Open-access Biomechanical analysis of narrow dental implants for maxillary anterior rehabilitation

Análise biomecânica de implantes de diâmetro reduzido para reabilitação da região anterior da maxila

Abstract

Introduction  Narrow diameter implants biomechanics knowledge indicates safe dimensions for clinical use.

Objective  Purpose of the present study was biomechanically to compare regular and narrow diameter implants to support single implant-supported prosthesis in the anterior region of the maxilla by 3D finite element analysis (3D-FEA).

Material and method  Four 3D-FEA models were developed form CT scan recompositing and literature data: a bone block in the right upper lateral incisive region with implant and crown. M1: 3.75 x 13 mm, M2: 3.75 x 8.5 mm, M3: 2.9 x 13 mm and M4: 2.9 x 8.5 mm. It was applied load was of 178 N at 0, 30 and 60 degrees in relation to implant long axis. Von Mises stress, maximum principal stress and microdeformation maps were evaluated.

Result  M3 and M4 did show higher tension and higher microdeformation values than M1 and M2, especially when inclined forces were applied. However, M3 presented enhanced biomechanical behavior than M4.

Conclusion  It can be concluded that reduce the diameter of the implants can disadvantage to the biomechanics during the application of forces, but the distribution and intensity of the stresses, as well as the micro deformation values can be improved if the length of the implant is increased.

Descriptors:  Dental implantation; bone; stress, mechanical; finite element analysis

Resumo

Introdução  O conhecimento da biomecânica de implantes de diâmetro reduzido indica dimensões seguras para uso clínico.

Objetivo  O objetivo do presente estudo foi comparar biomecanicamente implantes de diâmetro regular e reduzido para suporte de próteses implantossuportadas unitárias na região anterior da maxila por meio de análise de elementos finitos 3D (3D-FEA).

Material e método  Quatro modelos 3D-FEA foram desenvolvidos a partir de recomposição de tomografia computadorizada e dados da literatura: um bloco ósseo na região incisiva lateral superior direita com implante e coroa. M1: 3,75 x 13 mm, M2: 3,75 x 8,5 mm, M3: 2,9 x 13 mm e M4: 2,9 x 8,5 mm. Foi aplicada carga de 178 N nos ângulos 0, 30 e 60 graus em relação ao longo eixo do implante. Foram avaliados mapas de tensão de Von Mises, tensão principal máxima e microdeformação. Resultado: M3 e M4 apresentaram maiores valores de tensão e microdeformação que M1 e M2, principalmente quando foram aplicadas forças inclinadas. Porém, M3 apresentou comportamento biomecânico melhor do que M4.

Conclusão  Pode-se concluir que reduzir o diâmetro dos implantes pode prejudicar a biomecânica durante a aplicação de forças, mas a distribuição e intensidade das tensões, bem como os valores de microdeformação podem ser melhorados se o comprimento do implante for aumentado.

Descritores:  Implantes dentários; osso; estresse mecânico; análise de elementos, finitos

INTRODUCTION

Clinical success of the use of implants in single or multiple restorations, including in the anterior maxillary region, is already established1-3. The success of this treatment depends on correct planning and bone availability so that the appropriate size of the implant is correctly indicated and installed, under adequate angulation4. For cases which there is little bone availability, installing implants associated with grafts is considered a good treatment option2. However, whenever there is a reduction in bone availability, the surgical risk of fenestration and/or dehiscence increases, may compromise treatment. This bone availability can also be considered in the mesio-distal sense. There are studies showing safe and ideal limits for implant placement for papilla formation and to prevent bone resorption5. These situations represent greater risks for rehabilitation with implants and, often, the only option is to install narrow diameter implants2. Narrow implants are usually less than 3.75 mm in diameter and are indicated for the rehabilitation of upper and lower lateral incisors whose mesiodistal bone availability is less than 6 mm or the thickness is less than 5 mm6. In these situations, using small diameter implants there is a significant decrease in the need for bone grafts6, and associated surgical complications, such as increased healing time, additional surgical costs, and surgical morbidity2,6. However, the decrease in the diameter of the implantation also decreases the osseointegration surface, which can cause biomechanical damage to the implant or screw6, or even overload the bone tissue. Although some recent results suggest that the reduction of the implant diameter does not influence its survival rates or marginal bone loss1,7,8 it is important to consider results that contradict this statement7,8.

Studies indicate that internal implant connections are more biomechanically favorable for stress distribution than external hexagon connections9,10. This has driven the use and indication of Morse taper implants, especially for unitary rehabilitation. These implants have shown lower stress levels than external hexagon implants11. In addition, they have high success rates reaching 97.25% in the maxilla12 and decrease the risk of loosening of the screws commonly observed in external hexagon implants13. Even more, biologically, they decrease bone resorption rates5, being even below the classic levels of success described for the first year of function, less than 1.5 mm, and not more than 0.2 mm in each following year14. However, as it is a current trend, there are few studies focusing on the biomechanics of narrow diameter implants or clinical and biomechanical parameters to indicate safe dimensions for clinical use, especially with internal connections that, in theory, generate narrower walls and may compromise the biomechanical resistance of the implants.

For biomechanical studies, several methodologies can be used. Among these, finite element analysis (FEA) has proved to be an excellent tool, as it allows computer simulation of a physical model that, if well applied, can have its results extrapolated to the daily clinic9,10,15. The purpose of this study was to analyze biomechanically, using the 3D FEA, the stress distribution in anterior unitary rehabilitation of the lateral incisor comparing narrow implants (2.9 mm in diameter) with regular implants (3.75 mm in diameter). It was also evaluated different lengths (8.5 mm and 13.0 mm) seeking to identify possible biomechanical risks for the implant, prosthetic components, and peri-implant bone. Null hypothesis is there is no significant difference in the stress distribution using narrow implants compared to standard diameter implants.

MATERIAL AND METHOD

Experimental design and model description

It was evaluated implant diameter (2.9 mm and 3.75 mm) and implant length (8.5 mm and 13 mm) in bone type III. Four 3D models were made and submitted to the simulated loading in 3 directions (0, 30 and 60 degrees in relation to the long axis of the implant), totaling 12 finite element analyzes as previously described15,16. Table 1 shows characteristics of the models. All models received two natural teeth, central and canine incisor, with simulation of their ligaments interconnected to the cortical bone tissue. The implant of each model was placed in the position of the lateral incisor, with a diameter of 2.9 or 3.75 mm, with 8.5 mm or 13 mm in length. The tested situation was that of a zirconia crown of the lateral incisor cemented on universal trunnions compatible with the implant.

Table 1
Description of the models

Tridimensional finite element methodology

It was used a high-performance workstation with following software’s: InVesalius 3.0 (CTI, São Paulo, Brazil), Rhinoceros 3D 4.0 (NURBS Modeling for Windows, Robert McNeel & Associates, Seattle, USA), Solidworks 2015 (SolidWorks Corp, Massachusetts, USA) and ANSYS 19.2 (Southpointe, PA, USA).

Tridimensional modeling

Modeling methodology was based on previous studies9-13,17-25. Each model consisted of a bone block from the maxillary anterior region, with an infra bone Morse taper implant (1.5 mm), supporting a cemented metalloceramic crown. Bone tissue design was obtained by tomographic recompositing with software InVersalius 3.0 (CTI, São Paulo, Brazil). The design obtained by the recompositing was simplified in the software Rhinoceros 3D (NURBS modeling for Windows, Seattle, USA) to allow and optimize the computational calculation. The cortical bone was obtained by an offset tool in this software, thickness of 1mm, leaving the inside of the model simulated with trabecular bone, simulating bone type III. For each situation, bone tissue was modeled 1 mm around the implant (apical, buccal, and lingual). Implant and components geometries (universal sleeve and cementation cylinder) were obtained by simplifying the original design in the SolidWorks software (SolidWorks, Massachusetts, USA) which were later simplified in the Rhinoceros 3D software (NURBS modeling for Windows, Seattle, USA) without prejudice the geometry for the analyzes calculating. Metalloceramic crown was made like a previous study15 composed of infrastructure and zirconia coating, cemented on a universal piece measuring 3.25 x 4.0 x 4.0 mm. Crown adjustments were made from tomographic recompositing so that the piece fit perfectly inside, with approximate ceramic dimensions of 1 mm on the buccal, lingual, mesial, and distal surfaces and 2 mm on the incisal region. The cementation line was simulated with a thickness of 0.5 mm.

Finite element analysis configuration

Finite element analysis also followed previous studies methodology9,10,15,16 and was subdivided into 3 phases: pre-processing (discretization of the models and configuration of the analysis), resolution (mathematical calculation) and post-processing (visualization of the results). Finite element analysis software was ANSYS 19.0 (Southpointe, PA, USA). First step was to export the models to carry out the discretization model by model, in STEP file format. Meshes were made using solid parabolic elements, with the mechanical properties of all material, using solid parabolic elements using the CFD mesh technique. Table 2 shows the mechanical properties of each material, and the study supported their choice. All material was isotropic, homogeneous, and linearly elastic. Almost all interface contacts (ceramic/cement, cement/universal sleeve, universal sleeve/implant, implant/cortical bone, implant/trabecular bone/cortical bone/trabecular bone) were assumed to be glued. Only the interproximal contacts of the central incisor / lateral incisor, canine / lateral incisor were assumed to be juxtaposed. The restrictions were assumed to be fixed in directions 𝑥, 𝑦, and 𝑧 and applied to the lateral sections of the bone block construction, referring to the fixation in the rest of the maxilla, for each proposed model. The simulated loads were like the previous study25 with an intensity of 178 N and applied at 0, 30 and 60 degrees in relation to the long axis of the implant, applied in the palatal region approximately 2 mm below the incisal edge, in the region corresponding to the contact point with the antagonistic tooth. Then, the linear analysis was generated and exported for calculation (processing) in the ANSYS software.

Table 2
Materials mechanical properties

The analysis was carried out by Von Mises stress (applied for static resistance of ductile materials, such as titanium and Ni-Cr alloy), principal maximum stress (MPa) maps and microdeformation (με) (applied to friable materials, such as bone tissue). Regions of interest, such as the bone / implant interface and the implant itself, were zoomed out in view of the need for better observation of qualitative results.

RESULT

Von Mises stresses

In axial loading (0º), a similar pattern was observed in the stress distribution among the models evaluated. There was a slight increase in the stress observed in the region of the intermediaries. At 30º loading, it was possible to verify a considerable increase in stress at the implant/intermediate contact interface, both palatal and buccal, compared to axial loading. At 60º loading, it was possible to observe higher concentrations of stresses in the region of the intermediaries, when compared with the other loads. In addition, it was observed that the larger the implant diameter, the smaller and more uniform the stress distribution in components and implants. Figure 1 show images of the Von Mises stress maps for the different implant diameters and lengths.

Figure 1
Comparison of Von Mises maps to stress distribution on narrow and regular implants with different lengths, components, and crown.

Principal maximum stress on bone tissue

It was observed correspondence with the Von Mises stress results. An increase in principal maximum stress levels was observed as the loading inclination increased, with higher stress concentrations in the region of cortical and trabecular bone tissue near the implant neck. In axial loading (0º), very similar maps with small values of traction and compression were observed. It was not observed the influence of the diameter of the implants in the stress distribution or concentration in the region of the cortical and trabecular bone tissue. At 30º loading, it was observed higher concentrations of traction stress in the cervical region of bone tissue. Also, it was observed that regular diameter implants (3.75 mm) did show smaller concentration areas of traction/compression stresses, when compared with narrow implants (2.9 mm) in the cortical bone. The analysis of the 60º loading did show the same pattern of distribution of the 30º loading, being more favorable (with lower values of traction and compression) for the models with 3.75 mm when compared with the 2.9 mm models, both cortical and trabecular bone. Figure 2 show images of the principal maximum stress maps for the different implant diameters and lengths.

Figure 2
Maximum principal stress maps for narrow and regular implants with different lengths and stress distribution on cortical and trabecular bone tissue.

Microdeformation (με)

In axial loading (0º), it was observed similar microdeformation distribution pattern for all experimental models, with slight deformations in the cervical region near the implant neck, in the first threads and at the apex of the implants. In the oblique loadings (30º and 60º) it was observed that narrow diameter implants (2.9 mm) presented higher values of microdeformation in comparison with the implants of regular diameter (3.75 mm), with a slight concentration of microdeformation in the vestibular region in the cortical tissue. Figure 3 show images of the microdeformation maps for the different implant diameters and lengths.

Figure 3
Bone tissue microdeformation (με) maps for narrow and regular implants with different lengths.

DISCUSSION

Null hypothesis of the present study was no significant difference in stress distribution when using narrow implants compared to regular diameter implants. This hypothesis was rejected once the implant diameter influenced the biomechanical behavior of the implants, their components and bone tissue. Considering the reduction of the implant diameter to 2.9 mm promoted an increase in the distribution and intensity of the traction/compression stresses, as well as in the microdeformation values ​​compared to standard diameter implants, it can be inferred that these results corroborate a recent meta-analysis in which it was observed that the use of small diameter implants in single prosthetic crowns could be associated with greater marginal bone loss8. On the other hand, the results observed here and those observed by Telles et al.8 contradict another recent meta-analysis that compared clinical performance after 1 and 3 years of regular or reduced diameter implants9. The results of Ma et al.7 demonstrated that the implant diameter did not interfere with marginal bone loss or rates survival of implants and prostheses even after 1 and 3 years. The authors also suggested that the use of small diameter implants instead of combining procedures to increase bone tissue and regular diameter implants also did not influence the results in the medium and long term. In addition, only mechanical simulation was performed, discarding any biological factor from the interaction, which can lead to other results.

The models of the present study presented implants composed of titanium alloy and trabecular bone around 1 mm of the implant (apical, buccal, and lingual). In this context, it is important to consider systematic reviews that evaluated whether the composition of the implants could influence the results observed when small diameter implants are used17,18. The studies compared the clinical results obtained with the use of small diameter implants with alloy compounds titanium or a special alloy of titanium and zirconia (Ti-Zr) suggested to have superior mechanical resistance. Studies have shown that Ti-Zr implants have similar clinical performance to pure titanium alloy implants, without considering the anatomical region and the type of prosthetic connection17,18.

Regarding the remaining bone tissue around the implant, the results of the present study can be compared to studies that evaluated the influence of the distance between the narrow diameter implant and adjacent teeth. Controversial results have been observed in the literature19,20. Galindo-Moreno et al.20 demonstrated, through a prospective clinical study in 59 patients, that the distance between the narrow diameter implant and the adjacent teeth does not significantly influence the marginal bone levels in the tooth or implant, and that bone loss marginal occurred less frequently in smaller spaces. On the other hand, Wilson, Johnson6 carried out a retrospective observational study using CT scans of anterior teeth to assess the frequency with which these teeth presented favorable mesio-distal and vestibulo-lingual alveolar spaces for possible implant installation. In the anterior region, the same area evaluated in the present study, the sites of the lateral incisors were more frequent in presenting a favorable mesio-distal space. In the maxillary lateral incisors that are the same teeth evaluated in the present study, 22% (left) and 27% (right) of the sites offered less than 2 mm between the implant platform and the adjacent tooth. More than half of these teeth exhibited buccolingual space less than 4 mm from the implant diameter. Thus, the authors concluded that considerable proportions of the maxillary lateral incisors may be at risk of developing unfavorable peri-implant bone thickness when narrow diameter implants are used. It was also suggested that professionals should consider small diameter implants and methods of replacing non-implanted teeth for patients with a lack of upper lateral incisors6. Still, it must be considered that if Morse taper implant was used, there is the possibility of leaving the pieces more centralized, without compromising the adjacent bone; therefore, favoring even the maintenance of bone tissue, even if 3.75 mm or 3.5 mm diameter implants were used.

Schiegnitz, Al-Nawas1 performed a systematic review with meta-analysis to assess the survival rate of different categories of narrow diameter implants and compare them with regular diameter implants. Small diameter implants were classified into Category 1 (diameter <3.0 mm), Category 2 (diameter 3–3.25 mm) and Category 3 (diameter 3.3–3.5 mm). Studies with at least 10 patients and 12 months of follow-up were included. In relation to Category 1, which includes the implants used in the present study, a survival rate of 94.7 ± 5% was observed and the meta-analysis indicated a significantly lower survival rate than regular diameter implants. In this context, it is also important to consider that Category 1 implants were included in the study, regardless of the area (anterior / posterior) or type of prosthesis (cemented / screwed), which may have influenced the results.

Other possible influencing factors on the results obtained with the use of small diameter implants have been evaluated and discussed in the literature, such as the speed of bone drilling20, the presence/absence of systemic disorders in patients such as obesity21 time for installation of the occlusal load22,23 and the implant length24. In the present study, the implant lengths evaluated were 8.5 mm and 13 mm. The increase in the length of the implant favored the distribution of stresses, reduced its intensity, and promoted lower values of microdeformation, especially for implants with reduced diameter. These results corroborate other results already observed in the literature. Pellizzer et al.25 evaluated the biomechanical behavior of different lengths (7.0 mm, 8.5 mm, 10 mm, 11.5 mm, 13 mm and 15 mm) of regular diameter implants through photoelasticity. It was observed that the increase in length allowed a better distribution of stresses in the peri-implant region, and implants with a length above 11.5 mm did show a significant reduction in stresses, when compared with the other models. Kilic, Doganay4 carried out a study using the 3D FEA method to compare the stress distribution of different implant diameters in a vertical or inclined position. Different implant lengths and quantities were also evaluated. Implants that were short and had vertical inclination and showed lower stress values. Although all stress values ​​showed slight increases in reduced implant diameters, stress values, including 3.3 mm diameter implants, were within physiological limits. The authors concluded that increasing the number or diameter of implants may have a positive effect on their survival. In addition, when narrow diameter implants need to be inserted in the inclined implant concept, the combination with short implants can be recommended for long-term success.

Previous studies that have also been carried out using the 3D FEA method have shown that the type of bone may have9 or not have10 influence the stress distribution when implants are tested for vertical or oblique occlusal loads. The type of bone used here was type III. New studies may suggest whether type I, II or IV bones could present different results when narrow diameter implants are used. The geometry of the implant (Morse taper) and the type of prosthetic retention (cementation) were not variables used in the present study, but their choice corroborates previous studies that demonstrated better results in the distribution of stress when the same analysis was performed on diameter implants regular12,13,17-25.

CONCLUSION

Within the limits of this study, it can be concluded that, for borderline cases of bone quantity, reduction of the implant diameter may disadvantage the biomechanics during the application of forces, but the distribution and intensity of the stresses, as well as the microdeformation values can be improved if the implant length is increased.

  • How to cite: Santinoni CS, Batista VES, Oliveira HFF, Lemos CAA, Cruz RS, Verri FR. Biomechanical analysis of narrow dental implants for maxillary anterior rehabilitation. Rev Odontol UNESP. 2023;52:e20230027. https://doi.org/10.1590/1807-2577.02723

REFERENCES

  • 1 Schiegnitz E, Al-Nawas B. Narrow-diameter implants: a systematic review and meta-analysis. Clin Oral Implants Res. 2018 Oct;29(Suppl 16):21-40. http://dx.doi.org/10.1111/clr.13272 PMid:30328192.
    » http://dx.doi.org/10.1111/clr.13272
  • 2 Anitua E, Saracho J, Begoña L, Alkhraisat MH. Long-term follow-up of 2.5-mm narrow-diameter implants supporting a fixed prostheses. Clin Implant Dent Relat Res. 2016 Aug;18(4):769-77. http://dx.doi.org/10.1111/cid.12350 PMid:25913652.
    » http://dx.doi.org/10.1111/cid.12350
  • 3 Ioannidis A, Gallucci GO, Jung RE, Borzangy S, Hämmerle CH, Benic GI. Titanium-zirconium narrow-diameter versus titanium regular-diameter implants for anterior and premolar single crowns: 3-year results of a randomized controlled clinical study. J Clin Periodontol. 2015 Nov;42(11):1060-70. http://dx.doi.org/10.1111/jcpe.12468 PMid:26440201.
    » http://dx.doi.org/10.1111/jcpe.12468
  • 4 Kilic E, Doganay O. Evaluation of stress in tilted implant concept with variable diameters in the atrophic mandible: three-dimensional finite element analysis. J Oral Implantol. 2020 Feb;46(1):19-26. http://dx.doi.org/10.1563/aaid-joi-D-19-00066 PMid:31647683.
    » http://dx.doi.org/10.1563/aaid-joi-D-19-00066
  • 5 Tarnow DP, Cho SC, Wallace SS. The effect of inter-implant distance on the height of inter-implant bone crest. J Periodontol. 2000 Apr;71(4):546-9. http://dx.doi.org/10.1902/jop.2000.71.4.546 PMid:10807116.
    » http://dx.doi.org/10.1902/jop.2000.71.4.546
  • 6 Wilson JP, Johnson TM. Frequency of adequate mesiodistal space and faciolingual alveolar width for implant placement at anterior tooth positions. J Am Dent Assoc. 2019 Sep;150(9):779-87. http://dx.doi.org/10.1016/j.adaj.2019.05.003 PMid:31439205.
    » http://dx.doi.org/10.1016/j.adaj.2019.05.003
  • 7 Ma M, Qi M, Zhang D, Liu H. The clinical performance of narrow diameter implants versus regular diameter implants: a meta-analysis. J Oral Implantol. 2019 Dec;45(6):503-8. http://dx.doi.org/10.1563/aaid-joi-D-19-00025 PMid:31536434.
    » http://dx.doi.org/10.1563/aaid-joi-D-19-00025
  • 8 Telles LH, Portella FF, Rivaldo EG. Longevity and marginal bone loss of narrow-diameter implants supporting single crowns: a systematic review. PLoS One. 2019 Nov;14(11):e0225046. http://dx.doi.org/10.1371/journal.pone.0225046 PMid:31710656.
    » http://dx.doi.org/10.1371/journal.pone.0225046
  • 9 Lemos CAA, Verri FR, Santiago JF Jr, Almeida DAF, Batista VE, Noritomi PY, et al. Retention system and splinting on morse taper implants in the posterior maxilla by 3D finite element analysis. Braz Dent J. 2018 Jan-Feb;29(1):30-35. https://doi.org/10.1590/0103-6440201801492
    » https://doi.org/10.1590/0103-6440201801492
  • 10 Santiago JF Jr, Verri FR, Almeida DA, de Souza Batista VE, Lemos CA, Pellizzer EP. Finite element analysis on influence of implant surface treatments, connection and bone types. Mater Sci Eng C. 2016 Jun;63:292-300. http://dx.doi.org/10.1016/j.msec.2016.02.061 PMid:27040222.
    » http://dx.doi.org/10.1016/j.msec.2016.02.061
  • 11 Coelho Goiato M, Pesqueira AA, Falcón-Antenucci RM, Dos Santos DM, Haddad MF, Bannwart LC, et al. Stress distribution in implant-supported prosthesis with external and internal implant-abutment connections. Acta Odontol Scand. 2013 Mar;71(2):283-8. http://dx.doi.org/10.3109/00016357.2012.672823 PMid:22486241.
    » http://dx.doi.org/10.3109/00016357.2012.672823
  • 12 Mangano C, Mangano F, Piattelli A, Iezzi G, Mangano A, La Colla L. Prospective clinical evaluation of 307 single-tooth morse taper-connection implants: a multicenter study. Int J Oral Maxillofac Implants. 2010 Mar-Apr;25(2):394-400. PMid:20369101.
  • 13 Balshi TJ, Hernandez RE, Pryszlak MC, Rangert B. A comparative study of one implant versus two replacing a single molar. Int J Oral Maxillofac Implants. 1996 May-Jun;11(3):372-8. PMid:8752558.
  • 14 Albrektsson T, Zarb GA. Determinants of correct clinical reporting. Int J Prosthodont. 1998 Sep-Oct;11(5):517-21. PMid:9922743.
  • 15 Ramos Verri F, Santiago JF Jr, de Faria Almeida DA, de Oliveira GB, de Souza Batista VE, Marques Honório H, et al. Biomechanical influence of crown-to-implant ratio on stress distribution over internal hexagon short implant: 3-D finite element analysis with statistical test. J Biomech. 2015 Jan;48(1):138-45. http://dx.doi.org/10.1016/j.jbiomech.2014.10.021 PMid:25435384.
    » http://dx.doi.org/10.1016/j.jbiomech.2014.10.021
  • 16 Verri FR, Batista VE, Santiago JF Jr, Almeida DA, Pellizzer EP. Effect of crown-to-implant ratio on peri-implant stress: a finite element analysis. Mater Sci Eng C. 2014 Dec;45:234-40. http://dx.doi.org/10.1016/j.msec.2014.09.005 PMid:25491825.
    » http://dx.doi.org/10.1016/j.msec.2014.09.005
  • 17 Ha SR. Biomechanical three-dimensional finite element analysis of monolithic zirconia crown with different cement type. J Adv Prosthodont. 2015 Dec;7(6):475-83. http://dx.doi.org/10.4047/jap.2015.7.6.475 PMid:26816578.
    » http://dx.doi.org/10.4047/jap.2015.7.6.475
  • 18 Badran Z, Struillou X, Strube N, Bourdin D, Dard M, Soueidan A, et al. Clinical performance of narrow-diameter titanium-zirconium implants: a systematic review. Implant Dent. 2017 Apr;26(2):316-23. http://dx.doi.org/10.1097/ID.0000000000000557 PMid:28114266.
    » http://dx.doi.org/10.1097/ID.0000000000000557
  • 19 Iegami CM, Uehara PN, Sesma N, Pannuti CM, Tortamano Neto P, Mukai MK. Survival rate of titanium-zirconium narrow diameter dental implants versus commercially pure titanium narrow diameter dental implants: a systematic review. Clin Implant Dent Relat Res. 2017 Dec;19(6):1015-22. http://dx.doi.org/10.1111/cid.12527 PMid:28853215.
    » http://dx.doi.org/10.1111/cid.12527
  • 20 Galindo-Moreno P, Padial-Molina M, Nilsson P, King P, Worsaae N, Schramm A, et al. The influence of the distance between narrow implants and the adjacent teeth on marginal bone levels. Clin Oral Implants Res. 2017 Jun;28(6):704-12. http://dx.doi.org/10.1111/clr.12867 PMid:27154057.
    » http://dx.doi.org/10.1111/clr.12867
  • 21 Alshiddi IF, Alsahhaf A, Alshagroud RS, Al-Aali KA, Vohra F, Abduljabbar T. Clinical, radiographic, and restorative peri-implant measurements of narrow and standard diameter implants in obese and nonobese patients: a 3-year retrospective follow-up study. Clin Implant Dent Relat Res. 2019 Aug;21(4):656-61. http://dx.doi.org/10.1111/cid.12798 PMid:31172671.
    » http://dx.doi.org/10.1111/cid.12798
  • 22 Galindo-Moreno P, Nilsson P, King P, Worsaae N, Schramm A, Padial-Molina M, et al. Clinical and radiographic evaluation of early loaded narrow-diameter implants: 5-year follow-up of a multicenter prospective clinical study. Clin Oral Implants Res. 2017 Dec;28(12):1584-91. http://dx.doi.org/10.1111/clr.13029 PMid:28626888.
    » http://dx.doi.org/10.1111/clr.13029
  • 23 Maiorana C, King P, Quaas S, Sondell K, Worsaae N, Galindo-Moreno P. Clinical and radiographic evaluation of early loaded narrow-diameter implants: 3 years follow-up. Clin Oral Implants Res. 2015;26(1):77-82. http://dx.doi.org/10.1111/clr.12281 PMid:25650268.
    » http://dx.doi.org/10.1111/clr.12281
  • 24 Demenko V, Linetskiy I, Linetska L, Yefremov O. Load-carrying capacity of short implants in edentulous posterior maxilla: a finite element study. Med Eng Phys. 2019 Sep;71:30-7. http://dx.doi.org/10.1016/j.medengphy.2019.02.003 PMid:31285136.
    » http://dx.doi.org/10.1016/j.medengphy.2019.02.003
  • 25 Pellizzer EP, Santiago Jr JF, de Souza Batista VE, Mello CC, Lopes LFTP, Almeida DAF, et al. Influência do aumento do comprimento de implantes dentários. Rev Cir Traumatol Buco-Maxilo-Fac 2013 Jul-Set;13(3):87-94.

Publication Dates

  • Publication in this collection
    27 Nov 2023
  • Date of issue
    2023

History

  • Received
    20 Oct 2023
  • Accepted
    23 Oct 2023
location_on
Universidade Estadual Paulista Júlio de Mesquita Filho Rua Humaitá, 1680 - Caixa Postal 331, 14801-903 Araraquara,São Paulo,SP, Tel.: (55 16) 3301-6376, Fax: (55 16) 3301-6433 - Araraquara - SP - Brazil
E-mail: adriana@foar.unesp.br
rss_feed Acompanhe os números deste periódico no seu leitor de RSS
Acessibilidade / Reportar erro