Abstract
Introduction Endodontically treated teeth are usually affected by extensive structure loss requiring the use of intraradicular posts to provide retention and restoration.
Objective An in vitro assessment was performed on the bonding of glass fiber posts to the root dentin.
Material and method Ninety (n = 10) single bovine roots were used in a 3 x 3 x 3 factorial study with subdivided plots: post customization varying the presence and type of resin (without customization, conventional resin, and Bulk Fill resin), light-curing device (Valo, Radii-Cal, Rainbow), and root third (cervical, middle, and apical).
Result For the customization factor, Tukey’s test (5%) showed the superiority of the Bulk Fill (8.16 MPa) and Z350 (7.40 MPa) groups compared to the control group (4.92 MPa), without differing from each other. All light-curing devices differed, showing the superiority of Valo (9.36 MPa), Radii (6.96 MPa) as an intermediate, and the inferiority of Rainbow (4.17 MPa). The cervical root third (7.81 MPa) was superior, the apical third was inferior (5.80 MPa), and the middle third (6.88 MPa) was an intermediate without differing from the others.
Conclusion The customization of glass fiber posts increases the bond strength to the root dentin, regardless of the resin used. There was a compromise in the apical third and when using light-curing devices with lower light intensity.
Descriptors: Resin cement; dental photoinitiators; light-curing of dental adhesives; dental retention posts; intraradicular retainer technique
Resumo
Introdução Dentes com extensa perda de estrutura podem comprometer a retenção das restaurações ao remanescente dental, onde pinos intraradiculares são indicados.
Objetivo Avaliou-se in vitro a união de pinos de fibra de vidro à dentina radicular em função de diferentes modos de reanatomização, fotopolimerizadores e regionalização radicular.
Material e método Noventa (n=10) raízes bovinas uniradiculares foram usadas num estudo fatorial 3 x 3 x 3 com parcelas subdivididas: Reanatomização do pino, variando a presença e tipo de resina (Sem reanatomização, Resina Convencional e Resina Bulkfill); Fotopolimerizador (Valo, Radii-cal, Rainbow); e Terço radicular (cervical, médio e apical).
Resultado O teste de Tukey (5%) evidenciou para o Fator Reanatomização superioridade dos grupos BulkFill (8.16MPa) e Z350 (7.40MPa) ao grupo Controle (4.92MPa), sem diferirem entre si. Todos os fotopolimerizadores diferiram entre si, com superioridade de Valo (9.36MPa), Radii (6.96MPa) intermediário, e inferioridade de Raiwbow (4.17MPa). O terço radicular cervical (7.81MPa) foi superior e o apical inferior (5.80MPa), com o terço médio (6.88MPa) intermediário e sem diferir dos demais.
Conclusão Conclui-se que a reanatomização de pinos de fibra de vidro aumenta a resistência de união à dentina radicular, independentemente da resina utilizada, havendo prejuízo no terço apical e quando são empregados fotopolimerizadores com menor intensidade luminosa.
Descritores: Cimentos de resina; fotoiniciadores dentários; fotopolimerização de adesivos dentários; pinos de retenção dentária; técnica para retentor intrarradicular
INTRODUCTION
Endodontically treated teeth are usually affected by extensive structure loss due to caries disease, cavity preparations, invasive procedures, and the removal of mineral tissues in the root canal access1. This may compromise the retention of restorations because of the reduced amount of tooth remnants, requiring the use of intraradicular posts to provide retention and restoration2,3.
Glass fiber posts are one of the options to restore endodontically treated teeth and, when compared to cast metal retainers, present a modulus of elasticity close to dentin and higher flexural strength, reducing intraradicular stress4. They also associate esthetic properties such as translucency, whiteness, and opacity, which facilitates mimicking the tooth5. These posts also demand a shorter treatment time for the ability to be cemented in one single session and bonding to resin cement, which bonds to dentin, through adhesive techniques6,7.
However, there is not an optimal prefabricated post for each canal due to the unique morphology of each tooth, resulting in maladjustment of the post to the canal, thick cementation line, and penetration failures of cementing agents, which has led to the alternative of customizing intraradicular posts with composite resins for better adaptation to the canal8. The literature is still unclear regarding the materials and protocols for post customization. This is due to the complex procedure of intraradicular adhesion, justified by the unpredictable variation of morphological characteristics of the canal, such as reduced density and diameter of dentinal tubules in the apical regions and difficult moisture control along the root canal9. There is also difficult access of the light emitted by light-curing devices in the deepest areas of the canal, which do not allow light energy to reach the entire root length, decreasing restorative success10.
Therefore, this in vitro study aimed to assess the bond strength of glass fiber posts for different types of customization, light-curing devices, and root regions.
The null hypotheses tested are:
-
a
1- There is no difference in the bond strength of glass fiber posts without customization or customized with different types of resin;
-
b
2- There is no difference in the bond strength of glass fiber posts using different light-curing devices;
-
c
3- There is no difference in the bond strength of glass fiber posts in the different regions of root dentin.
MATERIAL AND METHOD
Experimental Design
This in vitro study presented a factorial experimental design with subdivided plots, including three factors: 1- Customization of glass fiber posts in three levels: A- Post without customization; B- Post customized with conventional resin (Z350-3M); and C- Post customized with Bulk Fill resin (3M) (Chart 1); 2- Light-curing in three levels: I- VALO; II- Radii-Call; and III- Rainbow model LY-A180 (Chart 2); and 3- Root region in three levels with subdivided plots: i- cervical; ii- middle; and iii- apical. The outcome variable was the push-out bond strength test.
Root Selection
Recently extracted bovine incisors were subjected to an analysis of mesiodistal dimensions and original length, allowing the selection of similar units with cylinder canals. From these, 90 (n=10) were selected and maintained in chloramine T for one week for disinfection. After cutting the cervical region perpendicular to the long axis of the tooth with a double-sided diamond disc, under constant irrigation in a Labcut 1010 precision cutting device (Extec, São Paulo, SP, Brazil), the crown portions were discarded. This resulted in roots with a standardized length of 16 mm, which were stored in distilled water in a refrigerator for up to one month to prevent losses of histological properties of the bovine roots.
Root Canal Preparation
The roots were endodontically treated with Kerr files (Maillefer-Dentsply, Ballaigues, Switzerland) up to size 80 memory file, with a standardized working length of 16 mm. The canals were irrigated with distilled water and dried with absorbent paper cones. Then, they were filled with gutta-percha cones and calcium hydroxide-based cement (Sealer 26 - Dentsply, Rio de Janeiro, RJ, Brazil) using the lateral condensation technique.
After one month of storage in artificial saliva at 37°C in an oven, 12 mm of the filling material was removed from the canals with a series of Gates drills (up to #6) to cement the post, which consisted of a #1 conical post with a rough and grooved surface (Reforpost, Angelus, Londrina, PR, Brazil).
Distribution of Treated Roots in the Groups
Next, the roots were randomly distributed in nine groups according to the customization and curing unit, as described in Chart 1.
The samples of each group were subdivided into three groups according to root region: cervical, middle, and apical (n=10).
Post and Canal Preparations
The glass fiber posts were etched for one minute with 37% phosphoric acid (Condac 37, FGM, Joinville, SC, Brazil), washed with water from the triple syringe, air-dried, and silanized (Primer silane - Angelus, Londrina, PR, Brazil). They were dried for one minute and received the application of Scotchbond hydrophobic adhesive (3M ESPE, Saint Paul, Minnesota, USA) and light-cured. All steps were performed according to the manufacturer's instructions. Charts 2 describe the characteristics of light-curing devices, following these cementation protocols respectively:
-
Without customization:
-
A
Glass fiber post
-
1
37% phosphoric acid for one minute;
-
2
Washing for one minute and drying;
-
3
Silane with microbrush and evaporating for one minute;
-
4
Adhesive with microbrush and light-curing for 20 seconds;
-
1
-
B
Canal
-
1
Irrigation with 0.9% saline solution;
-
2
Drying with absorbent paper;
-
3
Self-adhesive cement directly on the canal;
-
4
Positioning the post without customization;
-
5
Light-curing for 40 seconds, root wrapped in aluminum foil.
-
1
-
With customization:
-
A
Glass fiber post
-
1
37% phosphoric acid for one minute;
-
2
Washing for one minute;
-
3
Silane with microbrush and evaporating for one minute;
-
4
Adhesive with microbrush and light-curing for 20 seconds;
-
5
Composite resin modeled to the post and positioned on the canal;
-
6
Initial light-curing for three seconds;
-
7
Removal from the canal and light-curing for 40 seconds;
-
8
37% phosphoric acid for 15 seconds for decontamination;
-
1
-
B
Canal
-
1
Irrigation with 0.9% saline solution;
-
2
Drying with absorbent paper;
-
3
Self-adhesive cement directly on the canal;
-
4
Insertion of the customized post;
-
5
Light-curing for 40 seconds, root wrapped in aluminum foil.
-
1
The specimens identified were maintained in distilled water in an oven at 37°C. After one week, the roots were sectioned with a diamond disc in a Labcut 1010 precision cutting machine (Extec, São Paulo, SP, Brazil), under constant refrigeration, perpendicular to the long axis, and in slices with 1±0.2 mm of thickness. For each root (specimen/sample), nine slices (specimens) were obtained, corresponding to three slices for each root third. The slices were individually identified, maintained in distilled water, and immediately subjected to the mechanical test.
Bond Strength Test (push-out)
The adhesive interfaces of the specimens have a conical and truncated shape and their areas were obtained by measuring canal diameters on the coronal and apical sides of each slice. Their thickness was obtained with the help of a digital caliper (Mitutoyo Sul Americana Ltda, Suzano, SP, Brazil) and the total area, in mm2, was calculated with the following formula: A = π (R2+R1) [h2 + (R2-R1)2]0,5, where π= 3.14; R2= crown radius of the cementation area; R1= apical radius of the cementation area; h= height of the slice.
The specimens were subjected to the push-out test and positioned in a stainless steel metal support with a central perforation with a slightly larger diameter than the adhesive interface (2.0 to 3.8 mm). Due to the conical shape of the posts, the load was applied in the apical-crown direction, from the surface with the smallest diameter, with the post being pushed toward the wider portion of the canal.
The load was applied on a post surface with a tip (diameter varying from 1.3 mm to 0.8 mm) coupled to a universal testing machine (EMIC DL 2000; EMIC, São José dos Pinhais, PR, Brazil) with a cell load of 500 KgF (50 N), at speed of 1.0 mm/min, so it would not contact the adhesive interface.
Conversion of Values
The values obtained during the push-out test were registered in N and converted to MPa with the formula α= F/A, where F, in N, is the maximum force registered at the time of post displacement and A is the adhesive interface area.
Fracture Type Analysis
After the push-out test, the slices were analyzed with light microscopy (DINOLITE plus digital microscope, AnMo Electronics Corporation, Hsinchu, China), with a magnification of 200x, and were classified as: 1- A P/₢ (adhesive failure between cement/resin and post); 2- A C/D (adhesive failure between cement and dentin); 3- CC (cohesive failure of the cement); 4- CD (cohesive failure in dentin); and 5- M (mixed failure).
Statistical Analysis
The factors of customization, light-curing devices, and root thirds were considered. The SigmaPlot 11.0 software was used for the analyses. Normal distribution and homogeneity of variances were verified with the Kolmogorov-Smirnov analyses and Levene test, respectively. The data were processed with three-way ANOVA with subdivided plots and multiple comparisons with Tukey's test, both at p<0.05.
RESULT
There were significant differences between the factors of customization (p<0.001), light-curing device (p<0.001), and root third (p=0.003), but no differences between double (p=0.264; p=0.993; and p=0.779) and triple (p=0.984) interactions. The differences were identified with Tukey's complementary test (5%), showing in the customization factor the superiority of Bulk Fill (8.16 Mpa) and Z350 (7.40 Mpa) groups compared to the control group (4.92 Mpa), without differing from each other. For the light-curing device factor, all groups differed, showing the superiority of Valo (9.36 Mpa), Radii as an intermediate (6.96 Mpa), and the inferiority of Rainbow (4.17 Mpa). For the root third factor, the cervical third (7.81 Mpa) was superior, the apical third was inferior (5.80 Mpa), and the middle third (6.88 Mpa) showed intermediate values without significantly differing from the cervical and apical thirds (Chart 3).
The ACD failure was prevalent for the customization with Bulk Fill and Z350, showing that failure occurs between the cement and dentin, where there is a closer contact. However, the predominant failure mode in the control group was APC, failing the adhesion between post and cement. The CD failures prevailed for the Valo light-curing device due to the extensive conversion potential presented. Radii was an intermediate and Rainbow had the lowest number of cement-dentin failures. The opposite to the conversion degree of light-curing devices causes CC failures, with the highest rates for Rainbow, intermediate for Radii, and Valo with the lowest rates, which confirms the bond strength data (Figure 1).
DISCUSSION
The procedures involving the rehabilitation of dental elements after endodontic treatment with the fixation of posts include several variables susceptible to failures, which may compromise the bond strength of posts to the canal and result in restorative failure11-15. Some of these aspects were assessed in the present study, which showed that the best bond strength results occurred in the cervical region of the canal whose posts had been adapted by the customization procedure (R2 and R3), using the light-curing device with the highest power density (F1) and with the inferiority of the apical third.
The first null hypothesis tested was rejected because there were significant statistical differences between the types of customization. The groups customized with composite resins (R2 and R3) had the highest bond strength results when compared to posts cemented without customization. The best results might be attributed to the close contact of the composite resin modeled to the inner root surface and the consequent smallest thickness of the resin cement required for cementation, reducing polymerization shrinkage stress. This result corroborates studies showing that post retention within root canals is not exclusively adhesive, but also frictional15-19.
The composite resins used for customization, either conventional or Bulk Fill, did not differ regarding dentin bond strength, suggesting that the better adaptation to the canal is more important than the material used18,20. The C-factor of polymerization was reduced in this technique because photoactivation occurs outside the canal, having the post as the only adhesion surface, therefore not presenting polymerization shrinkage stress, following the same principles of indirect crown restorations12. Different results are found in the literature, justified by materials (fluid resins and cement) and customization techniques (directly to the canal), considering that material insertion and light-curing directly to the canal involves two adhesive surfaces (post and canal wall), producing stress in the adhesive interface21-23.
The push-out test was used in the present study for being the most reliable test to assess the bond strength of glass fiber posts to the root dentin because the fracture pattern occurs parallel to the cement/root dentin interface23.
The second null hypothesis was also rejected because there was a significant difference between the groups light-cured with different equipment. The Valo group (F1) showed the highest bond strength means, the Radii group (F2) presented an intermediate value, and the Rainbow group (F3) had the lowest bond strength. This may be justified by the power density of each light-curing device and the different light spectrum. The Valo provides a power density of 1400 mW/cm2, Radii-Call has 1200 mW/cm2, and Rainbow has 900 mW/cm2. This corroborates the principle that the more intense the light, the more photons are available for absorbing photosensitizers, which can then be elevated to the excited state, helping to form more free radicals and initiating and propagating the polymerization process21,22.
It should also be noted that the light potential of a curing unit reduces intensity with depth and does not reach the same absorption level after passing through some structures10,23,24. This is why there were differences in bond strength for the root thirds. The cervical third presented the best results, the middle third was an intermediate, and the apical third had the lowest results, which rejects the third null hypothesis. This may be explained by the insufficient arrival of light to allow the conversion of monomers into polymers1,23. Moreover, light-curing devices with a power of 1500 mW/cm2 presented higher bond strength results, especially in the cervical third22,23. These results agree with previous studies that show that dual resin cement depends on photoactivation to achieve better mechanical properties, recommending the use of translucent glass fiber posts to minimize the issue of light transmission throughout the root extension. They conclude that the ability to transmit light was not significant to obtain an appropriate degree of conversion for the cement, especially in the apical region10,16,20.
Additionally, the morphology along the root presents histological differences, whereas, apically, the dentinal tubules reduce in size and present greater moisture. Residual gutta-percha and insufficient hybridization may also occur24,25. This is seen in the study by Calixto et al.13 in which the lowest bond strength results are found in the apical third for both the morphological factor that reduces the size of dentinal tubules in the root apex and the light potential that decreases along the root length.
Some methodological limitations allow a restricted interpretation of the results, considering that even with the standardization of the root length, variances along the root canal present histological differences. Therefore, further studies are required to assess the relationship between the adjustments of glass fiber posts to the root dentin (canal walls).
CONCLUSION
The customization of glass fiber posts with composite resin increases the bond strength to the root dentin, regardless of the resin used. There was a compromise for bonding on the apical root third and when using light-curing devices with lower light intensity.
-
How to cite: Schoenhals GP, Chaves LP, Naufel FS. Influence of customization and light-curing device on the bond strength of glass fiber posts - in vitro study. Rev Odontol UNESP. 2022;51:e20210058. https://doi.org/10.1590/1807-2577.05821
REFERENCES
-
1 Oz FD, Attar N, Sungur DD. The influence of restorative material and glass fiber posts on fracture strength of endodontically treated premolars after extensive structure loss. Niger J Clin Pract. 2019 Jun;22(6):782-9. http://dx.doi.org/10.4103/njcp.njcp_11_19 PMid:31187762.
» http://dx.doi.org/10.4103/njcp.njcp_11_19 -
2 Andrioli ARV, Coutinho M, Vasconcellos AA, Miranda ME. Relining effects on the push-out shear bond strength of glass fiber posts. Rev Odontol UNESP. 2016;45(4):227-33. http://dx.doi.org/10.1590/1807-2577.14815
» http://dx.doi.org/10.1590/1807-2577.14815 -
3 Freitas TL, Vitti RP, Miranda ME, Brandt WC. Effect of glass fiber post adaptation on push-out bond strength to root dentin. Braz Dent J. 2019 Jul-Aug;30(4):350-5. http://dx.doi.org/10.1590/0103-6440201902491 PMid:31340224.
» http://dx.doi.org/10.1590/0103-6440201902491 -
4 Lorenzetti CC, Bortolatto JF, Ramos ATPR, Shinohara AL, Saad JRC, Kuga MC. The effectiveness of glass ionomer cement as a fiber post cementation system in endodontically treated teeth. Microsc Res Tech. 2019 Jul;82(7):1191-7. http://dx.doi.org/10.1002/jemt.23268 PMid:30920097.
» http://dx.doi.org/10.1002/jemt.23268 -
5 Mankar S, Kumar NS, Karunakaran JV, Kumar SS. Fracture resistance of teeth restored with cast post and core: an in vitro study. J Pharm Bioallied Sci. 2012 Aug;4(6 Suppl 2):S197-202. http://dx.doi.org/10.4103/0975-7406.100200 PMid:23066252.
» http://dx.doi.org/10.4103/0975-7406.100200 -
6 Amižić IP, Baraba A. Esthetic intracanal posts. Acta Stomatol Croat. 2016 Jun;50(2):143-50. http://dx.doi.org/10.15644/asc50/2/7 PMid:27789912.
» http://dx.doi.org/10.15644/asc50/2/7 -
7 Figueiredo FE, Martins-Filho PR, Faria-E-Silva AL. Do metal post-retained restorations result in more root fractures than fiber post-retained restorations? A systematic review and meta-analysis. J Endod. 2015 Mar;41(3):309-16. http://dx.doi.org/10.1016/j.joen.2014.10.006 PMid:25459568.
» http://dx.doi.org/10.1016/j.joen.2014.10.006 -
8 Kadam A, Pujar M, Patil C. Evaluation of push-out bond strength of two fiber-reinforced composite posts systems using two luting cements in vitro. J Conserv Dent. 2013 Sep;16(5):444-8. http://dx.doi.org/10.4103/0972-0707.117522 PMid:24082575.
» http://dx.doi.org/10.4103/0972-0707.117522 -
9 Perdigão J, Gomes G, Augusto V. The effect of dowel space on the bond strengths of fiber posts. J Prosthodont. 2007 May-Jun;16(3):154-64. http://dx.doi.org/10.1111/j.1532-849X.2006.00166.x PMid:17581176.
» http://dx.doi.org/10.1111/j.1532-849X.2006.00166.x -
10 Rueggeberg FA, Giannini M, Arrais CAG, Price RBT. Light curing in dentistry and clinical implications: a literature review. Braz Oral Res. 2017 Aug;31(Suppl 1):e61. http://dx.doi.org/10.1590/1807-3107bor-2017.vol31.0061 PMid:28902241.
» http://dx.doi.org/10.1590/1807-3107bor-2017.vol31.0061 -
11 Sadek FT, Goracci C, Monticelli F, Grandini S, Cury AH, Tay F, et al. Immediate and 24-hour evaluation of the interfacial strengths of fiber posts. J Endod. 2006 Dec;32(12):1174-7. http://dx.doi.org/10.1016/j.joen.2006.07.005 PMid:17174676.
» http://dx.doi.org/10.1016/j.joen.2006.07.005 -
12 Goracci C, Tavares AU, Fabianelli A, Monticelli F, Raffaelli O, Cardoso PC, et al. The adhesion between fiber posts and root canal walls: comparison between microtensile and push-out bond strength measurements. Eur J Oral Sci. 2004 Aug;112(4):353-61. http://dx.doi.org/10.1111/j.1600-0722.2004.00146.x PMid:15279655.
» http://dx.doi.org/10.1111/j.1600-0722.2004.00146.x -
13 Calixto LR, Bandéca MC, Clavijo V, Andrade MF, Vaz LG, Campos EA. Effect of resin cement system and root region on the push-out bond strength of a translucent fiber post. Oper Dent. 2012 Jan-Feb;37(1):80-6. http://dx.doi.org/10.2341/11-035-L PMid:21942240.
» http://dx.doi.org/10.2341/11-035-L -
14 Sarkis-Onofre R, Skupien JA, Cenci S, Moraes R, Pereira-Cenci T. The role of resin cement on bond strength of glass-fiber posts luted into root canals: a systematic review and meta-analysis of in vitro studies. Oper Dent. 2014 Jan-Feb;39(1):E31-44. http://dx.doi.org/10.2341/13-070-LIT PMid:23937401.
» http://dx.doi.org/10.2341/13-070-LIT -
15 Marcos RM, Kinder GR, Alfredo E, Quaranta T, Correr GM, Cunha LF, et al. Influence of the resin cement thickness on the push-out bond strength of glass fiber posts. Braz Dent J. 2016 Sep-Oct;27(5):592-8. http://dx.doi.org/10.1590/0103-6440201600886 PMid:27982240.
» http://dx.doi.org/10.1590/0103-6440201600886 -
16 Latempa AM, Almeida SA, Nunes NF, da Silva EM, Guimarães JG, Poskus LT. Techniques for restoring enlarged canals: an evaluation of fracture resistance and bond strength. Int Endod J. 2015 Jan;48(1):28-36. http://dx.doi.org/10.1111/iej.12272 PMid:24697574.
» http://dx.doi.org/10.1111/iej.12272 -
17 Tay FR, Loushine RJ, Lambrechts P, Weller RN, Pashley DH. Geometric factors affecting dentin bonding in root canals: a theoretical modeling approach. J Endod. 2005 Aug;31(8):584-9. http://dx.doi.org/10.1097/01.don.0000168891.23486.de PMid:16044041.
» http://dx.doi.org/10.1097/01.don.0000168891.23486.de -
18 Ohlmann B, Fickenscher F, Dreyhaupt J, Rammelsberg P, Gabbert O, Schmitter M. The effect of two luting agents, pretreatment of the post, and pretreatment of the canal dentin on the retention of fiber-reinforced composite posts. J Dent. 2008 Jan;36(1):87-92. http://dx.doi.org/10.1016/j.jdent.2007.11.002 PMid:18079034.
» http://dx.doi.org/10.1016/j.jdent.2007.11.002 - 19 Gomes GM, Rezende EC, Gomes OM, Gomes JC, Loguercio AD, Reis A. Influence of the resin cement thickness on bond strength and gap formation of fiber posts bonded to root dentin. J Adhes Dent. 2014 Feb;16(1):71-8. PMid:24223416.
-
20 D’Arcangelo C, Cinelli M, De Angelis F, D’Amario M. The effect of resin cement film thickness on the pullout strength of a fiber-reinforced post system. J Prosthet Dent. 2007 Sep;98(3):193-8. http://dx.doi.org/10.1016/S0022-3913(07)60055-9 PMid:17854620.
» http://dx.doi.org/10.1016/S0022-3913(07)60055-9 -
21 Braga RR, Cesar PF, Gonzaga CC. Mechanical properties of resin cements with different activation modes. J Oral Rehabil. 2002 Mar;29(3):257-62. http://dx.doi.org/10.1046/j.1365-2842.2002.00821.x PMid:11896842.
» http://dx.doi.org/10.1046/j.1365-2842.2002.00821.x -
22 Galhano GA, de Melo RM, Barbosa SH, Zamboni SC, Bottino MA, Scotti R. Evaluation of light transmission through translucent and opaque posts. Oper Dent. 2008 May-Jun;33(3):321-4. http://dx.doi.org/10.2341/07-93 PMid:18505223.
» http://dx.doi.org/10.2341/07-93 -
23 Roberts HW, Leonard DL, Vandewalle KS, Cohen ME, Charlton DG. The effect of a translucent post on resin composite depth of cure. Dent Mater. 2004 Sep;20(7):617-22. http://dx.doi.org/10.1016/j.dental.2003.10.004 PMid:15236935.
» http://dx.doi.org/10.1016/j.dental.2003.10.004 -
24 Faria e Silva AL, Arias VG, Soares LE, Martin AA, Martins LR. Influence of fiber-post translucency on the degree of conversion of a dual-cured resin cement. J Endod. 2007 Mar;33(3):303-5. http://dx.doi.org/10.1016/j.joen.2006.11.015 PMid:17320720.
» http://dx.doi.org/10.1016/j.joen.2006.11.015 -
25 Ferrari M, Mannocci F. A ‘one-bottle’ adhesive system for bonding a fibre post into a root canal: an SEM evaluation of the post-resin interface. Int Endod J. 2000 Jul;33(4):397-400. http://dx.doi.org/10.1046/j.1365-2591.2000.00310.x PMid:11307217.
» http://dx.doi.org/10.1046/j.1365-2591.2000.00310.x
Publication Dates
-
Publication in this collection
22 Apr 2022 -
Date of issue
2022
History
-
Received
16 Nov 2021 -
Accepted
09 Mar 2022