Effect of cleanser solutions on the color of acrylic resins associated with titanium and nickel-chromium alloys

Abstract

This study evaluated the effect of cleanser solutions on the color of heat-polymerized acrylic resin (HPAR) and on the brightness of dental alloys with 180 immersion trials. Disk-shaped specimens were made with I) commercially pure titanium, II) nickel-chromium-molybdenum-titanium, III) nickel-chromium molybdenum, and IV) nickel-chromium-molybdenum beryllium. Each cast disk was invested in the flasks, incorporating the metal disk into the HPAR. The specimens (n = 5) were then immersed in solutions containing: 0.05% sodium hypochlorite, 0.12% chlorhexidine digluconate, 0.500 mg cetylpyridinium chloride, a citric acid tablet, one of two different sodium perborate/enzyme tablets, and water. The color measurements (∆E) of the HPAR were determined by a colorimeter in accordance with the National Bureau of Standards. The surface brightness of the metal was visually examined for the presence of tarnish. The results (ANOVA; Tukey test-α = 0.05) show that there was a significant difference between the groups (p < 0.001) but not among the solutions (p = 0.273). The highest mean was obtained for group III (5.06), followed by group II (2.14). The lowest averages were obtained for groups I (1.33) and IV (1.35). The color changes in groups I, II and IV were slight but noticeable, and the color change was considerable for group III. The visual analysis showed that 0.05% sodium hypochlorite caused metallic brightness changes in groups II and IV. It can be concluded that the agents had the same effect on the color of the resin and that the metallic alloys are not resistant to the action of 0.05% sodium hypochlorite.

Denture Cleansers; Titanium; Chromium Alloys; Acrylic Resins; Color


Introduction

Removable dentures can be cleaned using chemical, mechanical or combined methods.11 Souza RF, Paranhos HFO, Silva CHL, Abu-Naba’a L, Fedorowicz Z, Gurgan CA. Interventions for cleaning dentures in adults. Cochrane Database Syst Rev. 2009 Oct;7(4):CD007395. Chemical methods mainly include soaking the dentures in a household or commercial solution. Alkaline peroxides, sodium hypochlorite and mouthwashes are agents that are frequently included in these solutions.22 Nikawa H, Hamada T, Yamashiro H, Kumagai H. A review of in vitro and in vivo methods to evaluate the efficacy of denture cleansers. Int J Prosthodont. 1999 Mar-Apr;12(2):153-9. Alkaline hypochlorites are bactericidal and fungicidal agents, as well as stain bleaching33 Jagger DC, Al-Akhazam L, Harrison A, Rees JS. The effectiveness of seven denture cleansers on tea stain removal from PMMA acrylic resin. Int J Prosthodont. 2002 Nov-Dec;15(6):549-52. agents, and they have been indicated for prosthetic disinfection and for overnight soaking.44 Felton D, Cooper L, Duqum I, Minsley G, Guckes A, Haug S, et al. Evidence-based guidelines for the care and maintenance of complete dentures: a publication of the American College of Prosthodontists. J Prosthodont. 2011 Feb;20 Suppl 1:S1-S12. Alkaline peroxides work through an oxygen-liberating process that enables mechanical cleaning via the release of oxygen bubbles, as well as chemical cleaning, and they have been widely used for prosthesis cleaning.55 Shay K. Denture hygiene: a review and update. J Contemp Dent Pract. 2000 Feb 15;1(2):28-41. Mouthwashes are very popular, mainly due to their pleasant fragrance and fresh taste, and they have demonstrated the ability to inhibit the microbial colonization of prosthetic surfaces.66 Andre RF, Andrade IM, Silva-Lovato CH, Paranhos HFO, Pimenta FC, Ito IY. Prevalence of mutans streptococci isolated from complete dentures and their susceptibility to mouthrinses. Braz Dent J. 2011;22(1):62-7. Regardless of the efficacy of such cleansers, a factor that should be taken into consideration is the presence of adverse effects on the components of the prosthetic device. The color stability of acrylic resins is of particular concern, as it is associated with the esthetic reproduction of oral mucosa. Discoloration may be caused by several factors; cleaning solutions77 Paranhos HFO, Peracini A, Pisani MX, Oliveira VC, Souza RF, Silva-Lovato CH. Color stability, surface roughness and flexural strength of an acrylic resin submitted to simulated overnight immersion in denture cleansers. Braz Dent J. 2013;24(2):152-6. and hygiene habits33 Jagger DC, Al-Akhazam L, Harrison A, Rees JS. The effectiveness of seven denture cleansers on tea stain removal from PMMA acrylic resin. Int J Prosthodont. 2002 Nov-Dec;15(6):549-52. are extrinsic factors that must be considered. Patients often do not receive instructions about effective hygiene, and they may over-clean the prosthesis using home-care products, which can have harmful effects.88 Denture cleansers. Council on Dental Materials, Instruments, and Equipment. J Am Dent Assoc. 1983 Jan;106(1):77-9.

Metal alloys may corrode or be stained as a result of surface contact with the chlorine or oxygen that are present in some commercial cleansers.99 Garcia RCMR, Souza Júnior JA, Rached RN, Del Bel Cury AA. Effect of denture cleansers on the surface roughness and hardness of a microwave-cured acrylic resin and dental alloys. J Prosthodont. 2004 Sep;13(3):173-8. Nickel-chromium alloys may be an appropriate substitute for gold alloys because they are low cost, have a lower specific weight and have better physical properties, such as mechanical resistance, hardness, and corrosion resistance.1010 Morris HF, Manz M, Stoffer W, Weir D. Casting alloys: the materials and “The Clinical Effects”. Adv Dent Res. 1992 Sep;6:28-31. Titanium alloys have several advantages, including biocompatibility, corrosion resistance, a low specific weight, a low elastic modulus, low thermal conductivity, and high mechanical resistance,1111 Mori T, Togaya T, Jean-Louis M, Yabugami M. Titanium for removable dentures. I. Laboratory procedures. J Oral Rehabil. 1997 May;24(5):338-41. and they are well accepted by patients. However, there have been reports of titanium alloy tarnishing (surface discoloration)1212 Sutton AJ, Rogers PM. Discoloration of a titanium alloy removable partial denture: a clinical report. J Prosthodont. 2001 Jun;10(2):102-4. and corrosion (surface pitting).1313 Zavanelli RA, Henriques GEP, Ferreira I, Rollo JMDA. Corrosion-fatigue life of commercially pure titanium and Ti-6Al-4V alloys in different storage environments. J Prosthet Dent. 2000 Sep;84(3):274-9.

Previous studies have evaluated color alterations in acrylic resins treated with 0.5% and 1% hypochlorite alkaline solutions,77 Paranhos HFO, Peracini A, Pisani MX, Oliveira VC, Souza RF, Silva-Lovato CH. Color stability, surface roughness and flexural strength of an acrylic resin submitted to simulated overnight immersion in denture cleansers. Braz Dent J. 2013;24(2):152-6.,1414 Paranhos HFO, Davi LR, Peracini A, Soares RB, Lovato CHS, Souza RF. Comparison of physical and mechanical properties of microwave-polymerized acrylic resin after disinfection in sodium hypochlorite solutions. Braz Dent J. 2009;20(4):331-5.,1515 Davi LR, Peracini A, Ribeiro NQ, Soares RB, Silva CH, Paranhos HF, et al. Effect of the physical properties of acrylic resin of overnight immersion in sodium hypochlorite solution. Gerodontology. 2010 Dec;27(4):297-302.,1616 Hong G, Murata H, Li Y, Sadamori S, Hamada T. Influence of denture cleansers on the color stability of three types of denture base acrylic resin. J Prosthet Dent. 2009 Mar;101(3):205-13. as well as with alkaline peroxide solutions,77 Paranhos HFO, Peracini A, Pisani MX, Oliveira VC, Souza RF, Silva-Lovato CH. Color stability, surface roughness and flexural strength of an acrylic resin submitted to simulated overnight immersion in denture cleansers. Braz Dent J. 2013;24(2):152-6.,1717 Unlu A, Altay OT, Sahmali S. The role of denture cleansers on the whitening of acrylic resins. Int J Prosthodont. 1996 May-Jun;9(3):266-70.,1818 Peracini A, Davi LR, Ribeiro NQ, Souza RF, Lovato-Silva CH, Paranhos HFO. Effect of denture cleansers on physical properties of heat-polymerized acrylic resin. J Prosthodont Res. 2010 Apr;54(2):78-83. and they have revealed that the type of sanitizer, the immersion time, and the period of use are factors to be considered. In relation to the metal surface, it was determined that tarnish and spot corrosion on Co-Cr alloys are deleterious effects of immersion in cleansing solutions. However, commercially pure titanium was not evaluated.1919 Felipucci DNB, Davi LR, Paranhos HFO, Bezzon OL, Silva RF, Barbosa Júnior F, et al. Effect of different cleansers on the weight and ion release of removable partial denture: an in vitro study. J Appl Oral Sci. 2011 Oct;19(5):483-7.

The purpose of this study was to evaluate the effects of six cleansing solutions on the color stability of heat-polymerized acrylic resin and on the surface brightness of four dental alloys. The null hypothesis tested was that immersion in disinfection solutions would not influence the color stability of the acrylic resin or the surface brightness of the dental alloys.

Methodology

Disk-shaped (12 x 3 mm) wax patterns (GEO, Renfert GmbH, Hilzingen, Germany) were used as a sprue to cast disks of each of the following alloys: I) Commercially pure titanium (Tritan, Dentaurum Inc., Pforzheim, Germany), II) Ni-Cr-Mo-Ti (Vi-Star, Talladium do Brasil, Curitiba, Brazil), III) Ni-Cr Mo (Fit Cast-SB Plus, Talladium do Brasil) and IV) Ni-Cr-Mo-Be (Fit Cast-V, Talladium do Brasil).

After casting, the metal disks were polished with 180-grit sandpaper (Norton Abrasives, Saint-Gobain, France) in a polishing machine (Arotec, Cotia, Brazil). Metallic flasks were previously prepared with Teflon rectangular matrices (38 x 18 x 4 mm) and then invested with type IV dental stone (Durone Dentsply, Petrópolis, Brazil). The Teflon matrices were removed, and the cast disks were inserted in the flasks in the left side of each rectangular mold. Before packing the heat-polymerized acrylic resin (Lucitone 550, Dentsply), the mold was isolated with a separating medium (Cel-Lac, SS White, Rio de Janeiro, Brazil).

The resin was manipulated, packed, and pressed into the mold according to the manufacturer’s instructions. The curing cycle was carried out in water at 73 °C for 90 min and at 94 °C for 30 minutes. The specimens were immersed in distilled water at 37 ± 1 °C for 50 ± 2 hours to eliminate any residual monomer. The excess resin was trimmed, and one of the surfaces was finished using 180, 220, 400, 600 and 1200-grit sandpapers (Norton, Saint-Gobain, Vinhedo, Brazil) in a polishing machine and then using polishing cloths and a 1-µm diamond suspension (Fortel Ind. e Com., São Paulo, Brazil). Thirty-five specimens of each metal were prepared.

The specimens (n = 5; power level = 0.94) were randomly distributed into groups and immersed in the following solutions for the indicated length of time: 1) 0.05% sodium hypochlorite (Q’Boa; Anhembi S/A, Osasco, Brazil) - 10 minutes; 2) 0.12% chlorhexidine digluconate (Periogard, Colgate-Palmolive Ind., Osasco, Brazil) - 10 minutes; 3) cetylpyridinium chloride, 0.500 mg (Cepacol, Sanofi-Aventis Farmacêutica Ltda., Suzano, Brazil) - 10 minutes; 4) Corega Tabs (sodium perborate and enzyme, Stafford-Miller Ind., Rio de Janeiro, Brazil) - 5 minutes; 5) Medical Interporous (citric acid, MSI-Laboratories AG, Vaduz, Liechtenstein) - 15 minutes; and 6) Polident 3 Minute (sodium perborate and enzyme, GlaxoSmithKline, Philadelphia, USA) - 3 minutes. The control group was immersed in 200 mL of deionized water for 15 minutes. The 0.05% sodium hypochlorite solution was prepared by mixing 200 mL of deionized water (23 ± 2 ºC) and 6 mL of Q’Boa (2% sodium hypochlorite). The samples used in the Periogard and Cepacol tests were immersed in 50 mL of the solution. The effervescents were prepared by adding one tablet to 200 mL of warm deionized water (30 ± 2 ºC). All of the experiments consisted of 180 consecutive hygiene immersion trials, so the immersion time was multiplied by 180. This corresponded to 9 hours for Polident, 15 hours for Corega, 30 hours for sodium hypochlorite, Cepacol and Periogard, and 45 hours for Medical Interporous and deionized water. The solutions were changed six times for all of the products.

The color measurements were determined by a colorimeter (Color-guide, BYK-Gardner, Geretsried, Germany) with a standardized lighting D65, an observation angle of 10°, and a light source within the visible spectrum (400 to 700 nm). A heavy silicone mold was used to standardize the position of the specimens for the color measurements. The measurement geometry was 45°, and the area was 11 mm in diameter. The CIELab color system was used, and the total color alteration (ΔE) was calculated using the following equation: ∆E*=[(∆L*)2+(∆a*)2+(∆b*)2]½. To relate the ∆E to the clinical environment, the data were quantified according to National Bureau of Standards units20 using the following formula: NBS units = ∆E 0.92; they were then classified according to: 1) Insignificant, 0.0-0.5; 2) Slight, 0.5-1.5; 3) Noticeable, 1.5-3.0; 4) Considerable, 3.0-6.0; 5) Very, 6.0-12.0; 6) Excessive, > 12.0.

The metallic brightness was measured visually by a single calibrated examiner and classified by the presence or absence of tarnish on the metal surface. One control specimen (without immersion) was employed for comparative analysis.

The ΔE values were submitted to two-way analysis of variance (ANOVA) followed by a Tukey test for pair-wise comparisons (α = 0.05) using the SPSS 17.0 program (SPSS Inc., Chicago, USA).

Results

The color changes were recorded as the difference between the average of three measurements in each period of time (T0 and T1). Figure 1 shows the mean ∆E values. ANOVA showed that there was a difference among the groups (p < 0.001), but not among the solutions (p = 0.273) or among the interactions (p = 0.168). Table 1 shows the results of the Tukey test.

Figure 1.
Mean ∆E values after immersion in the solutions.

Table 1.
Mean and standard deviation of color change (ΔE).

The highest mean was obtained for group III (Fit Cast-SB Plus®), followed by group II (Vi-Star®). The lowest averages were obtained for groups I (Tritan®) and IV (Fit Cast-V®), which did not differ from each other. Table 2 shows the results in NBS units.

Table 2.
Mean and standard deviation of color change in NBS units.

The changes in groups I, II and IV were classified as “slight” (< 1.5) and “noticeable” (< 3.0), except for Polident in group II. However, for group III, the changes were classified as “considerable” (3.0 < x < 6.0). The visual analysis showed that the sodium hypochlorite caused metallic brightness changes, with dark tarnish on the metal surface in groups II and IV (Figures 2 and 3). Groups I and III did not show any tarnishing. The other solutions did not cause any surface changes on the alloys.

Figure 2.
Images of the Vi-Star group (A) before and (B) after immersion in a 0.05% sodium hypochlorite solution.

Figure 3.
Images of the Fit-Cast V group (A) before and (B) after immersion in a 0.05% sodium hypochlorite solution.

Discussion

Daily hygiene for a removable prosthesis should include brushing and immersion in solutions for biofilm control2121 Paranhos HFO, Salles AES, Macedo LD, Silva-Lovato CH, Pagnano VO, Watanabe E. Complete denture biofilm after brushing with specific denture paste, neutral soap and artificial saliva. Braz Dent J. 2013;24(1):47-52. and the reduction of microorganisms, as well as to avoid the signs of denture stomatitis.2222 Barnabe W, Mendonca Neto T, Pimenta FC, Pegoraro LF, Scolaro JM. Efficacy of sodium hypochlorite and coconut soap used as disinfecting agents in the reduction of denture stomatitis, Streptococcus mutans and Candida albicans. J Oral Rehabil. 2004 May;31(5):453-9. The materials involved in making removable partial dentures are acrylic resins and metallic alloys, which makes it difficult to institute a safe hygiene protocol. The effects of cleansers have not been widely evaluated on RPD metallic components.11 Souza RF, Paranhos HFO, Silva CHL, Abu-Naba’a L, Fedorowicz Z, Gurgan CA. Interventions for cleaning dentures in adults. Cochrane Database Syst Rev. 2009 Oct;7(4):CD007395.

Commercial bleaches are often indicated as cleansers because they are inexpensive and easy to use.44 Felton D, Cooper L, Duqum I, Minsley G, Guckes A, Haug S, et al. Evidence-based guidelines for the care and maintenance of complete dentures: a publication of the American College of Prosthodontists. J Prosthodont. 2011 Feb;20 Suppl 1:S1-S12.,2323 Keyf F, Gungor T. Comparison of effects of bleach and cleansing tablet on reflectance and surface changes of a dental alloy used for removable partial dentures. J Biomater Appl. 2003 Jul;18(1):5-14. Hence, 0.05% sodium hypochlorite was employed due to its antimicrobial properties.2222 Barnabe W, Mendonca Neto T, Pimenta FC, Pegoraro LF, Scolaro JM. Efficacy of sodium hypochlorite and coconut soap used as disinfecting agents in the reduction of denture stomatitis, Streptococcus mutans and Candida albicans. J Oral Rehabil. 2004 May;31(5):453-9. The tablets and mouthwashes were included for the comparison of the methods usually employed and studied55 Shay K. Denture hygiene: a review and update. J Contemp Dent Pract. 2000 Feb 15;1(2):28-41. and due to their antimicrobial effects.66 Andre RF, Andrade IM, Silva-Lovato CH, Paranhos HFO, Pimenta FC, Ito IY. Prevalence of mutans streptococci isolated from complete dentures and their susceptibility to mouthrinses. Braz Dent J. 2011;22(1):62-7.,2424 Andrade IM, Cruz PC, Silva-Lovato CH, Souza RF, Souza-Gugelmin MCM, Paranhos HFO. Effect of chlorhexidine on denture biofilm accumulation. J Prosthodont. 2012 Jan;21(1):2-6. Water was used as a control because it is indicated for overnight immersion,55 Shay K. Denture hygiene: a review and update. J Contemp Dent Pract. 2000 Feb 15;1(2):28-41. and it prevents the release of ions.2525 Felipucci DNB, Davi LR, Paranhos HFO, Bezzon OL, Silva RF, Pagnano VO. Effect of different cleansers on the surface of removable partial denture. Braz Dent J. 2011;22(5):392-7.,2626 Davi LR, Felipucci DNB, Souza RF, Bezzon OL, Lovato-Silva CH, Pagnano VO, et al. Effect of denture cleansers on metal Ion release and surface roughness of denture base materials. Braz Dent J. 2012;23(4):387-93.

Among the properties of the acrylic resin, color stability is considered to be the most decisive in both the longevity of the prosthesis and in patient satisfaction.1616 Hong G, Murata H, Li Y, Sadamori S, Hamada T. Influence of denture cleansers on the color stability of three types of denture base acrylic resin. J Prosthet Dent. 2009 Mar;101(3):205-13. The measurements were performed with a colorimeter using an objective, and quantitative readings were analyzed and correlated to NBS units for comparing the color and quality control functions. The ΔE values were considered equal to a visually detectable difference in 50% of cases, and a ΔE greater than 2 was detected 100% of the time.2020 Polyzois GL, Yannikakis SA, Zissis AJ, Demetriou PP. Color changes of denture base materials after disinfection and sterilization immersion. Int J Prosthodont. 1997 Jan-Feb;10(1):83-9.

The study results suggest that the null hypothesis should be rejected because the disinfection solutions influenced the color stability of the acrylic resin and the surface brightness of the dental alloys. However, there were no differences among the solutions. Paranhos et al.1414 Paranhos HFO, Davi LR, Peracini A, Soares RB, Lovato CHS, Souza RF. Comparison of physical and mechanical properties of microwave-polymerized acrylic resin after disinfection in sodium hypochlorite solutions. Braz Dent J. 2009;20(4):331-5. performed 20-minute immersions in sodium hypochlorite (0.5% and 1%) for 180 days and found no color changes for resins; however, in the same period with immersions of 8 hours, a 1% solution caused “slight” changes in NBS units.2626 Davi LR, Felipucci DNB, Souza RF, Bezzon OL, Lovato-Silva CH, Pagnano VO, et al. Effect of denture cleansers on metal Ion release and surface roughness of denture base materials. Braz Dent J. 2012;23(4):387-93. Similarly, Hong et al.1616 Hong G, Murata H, Li Y, Sadamori S, Hamada T. Influence of denture cleansers on the color stability of three types of denture base acrylic resin. J Prosthet Dent. 2009 Mar;101(3):205-13. found changes with 8-hour immersions in a 0.5% solution, indicating a trend of increasing ΔΕ values with time. Therefore, the use of sodium hypochlorite as an everyday cleanser would require a study using lower concentrations over longer periods.77 Paranhos HFO, Peracini A, Pisani MX, Oliveira VC, Souza RF, Silva-Lovato CH. Color stability, surface roughness and flexural strength of an acrylic resin submitted to simulated overnight immersion in denture cleansers. Braz Dent J. 2013;24(2):152-6. No studies have evaluated the color alterations with a 0.05% concentration.

The results revealed that the effects were the same as those of the other solutions. There is controversy about tablets, specifically regarding whether they cause damage to the resin and the metallic components of the prosthetic device. The water temperature,2727 Robinson JG, Mccabe JF, Storer R. Denture bases: the effects of various treatments on clarity, strength and structure. J Dent. 1987 Aug;15(4):159-65. immersion time2626 Davi LR, Felipucci DNB, Souza RF, Bezzon OL, Lovato-Silva CH, Pagnano VO, et al. Effect of denture cleansers on metal Ion release and surface roughness of denture base materials. Braz Dent J. 2012;23(4):387-93. and the composition of the product88 Denture cleansers. Council on Dental Materials, Instruments, and Equipment. J Am Dent Assoc. 1983 Jan;106(1):77-9. are critical factors. Studies have found that for acrylic resins, Corega Tabs have a greater whitening effect than Polident,1717 Unlu A, Altay OT, Sahmali S. The role of denture cleansers on the whitening of acrylic resins. Int J Prosthodont. 1996 May-Jun;9(3):266-70. Bony Plus1818 Peracini A, Davi LR, Ribeiro NQ, Souza RF, Lovato-Silva CH, Paranhos HFO. Effect of denture cleansers on physical properties of heat-polymerized acrylic resin. J Prosthodont Res. 2010 Apr;54(2):78-83. and a 0.5% hypochlorite solution.77 Paranhos HFO, Peracini A, Pisani MX, Oliveira VC, Souza RF, Silva-Lovato CH. Color stability, surface roughness and flexural strength of an acrylic resin submitted to simulated overnight immersion in denture cleansers. Braz Dent J. 2013;24(2):152-6. Corega contains agents that release oxygen with enzymes, supporting the hypothesis that oxidation in combination with a strong alkaline solution can be deleterious.77 Paranhos HFO, Peracini A, Pisani MX, Oliveira VC, Souza RF, Silva-Lovato CH. Color stability, surface roughness and flexural strength of an acrylic resin submitted to simulated overnight immersion in denture cleansers. Braz Dent J. 2013;24(2):152-6.,1717 Unlu A, Altay OT, Sahmali S. The role of denture cleansers on the whitening of acrylic resins. Int J Prosthodont. 1996 May-Jun;9(3):266-70. In relation to the metallic components, weight loss and ion release,1919 Felipucci DNB, Davi LR, Paranhos HFO, Bezzon OL, Silva RF, Barbosa Júnior F, et al. Effect of different cleansers on the weight and ion release of removable partial denture: an in vitro study. J Appl Oral Sci. 2011 Oct;19(5):483-7. as well as tarnishing and spot corrosion,2525 Felipucci DNB, Davi LR, Paranhos HFO, Bezzon OL, Silva RF, Pagnano VO. Effect of different cleansers on the surface of removable partial denture. Braz Dent J. 2011;22(5):392-7. were observed in Co-Cr alloys after immersion in a citric acid product (Medical Interporous). With regard to titanium, Davi et al.2626 Davi LR, Felipucci DNB, Souza RF, Bezzon OL, Lovato-Silva CH, Pagnano VO, et al. Effect of denture cleansers on metal Ion release and surface roughness of denture base materials. Braz Dent J. 2012;23(4):387-93. did not find alterations in surface roughness, but the color was not evaluated. Although mouthwashes can have adverse effects on resins (that is, stains on denture bases and teeth),22 Nikawa H, Hamada T, Yamashiro H, Kumagai H. A review of in vitro and in vivo methods to evaluate the efficacy of denture cleansers. Int J Prosthodont. 1999 Mar-Apr;12(2):153-9. the results are not different from those of the other solutions.

Despite the use of the same resin and despite having followed the manufacturers’ instructions, there were differences among the groups. The Fit Cast-SB Plus specimens showed changes classified as “considerable”. The resin associated with titanium (Tritan) and Ni-Cr-Mo-Be (Fit Cast-V) showed the least color change. The manipulation difficulties, storage time, water temperature and the limitations of in vitro studies may explain these differences. The manipulation followed the manufacturer’s instructions, and the polymerizing cycle was standardized. However, the inclusion of oils or moisture could be considered because oil from the operator’s hands might cause local deterioration within the mass of resin, resulting in a whitening effect.2727 Robinson JG, Mccabe JF, Storer R. Denture bases: the effects of various treatments on clarity, strength and structure. J Dent. 1987 Aug;15(4):159-65. In addition, the use of short or low-temperature heat-polymerizing cycles could result in an elevated level of residual monomer that could react with the solvents and external reagents,1717 Unlu A, Altay OT, Sahmali S. The role of denture cleansers on the whitening of acrylic resins. Int J Prosthodont. 1996 May-Jun;9(3):266-70.,2727 Robinson JG, Mccabe JF, Storer R. Denture bases: the effects of various treatments on clarity, strength and structure. J Dent. 1987 Aug;15(4):159-65. promoting resin color change. The high temperature of the water used with the tablets could cause bleaching of the resin because the boiling water may disorganize the resin matrix and allow higher water adsorption, which acts as a plasticizer on the acrylic and promotes the bleaching effect.2828 Arab J, Newton JP, Lloyd CH. The importance of water temperature in denture cleaning procedures. J Dent. 1988 Dec;16(6):277-81. The immersions were performed for the same amount of time and with the same water temperature, eliminating the possibility of color change due to high temperatures. Thus, the results should be due to the different chemical compositions of the tested alloys.

The visual analysis showed that the hypochlorite caused metallic brightness changes, with dark tarnish on the metal surface in groups II and IV. Corrosion is an electrochemical process of ion release and is dependent on the alloy composition, surface conditions, pH and environmental mechanical factors. Chemical compounds known as ‘corrosion products’ are produced when the metal comes in contact with non-metal elements.2929 Schmalz G, Garhammer P. Biological interactions of dental cast alloys with oral tissues. Dent Mater. 2002 Jul;18(5):396-406. By means of passivation, that is, by the formation of a protective pellicle on the metal surface, there is an inhibition of the corrosion process, which is very common on titanium surfaces. This also occurs in nickel-chromium alloys without beryllium, whose passivating pellicle is composed of chromium oxide, which is transparent and strongly adheres to the surface. In this study, commercially pure titanium did not show any metallic brightness change. However, although Vi-Star alloy containing titanium was used, it was not sufficient to prevent tarnish on the metallic surface.

When using sodium hypochlorite, there is a dissociation of chloride ions, which are extremely reactive. Surface changes and staining were also observed in previous studies,1212 Sutton AJ, Rogers PM. Discoloration of a titanium alloy removable partial denture: a clinical report. J Prosthodont. 2001 Jun;10(2):102-4.,3030 Backenstose WM, Wells JG. Side effects of immersion-type cleansers on the metal components of dentures. J Prosthet Dent. 1977 Jun;37(6):615-21. which reported severe oxidation of metals immersed in sodium hypochlorite solution. Keyf and Güngör2323 Keyf F, Gungor T. Comparison of effects of bleach and cleansing tablet on reflectance and surface changes of a dental alloy used for removable partial dentures. J Biomater Appl. 2003 Jul;18(1):5-14. reported that not only hypochlorite but also peroxide solutions caused both discoloration (loss of gloss) and staining on the surface of a Co-Cr alloy. These findings are not in accord with our results because the tablets and mouthwashes did not cause any surface changes on the alloys. This finding may be explained by differences in the evaluation methods employed, i.e., visual vs. spectrophotometric. Felipucci et al.2525 Felipucci DNB, Davi LR, Paranhos HFO, Bezzon OL, Silva RF, Pagnano VO. Effect of different cleansers on the surface of removable partial denture. Braz Dent J. 2011;22(5):392-7. reported that the use of 0.05% sodium hypochlorite and citric acid-based tablets caused harmful effects to the metallic components of a Co-Cr alloy, including tarnishing and spot corrosion.

With regard to the methodological limitations of this study, only one property of the acrylic resin was evaluated, with one immersion time (short immersion) and a 6-month simulated period. The lack of objective and SEM analyses of the metallic brightness must also be considered.

Future studies should address the use of different immersion times and longer periods of use and focus on other properties that are also relevant to removable partial denture components, such as flexural strength and surface roughness. Moreover, the use of optical microscopy and SEM as well as EDS can detect small color changes and the chemical elements present on metallic surfaces.

Conclusion

It can be concluded that all the cleansing agents had the same effect on the color of the acrylic resin and that the greatest color change occurred for the Fit Cast-SB® group. The alloys were resistant to the action of the cleansing agents except for the 0.05% sodium hypochlorite, which caused alteration of the metal surface, especially of the Ni-Cr alloys.

References

  • 1
    Souza RF, Paranhos HFO, Silva CHL, Abu-Naba’a L, Fedorowicz Z, Gurgan CA. Interventions for cleaning dentures in adults. Cochrane Database Syst Rev. 2009 Oct;7(4):CD007395.
  • 2
    Nikawa H, Hamada T, Yamashiro H, Kumagai H. A review of in vitro and in vivo methods to evaluate the efficacy of denture cleansers. Int J Prosthodont. 1999 Mar-Apr;12(2):153-9.
  • 3
    Jagger DC, Al-Akhazam L, Harrison A, Rees JS. The effectiveness of seven denture cleansers on tea stain removal from PMMA acrylic resin. Int J Prosthodont. 2002 Nov-Dec;15(6):549-52.
  • 4
    Felton D, Cooper L, Duqum I, Minsley G, Guckes A, Haug S, et al. Evidence-based guidelines for the care and maintenance of complete dentures: a publication of the American College of Prosthodontists. J Prosthodont. 2011 Feb;20 Suppl 1:S1-S12.
  • 5
    Shay K. Denture hygiene: a review and update. J Contemp Dent Pract. 2000 Feb 15;1(2):28-41.
  • 6
    Andre RF, Andrade IM, Silva-Lovato CH, Paranhos HFO, Pimenta FC, Ito IY. Prevalence of mutans streptococci isolated from complete dentures and their susceptibility to mouthrinses. Braz Dent J. 2011;22(1):62-7.
  • 7
    Paranhos HFO, Peracini A, Pisani MX, Oliveira VC, Souza RF, Silva-Lovato CH. Color stability, surface roughness and flexural strength of an acrylic resin submitted to simulated overnight immersion in denture cleansers. Braz Dent J. 2013;24(2):152-6.
  • 8
    Denture cleansers. Council on Dental Materials, Instruments, and Equipment. J Am Dent Assoc. 1983 Jan;106(1):77-9.
  • 9
    Garcia RCMR, Souza Júnior JA, Rached RN, Del Bel Cury AA. Effect of denture cleansers on the surface roughness and hardness of a microwave-cured acrylic resin and dental alloys. J Prosthodont. 2004 Sep;13(3):173-8.
  • 10
    Morris HF, Manz M, Stoffer W, Weir D. Casting alloys: the materials and “The Clinical Effects”. Adv Dent Res. 1992 Sep;6:28-31.
  • 11
    Mori T, Togaya T, Jean-Louis M, Yabugami M. Titanium for removable dentures. I. Laboratory procedures. J Oral Rehabil. 1997 May;24(5):338-41.
  • 12
    Sutton AJ, Rogers PM. Discoloration of a titanium alloy removable partial denture: a clinical report. J Prosthodont. 2001 Jun;10(2):102-4.
  • 13
    Zavanelli RA, Henriques GEP, Ferreira I, Rollo JMDA. Corrosion-fatigue life of commercially pure titanium and Ti-6Al-4V alloys in different storage environments. J Prosthet Dent. 2000 Sep;84(3):274-9.
  • 14
    Paranhos HFO, Davi LR, Peracini A, Soares RB, Lovato CHS, Souza RF. Comparison of physical and mechanical properties of microwave-polymerized acrylic resin after disinfection in sodium hypochlorite solutions. Braz Dent J. 2009;20(4):331-5.
  • 15
    Davi LR, Peracini A, Ribeiro NQ, Soares RB, Silva CH, Paranhos HF, et al. Effect of the physical properties of acrylic resin of overnight immersion in sodium hypochlorite solution. Gerodontology. 2010 Dec;27(4):297-302.
  • 16
    Hong G, Murata H, Li Y, Sadamori S, Hamada T. Influence of denture cleansers on the color stability of three types of denture base acrylic resin. J Prosthet Dent. 2009 Mar;101(3):205-13.
  • 17
    Unlu A, Altay OT, Sahmali S. The role of denture cleansers on the whitening of acrylic resins. Int J Prosthodont. 1996 May-Jun;9(3):266-70.
  • 18
    Peracini A, Davi LR, Ribeiro NQ, Souza RF, Lovato-Silva CH, Paranhos HFO. Effect of denture cleansers on physical properties of heat-polymerized acrylic resin. J Prosthodont Res. 2010 Apr;54(2):78-83.
  • 19
    Felipucci DNB, Davi LR, Paranhos HFO, Bezzon OL, Silva RF, Barbosa Júnior F, et al. Effect of different cleansers on the weight and ion release of removable partial denture: an in vitro study. J Appl Oral Sci. 2011 Oct;19(5):483-7.
  • 20
    Polyzois GL, Yannikakis SA, Zissis AJ, Demetriou PP. Color changes of denture base materials after disinfection and sterilization immersion. Int J Prosthodont. 1997 Jan-Feb;10(1):83-9.
  • 21
    Paranhos HFO, Salles AES, Macedo LD, Silva-Lovato CH, Pagnano VO, Watanabe E. Complete denture biofilm after brushing with specific denture paste, neutral soap and artificial saliva. Braz Dent J. 2013;24(1):47-52.
  • 22
    Barnabe W, Mendonca Neto T, Pimenta FC, Pegoraro LF, Scolaro JM. Efficacy of sodium hypochlorite and coconut soap used as disinfecting agents in the reduction of denture stomatitis, Streptococcus mutans and Candida albicans. J Oral Rehabil. 2004 May;31(5):453-9.
  • 23
    Keyf F, Gungor T. Comparison of effects of bleach and cleansing tablet on reflectance and surface changes of a dental alloy used for removable partial dentures. J Biomater Appl. 2003 Jul;18(1):5-14.
  • 24
    Andrade IM, Cruz PC, Silva-Lovato CH, Souza RF, Souza-Gugelmin MCM, Paranhos HFO. Effect of chlorhexidine on denture biofilm accumulation. J Prosthodont. 2012 Jan;21(1):2-6.
  • 25
    Felipucci DNB, Davi LR, Paranhos HFO, Bezzon OL, Silva RF, Pagnano VO. Effect of different cleansers on the surface of removable partial denture. Braz Dent J. 2011;22(5):392-7.
  • 26
    Davi LR, Felipucci DNB, Souza RF, Bezzon OL, Lovato-Silva CH, Pagnano VO, et al. Effect of denture cleansers on metal Ion release and surface roughness of denture base materials. Braz Dent J. 2012;23(4):387-93.
  • 27
    Robinson JG, Mccabe JF, Storer R. Denture bases: the effects of various treatments on clarity, strength and structure. J Dent. 1987 Aug;15(4):159-65.
  • 28
    Arab J, Newton JP, Lloyd CH. The importance of water temperature in denture cleaning procedures. J Dent. 1988 Dec;16(6):277-81.
  • 29
    Schmalz G, Garhammer P. Biological interactions of dental cast alloys with oral tissues. Dent Mater. 2002 Jul;18(5):396-406.
  • 30
    Backenstose WM, Wells JG. Side effects of immersion-type cleansers on the metal components of dentures. J Prosthet Dent. 1977 Jun;37(6):615-21.