Open-access Comparison and calibration of numerical models from monitoring data of a reinforced concrete highway bridge

Abstracts

The last four decades were important for the Brazilian highway system. Financial investments were made so it could expand and many structural solutions for bridges and viaducts were developed. In parallel, there was a significant raise of pathologies in these structures, due to lack of maintenance procedures. Thus, this paper main purpose is to create a short-term monitoring plan in order to check the structural behavior of a curved highway concrete bridge in current use. A bridge was chosen as a case study. A hierarchy of six numerical models is shown, so it can validate the bridge's structural behaviour. The acquired data from the monitoring was compared with the finest models so a calibration could be made.

short-term monitoring; SAP2000; Midas FX+; DIANA; numerical modelling


As últimas quatro décadas foram importates para o desenvolvimento da malha rodoviária brasileira. O país recebeu incentivos financeiros à sua expansão e diversas soluções estruturais para pontes e viadutos foram criadas. Em paralelo a este desenvolvimento, houve nos últimos anos um crescimento significativo dessas estruturas em estágio avançado de deterioração devido à ausência de programas de manutenção preventiva. Dessa maneira, este trabalho propõe um plano de monitoramento de curta duração para acompanhar o comportamento estrutural de uma ponte rodoviária curva de concreto armado já em serviço. Uma ponte situada na divisa SP-MG foi escolhida para a implantação do plano proposto. Uma hierarquia de seis modelos numéricos foi apresentada, a fim de avaliar estruturalmente o comportamento da ponte. Por fim, os dados obtidos no monitoramento foram avaliados e confrontados com os resultados do modelo numérico mais refinado a título de calibração.

monitoramento de curta-duração; SAP2000; Midas FX+; DIANA; modelagem numérica


Comparison and calibration of numerical models from monitoring data of a reinforced concrete highway bridge

R. G. M. de AndradeI; L. M. TrautweinII; T. N. BittencourtIII

IRodolfo Giacomim Mendes de Andrade, Master Student of Polytechnical School of the University of São Paulo, rodolfogma@gmail.com, São Paulo, Brasil

IILeandro Mouta Trautwein, Professor at Structures Department of Civil Engineering, Architecture and Urbanism of State University of Campinas, leandromt@gmail.com, Campus Zeferino Vaz - Av. Albert Einstein, 951 - Campinas-SP - Brasil

IIITúlio Nogueira Bittencourt, Professor Professor at Strutuctural Engineering and Foundations Department of Polytechnical School of University of São Paulo, tulio.bittencourt@poli.usp.br, Av. Prof. Almeida Prado, trav. 2, 271, 05508-900, São Paulo, São Paulo, Brasil

ABSTRACT

The last four decades were important for the Brazilian highway system. Financial investments were made so it could expand and many structural solutions for bridges and viaducts were developed. In parallel, there was a significant raise of pathologies in these structures, due to lack of maintenance procedures. Thus, this paper main purpose is to create a short-term monitoring plan in order to check the structural behavior of a curved highway concrete bridge in current use. A bridge was chosen as a case study. A hierarchy of six numerical models is shown, so it can validate the bridge's structural behaviour. The acquired data from the monitoring was compared with the finest models so a calibration could be made.

Keywords: short-term monitoring, SAP2000, Midas FX+, DIANA, numerical modelling.

RESUMO

As últimas quatro décadas foram importates para o desenvolvimento da malha rodoviária brasileira. O país recebeu incentivos financeiros à sua expansão e diversas soluções estruturais para pontes e viadutos foram criadas. Em paralelo a este desenvolvimento, houve nos últimos anos um crescimento significativo dessas estruturas em estágio avançado de deterioração devido à ausência de programas de manutenção preventiva. Dessa maneira, este trabalho propõe um plano de monitoramento de curta duração para acompanhar o comportamento estrutural de uma ponte rodoviária curva de concreto armado já em serviço. Uma ponte situada na divisa SP-MG foi escolhida para a implantação do plano proposto. Uma hierarquia de seis modelos numéricos foi apresentada, a fim de avaliar estruturalmente o comportamento da ponte. Por fim, os dados obtidos no monitoramento foram avaliados e confrontados com os resultados do modelo numérico mais refinado a título de calibração.

Palavras-chave: monitoramento de curta-duração, SAP2000, Midas FX+, DIANA, modelagem numérica

1. Introduction

The last decades presented a significant growth of bridges and viaducts in Brazil which suffered from early deterioration caused by lack of maintenance programmes. Although Brazil presents regulations that provide procedures for bridges assessment, in most cases those procedures are only taken when the deterioration of the structure reaches a critical state where users are under risk (Oliveira [1]), (Lencioni [2]).

A case study by SINAENCO (National Union of Architecture and Consulting Engineering), titled "Infrastructure of the City: Expiration Date", shows the need for a permanent policy of maintenance and management of structures. Regarding the city of São Paulo, the study shows that more than 240 bridges and viaducts are in a state of deterioration, offering risk to users. One of the main reasons for the deterioration is given to the low investment, which corresponds to less than 0.38% of the construction budget (SINAENCO [3]).

On the other hand, some initiatives concerning the behaviour of the structure can be found. The cable-stayed bridge over Pinheiros river, where runs a station on Line 5 of the underground system in the city, was monitored for temperature, strain and acceleration during its constructive phase until operation. Also, due to the complexity of the structural solution adopted by the construction method for Bernard Goldfarb bridge located in Pinheiros, São Paulo, it was monitored for deformation not only during construction but in subsequent years. The newly-built cable-stayed bridge João Alves, located in Aracaju-SE, is an example of a particular bridge that is being continuously monitored (ASSIS [4]).

Thus, this paper aims to propose a monitoring plan for a curved reinforced concrete road bridge already in service. A bridge located on the border between the states of São Paulo and Minas Gerais was chosen as a case study to implement the proposed plan. To evaluate the structural behaviour of the bridge, a hierarchy of six numerical models will be done. Finally, it is intended o evaluate the acquired data and compare them with the results of the numerical model.

2. The bridge

The bridge over Jaguari river is a reinforced concrete bridge built in 1999, located in Fernão Dias highway (BR 381), km 946 +300, on the border between the states of São Paulo and Minas Gerais. Figure 1 shows a view in where it is possible to observe part of the structure.


The bridge consists of five spans (20m, 26m, 30m, 26m and 20m) supported on six pairs of columns. Its superstructure is continuous, without joints, presenting a reinforced concrete transition slab on each ends.

The longitudinal axis of the bridge has a 5.9% slope towards Belo Horizonte - São Paulo, also presents constant superelevation of 8% and radius of curvature 305.50 m. Due to the superelevation, the two girders (GB - greater radius and GA and - smaller radius) and the pairs of columns present a 50cm depth offset. The loading is transferred from the superstructure to the columns by rubber bearing supports .

The superstructure has an overall width of 11.70 m, in which 10.90 m is divided into two carriageways, and 0.40 m is for each reinforced concrete New Jersey barriers. The bridge has a π shape cross-section, with main girders 6.40 m (center to center) apart, with an individual cross-section of 40cm wide and depth of 2.80 m. Monolithically connected to the girders, the slab presents variable thickness, being 15 cm at the end of the 2.65m long cantilever and 24 cm at the center. Besides the curvature in plan and longitudinal slope, the girders have prismatic variation of the cross section as they approach the support columns.

The structure consists of 20 transverse beams connected to the bottom of the main girders, spacing from 6.00m to 6.70m. The transverse beams over the columns consist of a cross-section of 25 x 220 cm, while the remaining ones consist of 20 x 220 cm.

The columns have circular section (diameter of 120 cm), being each pair connected by beams (cross section 30 x 80 cm).

The bridge's infrastructure consists of reinforced concrete caissons (diameter of 140 cm).

3. Hierarchy of numerical models

One of the most common questions related to numerical modeling concern the accuracy and quality of results. The data to be inserted while designing model (its geometry, material properties, loads and boundary conditions) are extremely important in order to create a representation of the structure in which it is possible to obtain their structural behaviour (deformation, stress, strain, etc.).

The essence of hierarchical modeling lies on the creation of additional models (and more refined one) of the chosen structure. Aligned with to the refinement, mathematical equations represent that the more complex the model is, the harder it will be the solution to converge. Thus, when changing to a more refined, new hypotheses to the problem are raised so to reach the final model, to be considered satisfactory in terms of accuracy and results (Bucalem [5)].

Thus, the physical problem under study is a curved reinforced concrete bridge under traffic loads and permanent loads. The possible numerical models are shown in Figure 2.


The bridge structural analysis over Jaguari river was performed using numerical models based on the Finite Element Method. Five linear elastic models were studied and developed, and also a nonlinear model, all using softwares SAP2000 ® V14 (models 1 to 4) and Midas Fx + for DIANA ® (models 5 and 6). Such models, illustrated in Figure 3, will be analysed in order to validate the results among them.


3.1 Model 1

Model 1 has the advantages for being simple, agile in the creation and data processing and information in simpler terms of internal forces. For the whole structure 3-D frame elements were used.

The cross-section of the superstructure was represented as a single bar along the whole bridge. Regarding the variation of linear prismatic cross section of girders, three cross sections were created to represent the entire superstructure.

In this model, the entire cross section remains rigid, but with freedom for translations and rotations. As the superstructure behaves like a beam element, the transverse beams were only considered as dead loading. For the creation of the cross section, the superstructure superelevation of 8% was taken into account, as well as the radius of curvature.

3.2 Model 2

Model 2 presents the same geometric and material properties criteria adopted for model 1, except for the replacement of the superstructure from the single bar element for two T-shaped girders. Both girders are connected by the 20 transverse beams.

3.2 Model 3

While Model 2 presents the full flange width of the T-shaped section, Model 3 shows the same properties and geometric criteria adopted in modeling, differing by a reduced flange width according to NBR 6118:2007 (ABNT, [6]).

3.4 Model 4

This model is an enhanced version of the models described above and uses area elements. However, the columns remain as 3-D frames. This model allows new considerations to be made, such as the distribution of the loading on the surface; relative displacement between girders; geometric modeling of transverse beams; transverse bending of the slab (in relation to the girders). Concrete properties and the whole structure geometry used to create Model 1 were maintained.

3.5 Model 5

After using area elements in hierarchical model 4, volumetric elements were used for the development of Model 5 (linear-elastic behaviour). So far, Model 5 is considered the most complete of the five described models.

Designed in MIDAS + Fx software, its geometry was developed from the insertion of individual points created in Excel spreadsheets. The software automatically generated the volume elements, from the insertion of points, drawn lines and areas created manually for it. Tests were made in order to gain accuracy and a 15cm-sided volume element was chosen.

For this model, the whole structure was modeled into volume elements.

3.6 Model 6

Model 6 has the same geometric description considered in Model 5, differing by the non-linear behaviour of volume elements of superstructure and by inserting concentrations of rebar incorporated into the concrete mesh (embedded reinforcement).

Figure 4 illustrates all rebar concentrations inserted in the numerical model; each concentration was placed in the center of gravity of the represented set. In order to satisfactorily represent concrete's non-linearity effects of and cracks' propagation along the sections all rebars were strictly included according to the design project.


3.7 Materials properties

The material properties for the input data in the numerical models were linear-elastic behaviour (models 1 to 5) and non-linear physical behaviour (Model 6).

The main property so the model can behave elastically is the Elastic Modulus, E, which depends from the concrete's characteristic strength, fck. The adopted equation for E was taken from the Brazilian Standard NBR 6118:2007 [6], shown in Table 1.

The input data for properties and equations for the simulations of concrete cracking in DIANA are presented in Table 1 (Trautwein [7]), (Schereppers [8]). It is also presented the equation of the concrete's energy of fracture (CEB, [9]). This energy equation is a function of concrete's fck and maximum aggregate diameter. It can be found in DIANA's library the constitutive model of concrete's tensile softening, presented in five different curves. For this paper, Curve number 5 was adopted, as shown in Figure 5 (Trautwein [7]).


3.8 Boundary conditions

To calculate the stiffness of rubber bearing support, which connects the superstructure with the columns, it was considered the transverse elastic modulus as G = 1.0 MPa, Poisson's Coefficient ν = 0.5, and durometer Shore A 60. The stiffness coefficients obtained for the spring models 1 to 4 are listed in Table 2 (Braga [10]).

Volume elements for the bearing support were used in models 5 and 6. For both models, a fictitious elastic modulus was adopted (Braga [10]), as shown in equation 1 below:

The boundary condition for columns support to the ground on all six models is restriction to the six degrees of freedom - 3 DOF on translation and 3 DOF on rotation.

3.9 Loadings

In all loading cases, it was considered the structure's self-weight. For models 1 to 4, the traffic loading was used according to NBR 6118:2007 (ABNT, [11]) and for models 5 and 6, a real truck loading was used (truck loaded with gravel). The dimensions and loadings are shown in Figure 6. For the six models, the traffic loading was inserted as nodal static loading.


4. Monitoring plan

For monitoring the bridge over Jaguari river the following magnitudes were taken into account: deformation, acceleration and displacement.

From the results of Models 1 to 5, five critical regions were detected and hence monitored (Figure 7): S1 and S3, in the center of spans of 30m and 26m, respectively, S2 and S4, regions right above columns P4 and P5. Sections S1 and S3 presented sagging bending moment and maximum displacements, whereas S2 and S4, high tensile stresses due to hogging bending moment. Thus, it was found that the static vertical displacement of both girders should be measured by displacement transducers. Still, longitudinal and transverse displacements were monitored by displacement sensors inserted on the bearing support over columns P4 and P6. Finally, displacement transducers were used to monitor cracks on the outside face of the girders.


Three accelerometers were installed in regions corresponding to one of the first vibration modes obtained from Model 4: Sections S1 and S3.

This paper approaches the results for displacements only. The dynamic results and deformations are related to other studies from monitoring group.

5. Analyses and results

In order to compare the acquired data during bridge monitoring with numerical models 5 and 6, a previous validation among models 1 to 5 was carried out.

For convenience, Model 4 was considered master model and was compared with models 1 to 3. After the comparison among the first four models, the results regarding vertical displacement was considered satisfactory [12], enabling the next step which consisted in validating Model 5. All the vertical displacement comparisons shown in Table 3 were reliable so the final model could be developed: Model 6.

It is noticed an error decrease as it moves to the center of the bigger span. Due to lack of transverse distribution of loading, a discrepancy between models 1 to 3 and model 4 was expected. Thus, among the different representations of the structure, the Model 4 was considered to be satisfactory compared with the next model, due to a better representation of the bridge structural behavior of the bridge before the first three models.

Model 5 shows a greater stiffness compared to Model 4, which resulted in differences in deflection up to 11%. A higher stiffness was expected due to the stress distribution within the volume and an increased contribution of the compressed girder flanges. While modeling Model 5, the prismatic variation of girder width was possible to be properly done. Thus, Model 5 satisfactorily represents the structural behaviour and was used as a basis for generating the model 6.

Next, a comparison of the results obtained during monitoring process will be made, illustrated in Figure 8, with models 5 and 6.


Model 5 required about 10 hours of processing (Intel (R) Core (TM) i7 CPU 960@3.20GHz, 16BG RAM) for each load case. Shown in Table 4, the results for the girder at the bigger span were 17.37% lower than that shown in data acquisition, i.e. it presented a higher stiffness than the actual structure. The results for girders A and B at 26m span were, respectively, 10.32% and 5.39% less than the vertical displacement acquired in monitoring. A suggested fck of 25 MPa was used as a calibration and convergence response. A reduction of 3.57% in the Elastic Modulus resulted in an error decrease of 3.40%.

Model 6 required approximately 120 hours of processing for loadcases located at 30m span, while approximately 40 hours were required for the loadcases on 26m span. According to Table 5 for the Elastic Modulus obtained in laboratory, Model 6 showed an error of 21.52% in the girder B, at 30m span, while girders A and B, at 26m span, were respectively 21.37% and 15.71%. For this model, the calibration was only at energy of fracture. A decrease of 16.69% in its value led to a vertical displacement reduction of only to 0.73% at 30m span, while other spans presented no change in displacement. With the decrease of span length, the energy of fracture had little influence in changing the results.

6. Conclusions

The refinement of numerical modeling through hierarchy is important so the model behaviour and representativeness can increase and improve. By increasing the number of degrees of freedom of the numerical model and adding new inherent parameters to the structure, each step on hierarchy level must provide means of interpretation the results and model calibration, so there is convergence with experimental results. It is also important to emphasize a deep understanding of each new inserted parameter. The more complex the model is, the more likely the response will diverge, compromising the validation of results.

7. Aknowledgements

The authors would like to thank OHL Concession Company for all logistical support during bridge monitoring over Jaguari river.

8. Bibliography

Received: 11 Jun 2012

Accepted: 14 Sep 2012

Available Online: 08 Feb 2013

References

  • [01] OLIVEIRA M.Q. et al.. Verificação de Deterioração em Pontes de Concreto: Estudo de Caso de uma ponte sobre o rio Piauí.. Congresso Brasileiro do Concreto, 51ş, Curitiba, 2009, Anais, Paraná, 2009.
  • [02] LENCIONI, J.W., LIMA, M.G. Análise da Importância da Consideração de Fatores Ambientais na Degradação de Obras de Arte. Congresso Brasileiro do Concreto, 46ş, Florianópolis, 2004, Anais, Santa Catarina, 2004.
  • [03] SINDICATO DA ARQUITETURA E DA ENGENHARIA. Infra-Estrutura da Cidade de São Paulo: Prazo de Validade Vencido, São Paulo, 2007.
  • [04] ASSIS, W.S., Sistemas Computacionais de Apoio à Monitoração de Estruturas de Engenharia Civil, São Paulo, 2007, Tese (doutorado) - Escola Politécnica da Universidade de São Paulo.
  • [05] BUCALEM, M.L., BATHE, K.J., The Mechanics of Solids and Structures - Hierarchical Modeling and the Finite Element Solution, Cambridge, 2011.
  • [06] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. Projeto de Estruturtas de Concreto - Procedimento - NBR 6118, Rio de Janeiro, 2007.
  • [07] TRAUTWEIN, L.M., Punção em Lajes Cogumelo de Concreto Armado: Análise Experimental e Numérica, São Paulo, 2006, Tese (doutorado) - Escola Politécnica da Universidade de São Paulo.
  • [08] SCHREPPERS, G.J., FRISSEN, C., KANG, H.J., Prediction of Crack-Width and Crack-Pattern. TNO DIANA BV, Netherlands, 2011.
  • [09] COMITE EURO-INTERNATIONAL DU BETON, CEB-FIP Modelo Code 1990 - Design Code, Lausanne, 1991.
  • [10] BRAGA, W.A. Aparelhos de Apoio das Estruturas, São Paulo, 1986.
  • [11] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. Carga Móvel em Ponte Rodoviária e Passarela de Pedestre - NBR 7188, Rio de Janeiro, 1984.
  • [12] ANDRADE, R.G.M., TEIXEIRA, R.M., MENEGHETTI, L.C., BITTENCOURT, T.N., Aplicação de Hierarquia de Modelos Numéricos para uma Ponte Curva em Concreto Armado. Congresso Brasileiro do Concreto, 53ş, Florianópolis, 2011, Anais, Santa Catarina, 2011.

Publication Dates

  • Publication in this collection
    28 Feb 2013
  • Date of issue
    Feb 2013

History

  • Received
    11 June 2012
  • Accepted
    14 Sept 2012
location_on
IBRACON - Instituto Brasileiro do Concreto Instituto Brasileiro do Concreto (IBRACON), Av. Queiroz Filho, nº 1700 sala 407/408 Torre D, Villa Lobos Office Park, CEP 05319-000, São Paulo, SP - Brasil, Tel. (55 11) 3735-0202, Fax: (55 11) 3733-2190 - São Paulo - SP - Brazil
E-mail: arlene@ibracon.org.br
rss_feed Acompanhe os números deste periódico no seu leitor de RSS
Acessibilidade / Reportar erro