nano(30') Ti > Control Ti. In conclusion, chemically nanostructured Ti surfaces may support the enhancement of endogenous extracellular OPN deposition by osteogenic cells in vitro depending on the etching time, a finding that should be taken into consideration in strategies to biofunctionalize implant surfaces with molecules with cell adhesion capacity.
  • Effect of instrumentation using curettes, piezoelectric ultrasonic scaler and Er,Cr:YSGG laser on the morphology and adhesion of blood components on root surfaces: a SEM study

    Tsurumaki, Jackeline do Nascimento; Souto, Bráulio Henrique Marques; Oliveira, Guilherme José Pimentel Lopes de; Sampaio, José Eduardo Cézar; Marcantonio Júnior, Elcio; Marcantonio, Rosemary Adriana Chiérici

    Resumo em Português:

    Esse estudo utilizou microscopia eletrônica de varredura (MEV) para avaliar a morfologia e a adesão de elementos sanguíneos em superfícies radiculares instrumentadas com curetas, ultrassom piezoelétrico e laser de Er,Cr:YSGG. Foram utilizadas no presente estudo 100 amostras provenientes de 25 dentes que foram divididas em 5 grupos: 1) Raspagem manual com curetas; 2) Raspagem com ultrassom; 3) Associação instrumento manual e ultrassom; 4)Irradiação do laser de Er,Cr:YSGG;5)Associação raspagem manual com irradiação com laser de Er,Cr:YSGG. Dez amostras de cada grupo foram utilizadas para análise da morfologia e as outras 10 foram utilizadas para a análise de adesão de elementos sanguíneos. As eletromicrografias foram analisadas através dos escores de adesão de elementos sanguíneos e pelo índice de morfologia radicular e os resultados foram analisados estatisticamente através dos testes de Kruskall-Wallis e de Mann-Whitney com nível de significância de 5%. O grupo que foi tratado com instrumentos manuais apresentou superfície mais lisa em relação aos grupos que foram instrumentados com ultrassom e com o laser de Er,Cr:YSGG. As superfícies instrumentadas com ultrassom e com o laser de Er,Cr:YSGG de forma isolada ou associada a raspagem manual não apresentaram diferenças estatísticas entre si (p>0,05). Não houve diferenças estatísticas entre os grupos em relação a adesão de elementos sanguíneos(p>0,05). A instrumentação ultrassônica e a irradiação com o laser de Er,Cr:YSGG produziram superfícies radiculares mais rugosas em relação a raspagem com curetas, porém não houve diferenças entre os tratamentos com relação à adesão de elementos sanguíneos.

    Resumo em Inglês:

    This study used scanning electron microscopy (SEM) to evaluate the morphology and adhesion of blood components on root surfaces instrumented by curettes, piezoelectric ultrasonic scaler and Er,Cr:YSGG laser. One hundred samples from 25 teeth were divided into 5 groups: 1) Curettes; 2) Piezoelectric ultrasonic scaler; 3) Curettes plus piezoelectric ultrasonic scaler; 4) Er,Cr:YSGG laser; 5) Curettes plus Er,Cr:YSGG laser. Ten samples from each group were used for analysis of root morphology and the other 10 were used for analysis of adhesion of blood components on root surface. The results were analyzed statistically by the Kruskall-Wallis and Mann-Whitney tests with a significance level of 5%. The group treated with curettes showed smoother surfaces when compared to the groups were instrumented with piezoelectric ultrasonic scaler and the Er,Cr:YSGG laser. The surfaces instrumented with piezoelectric ultrasonic scaler and Er,Cr:YSGG laser, alone or in combination with hand scaling and root planing, did not differ significantly (p>0.05) among themselves. No statistically significant differences (p>0.05) among groups were found as to the adhesion of blood components on root surface. Ultrasonic instrumentation and Er,Cr:YSGG irradiation produced rougher root surfaces than the use of curettes, but there were no differences among treatments with respect to the adhesion of blood components.
  • Therapeutic potential of Brazilian fluoride varnishes: an in vivo study

    Almeida, Marcella Quirino de; Costa, Olívia Ximenes Izidro; Ferreira, Jainara Maria Soares; Menezes, Valdenice Aparecida de; Leal, Rossana Barbosa; Sampaio, Fábio Correia

    Resumo em Português:

    O propósito do presente estudo foi avaliar in vivo o efeito terapêutico de 3 vernizes fluoretados disponíveis no mercado brasileiro em lesões de mancha branca (MB). A amostra foi composta de 36 crianças entre 7 e 13 anos, portadoras de 67 MB ativas em elementos dentários permanentes anteriores. As crianças foram divididas aleatoriamente em 3 grupos FL - Fluorniz (n=24), DUO - Duofluorid XII (n=22) e DF - Durafluor (n=21). A dimensão máxima da MB (mésio-distal e cérvico-incisal) foi mensurada em milímetros por um único examinador previamente calibrado através de uma sonda periodontal. Em adição, foi verificada a atividade da MB. O IHO-S (Índice de Higiene Oral Simplificado) inicial e final foi registrado. O teste do qui-quadrado de Pearson mostrou não existir diferença estatisticamente significante (p>0,05) no comportamento dos vernizes estudados. No final da 5ª semana o FL apresentava 6 MB ativas e 18 inativas, DUO 7 MB ativas e 15 inativas e DF 6 MB ativas e 15 inativas. Levando em consideração o grupo total, houve uma redução de 45,7% da dimensão das manchas brancas. O teste T pareado revelou uma diferença estatisticamente significante (p<0,05) entre o tamanho inicial (1,88) e final (1,02). Após 4 aplicações, todos os vernizes apresentaram resultados clínicos semelhantes.

    Resumo em Inglês:

    The aim of this study was to assess in vivo the therapeutic effect of three fluoride varnishes available in the Brazilian market on the performance of white spot lesions (WSL). The sample included 36 children aged 7 to 13 years old, with a total of 67 active WSL in permanent anterior teeth. The children were randomly divided into 3 groups, according to fluoride varnish used: FL- Fluorniz (n=24), DUO - Duofluorid XII (n=22) and DF - Durafluor (n=21). Maximum WSL dimensions (mesiodistal and incisogingival) were measured in millimeters by a previously calibrated single examiner using a periodontal probe. WSL were also assessed regarding lesion activity. Initial and final S-OHI (Simplified Oral Hygiene Index) scores were recorded. Pearson's chi-square test revealed no statistically significant differences (p>0.05) in the performance of the varnishes. At the end of the 5th week, FL had 6 active and 18 inactive WSL; DUO had 7 active and 15 inactive WSL; and DL had 6 active and 15 inactive WSL. Taking into account all lesions, there was a 45.7% reduction in WSL dimensions. Paired Student's t-test revealed a statistically significant difference (p<0.05) between the initial size (1.88) and final size (1.02). After four applications, all varnishes obtained similar clinical results.
  • Effect of iron gel on dentin permeability

    Sales-Peres, Sílvia Helena de Carvalho; Reinato, João Victor Donazan; Sales-Peres, André de Carvalho; Marsicano, Juliane Avansini

    Resumo em Português:

    Este estudo objetivou avaliar in vitro o efeito do gel experimental contendo ferro na redução da condutividade hidráulica na dentina. Trinta e seis discos de dentina humana de 1 mm de espessura, foram obtidos de terceiros molares extraídos divididos em 3 grupos de 10 espécimes cada. Os grupos foram divididos nos seguintes grupos experimentais: F- flúor gel a 1,23%, pH 4,1; O- gel de oxalato de potássio a 3%, pH 4,1; I- gel de sulfato ferroso FeSO4 a 10 mmol/L, pH 4,1. Os géis foram aplicados na dentina sob as diferentes condições: após o ácido fosfórico a 37% a antes do ácido cítrico a 6%. Os resultados foram analisados por ANOVA e teste de Tukey, com nível de significância de 5%. Todos os grupos (gel de flúor, oxalato de potássio e gel de ferro) não apresentaram diferenças significativas entre si para todas as condições testadas, exceto na presença da smear layer (p<0,05). Os produtos utilizados reduziram a permeabilidade dentinária, entretanto apresentaram baixa redução quando comparados à smear layer (p<0,05). Não houve diferença significativa na efetividade dos géis testados para reduzir a permeabilidade dentinária (p<0,05). Este estudo sugere que o gel de ferro promoveu redução na permeabilidade dentinária comparável à dos outros agentes e, portanto, pode ser considerada uma boa alternativa clínica para o tratamento da hipersensibilidade dentinária.

    Resumo em Inglês:

    This study evaluated in vitro the effect of an experimental gel containing iron on the reduction of hydraulic conductance of dentin. Thirty-six 1-mm-thick dentin discs obtained from extracted human third molars were divided into 3 groups of 10 specimens each. The groups corresponded to the following experimental materials: 1.23% acidulated phosphate fluoride gel, pH 4.1; 3% potassium oxalate gel, pH 4.1 (Oxa-Gel®); and iron sulfate gel (10 mmol/L FeSO4), pH 4.1. The gels were applied to dentin under the following conditions: after 37% phosphoric acid and before 6% citric acid. Data were analyzed statistically by ANOVA and Tukey's test at 5% significance level. There was no significant differences (p<0.05) among the groups in any of the conditions for hydraulic conductance reduction, except for smear layer presence. The active agents reduced dentin permeability, but they produced significantly lower (p<0.05) reduction in hydraulic conductance when compared to presence of smear layer. The effectiveness in reducing dentin permeability was not significantly different (p>0.05) among the gels. This study suggests that the iron gel promoted reduction in dentin permeability comparable to that of the other agents and thus may be considered a good clinical alternative for the treatment of dentin hypersensitivity.
  • Subcutaneous connective tissue response to primary root canal filling materials

    Queiroz, Alexandra Mussolino de; Assed, Sada; Consolaro, Alberto; Nelson-Filho, Paulo; Leonardo, Mario Roberto; Silva, Raquel Assed Bezerra; Silva, Lea Assed Bezerra

    Resumo em Português:

    Neste estudo avaliou-se a resposta do tecido conjuntivo subcutâneo de camundongos BALB/c a materiais obturadores de canal radicular de dentes decíduos: óxido de zinco/eugenol (OZE), pasta Calen® espessada com óxido de zinco (Calen/OZ) e cimento Sealapex®. Os camundongos (n=102) receberam implantes de tubos de polietileno??? e foram divididos em grupos: I, II, III - Calen/OZ (7, 21 e 63 dias, respectivamente); IV, V, VI - Sealapex (7, 21 e 63 dias, respectivamente); VII, VIII, IX - OZE (7, 21 e 63 dias, respectivamente); X, XI - tubo vazio (7 e 21 dias, respectivamente). Os tecidos foram submetidos ao processamento e análise histopatológica descritiva e por meio de escores do fibrosamento, espessura tecidual e infiltrado inflamatório. Para a análise quantitativa mensurou-se a área e a espessura do tecido granulomatoso reacional (TGR). Os resultados foram analisados pelos testes de Kruskal-Wallis, ANOVA e pós-teste de Tukey (?=0,05). Não houve diferença significante (p>0,05) entre os materiais, com relação ao fibrosamento e à espessura do TGR. Contudo, Calen/OZ apresentou infiltrado inflamatório de menor intensidade (p<0,05). A área do TGR foi menor (p<0,05) para Calen/OZ e Sealapex. Pôde-se concluir que Calen/OZ foi o material que apresentou a melhor compatibilidade tecidual, seguido pelos cimentos Sealapex e OZE.

    Resumo em Inglês:

    This study evaluated the response of the subcutaneous connective tissue of BALB/c mice to root filling materials indicated for primary teeth: zinc oxide/eugenol cement (ZOE), Calen paste thickened with zinc oxide (Calen/ZO) and Sealapex sealer. The mice (n=102) received polyethylene tube implants with the materials, thereby forming 11 groups, as follows: I, II, III: Calen/ZO for 7, 21 and 63 days, respectively; IV, V, VI: Sealapex for 7, 21 and 63 days, respectively; VII, VIII, IX: ZOE for 7, 21 and 63 days, respectively; X and XI: empty tube for 7 and 21 days, respectively. The biopsied tissues were submitted to histological analysis (descriptive analysis and semi-quantitative analysis using a scoring system for collagen fiber formation, tissue thickness and inflammatory infiltrate). A quantitative analysis was performed by measuring the area and thickness of the granulomatous reactionary tissue (GRT). Data were analyzed by Kruskal-Wallis, ANOVA and Tukey's post-hoc tests (?=0.05). There was no significant difference (p>0.05) among the materials with respect to collagen fiber formation or GRT thickness. However, Calen/ZO produced the least severe inflammatory infiltrate (p<0.05). The area of the GRT was significantly smaller (p<0.05) for Calen/ZO and Sealapex. In conclusion, Calen/ZO presented the best tissue reaction, followed by Sealapex and ZOE.
  • Influence of apical enlargement in cleaning and extrusion in canals with mild and moderate curvatures

    Borges, Mauricia Ferreira de Almeida e; Miranda, Carlos Eduardo Saraiva; Silva, Silvio Rocha Corrêa da; Marchesan, Melissa

    Resumo em Português:

    Este estudo avaliou, in vitro, por meio de microscopia óptica e morfometria, a limpeza da região apical em canais radiculares com curvatura leve e moderada submetidos ao preparo biomecânico com sistema rotatório, bem como avaliou a quantidade de material extruído para a área apical. Incisivos laterais (n = 32), sendo 16 com ângulo de curvatura igual ou inferior a 10º (GI) e 16 entre 11º e 25º (GII), foram submetidos à instrumentação rotatória com o sistema Hero 642 com diferentes diâmetros cirúrgicos: (A) 30,02 e (B) 45,02. A irrigação, a cada troca de instrumento, foi realizada com água ultra-pura de Milli Q (5 mL), e o material extruído através do forame apical foi coletado. As raízes foram submetidas a análise histológica sob microscopia óptica (40×) e as imagens foram submetidas à análise morfométrica utilizando o software Image Tool. A quantificação do material extruído foi realizada por pesagem, após a evaporação do líquido. A análise de variância não mostrou diferença estatística significante em relação à limpeza da região apical nos diferentes grupos testados (p>0,05). Considerando a quantidade de material extruído, o teste de T6ukey mostrou que os canais com curvatura leve preparados com o diâmetro cirúrgico 45,02 apresentaram os maiores valores, sendo estatisticamente diferente dos demais grupos (p<0,05) que foram semelhantes entre si (p>0,05). Pode-se concluir que a limpeza da região apical não diferiu entre os diferentes grupos, considerando a curvatura radicular e o diâmetro cirúrgico. A quantidade de material extruído foi maior nos canais preparados com curvatura leve que foram preparados com diâmetro cirúrgico 45,02.

    Resumo em Inglês:

    Optical microscopy and morphometric analysis were used in this study to evaluate, in vitro, the cleaning of the apical region in root canals with mild or moderate curvatures subjected to biomechanical preparation with a rotary system, as well as to assess the amount of extruded material to the periapical area. Lateral incisors (n = 32), 16 with curvature angles smaller or equal to 10º (GI) and 16 between 11º and 25º angles (GII) were submitted to Hero 642 rotary instrumentation with different surgical diameters: (A) 30.02 and (B) 45.02. Irrigation was performed at each change of instrument with 5 mL of ultrapure Milli-Q water and the extruded material through the apical foramen was collected. Root cross-sections were subjected to histological analysis by optical microscopy (×40) and the images were evaluated morphometrically using the Image Tool software. Quantification of the extruded material was performed by weighing after liquid evaporation. ANOVA showed no statistically significant differences (p>0.05) among the groups with respect to the procedures used to clean the apical region. Considering the amount of extruded material, the Tukey's HSD showed that canals with mild curvature prepared with the 45.02 surgical diameter showed significantly higher values (p<0.05) that those of the other groups, which were similar between themselves (p>0.05). In conclusion, the effect of cleaning the apical region did not differ in the groups, considering root curvature and the surgical diameter of instruments used for apical preparation. The amount of extruded material was greater in canals with mild curvature that were prepared with the 45.02 surgical instrument diameter.
  • Flexibility of K3 and ProTaper universal instruments

    Grazziotin-Soares, Renata; Barato Filho, Flares; Vanni, José Roberto; Almeida, Susimara; Oliveira, Elias Pandonor Motcy de; Barletta, Fernando Branco; Limongi, Orlando

    Resumo em Português:

    Esta pesquisa estudou a flexibilidade de instrumentos do Sistema K3 (conicidade 0.04) e do Sistema ProTaper Universal, por meio de um teste mecânico, quando os instrumentos eram novos e após 5 usos em canais simulados. Cinco jogos de instrumentos de cada sistema foram testados, como segue: grupo I - K3 (15, 20, 25, 30, 35, 40 e 45), e grupo II - ProTaper Universal (S1, S2, F1, F2, F3, F4 e F5). Cada jogo de instrumento foi usado para preparar um canal simulado, e o mesmo jogo de instrumento foi usado 5 vezes (50 canais). O número de cada subgrupo representou o número de usos: 0 (controle), 1, 3 e 5 usos. Antes do uso e depois de cada uso os instrumentos foram submetidos a um teste mecânico de flexibilidade realizado na máquina de ensaios universais Versat 502. A interação entre o instrumento e o número de usos foi analisada pelo ANOVA e pelo teste de Tukey ao nível de significância 5%. Instrumentos de ambos os sistemas apresentaram menor flexibilidade após o terceiro uso quando comparada com a flexibilidade após os usos 0 e 1 (p<0,05), e mantiveram a mesma flexibilidade após o quinto uso. A flexibilidade dos instrumentos do sistema K3 diminuiu conforme o aumento de diâmetro, independente do número de usos. Entre os instrumentos do sistema ProTaper Universal, os shaping apresentaram maior flexibilidade que os finishing. F2 e F3 foram os menos flexíveis e F4 e F5 apresentaram valores de flexibilidade similares ao F1.

    Resumo em Inglês:

    This study used a mechanical test to evaluate the flexibility of instruments from the K3 (conicity 0.04) and the ProTaper Universal systems when they were new and after 5 uses in simulated canals. Five sets of instruments of each system were tested: K3 (15, 20, 25, 30, 35, 40 and 45) and ProTaper Universal (S1, S2, F1, F2, F3, F4 and F5). Each set of instruments was used to prepare a simulated canal and the same set of instruments was used 5 times (50 canals). The number of each subgroup represented the number of uses: 0 (control), 1, 3 and 5 uses. Before and after each use, the instruments were submitted to a mechanical flexibility test performed in a Versat 502 universal testing machine. Interactions between the instrument and the number of uses were analyzed by ANOVA and Tukey's test at a 5% level of significance. Instruments from both systems presented lower flexibility after the third use compared to the flexibility obtained after uses 0 and 1 (p<0.05), and maintained the same flexibility after the fifth use. The flexibility of instruments from the K3 system decreased with the increase of diameter, irrespective of the number of uses. Among the instruments from the ProTaper Universal system, the shaping files presented greater flexibility than the finishing files. F2 and F3 were the least flexible instruments, and F4 and F5 presented flexibility values similar to those of F1.
  • Syndecan-1 (CD138) and Ki-67 expression in odontogenic cystic lesions

    Nadalin, Michele Regina; Fregnani, Eduardo Rodrigues; Silva-Sousa, Yara Teresinha Correa; Perez, Danyel Elias da Cruz

    Resumo em Português:

    O objetivo deste estudo foi avaliar a expressão imunoistoquímica de syndecan-1 (CD138) e Ki-67 em cistos radiculares (CR), cistos dentígeros (CD) e tumores odontogênicos queratocísticos (TOQ). Trinta e cinco CR, 22 CD e 17 TOQ foram utilizados no estudo e as reações imunoistoquímicas usando os anticorpos anti-syndecan-1 e anti-Ki-67 foram realizadas pelo método estreptavidina-biotina-peroxidase. Para análise estatística, o teste exato de Fisher e o coeficiente de correlação de Spearman foram utilizados. Entre as lesões estudadas, não foram observadas diferenças na expressão de syndecan-1, mas a expressão suprabasal de Ki-67 foi significativamente maior nos TOQ (p<0,0001), quando comparado aos CR e CD. No CR, havia correlação positiva entre a expressão (p=0,02) e intensidade (p=0,0001) de syndecan-1 e entre a intensidade de syndecan-1 e expressão de Ki-67 (p=0,01). No TOQ, a expressão de Ki-67 na camada suprabasal correlacionou positivamente com a expressão (p=0,01) e intensidade de expressão (p=0,01) de syndecan-1. A expressão de syndecan-1 não parece ser um fator determinante das características histopatológicas distintas e do comportamento biológico das lesões estudadas. Entretanto, correlação positiva entre syndecan-1 e um marcador de proliferação celular foi evidenciado em CR e TOQ.

    Resumo em Inglês:

    The aim of this study was to assess the immunohistochemical expression of syndecan-1 (CD138) and Ki-67 in radicular cysts (RC), dentigerous cysts (DC) and keratocystic odontogenic tumors (KOT). Thirty-five RC, 22 DC and 17 KOT were used in the study and immunohistochemical reactions using anti-syndecan-1 and anti-Ki-67 antibodies were performed by the streptavidin-biotin-peroxidase method. Fisher's exact test and Spearman's correlation coefficient were used for statistical analysis of data. Among the studied lesions, no differences in the syndecan-1 expression were observed, but the suprabasal expression of Ki-67 was significantly higher in KOT (p<0.0001), when compared with RC and DC. In RC, there was positive correlation between the expression (p=0.02) and intensity (p=0.0001) of syndecan-1 and between the intensity of syndecan-1 and Ki-67 expression (p=0.01). In the KOT, Ki-67 expression in the suprabasal layer correlated positively with the expression (p=0.01) and intensity (p=0.01) of syndecan-1. The expression of syndecan-1 does not seem to be a determinant factor of the distinct histopathological features and biological behavior of the studied lesions. Nevertheless, positive correlation between syndecan-1 and a cell proliferation marker was observed in RC and KOT.
  • Effect of post type and restorative techniques on the strain and fracture resistance of flared incisor roots

    Silva, Gisele Rodrigues da; Santos-Filho, Paulo César de Freitas; Simamoto-Júnior, Paulo Cézar; Martins, Luis Roberto Marcondes; Mota, Adérito Soares da; Soares, Carlos José

    Resumo em Português:

    Restaurar dentes tratados endodonticamente continua sendo desafio para clínicos. Este estudo avaliou o efeito de pinos e técnicas na deformação, resistência à fratura e padrão de fratura de incisivos com canal radicular alargado. Cento e cinco raízes bovinas, tratadas endodonticamente (15 mm) foram divididas em 7 grupos (n=15). Os grupos controle (C), constituídos de raízes não alargadas, foram restauradas com Cpc (núcleo metálico fundido) ou Gfp (pino de fibra de vidro). Nos grupos experimentais os canais foram alargados (F) e restaurados com: GfpAp (Gfp associado com pinos de fibra de vidro acessórios); GfpRc (pino anatômico, reembasado com resina composta) e GfpRcAp (pino anatomizado com resina composta e pinos acessórios). Os dentes foram restaurados com coroas metálicas. Fadiga mecânica foi simulada com 3x10(5)/50 N ciclos. O teste foi realizado a 45º e a deformação (μS) obtida nas superfícies vestibular e proximal. Em seguida, a resistência à fratura (N) e o padrão de fratura foram verificados. Aplicou-se ANOVA e Teste de Tukey (α=0,05). Não houve diferença na deformação. Cpc resultou em menor resistência à fratura e com mais fraturas catastróficas em raízes fragilizadas. As técnicas de reembasamento do pino com resina composta ou o uso de pinos acessórios parecem ser efetivos para melhorar o comportamento biomecânico de raízes fragilizadas.

    Resumo em Inglês:

    Restoring flared endodontically treated teeth continues to be a challenge for clinicians. This study evaluated the effect of post types and restorative techniques on the strain, fracture resistance, and fracture mode of incisors with weakened roots. One hundred five endodontically treated bovine incisors roots (15 mm) were divided into 7 groups (n=15). The two control groups were (C) intact roots restored with Cpc (cast posts and core) or Gfp (glass fiber posts). The five experimental groups were (F) flared roots restored with GfpAp (Gfp associated with accessory glass fiber posts), GfpRc (anatomic Gfp, relined with composite resin), and GfpRcAp (anatomized Gfp with resin and accessory glass fiber posts). All teeth were restored with metal crowns. Mechanical fatigue was performed with 3x10(5)/50 N. Specimens were loaded at 45º, and the strain values (μS) were obtained on root buccal and proximal surfaces. Following that, the fracture resistance (N) was measured. One-way ANOVA and Tukey's HSD tests (α=0.05) were applied, and failure mode was checked. No significant difference in strain values among the groups was found. Cpc presented lower fracture resistance and more catastrophic failures in flared roots. Gfp associated with composite resin or accessory glass fiber posts seems to be an effective method to improve the biomechanical behavior of flared roots.
  • Effect of monomer content in the monomer-polymer ratio on complete denture teeth displacement

    Lopes, Michelle Cristina; Consani, Rafael Leonardo Xediek; Mesquita, Marcelo Ferraz; Sinhoreti, Mário Alexandre Coelho; Consani, Simonides

    Resumo em Português:

    O propósito neste estudo foi verificar a movimentação linear de dentes em prótese total superior confeccionada com resina acrílica, proporcionada com conteúdo de monômero indicado pelo fabricante, com 25% de excesso ou com 25% a menos de monômero, nas técnicas de polimerização convencional e por microondas. Foram confeccionados 30 modelos, representando uma arcada maxilar desdentada com rebordo normal. As bases de prova e os planos de orientação foram confeccionados em cera e o conjunto montado em articulador semi-ajustável relacionado com um modelo inferior dentado. Depois da montagem dos dentes artificiais, a prótese foi moldada com silicone para duplicação das demais próteses. Foram confeccionados pontos referenciais para mensurações das distâncias entre os dentes, as quais foram analisadas com microscópio comparador linear antes e depois da desinclusão das próteses. As resinas acrílicas foram prensadas de modo convencional, alterando somente o conteúdo de monômero na proporção monômero-polímero recomendada pelo fabricante. Os dados da distância entre os dentes foram submetidos à análise de variância e ao teste de Tukey (5%). Não houve diferença estatística entre os grupos com quantidade de monômero recomendada pelo fabricante e os grupos com 25% a mais ou 25% a menos de monômero, tanto na polimerização convencional como por microondas. A alteração do conteúdo de monômero e o tipo de polimerização (convencional ou por microondas) não exerceram influência na movimentação dental nas distâncias transversal e ântero-posterior.

    Resumo em Inglês:

    The purpose of the study was to verify the linear displacement of teeth in maxillary complete dentures influenced by different monomer-polymer ratios - according to the manufacturer's instructions, with 25% excess or 25% less monomer content - in the conventional and microwaved polymerization techniques. Wax base plates and wax planes were made on edentulous maxillary stone casts according to traditional method. The set was assembled in semi-adjustable articulator with a lower toothed stone cast as guide to mounting of the maxillary artificial teeth. Impressions were taken from this tooth arrangement with silicone and the mold was used to standardize the mounting of the teeth of all dentures. Referential points were made on the artificial teeth for linear measurements with optical microscope before processing of the dentures and after deflasking. Denture bases were conventionally packed with acrylic resin according to the monomer-polymer ratio protocol. Tooth displacement data were submitted to ANOVA and Tukey test (α=0.05). There were no statistically significant differences (p>0.05) between the group with monomer content recommended by the manufacturer and groups with 25% more and 25% less monomer, in both conventional and microwaved polymerizations. Excess or less monomer in the monomer-polymer ratio and polymerization types did not change the linear distance between teeth.
  • Effect of etching time and light source on the bond strength of metallic brackets to ceramic

    Gonçalves, Paulo Roberto Amaral; Moraes, Rafael Ratto de; Costa, Ana Rosa; Correr, Américo Bortolazzo; Nouer, Paulo Roberto Aranha; Sinhoreti, Mário Alexandre Coelho; Correr-Sobrinho, Lourenço

    Resumo em Português:

    Este estudo avaliou a resistência de união de bráquetes à cerâmica testando diferentes tempos de condicionamento e fontes de luz para fotoativação do agente de união. Cilindros de cerâmica feldspática foram condicionados com ácido fluorídrico 10% por 20 ou 60 s. Após aplicação de silano na superfície da cerâmica, bráquetes metálicos foram colados aos cilindros utilizando Transbond XT (3M Unitek). Os espécimes de cada tempo de condicionamento foram divididos em 4 grupos (n=15): fonte halógena XL2500, LED UltraLume 5, laser de argônio AccuCure 3000 e arco de plasma Apollo 95E. A fotoativação foi realizada com tempo total de 40, 40, 20 e 12 s, respectivamente. O teste de cisalhamento foi realizado após 24 h. O índice de adesivo remanescente (IAR) foi avaliado sob aumento. Os dados foram submetidos a ANOVA de duas vias e teste de Tukey (p<0,05). Espécimes condicionados por 20 s apresentaram resistência de união significativamente menor que espécimes condicionados por 60 s. Não foram detectadas diferenças significativas entre as fontes de luz. O IAR mostrou predominância de escores 0 para todos os grupos, com aumento nos escores 1, 2 e 3 para o tempo 60 s. Em conclusão, apenas o tempo de condicionamento teve influência significativa na resistência de união de bráquetes à cerâmica.

    Resumo em Inglês:

    This study evaluated the bond strength of brackets to ceramic testing different etching times and light sources for photo-activation of the bonding agent. Cylinders of feldspathic ceramic were etched with 10% hydrofluoric acid for 20 or 60 s. After application of silane on the ceramic surface, metallic brackets were bonded to the cylinders using Transbond XT (3M Unitek). The specimens for each etching time were assigned to 4 groups (n=15), according to the light source: XL2500 halogen light, UltraLume 5 LED, AccuCure 3000 argon laser, and Apollo 95E plasma arc. Light-activation was carried out with total exposure times of 40, 40, 20 and 12 s, respectively. Shear strength testing was carried out after 24 h. The adhesive remnant index (ARI) was evaluated under magnification. Data were subjected to two-way ANOVA and Tukey's test (α=0.05). Specimens etched for 20 s presented significantly lower bond strength (p<0.05) compared with those etched for 60 s. No significant differences (p>0.05) were detected among the light sources. The ARI showed a predominance of scores 0 in all groups, with an increase in scores 1, 2 and 3 for the 60 s time. In conclusion, only the etching time had significant influence on the bond strength of brackets to ceramic.
  • Evaluation of different LED light-curing devices for bonding metallic orthodontic brackets

    Pinto, Corina Maia de Souza; Ferreira, José Tarcísio Lima; Matsumoto, Mírian Aiko Nakane; Borsatto, Maria Cristina; Silva, Raquel Assed Bezerra da; Romano, Fábio Lourenço

    Resumo em Português:

    O objetivo deste estudo foi avaliar a influência de diferentes aparelhos de luz tipo LED na colagem de bráquetes ortodônticos, através do teste de resistência ao cisalhamento e do Índice de Remanescente do Adesivo (IRA). Coroas de 60 incisivos bovinos receberam a colagem de bráquetes com compósito Transbond XT. A amostra foi dividida em 4 grupos (n=15) de acordo com os seguintes tipos de fotoativação: HL: controle, luz halógena; OR= Ortholux LED; UL= Ultraled XP e RD= Radii LED. Todas as fotoativações foram realizadas por 40 s. O teste de resistência ao cisalhamento foi realizado em máquina universal de ensaios mecânicos à velocidade de 0,5 mm/min. Os dados foram analisados estatisticamente pelo ANOVA e teste de Tukey. Os escores do IRA foram avaliados em lupa estereoscópica e analisados estatisticamente pelo teste de Kruskal-Wallis. O nível de significância de 5% foi adotado para todas as análises. Os valores médios (MPa) e o desvio-padrão do teste de resistência ao cisalhamento foram 9,82 (3,28), 12,70 (3,35), 9,04 (2,80) e 11,22 (2,36) para o grupo HL, OR, UL e RD, respectivamente. O grupo OR apresentou os maiores valores médios de resistência ao cisalhamento. O grupo HL diferiu significativamente (p<0,05) dos grupos OR e RD. Entretanto, este dois grupos não diferiram estatisticamente entre si (p>0,05). Quanto ao escores do IRA, nenhuma diferença estatística significante foi observada (p>0,05) entre os grupos. Concluiu-se que as unidades de luz Ortholux LED e Radii LED proporcionaram maiores valores de resistência adesiva aos bráquetes.

    Resumo em Inglês:

    The aim of this study was to assess the influence of different light-emitting diodes (LED) light-curing devices for bonding orthodontic brackets, using the shear bond strength and analysis of adhesive remnant index (ARI). Crowns from 60 bovine incisors received brackets bonded with Transbond XT. Specimens were divided into 4 groups (n=15) according to the light-curing procedures: HL = control, halogen light; OR = Ortholux LED; UL = Ultraled XP, and RD = Radii LED. All light-curing procedures were performed for 40 s. Shear bond strength test was evaluated using an universal testing machine at a crosshead speed of 0.5 mm/min. Data were analyzed statistically by ANOVA and Tukey's test. The ARI scores were evaluated with a stereoscopic magnifying glass and analyzed statistically by Kruskal-Wallis test. A significance level of 5% was set for all analyses. Shear bond strength means in MPa and standard deviations were 9.82 (3.28), 12.70 (3.35), 9.04 (2.80) and 11.22 (2.36) for HL, OR, UL and RD, respectively. OR presented the highest shear bond strength mean value. HL differed significantly (p<0.05) from Groups OR and RD. However, these groups did not differ significantly from each other (p>0.05). Regarding the ARI scores, no statistically significant difference was observed (p>0.05) among the groups. In conclusion, Ortholux LED and Radii LED units provided the highest values of bracket adhesive strength.
  • Fine-needle aspiration biopsy of ameloblastic carcinoma of the mandible: a case report

    Nai, Gisele Alborghetti; Grosso, Roque Nanci

    Resumo em Português:

    A punção aspirativa por agulha fina (PAAF) para o diagnóstico dos tumores odontogênicos tem atraído pouca atenção. A presença de um diagnóstico pré-operatório ajuda a prevenir tratamentos sub-ótimos e evita recidivas no caso destes tumores. Um caso de PAAF de carcinoma ameloblástico é apresentado, ressaltando a eficácia deste método para o diagnóstico pré-operatório dos tumores odontogênicos. Paciente feminina, de 74 anos, com abaulamento indolor na região mandibular à direita. O RX panorâmico mostrou lesão radiolúscida no corpo da mandíbula. Realizada PAAF da área, cujos esfregaços citológicos mostraram arranjo em paliçada de células basalóides e presença de células de aspecto estrelar. Tais características citológicas levam ao diagnóstico de ameloblastoma, porém na presença de atipias celulares e de mitoses atípicas, como no presente caso, o diagnóstico deve ser de carcinoma ameloblástico. Após o diagnóstico a paciente foi submetida à quimioterapia. A PAAF é um método minimamente invasivo, seguro, rápido e barato para o diagnóstico de ameloblastomas benignos e malignos, que permite que os pacientes tenham um tratamento apropriado sem a necessidade de biópsia incisional, especialmente em casos neoplásicos.

    Resumo em Inglês:

    The use of fine-needle aspiration biopsy (FNAB) in the diagnosis of odontogenic tumors seems to have attracted little attention. The presence of a firm preoperative diagnosis helps preventing suboptimal surgery, contributing to avoid recurrence of these tumors. A case of ameloblastic carcinoma of the mandible diagnosed by FNAB is presented in this report, illustrating its effectiveness for preoperative diagnosis of odontogenic tumors. A 74-year-old female presented with a painless swelling in the right mandibular angle. A panoramic radiograph revealed a radiolucent lesion in the body of the mandible. Cytological smears from FNAB in the area revealed basaloid cells with a palisade arrangement and presence of stellate-shaped cells. These cytological features lead to the diagnosis of ameloblastoma. However, when there are atypical cells and atypical mitoses, as in the present case, diagnosis of ameloblastic carcinoma may be established. The patient underwent chemotherapy, showing remission of the lesion after treatment. FNAB is a minimally invasive, safe, fast and inexpensive method for diagnosing benign and malignant ameloblastomas, which ensures that patients have a proper treatment without the need of performing an incisional biopsy, especially in neoplastic cases.
  • Clinical management of a complicated crown-root fracture: a case report

    Fidel, Sandra Rivera; Fidel-Junior, Rivail Antonio Sergio; Sassone, Luciana Moura; Murad, Cristiana Francescutti; Fidel, Rivail Antonio Sergio

    Resumo em Português:

    Este relato de caso apresenta os procedimentos clínicos envolvidos no tratamento de um caso de fratura corono-radicular complicada de um incisivo superior esquerdo com ápice aberto de um paciente de 10 anos de idade devido à queda da própria altura. O tratamento envolveu pulpotomia cervical e fixação do fragmento. Após 1 ano, os exames clínicos e radiográficos demonstraram necrose pulpar e lesão perirradicular associada. O tratamento endodôntico foi realizado com a utilização de pasta de hidróxido de cálcio, obturação endodôntica e extrusão ortodôntica. Após aproximadamente 16 semanas, o processo de extrusão foi finalizado e o dente restaurado com pino e coroa protética. Após acompanhamento de 3 anos, não havia evidência de lesão perirradicular e o dente estava estética e funcionalmente satisfatório.

    Resumo em Inglês:

    This report describes the clinical procedures involved in the treatment of a complicated crown-root fracture in the maxillary left central incisor with a wide open apex of a 10-year-old male patient, due to fall from his own height. Post-trauma treatment comprised cervical pulpotomy and adhesive tooth fragment reattachment. After 1 year, clinical and radiograph examinations showed pulp necrosis and an associated periapical lesion. Endodontic therapy with calcium hydroxide-base intracanal dressing, root canal filling and orthodontic extrusion were performed. Extrusion was completed within approximately 16 weeks and the tooth was restored with a post-core system and a prosthetic crown. After a 3 years of follow-up, there was no evidence of apical periodontitis and the tooth was satisfactory both esthetically and functionally.
Fundação Odontológica de Ribeirão Preto Av. do Café, S/N, 14040-904 Ribeirão Preto SP Brasil, Tel.: (55 16) 3602-3982, Fax: (55 16) 3633-0999 - Ribeirão Preto - SP - Brazil
E-mail: bdj@forp.usp.br