Objective: to analyze the effectiveness of peripherally inserted central catheter insertion techniques in preventing the occurrence of complications related to this device in newborns.
Method: a paired and network systematic literature review and meta-analysis, with its search carried out in seven databases and in the Grey Literature, including randomized and non-randomized clinical trials. The risk of bias was assessed using the Cochrane Risk of Bias 2 and Risk of Bias In Non-randomized Studies of Interventions tools. Certainty of the evidence was assessed by means of the Grading of Recommendations Assessment, Development and Evaluation. A meta-analysis was carried out with the aid of the R statistical program.
Results: eight studies with 1,126 newborns were included and six insertion techniques were identified: intracavitary electrocardiogram; intracavitary electrocardiogram associated with ultrasound; ultrasound; formula; anatomical landmark; and modified anatomical landmark. Five techniques significantly decreased primary tip malpositioning when compared to the control ( p <0.05). Intracavitary electrocardiogram significantly and more effectively reduced arrhythmias, general complications and phlebitis; the technique that used a formula also reduced general complications. Infection, infiltration, secondary tip malpositioning, catheter rupture, thrombosis, occlusion and catheter-associated skin lesion were not significantly preventable events.
Conclusion: intracavitary electrocardiogram and use of the formula were the most effective techniques in reducing complications.
Descriptors: Newborn Infant; Peripheral Catheterization; Central Venous Catheters, Treatment Failure; Neonatal Nursing; Neonatal Intensive Care Units
Objetivo: analizar la efectividad de las técnicas de inserción de catéter central de inserción periférica en la prevención de la aparición de complicaciones asociadas con este dispositivo en recién nacidos.
Método: revisión sistemática de la literatura y metaanálisis pareado y en red, la búsqueda se realizó en siete bases de datos y en la literatura gris, se incluyeron ensayos clínicos aleatorizados y no aleatorizados. El riesgo de sesgo se evaluó mediante las herramientas Cochrane Risk of Bias 2 y Risk of Bias In Non-randomized Studies of Interventions . La certeza de la evidencia a través de la Grading of Recommendations Assessment, Development and Evaluation . Se realizó un metaanálisis con ayuda del programa estadístico R.
Resultados: se incluyeron ocho estudios, con 1126 recién nacidos, y se identificaron seis técnicas de inserción: electrocardiograma intracavitario, electrocardiograma intracavitario asociado a ultrasonido, ultrasonido, fórmula, punto anatómico de referencia y punto anatómico de referencia modificado. Cinco técnicas redujeron significativamente el mal posicionamiento primario de la punta en comparación con el control (p<0,05). El electrocardiograma intracavitario redujo de manera significativa y más efectiva las arritmias, las complicaciones generales y la flebitis; la técnica que utilizó una fórmula también redujo las complicaciones generales. La infección, la infiltración, el mal posicionamiento secundario de la punta, la rotura del catéter, la trombosis, la oclusión y las lesiones de la piel asociadas con el catéter son eventos que no se revinieron significativamente.
Conclusión: el electrocardiograma intracavitario y el uso de la fórmula fueron las técnicas más efectivas para reducir las complicaciones.
Descriptores: Recíen Nacido; Cateterismo Periférico; Catéteres Venosos Centrales; Insuficiencia del Tratamiento; Enfermería Neonatal; Unidades de Cuidado Intensivo Neonatal
Objetivo: analisar a efetividade das técnicas de inserção de cateter central de inserção periférica na prevenção da ocorrência de complicações relacionadas a este dispositivo em recém-nascidos.
Método: revisão sistemática da literatura e metanálise pareada e em rede, com busca realizada em sete bases de dados e na literatura cinzenta, inclusão de ensaios clínicos aleatorizados e não aleatorizados. O risco de viés foi avaliado pelas ferramentas da Cochrane Risk of Bias 2 e o Risk of Bias In Non-randomised Studies of Interventions. A certeza da evidência pelo Grading of Recommendations Assessment, Development and Evaluation. Realizou-se metanálise com auxílio do programa estatístico R.
Resultados: oito estudos, com 1126 recém-nascidos, foram incluídos e seis técnicas de inserção identificadas: eletrocardiograma intracavitário, eletrocardiograma intracavitário associado à ultrassonografia, ultrassonografia, fórmula, marco de referência anatômico e marco de referência anatômico modificado. Cinco técnicas diminuíram significativamente o mau posicionamento primário da ponta quando comparadas com o controle ( p <0,05). O eletrocardiograma intracavitário diminuiu arritmias, complicações gerais e flebite de forma significativa e mais efetiva; a técnica que utilizou uma fórmula também reduziu complicações gerais. Infecção, infiltração, mau posicionamento secundário da ponta, ruptura do cateter, trombose, oclusão e lesão de pele associada ao cateter não foram eventos prevenidos significativamente.
Conclusão: eletrocardiograma intracavitário e uso da fórmula foram as técnicas mais efetivas na redução de complicações.
Descritores: Recém-Nascido; Cateterismo Periférico; Cateteres Venosos Centrais; Falha de Tratamento; Enfermagem Neonatal; Unidades de Terapia Intensiva Neonatal
Highlights:
(1) Some PICC insertion techniques have reduced their related complications.
(2) Primary tip malpositioning was the most prevented complication.
(3) Intracavitary electrocardiogram reduced arrhythmias, phlebitis and general complications.
(4) The technique that used the formula significantly reduced general complications.
Introduction
Peripherally Inserted Central Catheters (PICCs) are widely used in newborns (NBs) ( 1 - 2 ) . They have several advantages over the use of other central vascular access devices and short peripherally inserted catheters, such as preserving the peripheral vascular system ( 3 ) , reducing the risks of phlebitis and infections ( 3 - 4 ) , of the need for repeated punctures ( 4 - 5 ) and of the pain and stimuli to which NBs are subjected ( 3 - 5 ) .
Despite the advantages, PICC use is associated with different types of complications that can increase neonatal morbidity and mortality ( 6 - 7 ) , increase costs for the health system and compromise the patients’ quality of life ( 8 - 10 ) .
PICC-related complications can occur since their insertion, passing through the dwell period and even after their removal ( 6 ) . According to the Infusion Nursing Society (INS) (2021), the complications related to the insertion of central vascular access devices such as PICCs are as follows: arterial puncture; cardiac arrhythmias; nerve injury; air embolism; and primary malpositioning of the central vascular access device ( 11 ) . Many complications such as catheter-associated deep vein thrombosis, secondary malpositioning (intra- or extra-vascular catheter tip migration), central line-associated bloodstream infection, phlebitis, infiltration, leaks, catheter rupture, occlusion and device-associated skin lesion might be prevented depending on the insertion technique used ( 11 ) .
From the point of view of the insertion technique, some precautions such as the method used to guide the insertion interfere with PICC-related complications, that is, actions performed during insertion of this device can prevent complications related to its introduction and the late ones that occur with permanence of the PICC ( 11 ) .
Some studies and sets of good practices recommend using technologies in PICC insertion in order to prevent related complications and increase patient safety, such as ultrasound (USG) ( 11 - 12 ) , catheter-vein ratio ( 11 ) and intracavitary electrocardiogram (IC-ECG) ( 11 , 13 - 14 ) . For health institutions, there is a reduction in costs related to the treatment of complications since, in some situations, removal of this device requires another puncture and, oftentimes, it is necessary to use new catheters, in addition to the increase in the nursing time spent ( 5 , 10 - 11 ) .
USG can be used to determine the optimal size of the catheter to be introduced according to the diameter of the vein (catheter-vein ratio), to locate the tip, and for vascular visualization to guide the puncture. This can reduce complications and the need for repositioning, as well as increase the success chances at the first puncture attempt and provide greater patient satisfaction ( 11 - 12 , 15 ) .
Through electrodes on the body surface and in contact with the catheter, an IC-ECG monitors changes in the size of the electrocardiogram P wave, whose elevation indicates that the catheter tip reached the cavoatrial junction through the superior vena cava ( 14 ) . This technique strains, in real time, the correct position of the tip of the device, leading to significantly more successful central positions due to its immediate adjustment, in addition to providing immediate treatment and eliminating the need to confirm the tip position by means of a radiological examination ( 13 - 14 , 16 ) .
Review studies on the relationship among all insertion techniques and PICC-related complications in NBs were not identified in the literature or on the registration platforms of this review.
For this reason, this study aimed at analyzing the effectiveness of peripherally inserted central catheter insertion techniques in preventing the occurrence of complications related to this device in newborns. A network meta-analysis was used to achieve this objective, as it allows for a comparison among three or more concurrent interventions simultaneously in a single analysis, combining direct evidence (studies in which the interventions of interest are compared) and indirect evidence (studies in which the interventions of interest with a common comparator are compared). The effect estimates from direct and indirect comparison studies are combined into a network of interventions ( 17 ) .
Method
This is a systematic literature review with paired and network meta-analysis, reported according to the PRISMA (Preferred Reporting Items Systematic Reviews and Meta-Analysis Checklist) ( 18 ) and PRISMA-Network Meta-Analyses (PRISMA-NMA) ( 19 ) guidelines. The protocol was registered on the PROSPERO platform under number CRD42022324152.
The PICOS ( 17 ) (acronym for Population, Interventions, Comparators, Outcomes, and Study design) strategy was used to delimit the guiding question of this review: In newborn patients (P), which PICC insertion technique (I) is most effective in preventing the occurrence of complications related to the use of this device (O)?
Eligibility criteria
Randomized and non-randomized controlled trials were included, which evaluated PICC insertion techniques in hospitalized newborns and PICC-related complications referred to as outcome measures.
The studies excluded were those that evaluated complications related to PICC use in NBs receiving outpatient care; as well as those that evaluated complications related to PICC use in newborns in Mixed Intensive Care Units (they care for newborns together with children); those that evaluated complications related to PICC use in children and adults; those that did not describe the insertion techniques; those that evaluated different types of PICCs, insertion sites or dressings; those that evaluated insertion techniques for other types of central vascular access devices; observational studies; qualitative studies; conference abstracts, reviews, editorials, experts’ opinions, case reports and series, reflection articles; and studies without a comparison group.
Information sources
The search was carried out in the following electronic databases: Cumulative Index to Nursing and Allied Health Literature (CINAHL), Cochrane CENTRAL, Embase, Latin American and Caribbean Literature in Health Sciences (LILACS), PubMed, Scopus and Web of Science. The grey literature was consulted through the Google Scholar and Open Gray databases. The reference lists of the studies included were also consulted in order to identify any publications not previously identified in the searches. In addition to that, there was an active search for publications that might comprise the sample for this review through consultation with experts. The search was carried out on January 1 st , 2023.
Search strategy
The search strategy was developed based on the guiding question of this review, using the “OR” Boolean operator between synonyms and similar terms and “AND” between keywords. Initially, the strategy was structured for the PubMed database, using the Medical Subject Headings (MeSH) descriptors and keywords, and then adapted for each of the databases searched. There were no time or language restrictions on the publications.
The search strategy developed in the PubMed database was as follows: (“infant, newborn”[MeSH Terms] OR “Newborn Infant”[All Fields] OR “Newborn Infants”[All Fields] OR “Newborns”[All Fields] OR “Newborn”[All Fields] OR “Neonate”[All Fields] OR “Neonates”[All Fields] OR “infant, premature”[MeSH Terms] OR “Premature Infant”[All Fields] OR “Preterm Infants”[All Fields] OR “Preterm Infant”[All Fields] OR “Premature Infants”[All Fields] OR “Neonatal Prematurity”[All Fields] OR “Preterm”[All Fields] OR “infant, extremely premature”[MeSH Terms] OR “Extremely Premature”[All Fields] OR “Extremely Premature Infant”[All Fields] OR “Extremely Preterm Infants”[All Fields] OR “Extremely Preterm Infant”[All Fields] OR “Extremely Premature Infants”[All Fields] OR “infant, extremely low birth weight”[MeSH Terms] OR “Extremely Low Birth Weight Infant”[All Fields] OR “Extremely Low Birth Weight Infants”[All Fields] OR “infant, very low birth weight”[MeSH Terms] OR “very low birth weight infant”[All Fields] OR “very low birth weight infants”[All Fields] OR “very low birth weight infant”[All Fields] OR “very low birth weight infants”[All Fields] OR “Very Low Birth Weight”[All Fields] OR “infant, low birth weight”[MeSH Terms] OR “low birth weight infant”[All Fields] OR “low birth weight infants”[All Fields] OR “low birth weight infant”[All Fields] OR “low birth weight infants”[All Fields] OR “Low Birth Weight”[All Fields] OR “Low Birth Weights”[All Fields] OR “infant, small for gestational age”[MeSH Terms] OR “Small for Gestational Age”[All Fields] OR “Term Birth”[MeSH Terms] OR “Term Births”[All Fields] OR “Fullterm Birth”[All Fields] OR “Fullterm Births”[All Fields] OR “infant, postmature”[MeSH Terms] OR “Postmature Infant”[All Fields] OR “Postmature Infants”[All Fields] OR “Neonatal”[All Fields] OR “intensive care units, neonatal”[MeSH Terms] OR “Neonatal Intensive Care Unit”[All Fields] OR “Neonatal Intensive Care Units”[All Fields] OR “Neonatal Intensive Care”[All Fields] OR “Neonatal ICU”[All Fields] OR “Neonatal ICUs”[All Fields]) AND (“catheterization, peripheral”[MeSH Terms] OR “Peripherally Inserted Central Catheter”[All Fields] OR “Peripherally Inserted Central Catheters”[All Fields] OR “PICC”[All Fields] OR “PICCs”[All Fields] OR “Peripherally Inserted Central Catheter Line”[All Fields] OR “Peripherally Inserted Central Catheter Lines”[All Fields] OR “PICC Line”[All Fields] OR “PICC Lines”[All Fields]) AND (“Complications”[MeSH Subheading] OR “Complication”[All Fields] OR “Treatment Failure”[MeSH Terms] OR “Treatment Failures”[All Fields] OR “PICC Failure”[All Fields] OR “PICC Complication”[All Fields] OR “PICC Complications”[All Fields] OR “Infections”[All Fields] OR “Infection”[All Fields] OR “Catheter-Related Infections”[MeSH Terms] OR “catheter related infection”[All Fields] OR “catheter related infection”[All Fields] OR “Central Line-Associated Bloodstream Infection”[All Fields] OR “CLABSI”[All Fields] OR “Central Line-Associated Bloodstream Infections”[All Fields] OR “Bloodstream Infection”[All Fields] OR “Bloodstream Infections”[All Fields] OR “Catheter-Associated Bloodstream”[All Fields] OR “Catheter-Associated Bloodstream Infections”[All Fields] OR “Central Line Bloodstream Infection”[All Fields] OR “CABSI”[All Fields] OR “CRBSI”[All Fields] OR “Neonatal Nosocomial Infections”[All Fields] OR “Neonatal Nosocomial Infection”[All Fields] OR “Deep Vein Thrombosis”[All Fields] OR “Catheter-Related Deep Vein Thrombosis”[All Fields] OR “Thrombosis”[MeSH Terms] OR “Thromboses”[All Fields] OR “Thrombus”[All Fields] OR “Blood Clot”[All Fields] OR “Blood Clots”[All Fields] OR “Phlebitis”[MeSH Terms:noexp] OR “Phlebitides”[All Fields] OR “Periphlebitis”[All Fields] OR “Adverse Effects”[MeSH Subheading] OR “Adverse Effect”[All Fields] OR “Pericardial effusion”[All Fields] OR “Cardiac Tamponade”[All Fields] OR “Arterial Puncture”[All Fields] OR “Nerve Injury”[All Fields] OR “Nerve Injuries”[All Fields] OR “embolism, air”[MeSH Terms] OR “Air Embolism”[All Fields] OR “Air Embolisms”[All Fields] OR “arrhythmias, cardiac”[MeSH Terms] OR “Cardiac Dysrhythmia”[All Fields] OR “Cardiac Dysrhythmias”[All Fields] OR “Arrhythmia”[All Fields] OR “Arrythmia”[All Fields] OR “Cardiac Dysrhythmia”[All Fields] OR ((“central”[All Fields] OR “centrally”[All Fields] OR “centrals”[All Fields]) AND (“vascular access devices”[MeSH Terms] OR (“vascular”[All Fields] AND “access”[All Fields] AND “devices”[All Fields]) OR “vascular access devices”[All Fields] OR (“vascular”[All Fields] AND “access”[All Fields] AND “device”[All Fields]) OR “vascular access device”[All Fields]) AND (“malposition”[All Fields] OR “malpositioned”[All Fields] OR “malpositioning”[All Fields] OR “malpositionings”[All Fields] OR “malpositions”[All Fields])) OR “Infiltration”[All Fields] OR “Extravasation”[All Fields] OR “Extravasation of Diagnostic and Therapeutic Materials”[MeSH Terms]).
Selection process
After removing duplicates using the Endnote Web software (Clarivate Analytics) ( 20 ) , the lists of references of the studies identified in the databases were exported to the Rayyan online software (Rayyan , Qatar Computing Research Institute) ( 21 ) .
The study selection process was carried out in two phases. In the first one, two reviewers (L.O.B.; G.B.) independently read the titles and abstracts of the studies identified in the databases, applying the eligibility criteria. In Phase 2, the reviewers (L.O.B.; G.B.) again applied the inclusion criteria after reading the studies in full. The disagreements were solved through discussion between them, and a third reviewer (A.S.M.) was only resorted to when they did not reach a consensus.
Data collection process
Both reviewers (L.O.B.; G.B.) extracted the following data from the studies selected in phase 2: characteristics of the study (author, year of publication, country, study objectives and main conclusions) and of the sample (number of NBs and catheters gestational age and birth weight, corrected gestational age or days of life and weight at the time of PICC insertion), insertion technique performed and comparator, primary and secondary outcomes.
The data collected were organized in Microsoft Word ® tables and the outcomes were entered into Microsoft Excel ® by a reviewer, with independent cross-checking by another. Subsequently, the data were transported to the R software, version 4.2.3.
Outcomes
The rates of general and specific PICC-related complications were considered as primary outcomes. The definition of complications was based on the terms described in the INS set of good practices (2021), as well as on what it considers as complications related to the insertion technique: arterial puncture, cardiac arrhythmias, nerve injury, air embolism and primary malpositioning of central vascular access devices. The catheter-related complications were catheter-associated deep vein thrombosis, secondary malpositioning (intra- or extra-vascular catheter tip migration), phlebitis, infiltration and extravasation, central line-associated bloodstream infection, occlusion, catheter rupture, and catheter-associated skin lesion ( 11 ) . These latter complications that occur during PICC permanence were added because they have been described as preventable depending on the insertion technique used ( 11 ) . In addition to that, as only studies with changes exclusively in the insertion technique between the groups monitored were included, with no difference in the material used or in the PICC care and maintenance procedures, it can be stated that these outcomes also analyzed by the authors in these studies would only be related to the insertion techniques used. The different nomenclatures used by the authors of the studies to define the complications were standardized according to the description proposed in the INS set of good practices ( 11 ) .
The secondary outcomes collected from the studies that had these data were as follows: Overall Success Rate (OSR) or number of PICCs successfully introduced in all insertion attempts; success rate of the first puncture; number of punctures; and catheter dwell time.
Risk of bias corresponding to the studies included
The risk of bias assessment of the randomized clinical trials included was performed by two reviewers, using the Risk of Bias 2 (RoB2) tool ( 17 ) developed by the Cochrane Collaboration. In turn, the non-randomized clinical trials were evaluated using the Risk of Bias In Non-Randomised Studies of Interventions (ROBINS-I) tool, also developed by the Cochrane Collaboration ( 22 ) .
Effect measures
The data extracted and the results found were expressed by means of relative and absolutes frequencies or through mean values and standard deviations. For binary outcomes, the effect measure used was Relative Risk (RR) and, for the continuous outcome, the Means Difference (MD). All results were reported with their respective 95% confidence intervals (CIs). The figures and graphs were performed in the statistical program (R Statistics Software).
Synthesis methods
The outcome data were transported to the R Statistics Software, version 4.2.3, using the meta version 6.2-1 and netmeta version 2.8-1 packages (The R Foundation, Vienna, Austria). For each outcome analyzed, a different number of studies directly compared new insertion techniques (IC-ECG, formula, etc.) to the puncture technique guided by anatomical landmarks (common comparator). An intervention meta-analysis was carried out with the studies considered homogeneous regarding study design, characteristics of the sample and insertion technique performed, in which a ≤0.05 significance level was considered. The common comparator found in each study allowed for a simultaneous comparison of all treatments of interest (insertion techniques) through a network meta-analysis. The analyses were performed according to the frequentist approach, using the random effects model, with the Mantel-Haenzel method for binary outcomes and the inverse variance method for the continuous outcome. Heterogeneity was evaluated according to I 2 , based on the classification suggested by PRISMA ( 18 ) .
To sort the treatments evaluated in each network meta-analysis into a ranking, the P-score was estimated, which is based on the point estimate and the standard error of each estimate included in the network meta-analysis and measures the magnitude of the certainty that one treatment is better than another. This score varies from 0 to 1, and values close to 1 indicate superiority of the treatment under evaluation ( 23 ) .
The studies carried out only with preterm infants were excluded from the network meta-analyses, as they deal with a peculiar and differentiated sample from those used in studies that combine preterm infants with full-term NBs, thus avoiding intransitivity ( 17 ) . Preterm infants have immature skin and vascular system anatomy and physiology, lower immunity, higher rates of infections and mechanical complications ( 4 , 24 - 28 ) and also a higher chance of proper tip positioning ( 29 ) .
It is noted that the network meta-analysis had not been provided for in the protocol of this review; however, considering the feasibility of this analysis and the importance/relevance of the evidence it provides, it was decided to perform it. Such decision was based on the analysis of the data from the eligible studies, when presence of a control group in common among the insertion techniques evaluated in the included studies was verified. In addition to that, the network meta-analysis is the method that best answers the guiding question of this review.
Evaluation of publication bias
A search on Clinicaltrials.gov was carried out for unpublished results of clinical trials as a way to reduce the risk of bias due to lack of results in a synthesis ( 17 ) . It was not possible to generate the funnel plot because this feature requires a minimum of 10 tests to ensure adequate power to detect asymmetries ( 17 ) .
Certainty of the evidence assessment
The Grading of Recommendations, Assessment, Development, and Evaluation Working Group (GRADE) approach was used to assess the quality and certainty of the evidence for each outcome of each comparison ( 30 ) , with downgrading or elevation by one or two points based on judgment criteria. The web version of GRADEpro was used to present the conclusions for the main outcomes of the direct comparisons (GRADEpro GDT; GRADE Working Group, 2022). The evaluation regarding certainty of the evidence of the effect estimates found in the network meta-analysis was carried out in four stages with the aid of a specific form prepared in Microsoft Excel ®: 1) Presentation of the direct and indirect estimates of each comparison of interest; 2) Classification of the certainty of the evidence of each direct and indirect estimate; 3) Presentation of the effect estimates corresponding to the network meta-analysis of the comparison of interest; and 4) Classification of the certainty of the evidence corresponding to the network meta-analysis estimates ( 31 ) . In these stages, intransitivity of the indirect estimates, incoherence (or inconsistency, as PRISMA calls it) and imprecision of the network were evaluated ( 32 - 34 ) .
Results
A total of 2,697 studies were identified in the databases and grey literature, of which 1,294 were duplicates, resulting in 1,403 articles selected for reading their titles and abstracts. A detailed flowchart of the selection, exclusion and inclusion of the studies, adapted from PRISMA, is shown in Figure 1 . It should be added that seven of the 100 records selected in the Grey Literature were duplicates; the others were screened for titles and abstracts, but none were included in this review.
- Flowchart corresponding to the literature search and selection criteria adapted from PRISMA ( 18 )
Eight studies were included in this review, with a total sample of 1,126 NBs. Five were from China ( 14 , 28 , 35 - 37 ) , one from the United States ( 38 ) , one from India ( 39 ) and one from Brazil ( 40 ) . The publication period ranged from 2013 to 2021, and one study was only available in the Chinese language ( 35 ) .
Regarding the study designs, six were randomized controlled trials ( 14 , 35 - 36 , 38 - 40 ) and two were non-randomized trials ( 28 , 37 ) .
The samples varied within the neonate population, three studies only evaluated the insertion techniques in preterm ( 28 ) and very preterm/extreme preterm ( 38 - 39 ) NBs and four assessed the insertion techniques in preterm and full-term NBs ( 14 , 35 , 37 , 40 ) . One study only cited the mean weight of 2,500 g on the insertion day ( 36 ) .
The PICC insertion techniques in NBs found in the studies included were the following: intracavitary electrocardiogram (IC-ECG) to guide the tip ( 14 , 35 ) ; intracavitary electrocardiogram with ultrasound for vascular visualization (IC-ECG/USG) ( 28 , 37 ) ; real-time ultrasound (USGRT) to visualize the tip during insertion and guiding it ( 38 - 39 ) ; modified anatomical landmark (AL), in which the intervention took place with measurement of the catheter size to be inserted with a different anatomical framework ( 40 ) ; formula use, in which an equation determines the catheter length that must be inserted associated with performing a warm compress for 15 minutes at the insertion site before the puncture ( 36 ) ; and puncture guided by anatomical landmarks, characterized by blind puncture (without the aid of technologies), measurement by arm (the number of catheter centimeters to be inserted is predetermined by a measurement performed on the body surface from the probable insertion site to the superior or inferior vena cava) and visualization of the tip by x-ray ( 14 , 28 , 35 - 40 ) , which was the control group of all studies. In other words, the comparator/control in all studies was the same technique, which led the network to a star-shaped geometry. This means that all new techniques were compared to a common comparator, without direct comparison between them, but indirect.
The risk of bias in the studies included is detailed in Figure 2 .
- Risk of bias assessment applied to the studies using the RoB2 (Risk of Bias 2) tool (above) and ROBINS-I (Risk of Bias In Non-randomized Studies of Interventions) (below). Brasília, DF, Brazil, 2023
The randomized trials showed some concerns regarding the randomization process due to some differences in the characteristics of the participants ( 38 ) , lack of detailed information in the articles ( 36 ) or 1:1 allocation ( 14 ) . It was not possible for the professionals who applied the intervention to be blinded, as they would need to know what the intervention was to apply it, with the exception of one study ( 40 ) . In a research study that used USGRT ( 38 ) , some deviations from the intended interventions that may have affected the outcomes were observed, with unexplained insertion failures that can be directly related to the intervention, even changing the number of participants in both groups. Although the study protocol of one of the publications was not identified ( 39 ) , which led the bias domain of the reported results to be judged as “some concerns”, this study was evaluated as low risk of bias because it was well designed and contained the authors’ statement that all interventions and analyses were carried out according to the plan before initiating the study. Two publications did not report whether or not those responsible for evaluating the outcomes knew which group they were evaluating ( 35 - 36 ) .
The non-randomized trials obtained all the information from their control group through retrospective data, and the articles had some questions from the domains answered as “not reported” ( 28 , 37 ) . For example, there was no information on whether the professionals who evaluated the outcomes knew which group the participants belonged to, which may have mainly influenced measurement of the primary tip malpositioning, the only complication measured in the second study ( 37 ) . This same study ( 37 ) was considered at critical risk of bias because there were differences in the characteristics and number of participants between the groups with no control of the measured confounding factors; in addition, the participants seemed to have had different follow-ups.
The characteristics of the primary studies included in the review and their results are described in Figure 3 .
Not all outcomes were assessed in all the studies included. Those evaluated in more than one included study, with a similar sample and more than one insertion technique, were analyzed in the network. In the structure or geometry of each network, the control group was the only one directly compared to the other insertion techniques and these were compared indirectly with each other, precisely for having this common comparator. Thus, for all outcomes in which network meta-analysis was possible, its geometry was the same. The network structure of all outcomes that allowed the network meta-analysis is graphically represented in Figure 4 . It is noted that, in the network geometry circles represent interventions, whose sizes correspond to the number of each sample, and straight lines are direct comparisons between insertion techniques, with greater thickness the more studies that carried out that comparison.
- Network geometry of all outcomes that allowed performing the network meta-analysis. Brasília, DF, Brazil, 2023
In relation to the primary outcomes, one of them was general complications, which corresponded to the total number of complications reported by each study, and may refer to two or more complications, depending on the research objective and the newborn’s follow-up length. Two studies did not verify this outcome ( 37 - 38 ) , as they were the only ones that monitored their samples only until the tip location was confirmed and not until the PICC was removed (see device dwell time), as in the others. As was the case with other complications, primary tip malpositioning was not mentioned in the “general complications” outcome by any author of the studies included. Figure 5 shows the results related to the general complications regarding the meta-analysis with direct and indirect comparisons.
- Forest graphs showing the effect of the insertion techniques on the “general complications” outcome, both from direct comparisons (above) and those carried out on the network (below). Brasília, DF, Brazil, 2023
The “phlebitis” complication was analyzed with an intervention meta-analysis and in a network with studies with the same sample. In the intervention with the two studies that used IC-ECG in PICC insertion ( 14 , 35 ) , it was found that this technique might significantly reduce the phlebitis risk by up to 81% (RR: 0.19; 95% CI: 0.06-0.65). In the network meta-analysis, when compared to the control, IC-ECG remained the only insertion technique capable of significantly reducing this complication.
Primary malpositioning of the PICC tip was an outcome not directly measured in two studies ( 35 - 36 ) . All interventions (IC-ECG, IC-ECG/USG, USGRT and modified ARL) reduced the risk of primary tip malpositioning, with an estimated large magnitude, when compared to the control. An intervention meta-analysis was carried out with two studies that compared USGRT to the control group ( 38 - 39 ) , with RR of 0.47 (95% CI: 0.31-0.72). However, as these trials ( 38 - 39 ) were carried out with very premature and extremely premature newborns, it was not possible to include them in the network meta-analysis carried out with other insertion techniques. In this network, it was also found that IC-ECG/USG reduced the risk of primary malpositioning when compared to modified AL (RR: 0.31; 95% CI: 0.10-0.96).
Thus, the insertion techniques significantly reduced general complications, phlebitis and primary tip malpositioning. The ranking carried out according to the P-score results of the most effective techniques in reducing those complications is shown in Figure 6 . In this figure, relative risks (RRs) below 1 favor the intervention defined in the column for the network meta-analysis results (lower triangle) and the intervention defined in the row for paired meta-analysis results (upper triangle). Thus, it is verified that the most effective insertion techniques in reducing general complications, phlebitis and primary tip malpositioning were IC-ECG (P-score 0.8399), formula (P-score 0.7562) and IC-ECG/USG (P-score 0.8863), respectively.
- League tables showing the ranking of the most effective insertion techniques in reducing general complications, phlebitis and primary tip malpositioning with the respective relative risks resulting from the comparisons. Brasília, DF, Brazil, 2023
Arrhythmia was investigated through an intervention meta-analysis carried out with the only two studies ( 14 , 35 ) that measured this outcome, verifying a reduction in its risk with the use of the IC-ECG insertion technique (RR: 0.09; 95% CI: 0.01-0.71).
With the “infection”, “secondary tip malpositioning” and “catheter-associated deep vein thrombosis” outcomes, an intervention meta-analysis and a network meta-analysis were performed, with lack of statistical significance in the paired and network effect estimates. A ranking of the most effective insertion techniques in terms of reducing the aforementioned complications was carried out and, in it, the formula was considered the best.
Two complications mentioned in the 2021 INS manual were not found in any study included in this review: inadvertent arterial puncture; and air embolism ( 11 ) . Another two complications were mentioned in the studies included: occlusion; and catheter-associated skin lesion. The meta-analyses carried out for these last two outcomes (network for occlusion and intervention for skin lesions) did not show a significant reduction depending on the insertion technique used.
As for the secondary outcomes, the Overall Success Rate (OSR) was above 80% in a study that used USGRT (92.5% x 85%) ( 39 ) . An intervention meta-analysis was performed with this outcome with only two homogeneous studies that used USGRT ( 38 - 39 ) in their experimental group, resulting in RR: 0.90; 95% CI: 0.60-1.36.
The study with the highest success rates in the first puncture was the one that used the formula as insertion technique (96.92% x 72.31%) ( 36 ) , whereas the rate reached 37.5% with the modified AL ( 40 ) .
Regarding the catheter dwell time, the formula ( 36 ) and USGRT ( 39 ) showed that the experimental group had significantly longer dwell time when compared to the control (MD: 2.35; 95% CI: 2.07-2.63 and MD: 0.9; 95% CI: 0.60-1.10, respectively). The IC-ECG insertion technique reduced the mean dwell time (MD: -0.23; 95% CI: -1.21.-0.75).
Certainty of the body of evidence was evaluated through GRADE. No assessed outcome presented “high” certainty of its evidence. Direct and indirect comparisons were evaluated for each outcome, so that a result regarding certainty of the evidence from the network meta-analyses was constructed based on the assessment of the incoherence and imprecision of such networks. Inconsistency in the network, as GRADE calls it, is nonexistent since, for each outcome, there were either direct comparisons (techniques x control) or indirect comparisons (between techniques in the network), but never a combination of direct and indirect comparisons. The evaluation results are shown in Figure 7 .
- Results of the certainty of the evidence assessments from direct/indirect estimates and network meta-analysis, according to the Grading of Recommendations, Assessment, Development, and Evaluation Working Group (GRADE), and carried out on the outcomes (n=11) with their respective comparisons. Brasília, DF, Brazil, 2023
Discussion
This review is the first to verify the effectiveness of different PICC insertion techniques in preventing the occurrence of complications in newborns. With the synthesis, evaluation and careful combination of the eight studies included through paired and network meta-analyses, it was possible to verify which insertion technique, among those identified, is most effective in reducing certain complications associated with PICC central vascular access devices. In this way, there was a significant reduction in the risk of general complications, arrhythmias, phlebitis and primary malpositioning of the PICC tip, as well as changes in the catheter dwell time depending on the insertion technique used. Infection, infiltration/leaks, secondary tip malpositioning, catheter rupture, thrombosis, occlusion, skin injury and OSR were influenced by the insertion techniques and the majority with an absolute reduction, but without statistical significance and presenting effect estimates with very low certainty of the evidence.
Preventing complications can reduce morbidity, the need for additional procedures and costs ( 41 ) . Good practices during PICC insertion in newborns can mitigate unnecessary exposure of the infants, multiple venipunctures and risk of inappropriate catheter positioning, in addition to improving the insertion success rate ( 42 - 43 ) .
In this review, the use of IC-ECG was associated with a significantly lower and more effective risk of general complications phlebitis and primary tip malpositioning and with a reduction in cardiac arrhythmias, all with moderate certainty of the evidence. It was also the best technique to reduce the catheter dwell time, especially when compared to the technique that uses the formula. With such moderate certainty of the findings, it can be stated that IC-ECG is an insertion technique that should be used in the clinical practice due to its effectiveness in preventing important complications.
A Chinese systematic review and meta-analysis carried out with local randomized clinical trials found that IC-ECG reduced the risk of phlebitis (OR: 0.33 - 95% CI: 0.19-0.56, p <0.001) and the total complications (OR: 0.23 - 95% CI: 0.16-0.33, p <0.001), in addition to increasing the accuracy of optimal tip location (OR: 5.37 - 95% CI: 3.80-7.59, p <0.001) ( 44 ) . This meta-analysis corroborates the results herein presented, showing the effectiveness of IC-ECG in reducing arrhythmias, general complications and phlebitis, in addition to primary tip malpositioning and its possible consequences. This is because research studies and sets of good practices have associated increased complication rates with non-central PICC tips, especially occlusions, leaks, other mechanical complications, phlebitis and non-elective failure/removal ( 2 , 11 , 29 , 41 , 45 - 46 ) . The complication rate for non-central PICCs is up to 200% higher when compared to central ones ( 29 ) . In other words, an insertion technique capable of preventing primary malpositioning of the central vascular access device will reduce the occurrence of these other complications mentioned above, which can be extremely harmful.
Phlebitis is influenced by the PICC insertion technique, as it can be caused when the tip is not central ( 2 , 35 , 47 ) (smaller caliber vessels are more subjected to chemical irritation and constant friction from the catheter). It can also be associated with other factors such as a very rigid catheter, inadequate puncture technique, inappropriate puncture site due to constant movement of the limb (especially upper limbs), infection and medication incompatibility ( 11 , 35 , 48 - 49 ) . Therefore, as the IC-ECG insertion technique most effectively reduced tip malpositioning, it is no surprise that it is also the best in reducing the risk of phlebitis.
Regarding the dwell time, it can be stated that IC-ECG was not effective in reducing it when compared to the control, although it reduced it significantly when compared to the formula. This result is different from the one found in the Chinese systematic review and meta-analysis, in which using IC-ECG during insertion reduced this outcome when compared to the control (MD=5.86, 95% CI: 16.36-4.65, p =0.00) ( 44 ) . It is noted that the dwell time during which the catheter is in place should only be discussed if other data that were not collected and were not in the studies included in this review are added. This is because interpretation of the decrease in DT can either be considered positive, if this was due to a reduction in complications and consequent completion of intravenous therapy more quickly, for example, or as negative, if it was due to more early catheter removals.
The insertion technique that uses a formula based on the newborn’s weight to predict the size (in centimeters) of the catheter to be inserted ( Figure 3 ) proved to be superior to the others by significantly increasing the dwell time (moderate certainty of the evidence) and reducing the risk of phlebitis (low confidence in the effect). This low certainty of the evidence in relation to phlebitis leads to the consideration that the most effective technique in reducing its risk was in fact IC-ECG, in which confidence is moderate, with more precise estimates. Furthermore, it was the second best technique in reducing the risk of general complications and the one with the best success rate at the first puncture attempt, less need for PICC adjustments, hospitalization time and pain ( 36 ) .
Other research studies with newborns also resulted in formulas that predict the size of the catheter to be inserted, based on the infants’ physical characteristics such as weight, height and gestational age, ensuring a more accurate way of centrally locating the PICC tip ( 25 , 50 ) .
In the study using the formula, the saphenous vein was punctured, almost always on the first attempt and by trained and experienced nurses ( 36 ) . The experience of a vascular nursing team is important for successful insertion and safety in terms of complication rates ( 28 , 51 ) .
It is noted that, in addition to the warm compress used in research with the formula ( 36 ) , other studies tested different strategies to keep the NBs warm and veins vasodilated during PICC insertion, such as using of a thermal blanket ( 52 ) and placing the NB in a crib with radiant heat during insertion of this device ( 4 ) . These tactics and the results that were found as for the number of insertions on the first puncture in the study that used the warm compress (96.92%, n=63) ( 36 ) and a heated crib (77.72%, n=457) ( 4 ) show the need to actually employ measures to prevent newborn hypothermia during prolonged procedures such as PICC insertion.
IC-ECG associated with USG for vascular visualization was considered the best insertion technique in reducing primary tip malpositioning according to the network meta-analysis ranking. However, it should be considered that the studies that used it were non-randomized, with higher than moderate risk of bias and very low and low certainty of the evidence. Therefore, it is correct to say that the most effective technique in reducing the risk of primary malpositioning was IC-ECG alone and that IC-ECG/USG was the second best, surpassing modified AL and control. The other outcomes measured in the studies that used IC-ECG/USG ( 28 , 37 ) also resulted in estimates with a significant uncertainty degree and without statistical significance. This shows that, with regard to the prevention of PICC-associated complications, IC-ECG/USG is either not advantageous in the clinical practice for this purpose or requires randomized studies to be carried out to more reliably verify the existence of benefits or not.
However, employing devices to assist with visualization and venipuncture can be useful, as newborns have narrower veins that are immature and vulnerable to ruptures ( 1 , 25 - 26 ) . In the research with modified AL there was also failure in the puncture of 18 newborns for PICC insertion due to venous fragility ( 40 ) .
The INS recommends using USG to evaluate the vein that will be punctured regarding its caliber (the catheter cannot exceed 45% of the vessel), whether there are abnormalities such as occlusions and thrombosis and to identify positioning of the device tip ( 11 ) . In a descriptive survey carried out by nurses from Iran with 30 newborns, a USG device was used for vascular assessment and visualization during the PICC insertion puncture. There was an increase in the success rate at the first (68% USG group x 60% conventional group) and second (50% x 40%) attempts, although not statistically significant ( 53 ) . An American retrospective study whose objective was to describe the use of USG in PICC insertion found a success rate of 100% in a sample comprised by 10 newborns with multiple unsuccessful vascular access attempts ( 54 ) .
The insertion technique that used modified AL ( 40 ) reduced the risk of general complications and primary malpositioning with statistical significance (low and moderate to very low certainty of the evidence, respectively).
A retrospective study carried out with 588 NBs found low prevalence of complications associated with the catheter (10.71%) and also carried out measurements up to the right sternoclavicular junction, such as the study with modified AL ( 40 ) , stating that the traditional measurement ended up positioning the PICC tip too deep ( 4 ) . Therefore, when it comes to NBs, it is imperative to carry out a prior measurement of the catheter length to be introduced based on anatomical landmarks, differently from what is recommended by the INS for other populations in the upper limbs (puncture site: right sternoclavicular region and third intercostal space) ( 11 ) .
USGRT proved to be effective in reducing primary tip malpositioning and increasing catheter dwell time significantly and with low and moderate certainty in the findings, respectively. It did not present significant effect estimates for the other complications and even obtained opposite estimates, with no significance and very low certainty in some cases, such as general complications, infection and secondary tip malpositioning. It must be considered that the studies which used this insertion technique ( 38 - 39 ) were carried out with very premature and extremely premature newborns, whose peculiarities may have led to a tendency for an increase in some complications or to lack of a significant reduction in others, as was the case with the other techniques. Furthermore, they were the studies with the smallest sample size.
A prospective cohort monitored PICC insertion in the lower limbs of 166 newborns in their experimental group with USGRT and compared it to 141 newborns in whom this technology was not used. As in this review, there was a significant reduction in primary tip malpositioning, as the need for catheter adjustments in the USGRT group was much lower (10.84% x 65.95%, p <0.001) and there was no significant difference between the groups in other complications (phlebitis, occlusion, bacteremia and rupture) ( 12 ) .
A recent meta-analysis also validates the results found in this review by verifying that USG is excellent for locating the PICC tip in a neonatal unit when compared to x-ray, with 95.2% sensitivity and 71.4% specificity, and that it should be combined with x-ray when it is not possible to position the tip using this method ( 55 ) .
With the negative results of the studies that used USGRT, it is clear that it is imperative to establish protocols ( 56 - 57 ) , as well as adequate training and experience of professionals who manipulate the equipment ( 57 ) . When it comes to newborns and children, the need for these requirements was highlighted as a disadvantage of USG, as well as the difficulties of some units having a device available 24 hours a day ( 57 - 59 ) .
Several changes have been made to the materials and procedures related to PICC insertion and maintenance in newborns and the use of technologies to assist punctures and, in this sense, central positioning of the PICC has been most recommended in the current literature ( 11 , 56 , 60 - 61 ) . These technologies aim at reducing complication rates and, consequently, newborns’ pain, suffering and morbidity and mortality ( 60 ) . However, none of the recently published Brazilian studies ( 26 , 42 , 62 ) have observed the use of such technologies (IC-ECG, USGRT, USG for vascular visualization, etc.), which leads us to reflect on what reasons have contributed to the fact that they are not being used and studied in Brazil.
This systematic review and meta-analysis (paired and in network) verified the effectiveness of insertion techniques in preventing the occurrence of PICC-related complications in newborns, which can even lead to sequelae and death. It included nearly six insertion techniques, more than 1,000 NBs in its sample, and used with methodological rigor and differentiated analyses. The studies included were all randomized and non-randomized controlled clinical trials, evaluated together as already recommended in the literature ( 63 ) , the majority of which had a sample size greater than 100 newborns. This fact can be considered an advantage, as clinical trials related to intravenous catheters in newborns generally have a mean sample size of less than 100 participants ( 64 ) .
However, this review should be interpreted in the context of some limitations. A small sample of comparative studies was evaluated, with the possibility of carrying out few intervention meta-analyses. In addition to that, no study compared different technologies to each other for PICC insertion, the risk of bias of most of the studies included was judged as “Some concerns”, and no outcome was assessed with high certainty of the evidence.
Conclusion
This review showed that the insertion techniques are capable of preventing PICC-related complications in newborns; however, it is not yet possible to assert which is the most effective for all. This is because each technique included in this review showed greater effectiveness for different complications, even though IC-ECG reduced most of them.
All techniques other than anatomical landmark-guided puncture (control) reduced primary tip malpositioning, but IC-ECG was the most effective in reducing it along with general complications, phlebitis and catheter dwell time, also considerably and significantly reducing arrhythmias. The formula showed greater effectiveness in increasing catheter dwell time and was the second best in reducing general complications. It was also considered superior with very low certainty of the evidence and no statistical significance in reducing the risks of infection, secondary tip malpositioning and thrombosis. USGRT did not show any reduction in other complications, it increased catheter dwell time and found a tendency for some to increase without significance.
There is a need for more randomized controlled clinical trials with larger samples that compare insertion techniques in terms of complication rates. Cost-effectiveness studies should also be operationalized so that public policies may be developed to reduce failures in intravenous therapy for patients of all ages and provide greater safety. Every effort must be directed towards investigating more strategies, techniques and technologies so that PICC use, essential for newborns, becomes safer for this vulnerable population.
References
-
1. Vilar AMA, Oliveira MF, Mattos CM, Silvino ZR. Interventional ultrasound for implantation and monitoring of peripherally inserted central venous catheter: scoping review. Rev Enferm UERJ. 2020;28:e50366. https://doi.org/10.12957/reuerj.2020.50366
» https://doi.org/10.12957/reuerj.2020.50366 -
2. Yu X, Yue S, Wang M, Cao C, Liao Z, Ding Y, et al. Risk factors related to peripherally inserted central venous catheter nonselective removal in neonates. Biomed Res Int. 2018;2018:3769376. https://doi.org/10.1155/2018/3769376
» https://doi.org/10.1155/2018/3769376 -
3. Bomfim JMS, Passos LS, Santos FS, Santos LH, Silva JC. Challenges in maintenance of the neonate peripheral insert central catheter. Cuid Enferm [Internet]. 2019 [cited 2021 Aug 30];13(2):174-9. Available from: http://www.webfipa.net/facfipa/ner/sumarios/cuidarte/2019v2/174.pdf
» http://www.webfipa.net/facfipa/ner/sumarios/cuidarte/2019v2/174.pdf -
4. Li R, Cao X, Shi T, Xiong L. Application of peripherally inserted central catheters in critically ill newborns experience from a neonatal intensive care unit. Medicine. 2019;98:32(e15837). https://doi.org/10.1097/MD.0000000000015837
» https://doi.org/10.1097/MD.0000000000015837 -
5. Pires ABM, Lima AFC. Direct cost of peripheral catheterization by nurses. Rev Bras Enferm. 2019;72(1):88-94. https://doi.org/10.1590/0034-7167-2018-0250
» https://doi.org/10.1590/0034-7167-2018-0250 -
6. Patil K, Dhaded SM, Bhandankar M. A 1-year study on association between peripherally inserted central catheter tip position and complications in neonates. J Indian Assoc Pediatr Surg. 2020;25(5):276-9. https://doi.org/10.4103/jiaps.JIAP8719
» https://doi.org/10.4103/jiaps.JIAP8719 -
7. van Rens MFPT, Bayoumi MAA, van de Hoogen A, Francia ALV, Cabanillas IJ, van Loon FHJ, et al. The ABBA project (Assess Better Before Access): a retrospective cohort study of neonatal intravascular device outcomes. Front Pediatr. 2022;10:980725. https://doi.org/10.3389/fped.2022.980725
» https://doi.org/10.3389/fped.2022.980725 -
8. Ullman AJ, Cooke ML, Mitchell M, Lin F, New K, Long DA, et al. Dressings and securement devices for central venous catheters (CVC). Cochrane Database Syst Rev. 2015;2015(9):CD010367. https://doi.org/10.1002/14651858.CD010367.pub2
» https://doi.org/10.1002/14651858.CD010367.pub2 -
9. Schults JA, Kleidon T, Petsky HL, Stone R, Schoutrop J, Ullman AJ. Peripherally inserted central catheter design and material for reducing catheter failure and complications. Cochrane Database Syst Rev. 2019;2019(7):CD013366. https://doi.org/10.1002/14651858.CD013366
» https://doi.org/10.1002/14651858.CD013366 -
10. Duwadi S, Zhao Q, Budal BS. Peripherally inserted central catheters in critically ill patients - complications and its prevention: A review. Int J Nurs Sci. 2018;6(1):99-105. https://doi.org/10.1016/j.ijnss.2018.12.007
» https://doi.org/10.1016/j.ijnss.2018.12.007 -
11. Gorski LA, Hadaway L, Hagle ME, Broadhurst D, Clare S, Kleidon T, et al. Infusion therapy standards of practice. J Infus Nurs. 2021;44(suppl 1):S1-S224. https://doi.org/10.1097/NAN.0000000000000396
» https://doi.org/10.1097/NAN.0000000000000396 -
12. Huang HC, Su LT, Liu YC, Chang HY, Ou-Yang MC, Chung MY, et al. The role of ultrasonography for detecting tip location of percutaneous central venous catheters in neonates-a single-center, prospective cohort study. Pediatr Neonatol. 2021;62(3):265-70. https://doi.org/10.1016/j.pedneo.2021.01.006
» https://doi.org/10.1016/j.pedneo.2021.01.006 -
13. Yang L, Bing X, Song L, Na C, Minghong D, Annuo L. Intracavitary electrocardiogram guidance for placement of peripherally inserted central catheters in premature infants. Medicine. 2019;98(50):e18368. https://doi.org/10.1097/MD.0000000000018368
» https://doi.org/10.1097/MD.0000000000018368 -
14. Ling Q, Chen H, Tang M, Qu Y, Tang B. Accuracy and safety study of intracavitary electrocardiographic guidance for peripherally inserted central catheter placement in neonates. J Perinat Neonatal Nurs. 2019;33(1):89-95. https://doi.org/10.1097/JPN.0000000000000389
» https://doi.org/10.1097/JPN.0000000000000389 -
15. Zaghloul N, Watkins L, Choi-Rosen J, Perveen S, Kurepa D. The superiority of point of care ultrasound in localizing central venous line tip position over time. Eur J Pediatr. 2019;178(2):173-9. https://doi.org/10.1007/s00431-018-3269-9
» https://doi.org/10.1007/s00431-018-3269-9 -
16. Walker G, Chan RJ, Alexandrou E, Webster J, Rickard C. Effectiveness of electrocardiographic guidance in CVAD tip placement. Br J Nurs. 2015;24(14):S4, S6, S8-12. https://doi.org/10.12968/bjon.2015.24.Sup14.S4
» https://doi.org/10.12968/bjon.2015.24.Sup14.S4 -
17. Higgins JPT, Thomas J, Chandler J, Cumpston M, Li T, Page MJ, et al., editors. Cochrane handbook for systematic reviews of interventions, version 6.3 (updated February 2022) [Internet]. [s.l.]: Cochrane; 2022 [cited 2023 Jun 10]. Available from: www.training.cochrane.org/handbook
» www.training.cochrane.org/handbook -
18. Page MJ, McKenzie JE, Bossuyt PM, Boutron I, Hoffmann TC, Mulrow CD, et al. The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. BMJ. 2021;372:n71. https://doi.org/10.1136/bmj.n71
» https://doi.org/10.1136/bmj.n71 -
19. Hutton B, Salanti G, Caldwell DM, Chaimani A, Schmid CH, Cameron C, et al. The PRISMA extension statement for reporting of systematic reviews incorporating network meta-analyses of health care interventions: checklist and explanations. Ann Intern Med. 2015;162(11):777-84. https://doi.org/10.7326/M14-2385
» https://doi.org/10.7326/M14-2385 -
20. EndNote [Software]. London: Clarivate Analytics; 2022 [cited 2022 Jun 01]. Available from: https://endnote.com
» https://endnote.com -
21. Ouzzani M, Hammady H, Fedorowicz Z, Elmagarmid A. Rayyan — a web and mobile app for systematic reviews. Syst Rev. 2016;5:210. https://doi.org/10.1186/s13643-016-0384-4
» https://doi.org/10.1186/s13643-016-0384-4 -
22. Sterne JA, Hernán MA, Reeves BC, Savović J, Berkman ND, Viswanathan M, et al. ROBINS-I: a tool for assessing risk of bias in non-randomised studies of interventions. BMJ. 2016;355:i4919. https://doi.org/10.1136/bmj.i4919
» https://doi.org/10.1136/bmj.i4919 -
23. Rücker G, Schwarzer G. Resolve conflicting rankings of outcomes in network meta-analysis: Partial ordering of treatments. Res Synth Methods. 2017;8(4):526-36. https://doi.org/10.1002/jrsm.1270
» https://doi.org/10.1002/jrsm.1270 -
24. Rabie D, Mostafa MF, Abdel Halim RM, Ezzat OA . Central line-associated bloodstream infection (CLABSI) with three different vascular access in neonatal intensive care unit. Gaz Egypt Paediatr Assoc. 2022;70(16). https://doi.org/10.1186/s43054-022-00108-z
» https://doi.org/10.1186/s43054-022-00108-z -
25. Kim DY, Park HR. Estimating the insertion depth of a peripherally inserted central catheter in newborns using weight and gestational age measurements. J Perinat Neonatal Nurs. 2021;35(4):362-8. https://doi.org/10.1097/JPN.0000000000000585
» https://doi.org/10.1097/JPN.0000000000000585 -
26. Carneiro TA, Nobre KSS, Fontenele FC, Façanha APM, Ferreira RP. Peripherally inserted central catheter in newborns: association of number of punctures, vein, and tip positioning. Rev Esc Enferm USP. 2021;55:e20210043. https://doi.org/10.1590/1980-220X-REEUSP-2021-0043
» https://doi.org/10.1590/1980-220X-REEUSP-2021-0043 -
27. Hugill K, van Rens M. Inserting central lines via the peripheral circulation in neonates. Br J Nurs. 2020 Oct 22;29(19):S12-S18. https://doi.org/10.12968/bjon.2020.29.19.S12
» https://doi.org/10.12968/bjon.2020.29.19.S12 -
28. Xiao AQ, Sun J, Zhu LH, Liao ZY, Shen P, Zhao LL, et al. Effectiveness of intracavitary electrocardiogram-guided peripherally inserted central catheter tip placement in premature infants: a multicentre pre-post intervention study. Eur J Pediatr. 2020;179(3):439-46. https://doi.org/10.1007/s00431-019-03524-3
» https://doi.org/10.1007/s00431-019-03524-3 -
29. Goldwasser B, Baia C, Kim M, Taragin BH, Angert RM. Non-central peripherally inserted central catheters in neonatal intensive care: complication rates and longevity of catheters relative to tip position. Pediatr Radiol. 2017;47(12):1676-81. https://doi.org/10.1007/s00247-017-3939-1
» https://doi.org/10.1007/s00247-017-3939-1 -
30. Schünemann H, Brożek J, Guyatt G, Oxman A, editors. GRADE handbook [Internet]. 2013 [cited 2023 Apr 20]. Available from: https://guidelinedevelopment.org/handbook
» https://guidelinedevelopment.org/handbook -
31. Puhan MA, Schünemann HJ, Murad MH, Li T, Brignardello-Petersen R, Singh JA, et al. A GRADE Working Group approach for rating the quality of treatment effect estimates from network meta-analysis. BMJ. 2014;349:g5630. https://doi.org/10.1136/bmj.g5630
» https://doi.org/10.1136/bmj.g5630 -
32. Brignardello-Petersen R, Bonner A, Alexander PE, Siemieniuk RA, Furukawa TA, Rochwerg B, et al. Advances in the GRADE approach to rate the certainty in estimates from a network meta-analysis. J Clin Epidemiol. 2018;93:36-44. https://doi.org/10.1016/j.jclinepi.2017.10.005
» https://doi.org/10.1016/j.jclinepi.2017.10.005 -
33. Brignardello-Petersen R, Mustafa RA, Siemieniuk RAC, Murad MH, Agoritsas T, Izcovich A, et al. GRADE approach to rate the certainty from a network meta-analysis: addressing incoherence. J Clin Epidemiol. 2019;108:77-85. https://doi.org/10.1016/j.jclinepi.2018.11.025
» https://doi.org/10.1016/j.jclinepi.2018.11.025 -
34. Brignardello-Petersen R, Guyatt GH, Mustafa RA, Chu DK, Hultcrantz M, Schünemann HJ, et al. GRADE guidelines 33: addressing imprecision in a network meta-analysis. J Clin Epidemiol. 2021;139:49-56. https://doi.org/10.1016/j.jclinepi.2021.07.011
» https://doi.org/10.1016/j.jclinepi.2021.07.011 -
35. Tang BZ, Chen CH, Chen H, Ling QY. [RCT of reduction in catheter-related complications by using intracavitary electrocardiogram-assisted guidance in neonatal PICC placement]. Sichuan Da Xue Xue Bao Yi Xue Ban. 2021;52(3):497-502. https://doi.org/10.12182/20210560506
» https://doi.org/10.12182/20210560506 -
36. Wu J, Li J, Li H, Lei X, Liu H. Comparison of formula-based PICC catheterisation versus common method for the treatment of newborns. Int J Clin Pract. 2021;00:e14210. https://doi.org/10.1111/ijcp.14210
» https://doi.org/10.1111/ijcp.14210 -
37. Zhou L, Xu H, Liang J, Xu M, Yu J. Effectiveness of Intracavitary Electrocardiogram Guidance in Peripherally Inserted Central Catheter Tip Placement in Neonates. J Perinat Neonatal Nurs. 2017;31(4):326-31. https://doi.org/10.1097/JPN.0000000000000264
» https://doi.org/10.1097/JPN.0000000000000264 -
38. Katheria AC, Fleming SE, Kim JH. A randomized controlled trial of ultrasound-guided peripherally inserted central catheters compared with standard radiograph in neonates. J Perinatol. 2013;33(10):791-4. https://doi.org/10.1038/jp.2013.58
» https://doi.org/10.1038/jp.2013.58 -
39. Oleti T, Jeeva Sankar M, Thukral A, Sreenivas V, Gupta AK, Agarwal R, et al. Does ultrasound guidance for peripherally inserted central catheter (PICC) insertion reduce the incidence of tip malposition? - a randomized trial. J Perinatol. 2019;39(1):95-101. https://doi.org/10.1038/s41372-018-0249-x
» https://doi.org/10.1038/s41372-018-0249-x -
40. Tomazoni A, Rocha PK, Pedreira MLG, Rodrigues EC, Manzo BF, Santos LM. Methods for measuring venous peripherally inserted central catheters in newborns. Rev Bras Enferm. 2022;75(2):e20210045. https://doi.org/10.1590/0034-7167-2021-0045
» https://doi.org/10.1590/0034-7167-2021-0045 -
41. Jumani K, Advani S, Reich NG, Gosey L, Milstone AM. Risk factors for peripherally inserted central venous catheter complications in children. JAMA Pediatr. 2013;167(5):429-35. https://doi.org/10.1001/jamapediatrics.2013.775
» https://doi.org/10.1001/jamapediatrics.2013.775 -
42. Nobre KSS, Cardoso MVLML, Rodrigues EC, Melo GM. Progression of peripherally inserted central catheter in hemiclavicular region of newborns. Rev Rene. 2020;21:e42980. https://doi.org/10.15253/2175-6783.20202142980
» https://doi.org/10.15253/2175-6783.20202142980 -
43. Pittiruti M, Celentano D, Barone G, D’Andrea V, Annetta MG, Conti G. A GAVeCeLT bundle for central venous catheterization in neonates and children: A prospective clinical study on 729 cases. J Vasc Access. 2022:11297298221074472. https://doi.org/10.1177/11297298221074472
» https://doi.org/10.1177/11297298221074472 -
44. Gan W, Hu L, Luo Y, Tang M. Impact of peripherally inserted central venous catheter-associated phlebitis in neonate guided by intracavitary electrocardiogram: A systematic review and meta-analysis of randomised controlled trials. Int Wound J. 2022;1-9. https://doi.org/10.1111/iwj.13971
» https://doi.org/10.1111/iwj.13971 -
45. Pet GC, Eickhoff JC, McNevin KE, Do J, McAdams RM. Risk factors for peripherally inserted central catheter complications in neonates. J Perinatol. 2020;40(4):581-8. https://doi.org/10.1038/s41372-019-0575-7
» https://doi.org/10.1038/s41372-019-0575-7 -
46. Erhard DM, Nguyen S, Guy KJ, Casalaz DM, König K. Dwell times and risk of non-elective removal of 1-French peripherally inserted central catheters according to catheter tip position in very preterm infants. Eur J Pediatr. 2017;176(3):407-11. https://doi.org/10.1007/s00431-017-2854-7
» https://doi.org/10.1007/s00431-017-2854-7 -
47. Li X, Guo X, Wan X, Hu Y. Influencing factors of neonatal peripherally inserted central venous catheter (PICC)-related phlebitis: a systematic review, meta-analysis and network meta-analysis. Signa Vitae. 2023;19(2):1-11. https://doi.org/10.22514/sv.2022.019
» https://doi.org/10.22514/sv.2022.019 -
48. Gai M, Wang Y, Chen J, Tang W, Jiang W, Li W, et al. Effect of femoral PICC line insertion in neonates with digestive tract disease. Am J Transl Res [Internet]. 2022 [cited 2023 Apr 28];14(10):7487-93. Available from: https://e-century.us/files/ajtr/14/10/ajtr0144115.pdf
» https://e-century.us/files/ajtr/14/10/ajtr0144115.pdf -
49. Wu Y, Yan J, Tang M, Hu Y, Wan X, Li X, et al. A review of neonatal peripherally inserted central venous catheters in extremely or very low birthweight infants based on a 3-year clinical practice: Complication incidences and risk factors. Front Pediatr. 2022;10:987512. https://doi.org/10.3389/fped.2022.987512
» https://doi.org/10.3389/fped.2022.987512 -
50. Chen IL, Yang MCO, Chen FS, Chung MY, Chen CC, Liu YC, et al. The equations of the inserted length of percutaneous central venous catheters on neonates in NICU. Pediatr Neonatol. 2019;60(3):305-10. https://doi.org/10.1016/j.pedneo.2018.07.011
» https://doi.org/10.1016/j.pedneo.2018.07.011 -
51. Bayoumi MAA, Van Rens MFP, Chandra P, Francia ALV, D’Souza S, George M, et al. Effect of implementing an epicutaneo-caval catheter team in neonatal intensive care unit. J Vasc Access. 2021;22(2):243-53. https://doi.org/10.1177/1129729820928182
» https://doi.org/10.1177/1129729820928182 -
52. Valadão VPC, Reis AT, Araújo BBM, Sá JA Neto, Pacheco STA, Marta CB. Evaluation of thermal blanket use in newborns submitted to the peripherally inserted central venous catheter installation. Nursing [Internet]. 2019 [cited 2023 Jun 26];22(259):3419-25. Available from: https://www.revistanursing.com.br/index.php/revistanursing/article/view/449/423
» https://www.revistanursing.com.br/index.php/revistanursing/article/view/449/423 -
53. Abdeyazdan Z, Sheikhan-Sudani E, Sadeghnia A, Talakoub S. Effect of using static ultrasound technique on peripherally inserted central catheters’ insertion success rate in neonates in a neonatal intensive care unit. Iran J Nurs Midwifery Res [Internet]. 2014 [cited 2021 Aug 2023];19(6):643-6. Available from: https://www.ncbi.nlm.nih.gov/pmc/articles/pmid/25558263/
» https://www.ncbi.nlm.nih.gov/pmc/articles/pmid/25558263/ -
54. Johnson KN, Thomas T, Grove J, Jarboe MD. Insertion of peripherally inserted central catheters in neonates less than 1.5 kg using ultrasound guidance. Pediatr Surg Int. 2016;32(11):1053-7. https://doi.org/10.1007/s00383-016-3959-1
» https://doi.org/10.1007/s00383-016-3959-1 -
55. Doyle SC, Bergin NM, Young R, England A, McEntee MF. Diagnostic accuracy of ultrasound for localizing peripherally inserted central catheter tips in infants in the neonatal intensive care unit: a systematic review and meta-analysis. Pediatr Radiol. 2022;52(12):2421-30. https://doi.org/10.1007/s00247-022-05379-7
» https://doi.org/10.1007/s00247-022-05379-7 -
56. Brescia F, Pittiruti M, Spencer TR, Dawson RB. The SIP protocol update: Eight strategies, incorporating Rapid Peripheral Vein Assessment (RaPeVA), to minimize complications associated with peripherally inserted central catheter insertion. J Vasc Access. 2022;11297298221099838. https://doi.org/10.1177/11297298221099838
» https://doi.org/10.1177/11297298221099838 -
57. Barone G, Pittiruti M, Biasucci DG, Elisei D, Iacobone E, La Greca A, et al. Neo-ECHOTIP: A structured protocol for ultrasound-based tip navigation and tip location during placement of central venous access devices in neonates. J Vasc Access. 2022;23(5):679-88. https://doi.org/10.1177/11297298211007703
» https://doi.org/10.1177/11297298211007703 -
58. Ben Fadel N, Pulgar L, Khurshid F. Point of care ultrasound (POCUS) in Canadian neonatal intensive care units (NICUs): where are we? J Ultrasound. 2019;22(2):201-6. https://doi.org/10.1007/s40477-019-00383-4
» https://doi.org/10.1007/s40477-019-00383-4 -
59. Nakayama Y, Takeshita J, Nakajima Y, Shime N. Ultrasound-guided peripheral vascular catheterization in pediatric patients: a narrative review. Crit Care. 2020;24(1):592. https://doi.org/10.1186/s13054-020-03305-7
» https://doi.org/10.1186/s13054-020-03305-7 -
60. Beleza LO, Ribeiro LM, Vasques CI, Margatho A, Brasil G, Costa K. Updated practical recommendations for the peripherally inserted central catheter in newborns. Rev Enferm UERJ. 2021;29:e61291. https://doi.org/10.12957/reuerj.2021.61291
» https://doi.org/10.12957/reuerj.2021.61291 -
61. Barone G, Pittiruti M. Epicutaneo-caval catheters in neonates: New insights and new suggestions from the recent literature. J Vasc Access. 2020;21(6):805-9. https://doi.org/10.1177/1129729819891546
» https://doi.org/10.1177/1129729819891546 -
62. Pereira HP, Secco IL, Arrué AM, Pontes L, Danski MTR. Implementation of modified Seldinger technology for percutaneous catheterization in critically ill newborns. Rev Esc Enferm USP. 2023;57:e20220347. https://doi.org/10.1590/1980-220X-REEUSP-2022-0347en
» https://doi.org/10.1590/1980-220X-REEUSP-2022-0347en -
63. Cuello-Garcia CA, Santesso N, Morgan RL, Verbeek J, Thayer K, Ansari MT, et al. GRADE guidance 24 optimizing the integration of randomized and non-randomized studies of interventions in evidence syntheses and health guidelines. J Clin Epidemiol. 2022;142:200-8. https://doi.org/10.1016/j.jclinepi.2021.11.026
» https://doi.org/10.1016/j.jclinepi.2021.11.026 -
64. Takashima M, Ray-Barruel G, Ullman A, Keogh S, Rickard CM. Randomized controlled trials in central vascular access devices: a scoping review. PLoS One. 2017;12(3):e0174164. https://doi.org/10.1371/journal.pone.0174164
» https://doi.org/10.1371/journal.pone.0174164
-
*
Paper extracted from doctoral dissertation “Effectiveness of peripherally inserted central catheter insertion techniques in newborns: systematic review and meta-analysis”, presented to Universidade de Brasília, Brasília, DF, Brazil. Supported by Fundação de Apoio à Pesquisa do Distrito Federal (FAPDF), Grant #00193.00001123/2021-44, Brazil.
-
All authors approved the final version of the text.
-
How to cite this articleBeleza LO, Brasil GC, Margatho AS, Vasques CI, Silveira RCCP, Rocha PRS, et al. Prevention of complications related to peripherally inserted central catheter insertion techniques in newborns: systematic review and network meta-analysis. Rev. Latino-Am. Enfermagem. 2024;32:e4161 [cited year month day]. Available from: URL . https://doi.org/10.1590/1518-8345.6905.4161
Edited by
-
Associate Editor:Karina Dal Sasso Mendes
Publication Dates
-
Publication in this collection
05 July 2024 -
Date of issue
2024
History
-
Received
26 June 2023 -
Accepted
06 Jan 2024