Open-access Determination of phenobarbital in human plasma by a specific liquid chromatography method: application to a bioequivalence study

Abstract

A liquid chromatography method was developed and validated for the determination of phenobarbital in human plasma using phenytoin as internal standard. The drugs were extracted from plasma by liquid-liquid extraction and separated isocratically on a C12 analytical column, maintained at 35 ºC, with water:acetonitrile:methanol (58.8:15.2:26, v/v/v) as mobile phase, run at a flow rate of 1.2 mL/min with detection at 205 nm. The method was linear in the range of 0.1-4 μg/mL (r²=0.9999) and demonstrated acceptable results for the precision, accuracy and stability studies. The method was successfully applied for the bioequivalence study of two tablet formulations (test and reference) of phenobarbital 100 mg after single oral dose administration to healthy human volunteers.

human plasma; liquid chromatography; phenobarbital


ARTIGO

Determination of phenobarbital in human plasma by a specific liquid chromatography method: application to a bioequivalence study

Sérgio Luiz DalmoraI, *; Maximiliano da Silva SangoiI; Daniele Rubert NogueiraI; Felipe Bianchini D'AvilaI; Ronílson Agnaldo MorenoII; Carlos Eduardo SverdloffIII; Rogério Antonio de OliveiraIV; Ney Carter BorgesV

IDepartamento de Farmácia Industrial, Universidade Federal de Santa Maria, 97105-900 Santa Maria - RS, Brasil

IISynchrophar Assessoria e Desenvolvimento de Projetos Clínicos S/S Ltda., 13070-200 Campinas - SP, Brasil / Faculdade de Ciências Médicas, Universidade Estadual de Campinas, 13083-970 Campinas - SP, Brasil

IIISynchrophar Assessoria e Desenvolvimento de Projetos Clínicos S/S Ltda., 13070-200 Campinas - SP, Brasil

IVSynchrophar Assessoria e Desenvolvimento de Projetos Clínicos S/S Ltda., 13070-200 Campinas - SP, Brasil / Instituto de Matemática e Estatística, Universidade de São Paulo, 05508-900 São Paulo - SP, Brasil

VSynchrophar Assessoria e Desenvolvimento de Projetos Clínicos S/S Ltda., 13070-200 Campinas - SP, Brasil / Faculdade de Ciências Médicas, Universidade Estadual de Campinas, 13083-970 Campinas - SP, Brasil

ABSTRACT

A liquid chromatography method was developed and validated for the determination of phenobarbital in human plasma using phenytoin as internal standard. The drugs were extracted from plasma by liquid-liquid extraction and separated isocratically on a C12 analytical column, maintained at 35 ºC, with water:acetonitrile:methanol (58.8:15.2:26, v/v/v) as mobile phase, run at a flow rate of 1.2 mL/min with detection at 205 nm. The method was linear in the range of 0.1-4 μg/mL (r2=0.9999) and demonstrated acceptable results for the precision, accuracy and stability studies. The method was successfully applied for the bioequivalence study of two tablet formulations (test and reference) of phenobarbital 100 mg after single oral dose administration to healthy human volunteers.

Keywords: human plasma; liquid chromatography; phenobarbital.

INTRODUCTION

Epilepsy is among the most common serious neurological disorders worldwide. This disorder can be successfully controlled with a single well-tolerated antiepileptic drug in the majority of cases,1 but when monotherapy fails, antiepileptic drugs should be combined.2 The seizures of this disease may result in injury and embarrassment, anxiety, unpredictability, and can occasionally kill. With the correct diagnosis and treatment, many patients will have a significant reduction in seizure frequency or be seizure free.3

Phenobarbital (Figure 1) is a substituted barbituric acid that acts as a nonselective central nervous system depressant, and is widely used as antiepileptic drug due to advantages including reliability of supply, affordable cost, broad spectrum of action, and ease of use.3,4 It is also used for partial and generalized tonic-clonic seizures treatment.5


The liquid chromatography (LC) methods coupled to mass spectrometry (MS) by atmospheric pressure chemical ionization were carried out by solid phase extraction (SPE) for the determination of phenobarbital in human plasma.6,7 The gas chromatography coupled to MS using selected-ion monitoring mode and deuterated internal standard was also applied to biological matrix.8 Besides, capillary electrophoresis performed by combining multiwavelength detection with micellar electrokinetic capillary chromatography technique9 and micellar liquid chromatography with direct injection of the plasma samples after addition of a SDS solution were also applied to human plasma.10 Simultaneous determination of phenobarbital and some drugs in human plasma was performed by different methods to support pharmacokinetic and clinical studies.6-9,11-22 A chiral LC method was developed and validated for the determination of phenobarbital and methylphenobarbital enantiomers in human plasma using a C18 precolumn and a chiral column for the enantiomeric separation.23 The RP-LC methods were developed with UV detection and using stir bar-sorptive extraction,11 liquid-liquid extraction (LLE),12,13,21 direct injection of plasma with manual column-switching technique,17 SPE,22 or protein precipitation.18-20 However, some of these methods show disadvantages such as low sensitivity, complicated and extensive sample preparation, and most of them did not demonstrate any applicability for pharmacokinetic or bioequivalence studies. Besides, an RP-LC method using SPE was applied for the oral bioavailability evaluation of two liquid dosage forms in comparison to a phenobarbital tablet, but the validation parameters were not properly described, and the procedure to prepare the samples is time-consuming which could not meet the requirement of high-throughput analysis recommended for the bioequivalence studies.24

Considering the large number of samples generated and the requirements for the bioequivalence studies, the aim of the present article was to develop and validate a simple, specific and sensitive LC method, using a single step liquid-liquid extraction procedure. This method was applied to a pharmacokinetic analysis of phenobarbital in human plasma supporting a bioequivalence study of two pharmaceutical formulations.

EXPERIMENTAL

Chemicals and reagents

The test and reference formulations containing 100 mg of phenobarbital were manufactured by the Cristália Produtos Químicos Farmacêuticos Ltda. (Itapira, SP, Brazil), Batch 07085825 and Sanofi-Aventis (Suzano, SP, Brazil), Batch 701509, respectively, within their shelf life period. Phenobarbital reference substance (Lot J) and phenytoin (Lot J0E090) as internal standard (IS) were purchased from U.S. Pharmacopeia (USA). HPLC grade acetonitrile, methanol and tert-butyl methyl ether were obtained from Tedia (Fairfield, Ohio, USA). For all the analyses, ultrapure water was purified using an Elix 3 coupled to a Milli-Q Gradient A10 system (Millipore, Bedford, MA, USA). All solutions were filtered through a 0.22 μm membrane filter (Millipore, Bedford, MA, USA).

Apparatus and chromatographic conditions

The RP-LC method was carried out on a Shimadzu LC system (Shimadzu, Kyoto, Japan) equipped with a SCL-10AVP system controller, a LC-10 ADVP pump, a DGU-14A degasser, a SIL-10ADVP autosampler, and a SPD-M10AVP PDA detector. The peak areas were integrated automatically by computer using a Shimadzu Class VP V 6.14 software program. The experiments were carried out on a reversed phase Phenomenex (Torrance, USA) Synergi MAX-RP C12 analytical column (150 x 4.6mm I.D., with a particle size of 4 μm and pore size of 80 Å) maintained at 35 ºC. The LC system was operated isocratically using a mobile phase of water:acetonitrile:methanol (58.8:15.2:26, v/v/v). This was filtered through a 0.45 μm membrane filter (Millipore) and run at a flow rate of 1.2 mL/min, detected at 205 nm by a PDA detector. The injection volume was 25 μL for both standard and samples. The temperature of the autosampler was kept at 4 ºC and the run time was 12 min.

Standard solutions and calibration curves

The stock solutions of phenobarbital and IS were prepared by weighing 10 mg of reference material into a 10 mL individual volumetric flask and dissolving to volume with methanol:water (90:10, v/v), obtaining a concentration of 1 mg/mL. The prepared stock solutions were stored at 2-8 ºC protected from light. Analytical curves of phenobarbital were prepared by spiking blank plasma at concentrations from 0.1 to 4 μg/mL. The quality control (QC) samples were prepared in blank plasma at concentrations of 0.25 (low), 1.8 (medium), and 3.4 μg/mL (high), and then divided in aliquots that were stored at -80 ºC until analysis. The spiked plasma samples (standards and quality controls) were extracted on each analytical batch along with the unknown samples.

Plasma extraction

For the analysis of phenobarbital, 300 μL of each plasma sample was transferred to a 15 mL glass tube, followed by addition of 50 μL of IS solution (15 μg/mL). All samples were mixed by vortex agitation for 30 s. Then, 4 mL aliquot of extraction solvent, tert-butyl methyl ether, was added using a Dispensette Organic (Brand GmbH, Wertheim, Germany) and vortex mixed for 90 s. The tubes were centrifuged for 15 min at 2700 rpm and the organic layer was filtered through a Millex GV 0.45 mm filter unit (Millipore, Bedford, MA, USA) into 15 mL conical tubes and evaporated under a nitrogen stream while immersed in a 40 ºC water bath. The residues were reconstituted with 300 μL of mobile phase. The samples were transferred to auto-sampler vials and 25 μL was injected into the LC system.

Validation of the bioanalytical method

The method was validated by the determination of the following parameters: specificity, linearity and range, recovery, accuracy, precision, lower limit of quantitation (LLOQ), and stability studies, following the bioanalytical method validation guidelines.25,26

Specificity was assessed using six blank human plasma samples, randomly selected, from different sources (including haemolysed and lipemic plasma), that were subjected to the extraction procedure and chromatographed to determine the extent to which endogenous plasma components could interfere in the analysis of phenobarbital or the IS. The results were compared to a solution containing 0.1 μg/mL of phenobarbital.

The analytical curves were constructed from a blank sample (plasma sample processed without IS), a zero sample (plasma processed with IS), and eight concentrations of phenobarbital, including the LLOQ, ranging from 0.1 to 4 μg/mL. The peak area ratio of the drug to the IS against the respective standard concentrations was used for plotting the graph and the linearity evaluated by least square regression analysis. The acceptance criteria for each calculated standard concentration was not more than 15% deviation from the nominal value, except for the LLOQ, which was set at 20%.

The recovery was evaluated by the mean of the response of three concentrations of phenobarbital (0.25, 1.8, and 3.4 μg/mL), each one with addition of 2.5 μg/mL of the IS, dividing the mean of the extracted sample by the mean of the unextracted sample (spiked with the extracted blank plasma residues) at the same concentration level. To eliminate the matrix effects, a comparison of the extracted to the unextracted sample was performed, giving the true recovery.

To evaluate the inter-day precision and accuracy, QC samples were analyzed together with one independent analytical standard curve for 3 days, while intra-day precision and accuracy were evaluated through analysis of the QC samples in six replicates in the same day. Inter- and intra-day precision were expressed as relative standard deviation (RSD). The evaluation of precision and accuracy was based on the criteria that the RSD of each concentration level should be within 15% of the nominal concentration.26

The lowest standard concentration on the analytical curve should be accepted as the limit of quantitation if the following conditions are met: the analyte response at the LLOQ should be at least five times the response compared to blank response and analyte peak (response) should be identifiable, discrete, and reproducible with a precision of 20% and accuracy of 80-120%. The limit of detection (LOD) was defined by the concentration with a signal-to-noise ratio of 3.

The stability of phenobarbital in human plasma was evaluated after each storage period and related to the initial concentration as zero cycle (samples that were freshly prepared and processed immediately). The samples were considered stable if the deviation (expressed as percentage bias) from the zero cycle was within ±15%. The freeze-thaw stability of phenobarbital was determined at low, medium, and high QC samples (n = 3) over three freeze thaw cycles within 3 days. In each cycle, the frozen plasma samples were thawed at room temperature for 2 h and refrozen for 24 h. After completion of each cycle the samples were analyzed and the results compared with that of the zero cycle. The short term stability was evaluated using three aliquots each of the low, medium, and high unprocessed QC samples kept at room temperature (25 ± 5 ºC) for 8 h, and then analyzed. For the processed sample stability, three aliquots each one of the low, medium, and high QC samples were processed and placed into the autosampler at 5 ºC and analyzed after 24 and 48 h. For the long term stability analysis of phenobarbital, three aliquots of each QC samples were frozen at -80 ºC for 100 days and then analyzed.

Bioequivalence study

The study was an open, randomized, two period crossover design with a 42 days washout interval between the doses. Due to the long elimination half-life of phenobarbital, the study was truncated at 72 h, as recommended.27,28 Nineteen healthy volunteers of both sexes, aged between 18 and 50 years, and within 15% of the ideal body weight were selected by clinical evaluation and laboratory tests. The clinical protocol was approved by the local Ethic Committee and the volunteers given written informed agreements to participate in the study. During each period, a single oral dose of phenobarbital (1 tablet 100 mg) was given with 200 mL of water after an overnight fast of at least 8 h. Blood samples were collected at 0 h (predose) and at: 0.25, 0.5, 0.75, 1, 1.5, 2, 3, 4, 5, 6, 8, 12, 24, 48 and 72 h post dosing. The samples were centrifuged immediately (at 3000 rpm for 15 minutes at 4ºC), and the plasma separated and kept frozen at -80 ºC in labeled cryogenic tubes until assayed.

Pharmacokinetic and statistical analysis

The pharmacokinetic parameters of phenobarbital, namely: the maximum plasma concentration (Cmax) and time point of maximum plasma concentration (Tmax) were obtained directly from the measured data. The area under the phenobarbital plasma concentration time curve (AUC(0-t)) was computed using the linear trapezoidal rule. The pharmacokinetic parameters of phenobarbital were estimated with softwares Microsoft Excel 97, Scientific Work Place, WinNonlin Professional version 5.2, Equivtest version 2.0 and Graph Pad Prism version 5.

After logarithmic transformation, AUC(0-t) and Cmax values were subjected to analysis of variance (ANOVA), including the effects of sequence, period and treatment and random effect of subjects (sequence), as described by Chow and Liu.29 For the evaluation of bioequivalence, the point estimates and 90% confidence interval (CI) for the geometric means ratio of AUC(0-t) and Cmax were constructed, using the residual mean square error obtained from the ANOVA.

The bioequivalence between the two formulations was evaluated based on the 90% CI transformed back for the geometric mean ratios of AUC(0-t) and Cmax, which are recommended within the 80-125% interval according to the guidelines.27,28

RESULTS AND DISCUSSION

Optimization of the method

In order to obtain a simple and effective analytical method, many pretreatment procedures were assayed. Protein precipitation was also tested, showing poor results of recovery and baseline instabilities. Different methods showed that phenobarbital and others antiepileptic drugs could be isolated from plasma by liquid-liquid extraction. Therefore various liquid-liquid extraction procedures were assayed. The presented extraction was chosen because it reliably eliminated interfering material from plasma, with higher recovery of phenobarbital.

To obtain the best chromatographic separation, the mobile phase was optimized to provide sufficient specificity and sensitivity in a short separation time. Various combinations of organic solvents (methanol and acetonitrile) and water were evaluated as mobile phase components. The mobile phase selected resulted in higher specificity, better sensitivity, short analysis time, improving the peak symmetry. Analytical columns with different packing materials including the C18 and C8 were evaluated, and resulted in poor separation of the analytes and the plasma endogenous substances. Then, the Synergi MAX-RP C12 analytical column was selected as it provides the best chromatographic performance and acceptable peak characteristics, including tailing factor, number of theoretical plates and capacity factor. Moreover, good resolution of phenobarbital, IS and the plasma interfering peaks was obtained, thus confirming the specificity of the proposed method. For the selection of the best wavelength detection a PDA detector was used. The optimized conditions of the LC method were validated for the analysis of phenobarbital in human plasma, due to the capability and application for the bioequivalence study.

Representative chromatograms of a blank plasma, plasma spiked with phenobarbital at 0.25 μg/mL and plasma obtained from the human volunteer 3 h after administration of 100 mg phenobarbital are presented in Figure 2, with peaks symmetry values between 1.25 and 1.44, assuring the separation and the effectiveness of the quantitation. The resulting retention times were 4.68 (phenobarbital) and 9.75 min (IS). There were no interfering peaks in drug-free plasma eluting at the retention times of interest. Chromatograms obtained from six different human plasma samples showed that the method is adequately specific.


The proposed method is based on a simple, rapid and efficient sample pre-treatment which allows the determination of phenobarbital in biological matrix with a reasonable elution time and suitable sensitivity, thus fulfilling the criteria required for pharmacokinetic and bioequivalence studies.

Validation of the method

Linearity was evaluated by six determinations of eight concentrations in the range of 0.1-4 μg/mL. The values of the determination coefficient (r2 = 0.9999, y = 0.000327x - 0.005366) indicated significant linearity of the analytical curves for the method. The LLOQ was evaluated in an experimental assay and was found to be 0.1 μg/mL with precision and accuracy lower than 20%. Comparison of the blank and spiked human plasma (0.1 μg/mL) chromatograms indicated that no significant interferences were detected from endogenous substances.

Phenobarbital in human plasma was directly extracted with tert-butyl methyl ether by liquid-liquid extraction. The mean extraction recoveries for the three concentration levels of the QC samples were 94.47% for phenobarbital and 96.18% for the IS showing the method suitability (Table 1).

The intra-day accuracy of the method was within 99.49 and 104.56% with a precision of 1.13-4.14%. The inter-day accuracy was within 98.51 and 103.98% with RSD of 2.35-3.05% (Table 2). The data show that the method possesses adequate repeatability and reproducibility.

Phenobarbital was stable in neat plasma for up to 8 h at room temperature (short-term) and also after three freeze thaw cycles, demonstrating that human plasma samples could be thawed and refrozen without compromising the integrity of the samples. Plasma samples were stable for at least 100 days at -80 ºC (long-term). The results demonstrated that extracted samples could be analyzed after being kept in the autosampler for at least 48 h with acceptable precision and accuracy. The results of stability of phenobarbital in human plasma are shown in Table 3.

Pharmacokinetic and statistical analysis

The mean pharmacokinetic parameters after a single 100 mg oral dose administration of test and reference products to nineteen healthy volunteers are presented in Table 4.

No period effect was observed in the pharmacokinetic parameters studied (data not shown). The curve of the mean phenobarbital plasma concentration versus time obtained after a single oral dose of each phenobarbital formulation is shown in Figure 3. The individual overlays of plasma concentration - time profiles of phenobarbital after oral administration of Test (a) and Reference (b) in healthy volunteers are shown in Figure 4.



At any of the evaluation times, the mean values and the concentrations of phenobarbital seemed non significant differences between the individual subjects studied after the administration of each of the 2 formulations. The mean Cmax , obtained at 1.49 and 1.92 h, were 3.22 and 3.11 μg/mL for test and reference formulations, respectively. These values of Cmax were higher than that reported in the literature for the same tablet dosage as 2.30 μg/mL, and were similar for the Tmax.24

Further statistical analysis of pharmacokinetic variables that described the early and total exposure to phenobarbital showed point estimates of the geometric means ratios of Cmax and AUC(0-t) (phenobarbital test vs. phenobarbital reference) to be 103.93% (90% CI: 97.04-111.32) and 99.62% (90% CI: 97.47-101.82), respectively (Table 5). The relative standard deviation (RSD) and the power were 12.19 and 99.94% for Cmax and 3.86 and 99.98% for AUC(0-t). For Tmax values of each subject, the nonparametric Wilcoxon test were applied to the differences from test and reference and no significant differences (P = 0.05) were found between the two formulations evaluated. The nonparametric 90% CI for Tmax difference of Test and Reference for women and men were (-1.5; 0.12) and (-1.12; 1), respectively. The nonparametric Wilcoxon test was applied to Tmax differences of men and women and it has present not significant difference between men and women for Tmax (p value = 0.279).

CONCLUSION

A specific LC method, with a single step liquid-liquid extraction procedure, has been developed and validated for the determination of phenobarbital in human plasma supporting a pharmacokinetic and bioequivalence study. The statistical analysis demonstrated that none of the parameters accepted for drug bioavailability (AUC(0-t) and Cmax) were not significantly different between the treatments for the single dose data. Moreover, it indicated that the two pharmaceutical products showed similar bioavailability profiles and therefore are considered bioequivalent with regard to the extent and rate of absorption and, interchangeable as well, for clinical and therapeutic purposes.

ACKNOWLEDGEMENTS

The authors wish to thank Cristália Produtos Químicos Farmacêuticos (São Paulo, Brazil) for the support.

Recebido em 17/2/09; aceito em 22/6/09; publicado na web em 25/11/09

References

  • 1. Kwan, P.; Brodie, M. J.; N. Engl. J. Med. 2000, 342, 314.
  • 2. Brodie, M. J.; French, J. A.; Lancet 2000, 356, 323.
  • 3. Wang, W. Z.; Wu, J. Z.; Ma, G. Y.; Dai, X. Y.; Yang, B.; Wang, T. P.; Yuan, C. L.; Hong, Z.; Bell, G. S.; Prilipko, L.; de Boer, H. M.; Sander, J. W.; Lancet Neurol. 2006, 5, 46.
  • 4. Kwan, P.; Brodie, M. J.; Epilepsia 2004, 45, 1141.
  • 5 WHO; Initiative of support to people with epilepsy, Geneva: World Health Organization, 1990.
  • 6. Subramanian, M.; Birnbaum, A. K.; Remmel, R. P.; Ther. Drug Monit. 2008, 30, 347.
  • 7. Kanazawa, H.; Konishi, Y.; Matsushima, Y.; Takahashi, T.; J. Chromatogr., A 1998, 797, 227.
  • 8. Peters, F. T.; Jung, J.; Kraemer, T.; Maurer, H. H.; Ther. Drug Monit. 2005, 27, 334.
  • 9. Lee, K. J.; Heo, G. S.; Kim, N. J.; Moon, D. C.; J. Chromatogr. 1992, 608, 243.
  • 10. Martín-Biosca, Y.; Sagrado, S.; Villanueva-Camãnas, R. M.; Medina-Hernández, M. J.; Biomed. Chromatogr. 2000, 14, 113.
  • 11. Queiroz, R. H. C.; Bertucci, C.; Malfará, W. R.; Dreossi, S. A. C.; Chaves, A. R.; Valério, D. A. R.; Queiroz, M. E. C.; J. Pharm. Biomed. Anal. 2008, 48, 428.
  • 12. Matar, K. M.; Nicholls, P. J.; Tekle, A.; Bawazir, S. A.; Al-Hassan, M. I.; Ther. Drug Monit. 1999, 21, 559.
  • 13. Dutov, A. A.; Temnikova, I. V.; Fedotova, A. A.; Gol'tvanitsa, G. A.; Eksp. Klin. Farmakol. 1999, 62, 53.
  • 14. Johansen, K.; Krough, M.; Andresen, A. T.; Cristophersen, A. S.; Lehne, G.; Rasmussen, K. E.; J. Chromatogr., B: Biomed. Sci. Appl. 1995, 669, 281.
  • 15. Romanyshyn, L. A.; Wichmann, J. K.; Kurcharczyk, N.; Shumaker, R. C.; Ward, D.; Sofia, R. D.; Ther. Drug Monit. 1994, 16, 90.
  • 16. Richard, L.; Leducq, B. ; Baty, C.; Jambou, J.; Ann. Biol. Clin. 1989, 47, 79.
  • 17. Berg, J. D.; Buckley, B. M.; Ann. Clin. Biochem. 1987, 24, 488.
  • 18. Kushida, K.; Ishizaki, T.; J. Chromatogr. 1985, 338, 131.
  • 19. Chun-Lai, M.; Zheng, J.; Yang, J.; Xiao-Jin, S.; Chromatographia 2007, 65, 267.
  • 20. Cavazos, M. L. S.; Cruz, V. T.; Torres, N. W.; López, A. P.; J. Liq. Chromatogr. Relat. Technol. 2005, 28, 693.
  • 21. Sanches, C.; López, K. V.; Omosako, C. E.; Bertoline, M. A.; Pereira, M. D.; Santos, S. R. C. J.; Lat. Am. J. Pharm 2008, 27, 485.
  • 22. Vermeij, T. A.; Edelbroek, P. M.; J. Chromatogr., B: Anal. Technol. Biomed. Life Sci. 2007, 857, 40.
  • 23. Ceccato, A.; Boulanger, B.; Chiap, P.; Hubert, P.; Crommen, J.; J. Chromatogr., A 1998, 819, 143.
  • 24. Yska, J. P.; Essink, G. W. G.; Bosch, F. H.; Lankhaar, G.; van Sorge, A. A.; Pharm. World Sci. 2000, 22, 67.
  • 25 ANVISA, Diário Oficial da União, Poder Executivo, 02/06/2003; Guia para Validação de Métodos Analíticos e Bioanalíticos, Brasil, 2003.
  • 26. FDA, Center for Drug Evaluation and Research, US Department of Health and Human Services, Guidance for Industry; Bioanalytical Method Validation, 2001.
  • 27 ANVISA, Diário Oficial da União, Poder Executivo, 19/04/2006; Guia para Provas de Biodisponibilidade Relativa/Bioequivalência de Medicamentos, Brasil, 2006.
  • 28 FDA, Center for Drug Evaluation and Research, US Department of Health and Human Services, Guidance for Industry; Bioavailability and Bioequivalence Studies for Orally Administered Drug Products - General Considerations, 2002.
  • 29. Chow, S. C.; Liu, J. P.; Design and Analysis of Bioavailability and Bioequivalence Studies, 2nd ed., Marcel Dekker, Inc.: New York, 2000.
  • *
    e-mail:
  • Publication Dates

    • Publication in this collection
      05 Feb 2010
    • Date of issue
      2010

    History

    • Received
      17 Feb 2009
    • Accepted
      22 June 2009
    location_on
    Sociedade Brasileira de Química Instituto de Química, Universidade Estadual de Campinas (Unicamp), CP6154, 13083-0970 - Campinas - SP - Brazil
    E-mail: quimicanova@sbq.org.br
    rss_feed Acompanhe os números deste periódico no seu leitor de RSS
    Acessibilidade / Reportar erro