Abstract
The objective of this work was to determine the influence of microbial inoculation on degradation efficiency. Three biofilters were used for the treatment of waste gas. A mixture of compost and perlite (8:2) served as the packing material. One biofilter was inoculated with a constructed microbial population. The second remained uninoculated, having the natural population present in the compost. The third biofilter was uninoculated and the packing material was sterilized. The degradation ability of the uninoculated biofilter started to drop after 18 days, while the removal efficiency of inoculated biofilter was stable. The sterile biofilter proved to have no removal efficiency. Moisture content of the packing and ability of the packing to keep moisture was tested. The results showed a significant dependence of the degradation efficiency on the packing moisture content, with highest removal efficiency observed at 70 % moisture content.
Biofiltration; constructed mixed population; moisture content; pollutant mixture
ENGINEERING AND TECHNOLOGY
Impact of biocatalyst and moisture content on toluene/xylene mixture biofiltration
Eva KlapkováI; Martin HaleckýI; Mark FitchII; Carlos Riccardo SoccolIII; Jan PacaI,* * Author for correspondence
IInstitute of Chemical Technology; Department of Fermentation Chemistry and Bioengineering; Technicka 5; Jan.Paca@vscht.cz; 160 28 Prague - Czech Republic
IICivil, Architectural & Environmental Engineering; University of Missouri; Rolla - USA
IIIUniversidade Federal do Paraná; Centro Politécnico; Jardim das Américas, 19011; soccol@engquim.ufpr.br; 81531-970; Curitiba - PR - Brasil
ABSTRACT
The objective of this work was to determine the influence of microbial inoculation on degradation efficiency. Three biofilters were used for the treatment of waste gas. A mixture of compost and perlite (8:2) served as the packing material. One biofilter was inoculated with a constructed microbial population. The second remained uninoculated, having the natural population present in the compost. The third biofilter was uninoculated and the packing material was sterilized. The degradation ability of the uninoculated biofilter started to drop after 18 days, while the removal efficiency of inoculated biofilter was stable. The sterile biofilter proved to have no removal efficiency. Moisture content of the packing and ability of the packing to keep moisture was tested. The results showed a significant dependence of the degradation efficiency on the packing moisture content, with highest removal efficiency observed at 70 % moisture content.
Key words: Biofiltration, constructed mixed population, moisture content, pollutant mixture
INTRODUCTION
Toluene and other monoaromatic compounds such benzene, ethylbenzene and xylenes (BTEX) are commonly found in gasoline-contaminated sites (EPA 1995). The presence of BTEX compounds in the environment is a major concern because of their toxicity (Matteau and Ramsay 1997). Biofiltration systems can effectively remove odours and volatile organic compounds (VOCs) from diluted air streams at a relatively low cost as compared with other alternatives. Biofilters can operate for several years with minimum maintenance. To sustain high removal efficiency, parameters such as water content, nutrient concentration, pH, inlet air relative humidity, and temperature should be controlled (Morales et al., 2003). Biodegradation rates in the biofilm are limited either by microbial activity or contaminant diffusion through the biofilm and thus, in cases where diffusion is not limiting, biofilters with increased microbial activity should have a superior performance.
Moisture content of the biofilter bed is one of the most important parameters of biofiltration process. The optimum moisture of the packing based on compost is reported as between 40 and 60 % (Morales at al., 2003, De Heyder et al., 1994). Bed moisture content of less than 40 % causes a significant drop in the elimination capacity. The drying of the biofilter bed may be caused by low inlet gas humidity (lower than 100 %), changes of inlet gas temperatures and heating of the biofilter bed by exothermic biodegradation processes or the sun or ambient temperature (Morales et al., 2003, Kinney et al., 1999). In contrast to low moisture, too high a moisture content leads to higher bed pressure drop, worse mass transfer (creation of zones with deficiency of oxygen, minerals and carbon and energy sources) and bed compaction (Abumaizar et al., 1998).
MATERIALS AND METHODS
A schematic diagram of the biofilter is shown in Fig. 1. The bioreactor was constructed of glass column 50 cm high with an internal diameter of 50 mm. The packing material was a 8:2 mixture of compost and perlite. The packed bed height was the columns full 50 cm, giving a reactor volume of 9.8.10-4 m3.
The mixed microbial culture used to inoculate the biofilter was comprised of five species, including: Sphingobacterium multivorum (G- rods), Comamonas testosteroni (G- rods), Pseudomonas putida (G- rods), Pseudomonas fluorescens (G- rods) and Chryseobacterium indologenes (G- rods). All the bacterial strains were primary toluene and xylene degraders (i.e. each strain was able to use the individual pollutants as the sole carbon and energy source for growth). The inoculation suspension was prepared using three-stage submerged cultivations with toluene vapor as the sole carbon and energy source. The medium composition for cultivation consisted of (g.L-1): K2HPO4 4.3; KH2PO4 3.4; KNO3 2; MgCl2 . 6 H2O; 0.34; FeSO4 6.10-4; Na2MoO4 1.10-5.
Key biodegradation experimental conditions included: temperature of 22°C, a mineral medium (MM) for growth which contained 0.75 g/L (NH4)2SO4, 0.37 g/L KNO3, 0.1 g/L NaCl, 0.8 g/L K2HPO4, 0.6 g/L KH2PO4, 0.34 g/L MgCl2.6H2O, and 1 mL/L trace elements. Sterile MM was added once per week.
The synthetic waste gas influent included toluene and xylene (technical grade). The VOCs in the gas phase were measured using an Agilent 6890 N gas chromatograph equipped with an ultra alloy-5 (5 % phenylmethylsilicone) capillary column 30 m in length, 0.53 mm inner, and with a 1.5 µm film thickness (Quadrex Corp., UA5 - 30V - 1.5 F, New Haven, CT). The carrier gas used was ultra high purity argon at a flow rate of 5 ml.min-1. Detection was accomplished with a flame ionization detector (FID) with ultra high purity hydrogen and breathing quality air at flow rates of 28 ml.min-1 and 315 ml.min-1, respectively. GC operating conditions were: column temperature, 80 °C; FID temperature, 250 °C.
In this study, the following terms for performance calculations are defined as:
Elimination capacity
Organic load
Removal efficiency
Evolution rate of CO2
Cin, Cout - inlet and outlet pollutant or CO2 concentration (gC.m-3), Q - air flow rate (m3.h-1), Vb - filter bed volume (m3).
Experiments were carried out with sterile air flow using input and output air filters (glass wool, filament diameter 0.015 mm). The biofilters were loaded with a constant inlet concentration of 500 ± 50 mg.m-3 of both toluene and xylene (1:1 ratio). The air flow rate was kept constant at 0.5 L.min-1, giving a total organic loading of 30 gc m-3 h-1.
RESULTS AND DISCUSSION
One biofilter was inoculated with the previously defined microbial culture; this biofilter was not sterilized prior to inoculation. The second one used only the natural microflora present in the compost packing medium. The third biofilter was sterilized.
Fig. 2a shows the removal efficiencies of all the biofilters. The sterile biofilter was not able to eliminate any toluene or xylene. RE during the first three days was caused just due to adsorption by the packing material. After that the RE decreased to zero.
The inoculated biofilter was able after three days to eliminate about 90 % of the organic load. The removal efficiency remained fairly stable at about 85 % during the whole time of experiment. The second biofilter, with the natural microflora, showed a similar performance during the first thirty days of the experiment. Thereafter the RE decreased. Clearly the biocatalyst is a key parameter of the process. The inoculum prepared using toluene as the sole source of carbon and energy was able to metabolize organic loading for a longer period as compared to the natural microflora in the compost/perlite material. The induction of enzymes participating in metabolic pathways of aromatic hydrocarbons degradation is one of the major parameters of a successful biodegradation process.
The decrease in RE is similar to that reported in other biofiltration studies (Devinny et al., 1999), which has been attributed to plugging of pore spaces (Marek et al., 1999).
The CO2 production during aromatics degradation is shown in Fig. 2b. The quantity of CO2 produced (as carbon) in some cases slightly exceeded the quantity of contaminant consumed (EC), given the carbon loading was 27.8 gc m-3 h-1. Excess CO2 evolution may be due to endogenous decay of biomass. For steady-state degradation, a 100% mass balance of inlet and outlet carbon is expected. If not at steady state, the contaminant consumed is partly used as the carbon sources for microbial growth, which explains deficits in CO2 production. A second sink for carbon can be that as biodegradation takes place, the CO2 produced may accumulate in the biofilm as one of the carbonate species, HCO3-, H2CO3 or CO32- (Jorio et al., 2000, Jorio et al., 1998). The population naturally presented in compost used more carbon, probably for microbial growth, than the artificial prepared microbial population adapted for toluene. The effect of moisture content in the biofilter was tested. Contaminated air was humidified by bubbling through water before entering the biofilter but no water or mineral medium was added into biofilter. Two different air flow rates were used, 1 L.min-1 and 0.5 L.min-1. The higher air flow rate resulted in a more significant decrease of both the degradation efficiency (Fig. 4) and the packing moisture content (Fig. 3). The highest moisture content (about 70 %) gave the highest removal efficiency in the both air flow rates (Fig. 4). It should be noted that the effect of changes in time (biofilm aging) and removal efficiency cannot be separated. However, a very similar influence of the packing moisture content on removal efficiency was reported by Morales et al., 2003. They observed rapid decrease of degradation efficiency when packing moisture content dropped below 60 %.
CONCLUSIONS
No difference of the removal rate has been detected during the acclimation (first two weeks) for biofilters inoculated with the enrichment culture and that containing a natural compost microflora only. The microbial population prepared by cultivation with toluene as the sole source of carbon and energy had significant effcet on the long-term degradation of toluene and xylene. The induction of key enzymes is necessary for successful pollutant removal, and in this case the adapted inoculum performed better at longer term than the natural organisms present in the packing. The volumetric air flow rate in a biofilter also effects drying-out of the packing. A moisture content of about 70 % was found to be optimal for effective process and plays an important role in reaching high values of removal efficiency.
ACKNOWLEDGEMENTS
The work was financially supported by the Czech Science Foundation, Join Project 104/05/0194 and by the Ministry of Education of the Czech Rep., Project MSM 6046137305.
Received: September 14, 2005;
Revised: June 06, 2005;
Accepted: August 30, 2006.
- Abumaizar, R. J.; Kocher, W. and Smith, E. H. (1998), Biofiltration of BTEX Contaminated Air Streams Using Compost-Activated Carbon Filter Media. Journal of Hazardous Materials, 60, 111-126.
- Aizpuru, A.; Malhautier L.; Roux J. C. and Fanlo J. L. (2003), Biofiltration of a Mixture of Volatile Organic Compounds on Granular Activated Carbon. Biotechnology and Bioengineering, 83, 479-488.
- De Heyder, B.; Overmeire, A.; Van Langenhove, H. and Verstraete, W. (1994), Ethene Removal from a Synthetic Waste Gas Using a Dry Biobed. Biotechnology and Bioengineering, 44, 642-648.
- Devinny J. S.; Deshusses M. A. and Webster T. S. (1999), Biofiltration for Air Pollution Control Boca Raton: Lewis Publ. pp. 255-258.
- Jorio H.; Bibeau L. and Heitz M. (2000), Effects of Gas Flow Rate and Inlet Concentrations on Xylene Vapors Biofiltration Performance. Chemical Engineering Journal, 76, 209-221.
- Jorio H.; Kiared K.; Brzezinski R.; Leroux A.; Viel G. and Heitz M. (1998), Treatment of Air Polluted with High Concentration of Toluene and Xylene in a Pilot-Scale Biofilter. J. Chem. Biotechnol, 73, 183-196.
- Kinney, K. A.; Loehr, R. C. and Cosi, R. L. (1999), Vapor-Phase Bioreactors: Avoiding Problems Through Better Design and Operation. Environmental Progress, 18, 222-230.
- Marek J.; Páca J.; Koutský B. and Gerrard A. M. (1999), Determination of Local Elimination Capacities and Moisture Contents in Different Biofilters Treating Toluene and Xylene. Biodegradation, 10, 307-313.
- Matteau Y. and Ramsay B. (1997), Active Compost Biofiltration of Toluene. Biodegradation, 8, 135-141.
- Morales, M.; Hernández, S.; Cornabé, T.; Revah, S. and Auria, R. (2003), Effect of Drying on Biofilter Performance: Modeling and Experimental Approach. Environmental Sciency and Technology, 37, 985-992.
Publication Dates
-
Publication in this collection
26 Feb 2007 -
Date of issue
Nov 2006
History
-
Received
14 Sept 2005 -
Reviewed
06 June 2005 -
Accepted
30 Aug 2006