Abstract
Objective
The present study aims to evaluate the screw length and trajectory angles for posterior atlantoaxial fixation in a Portuguese population, through the study of cervical computed tomography (CT) scans.
Methods
Cervical CT scans of 50 adults were measured according to predefined screw trajectories of C1-C2 transarticular (C1C2TA), C1 lateral mass (C1LM), C2 pedicle (C2P), C2 pars and C2 laminar (C2L) screws. For each of these trajectories, screw length and angles were measured and compared between males and females.
Results
For the C1C2TA screw trajectory, the mean length, medial, and cranial angles were 34.12 ± 3.19 mm, 6.24° ± 3.06, and 59.25° ± 5.68, respectively, and for the C1LM screw trajectory, they were 27.12 ± 2.15 mm, 15.82° ± 5.07, and 13.53° ± 4.80, respectively. The mean length, medial, and cranial angles for the C2P screw trajectory were 23.44 ± 2.49 mm, 27.40° ± 4.88, and 30.41° ± 7.27, respectively; and for the C2 pars screw trajectory, they were 16.84 ± 2.08 mm, 20.09° ± 6.83, and 47.53° ± 6,97. The mean length, lateral, and cranial angles for the C2L screw trajectory were 29.10 ± 2.48 mm, 49.80° ± 4.71, and 21.56° ± 7.76, respectively. There were no gender differences except for the lengths of the C1C2TA (p= 0,020) and C2L (p= 0,001) screws, which were greater in males than in females.
Conclusion
The present study provides anatomical references for the posterior atlantoaxial fixation in a Portuguese population. These detailed data are essential to aid spine surgeons to achieve safe and effective screw placement.
Keywords
atlantoaxial joint; bone screws; cervical vertebrae; joint instability; surgical fixation devices
Resumo
Objetivo
O presente estudo tem como objetivo avaliar o comprimento e os ângulos de trajetória do parafuso para fixação atlantoaxial posterior em uma população portuguesa por meio do estudo de tomografia computadorizada (TC) cervical.
Métodos
Tomografias computadorizadas cervicais de 50 adultos foram analisadas quanto às trajetórias pré-definidas dos parafusos transarticulares C1-C2 (C1C2TA), na massa lateral de C1 (C1LM), no pedículo de C2 (C2P) e na pars de C2 e C2 laminar (C2L). O comprimento e os ângulos dos parafusos em cada uma destas trajetórias foram medidos e comparados entre homens e mulheres.
Resultados
O comprimento médio e ângulos medial e cranial da trajetória do parafuso C1C2TA foram de 34,12 ± 3,19 mm, 6,24° ± 3,06 e 59,25° ± 5,68, respectivamente; as medidas da trajetória do parafuso C1LM foram 27,12 ± 2,15 mm, 15,82° ± 5,07 e 13,53° ± 4,80. O comprimento médio e os ângulos medial e cranial da trajetória do parafuso C2P foram de 23,44 ± 2,49 mm, 27,40° ± 4,88 e 30,41° ± 7,27, respectivamente; as medidas da trajetória do parafuso da pars de C2 foram 16,84 ± 2,08 mm, 20,09° ± 6,83 e 47,53° ± 6,97. O comprimento médio e ângulos lateral e cranial da trajetória do parafuso C2L foram de 29,10 ± 2,48 mm, 49,80° ± 4,71 e 21,56° ± 7,76, respectivamente. Não houve diferenças entre os gêneros, à exceção do comprimento dos parafusos C1C2TA (p= 0,020) e C2L (p= 0,001), que foi maior no sexo masculino do que no feminino.
Conclusão
O presente estudo fornece referências anatômicas para a fixação atlantoaxial posterior em uma população portuguesa. Estes dados detalhados são essenciais para ajudar os cirurgiões de coluna a colocar os parafusos de maneira segura e eficaz.
Palavras-chave
articulação atlantoaxial; parafusos ósseos; vértebra cervical; instabilidade articular; dispositivos de fixação cirúrgica
Introduction
The atlantoaxial (C1-C2) joint has a close relationship with several vascular and neural structures, such as the vertebral artery (VA), atlas (C1) and axis (C2) nerve roots, and the vertebral venous plexus.11 Lopez AJ, Scheer JK, Leibl KE, Smith ZA, Dlouhy BJ, Dahdaleh NS. Anatomy and biomechanics of the craniovertebral junction. Neurosurg Focus 2015;38(04):E2
The C1-C2 complex contributes with 50% of the cervical spine rotation capacity and is formed by the atlanto-odontoid joint and the lateral atlantoaxial joints. These joints, together with the cruciform, the alar, and the apical ligaments are responsible for the stability of the atlantoaxial complex. Without this ligament stability, spinal cord compression may occur, which can lead to tetraparesis or even sudden death.22 Yang SY, Boniello AJ, Poorman CE, Chang AL, Wang S, Passias PG. A review of the diagnosis and treatment of atlantoaxial dislocations. Global Spine J 2014;4(03):197-210
Trauma, congenital malformations, neoplasms, infections, and inflammatory diseases, such as rheumatoid arthritis33 Gautschi OP, Payer M, Corniola MV, Smoll NR, Schaller K, Tessitore E. Clinically relevant complications related to posterior atlantoaxial fixation in atlanto-axial instability and their management. Clin Neurol Neurosurg 2014;123:131-135 and ankylosing spondylitis,44 Lyons C, Ross M, Elliott R, Tall M. Atlantoaxial instability in a patient with neck pain and ankylosing spondylitis. Mil Med 2018; 183(9-10):e654-e657 have been implicated in the development of C1-C2 instability.33 Gautschi OP, Payer M, Corniola MV, Smoll NR, Schaller K, Tessitore E. Clinically relevant complications related to posterior atlantoaxial fixation in atlanto-axial instability and their management. Clin Neurol Neurosurg 2014;123:131-135 Even though conservative management can be appropriate for some patients, surgical intervention is often necessary.22 Yang SY, Boniello AJ, Poorman CE, Chang AL, Wang S, Passias PG. A review of the diagnosis and treatment of atlantoaxial dislocations. Global Spine J 2014;4(03):197-210
Several posterior atlantoaxial fixation techniques were utilized until the development of the screw-rod technique widely used today.55 Chen Q, Brahimaj BC, Khanna R, et al. Posterior atlantoaxial fusion: a comprehensive review of surgical techniques and relevant vascular anomalies. J Spine Surg 2020;6(01):164-180 However, due to the anatomical proximity to neurovascular structures, posterior atlantoaxial fixation with screws is associated with potentially serious complications, depending on the choice of the surgical technique. The complications that may occur include vascular and neurological injuries, bony nonunion, screw breakage, and surgical site infection.33 Gautschi OP, Payer M, Corniola MV, Smoll NR, Schaller K, Tessitore E. Clinically relevant complications related to posterior atlantoaxial fixation in atlanto-axial instability and their management. Clin Neurol Neurosurg 2014;123:131-135
Therefore, spine surgeons must be familiar with the different posterior atlantoaxial fusion techniques, along with in-depth anatomical knowledge, to minimize the complications inherent to the surgery.
The goal of the present study was to assess the length and trajectory angles for posterior atlantoaxial screw placement in a Portuguese population, through the study of cervical computed tomography (CT) scans performed at the Centro Hospitalar Universitário do Porto, Porto, Portugal.
Methods
The present single-center retrospective study included all patients in the SECTRA IDS7 (version 17.3.2086) database who underwent a cervical CT scan from October 10, 2020 to January 11, 2021 and was approved by the local ethics committee (REF. 2021.042(035-DEFI/036-CE)).
A total of 217 clinical files were analyzed and 167 were excluded for having incomplete CT scans, cervical fractures, bone neoplasms, cervical degenerative diseases including disc herniation, presence of osteophytes and spondylolisthesis, cervical scoliosis, history of cervical surgery, and inflammatory diseases such as rheumatoid arthritis and ankylosing spondylitis. The remaining 50 CT scans were analyzed using Surgimap version 2.3.2.1 (Nemaris Inc., New York, NY, USA).
The measurements were performed based on predefined screw trajectories of C1-C2 transarticular (C1C2TA), C1 lateral mass (C1LM), C2 pedicle (C2P), C2 pars, and C2 laminar (C2L) screws. All screw measurements were made by two investigators to reduce bias.
The screw length, medial, lateral, and cranial angles were measured on the right side of C1 and C2 vertebrae. All screws were placed unicortically with the maximum length allowed without crossing the anterior cortex of the vertebrae and it was ensured that the bone height and width could safely accommodate a 3.5-mm diameter screw.
The medial and lateral angles, in the axial plane, were obtained by measuring the angle formed by the intersection of the predefined screw trajectory and the longitudinal midline of the respective vertebra. In the sagittal plane, the cranial angle for the C1LM screw trajectory was the angle between the endplate of C1 and the screw trajectory line. For the C1C2TA, C2P, C2 pars, and C2L screw trajectories, the cranial angle was the angle made by the screw trajectory line and the line parallel to the C2 inferior vertebral body border.
C1-C2 Transarticular Screw
The starting point used for the C1C2TA screw trajectory was 3 mm lateral and 3 mm superior to the medial border of the C2-C3 facet joint. The trajectory was directed medially in the axial plane and toward the C1 anterior arch in the sagittal plane (►Fig. 1).66 Jeanneret B, Magerl F. Primary posterior fusion C1/2 in odontoid fractures: indications, technique, and results of transarticular screw fixation. J Spinal Disord 1992;5(04):464-475
C1C2TA screw trajectory measurement. C1C2TA screw in the axial plane (A) and in the sagittal plane (B).
C1 Lateral Mass Screw
For the C1LM screw trajectory, the starting point used was at the intersection of the lower edge of the C1 posterior arch with the midpoint of the C1 lateral mass. The trajectory was convergent toward the C1 anterior arch and parallel to the C1 posterior arch in the sagittal plane (►Fig. 2).77 Harms J, Melcher RP. Posterior C1-C2 fusion with polyaxial screw and rod fixation. Spine (Phila Pa 1976) 2001;26(22):2467-2471
C1LM screw trajectory measurement. C1LM screw in the axial plane (A) and in the sagittal plane (B).
C2 Pedicle Screw
For the C2P screw trajectory, the starting point used was the midpoint between the superior and inferior C2 articular processes. The trajectory was directed medially and cranially to the C2 anterior cortex (►Fig. 3).88 Huang D-G, Hao D-J, He B-R, et al. Posterior atlantoaxial fixation: a review of all techniques. Spine J 2015;15(10):2271-2281
C2P screw trajectory measurement. C2P screw in the axial plane (A) and in the sagittal plane (B).
C2 Pars Screw
The starting point used for C2 pars screw trajectory was 3 mm lateral and 3 mm superior to the medial border of the C2-C3 facet joint. The trajectory was directed medially and cranially, parallel to the C2 pars in the sagittal plane and parallel to the medial border of the pars in the axial plane (►Fig. 4).88 Huang D-G, Hao D-J, He B-R, et al. Posterior atlantoaxial fixation: a review of all techniques. Spine J 2015;15(10):2271-2281
C2 pars screw trajectory measurement. C2 pars screw in the axial plane (A) and in the sagittal plane (B).
C2 Laminar Screw
For the C2LS trajectory, the starting point used was at the junction of the C2 spinous process and the lamina, with the screw trajectory being directed parallel to the downslope of the contralateral lamina (►Fig. 5).99 Wright NM. Posterior C2 fixation using bilateral, crossing C2 laminar screws: case series and technical note. J Spinal Disord Tech 2004;17(02):158-162
C2L screw trajectory measurement. C2L screw in the axial plane (A) and in the sagittal plane (B).
Statistical Analysis
An interobserver reliability analysis using Cohen Kappa statistic was performed to determine the agreement between investigators.
Additionally, descriptive statistics were calculated. To identify statistically significant differences between gender, a statistical analysis of the data was performed using a t-test for independent samples, considering a p-value < 0.05 as significant.
Data were analyzed using the statistical software IBM SPSS Statistics for Windows, version 26.0 (IBM Corp., Armonk, NY, USA).
Results
The age of the sample by gender is shown in ►Table 1. There was good interobserver agreement (K > 0.4) for all measurements except for the C1LM screw length (►Table 2). The mean length and angles for each screw trajectory are shown in ►Table 3. The comparison of screw measurements by gender (►Table 4) demonstrated that the mean screw length in males was higher for the C1C2TA and C2L screw trajectories. There were no significant statistical differences between genders for the C1LM, C2P, and C2 pars screws length (p> 0.05). Also, there were no gender significant statistical differences for any trajectory angles.
Discussion
Posterior atlantoaxial fixation is required to provide stability, reduce deformity, and prevent neurological injury. Currently, the more commonly used techniques for posterior atlantoaxial arthrodesis are C1C2TA screws and screw-rod fixations, which include a C1LM screw combined with C2P, C2 pars, or C2L screws.1010 Liu S, Song Z, Liu L, et al. Biomechanical evaluation of C1 lateral mass and C2 translaminar bicortical screws in atlantoaxial fixation: an in vitro human cadaveric study. Spine J 2018;18(04): 674-681 These procedures achieve a high fusion rate and an immediate rigid fixation, eliminating the need for a postoperative external orthosis.1111 Sugawara T, Higashiyama N, Kaneyama S, Sumi M. Accurate and Simple Screw Insertion Procedure With Patient-Specific Screw Guide Templates for Posterior C1-C2 Fixation. Spine (Phila Pa 1976) 2017;42(06):E340-E346
The screw constructs are selected based on the osseous and vascular C1-C2 anatomy of the patient, the particular pathological lesion, and the experience and comfort level of the surgeon.1212 Du JY, Aichmair A, Kueper J, Wright T, Lebl DR. Biomechanical analysis of screw constructs for atlantoaxial fixation in cadavers: a systematic review and meta-analysis. J Neurosurg Spine 2015; 22(02):151-161 Due to the variable anatomy of the C1-C2 complex, a preoperative cervical CT scan or magnetic resonance imaging (MRI) is highly recommended to determine the anatomic feasibility and safe screw trajectory to avoid complications related to the placement of the screw.55 Chen Q, Brahimaj BC, Khanna R, et al. Posterior atlantoaxial fusion: a comprehensive review of surgical techniques and relevant vascular anomalies. J Spine Surg 2020;6(01):164-180
Several authors have described the most used screw trajectories for posterior atlantoaxial fixation; however, there is a lack of studies analyzing all these screw trajectories in the same population. Besides, there are no reports of anatomical references for these screws in the Portuguese population. Hence, the present study is essential to provide anatomical references, adding to existing knowledge. The comparison between the results in the present study and the international literature for each screw trajectory is shown in ►Table 5.
Comparison between the screw measurements of the present study and those described in the international literature
Transarticular screw fixation, introduced by Magerl, provides high stability and fusion rates ranging from 92% to 100%.55 Chen Q, Brahimaj BC, Khanna R, et al. Posterior atlantoaxial fusion: a comprehensive review of surgical techniques and relevant vascular anomalies. J Spine Surg 2020;6(01):164-180 However, this technique requires reduction of the C1-C2 complex before screw placement and is associated with a potential risk of injury to the vertebral artery, particularly in those with a high-riding VA.1313 Rajinda P, Towiwat S, Chirappapha P. Comparison of outcomes after atlantoaxial fusion with C1 lateral mass-C2 pedicle screws and C1-C2 transarticular screws. Eur Spine J 2017;26(04): 1064-1072
Nogueira-Barbosa et al.1414 Nogueira-Barbosa MH, Defino HL. Multiplanar reconstructions of helical computed tomography in planning of atlanto-axial transarticular fixation. Eur Spine J 2005;14(05):493-500 analyzed 100 CT scans to determine atlantoaxial bone morphometric measurements related to the transarticular screw fixation technique. Their study determined that, in males, the screw length was 39 mm, the medial angle was 8°, and the cranial angle was 59°. In females, the screw length and the medial and cranial angles were 37 mm, 7° and 57°, respectively. In the present study, the results were similar.
To overcome the pitfalls of the transarticular fixation technique, Harms and Melcher introduced a C1-C2 fixation technique using a C1LM screw combined with C2P or C2 pars screws. This technique has good biomechanical strength and allows intraoperative reduction of the atlantoaxial complex.1515 Lu X, Xu T. Advantages and Disadvantages of Traditional Atlantoaxial Fusion Techniques. In: Ni B, Guo X, Guo Q, eds. Atlantoaxial Fixation Techniques. Translational Medicine Research. Singapore: Springer; 2018:39-48 Additionally, the trajectories of the C2P and C2 pars screws are more medial than that of the C1C2TA screw, thus reducing the risk of VA injury.1616 Sim HB, Lee JW, Park JT, Mindea SA, Lim J, Park J. Biomechanical evaluations of various c1-c2 posterior fixation techniques. Spine (Phila Pa 1976) 2011;36(06):E401-E407 Despite these advantages, the risk of VA or neurological lesion still exists.1313 Rajinda P, Towiwat S, Chirappapha P. Comparison of outcomes after atlantoaxial fusion with C1 lateral mass-C2 pedicle screws and C1-C2 transarticular screws. Eur Spine J 2017;26(04): 1064-1072
Medial angulation of the C1LM screw maximizes the margin of safety, with any lateral angulation being unsafe, risking violation of the vertebral foramen and VA injury.1717 Blagg SE, Don AS, Robertson PA. Anatomic determination of optimal entry point and direction for C1 lateral mass screw placement. J Spinal Disord Tech 2009;22(04):233-239 The placement of the C1LM screw may also cause postoperative C2 nerve injury and massive bleeding from the venous plexus below the C1 posterior arch during exposure of the C1LM screw entry point.88 Huang D-G, Hao D-J, He B-R, et al. Posterior atlantoaxial fixation: a review of all techniques. Spine J 2015;15(10):2271-2281
Different C1LM screw lengths and angles have been described in earlier anatomic studies, depending on the selected screw entry point and on the anatomy of each patient.77 Harms J, Melcher RP. Posterior C1-C2 fusion with polyaxial screw and rod fixation. Spine (Phila Pa 1976) 2001;26(22):2467-2471,1818 Simsek S, Yigitkanli K, Seçkin H, et al. Ideal screw entry point and projection angles for posterior lateral mass fixation of the atlas: an anatomical study. Eur Spine J 2009;18(09):1321-1325
19 Christensen DM, Eastlack RK, Lynch JJ, Yaszemski MJ, Currier BL. C1 anatomy and dimensions relative to lateral mass screw placement. Spine (Phila Pa 1976) 2007;32(08):844-848
20 Rocha R, Safavi-Abbasi S, Reis C, et al. Working area, safety zones, and angles of approach for posterior C-1 lateral mass screw placement: a quantitative anatomical and morphometric evaluation. J Neurosurg Spine 2007;6(03):247-254-2121 Hu Y, Dong WX, Spiker WR, et al. An anatomic study to determine the optimal entry point, medial angles, and effective length for safe fixation using posterior C1 lateral mass screws. Spine (Phila Pa 1976) 2015;40(04):E191-E198 Also, there is evidence that the trajectory angles have implications on screw lengths. Hu Y et al. conducted a study to determine the optimal entry point, medial angle, and effective length for safe fixation of C1LM screws and concluded that a greater medial angle implies a longer screw length. In their study, it was considered that the optimal entry point was at the middle of the posterior C1 inferior articular process 2 mm above the articular surface. Regarding angles, they used a fixed 15° cephalad angle and determined that the optimal medial angle to reduce the risk of VA and spinal cord injury was 21° with a corresponding screw length of 22 mm inside the C1LM.2121 Hu Y, Dong WX, Spiker WR, et al. An anatomic study to determine the optimal entry point, medial angles, and effective length for safe fixation using posterior C1 lateral mass screws. Spine (Phila Pa 1976) 2015;40(04):E191-E198 Simsek et al.1818 Simsek S, Yigitkanli K, Seçkin H, et al. Ideal screw entry point and projection angles for posterior lateral mass fixation of the atlas: an anatomical study. Eur Spine J 2009;18(09):1321-1325 found that the ideal screw cranial angle was 15° using the same entry point as the present study. The screw length inside the lateral mass and the medial angle, measured on the right side of the C1 vertebra, were 20 mm and 14°, respectively. However, due to the overlying C1 posterior arch, the screw length increases to allow the placement of the rod in the polyaxial head of the screw. Rocha et al.2020 Rocha R, Safavi-Abbasi S, Reis C, et al. Working area, safety zones, and angles of approach for posterior C-1 lateral mass screw placement: a quantitative anatomical and morphometric evaluation. J Neurosurg Spine 2007;6(03):247-254 determined the ideal screw length with the overlying C1 posterior arch as 30 mm with screws placed bicortically. Regarding angulation, the medial and cranial angles were 17° and 22°, respectively.2020 Rocha R, Safavi-Abbasi S, Reis C, et al. Working area, safety zones, and angles of approach for posterior C-1 lateral mass screw placement: a quantitative anatomical and morphometric evaluation. J Neurosurg Spine 2007;6(03):247-254 In the present study, the C1LM screw length inside and outside the C1LM was 27 mm with 16° medial and 14° cranial angles.
The C2P screw technique has the advantage over the C1C2TA screw of requiring a less acute approach angle.1616 Sim HB, Lee JW, Park JT, Mindea SA, Lim J, Park J. Biomechanical evaluations of various c1-c2 posterior fixation techniques. Spine (Phila Pa 1976) 2011;36(06):E401-E407 However, the C2 pedicle width and height limit the placement of the screw.2222 Meyer D, Meyer F, Kretschmer T, Börm W. Translaminar screws of the axis - an alternative technique for rigid screw fixation in upper cervical spine instability. Neurosurg Rev 2012;35(02):255-261
Some studies claim that the C2P screw provides the highest biomechanical stability when compared with C2 pars and C2L screws.2323 Chun DH, Yoon DH, Kim KN, Yi S, Shin DA, Ha Y. Biomechanical Comparison of Four Different Atlantoaxial Posterior Fixation Constructs in Adults: A Finite Element Study. Spine (Phila Pa 1976) 2018;43(15):E891-E897
24 Sai Kiran NA, Sivaraju L, Vidyasagar K, et al. Safety and Accuracy of Anatomic and Lateral Fluoroscopic-Guided Placement of C2 Pars/ Pedicle Screws and C1 Lateral Mass Screws, and Freehand Placement of C2 Laminar Screws. World Neurosurg 2018;118: e304-e315-2525 Lehman RA Jr, Dmitriev AE, Helgeson MD, Sasso RC, Kuklo TR, Riew KD. Salvage of C2 pedicle and pars screws using the intralaminar technique: a biomechanical analysis. Spine (Phila Pa 1976) 2008;33(09):960-965 Therefore, the placement of C2 pars or C2L screws is an important alternative when the cervical anatomy of the patient precludes the placement of a C2P screw, such as in C2 pedicle hypoplasia or high-riding VA.1111 Sugawara T, Higashiyama N, Kaneyama S, Sumi M. Accurate and Simple Screw Insertion Procedure With Patient-Specific Screw Guide Templates for Posterior C1-C2 Fixation. Spine (Phila Pa 1976) 2017;42(06):E340-E346,1212 Du JY, Aichmair A, Kueper J, Wright T, Lebl DR. Biomechanical analysis of screw constructs for atlantoaxial fixation in cadavers: a systematic review and meta-analysis. J Neurosurg Spine 2015; 22(02):151-161,2626 Dobran M, Nasi D, Esposito DP, Iacoangeli M. Posterior Fixation with C1 Lateral Mass Screws and C2 Pars Screws for Type II Odontoid Fracture in the Elderly: Long-Term Follow-Up. World Neurosurg 2016;96:152-158
Chin et al.2727 Chin KR, Mills MV, Seale J, Cumming V. Ideal starting point and trajectory for C2 pedicle screw placement: a 3D computed tomography analysis using perioperative measurements. Spine J 2014;14(04):615-618 conducted a similar study using CT scans from 34 patients to evaluate the ideal screw trajectory through each C2 pedicle and concluded that, on the right side, the screw length and the medial and cranial angles were 22 mm, 28° and 23°, respectively. In the current study, the results for C2P screw length and medial angle were similar but with a 30° cranial angle.
Sai Kiran et al.2424 Sai Kiran NA, Sivaraju L, Vidyasagar K, et al. Safety and Accuracy of Anatomic and Lateral Fluoroscopic-Guided Placement of C2 Pars/ Pedicle Screws and C1 Lateral Mass Screws, and Freehand Placement of C2 Laminar Screws. World Neurosurg 2018;118: e304-e315 evaluated the safety and accuracy of anatomic and lateral fluoroscopic-guided placement of C2 pars screws. They determined that screw placement was safe with a 16 mm screw length with a medial and cranial angulation of 23° and 30°, respectively. Although the screw length and the medial angle were similar to those determined by Sai Kiran et al.,2424 Sai Kiran NA, Sivaraju L, Vidyasagar K, et al. Safety and Accuracy of Anatomic and Lateral Fluoroscopic-Guided Placement of C2 Pars/ Pedicle Screws and C1 Lateral Mass Screws, and Freehand Placement of C2 Laminar Screws. World Neurosurg 2018;118: e304-e315 the cranial angle was found to be higher in the present study. This difference may result from using a different reference plane.
The bilateral crossing C2L screw, described by Wright, avoids the risk of VA injury since the screws are not positioned near the transverse foramen.99 Wright NM. Posterior C2 fixation using bilateral, crossing C2 laminar screws: case series and technical note. J Spinal Disord Tech 2004;17(02):158-162 The placement of this screw is safe, easy to perform, and does not require fluoroscopy or spinal navigation. However, C2L screws have an increased risk of spinal canal injury from a ventral cortical breach.1515 Lu X, Xu T. Advantages and Disadvantages of Traditional Atlantoaxial Fusion Techniques. In: Ni B, Guo X, Guo Q, eds. Atlantoaxial Fixation Techniques. Translational Medicine Research. Singapore: Springer; 2018:39-48
Dean et al.2828 Dean CL, Lee MJ, Robbin M, Cassinelli EH. Correlation between computed tomography measurements and direct anatomic measurements of the axis for consideration of C2 laminar screw placement. Spine J 2009;9(03):258-262 conducted a study to evaluate critical dimensions of the C2 vertebrae for laminar screw placement through CT scan measurements and concluded that the C2L screw length was 29 mm and the lateral angle was 42°. In the present study, the screw length was the same as that determined by Dean et al.2828 Dean CL, Lee MJ, Robbin M, Cassinelli EH. Correlation between computed tomography measurements and direct anatomic measurements of the axis for consideration of C2 laminar screw placement. Spine J 2009;9(03):258-262 but with a 50° lateral angle.
To the best of our knowledge, the present study is the first to provide a complete description of the most commonly used screw trajectories for posterior atlantoaxial fixation in the same population. Moreover, it is the first study providing anatomical references for posterior C1-C2 screw placement in a Portuguese population.
Nevertheless, the limitations of the present study should be noted. The screw length and angles were measured only on the right side of the C1 and C2 vertebrae. Additionally, all the measurements were made manually and are investigator-dependent. Therefore, to overcome this limitation, the screw length and angles were measured by two investigators, and a good agreement was obtained for all but one measurement.
Conclusion
Instrumentation in upper cervical spine surgery can lead to catastrophic complications and extreme care must be taken to minimize these events. The present study provides important atlantoaxial references that may help spine surgeons to achieve proper screw placement, especially when intraoperative navigation is not available. However, due to the anatomic variations of the C1-C2 complex, this data can serve only as a rough guide and is not sufficient for safe and effective screw implantation. Therefore, if screw implantation is considered, it is essential to perform preoperative CT imaging with a detailed anatomic analysis to determine the ideal screw trajectory.
-
Financial SupportThe authors have no financial disclosures to declare.
-
Work developed at the Department of Orthopaedics, Centro Hospitalar Universitário do Porto, Porto, Portugal.
References
-
1Lopez AJ, Scheer JK, Leibl KE, Smith ZA, Dlouhy BJ, Dahdaleh NS. Anatomy and biomechanics of the craniovertebral junction. Neurosurg Focus 2015;38(04):E2
-
2Yang SY, Boniello AJ, Poorman CE, Chang AL, Wang S, Passias PG. A review of the diagnosis and treatment of atlantoaxial dislocations. Global Spine J 2014;4(03):197-210
-
3Gautschi OP, Payer M, Corniola MV, Smoll NR, Schaller K, Tessitore E. Clinically relevant complications related to posterior atlantoaxial fixation in atlanto-axial instability and their management. Clin Neurol Neurosurg 2014;123:131-135
-
4Lyons C, Ross M, Elliott R, Tall M. Atlantoaxial instability in a patient with neck pain and ankylosing spondylitis. Mil Med 2018; 183(9-10):e654-e657
-
5Chen Q, Brahimaj BC, Khanna R, et al. Posterior atlantoaxial fusion: a comprehensive review of surgical techniques and relevant vascular anomalies. J Spine Surg 2020;6(01):164-180
-
6Jeanneret B, Magerl F. Primary posterior fusion C1/2 in odontoid fractures: indications, technique, and results of transarticular screw fixation. J Spinal Disord 1992;5(04):464-475
-
7Harms J, Melcher RP. Posterior C1-C2 fusion with polyaxial screw and rod fixation. Spine (Phila Pa 1976) 2001;26(22):2467-2471
-
8Huang D-G, Hao D-J, He B-R, et al. Posterior atlantoaxial fixation: a review of all techniques. Spine J 2015;15(10):2271-2281
-
9Wright NM. Posterior C2 fixation using bilateral, crossing C2 laminar screws: case series and technical note. J Spinal Disord Tech 2004;17(02):158-162
-
10Liu S, Song Z, Liu L, et al. Biomechanical evaluation of C1 lateral mass and C2 translaminar bicortical screws in atlantoaxial fixation: an in vitro human cadaveric study. Spine J 2018;18(04): 674-681
-
11Sugawara T, Higashiyama N, Kaneyama S, Sumi M. Accurate and Simple Screw Insertion Procedure With Patient-Specific Screw Guide Templates for Posterior C1-C2 Fixation. Spine (Phila Pa 1976) 2017;42(06):E340-E346
-
12Du JY, Aichmair A, Kueper J, Wright T, Lebl DR. Biomechanical analysis of screw constructs for atlantoaxial fixation in cadavers: a systematic review and meta-analysis. J Neurosurg Spine 2015; 22(02):151-161
-
13Rajinda P, Towiwat S, Chirappapha P. Comparison of outcomes after atlantoaxial fusion with C1 lateral mass-C2 pedicle screws and C1-C2 transarticular screws. Eur Spine J 2017;26(04): 1064-1072
-
14Nogueira-Barbosa MH, Defino HL. Multiplanar reconstructions of helical computed tomography in planning of atlanto-axial transarticular fixation. Eur Spine J 2005;14(05):493-500
-
15Lu X, Xu T. Advantages and Disadvantages of Traditional Atlantoaxial Fusion Techniques. In: Ni B, Guo X, Guo Q, eds. Atlantoaxial Fixation Techniques. Translational Medicine Research. Singapore: Springer; 2018:39-48
-
16Sim HB, Lee JW, Park JT, Mindea SA, Lim J, Park J. Biomechanical evaluations of various c1-c2 posterior fixation techniques. Spine (Phila Pa 1976) 2011;36(06):E401-E407
-
17Blagg SE, Don AS, Robertson PA. Anatomic determination of optimal entry point and direction for C1 lateral mass screw placement. J Spinal Disord Tech 2009;22(04):233-239
-
18Simsek S, Yigitkanli K, Seçkin H, et al. Ideal screw entry point and projection angles for posterior lateral mass fixation of the atlas: an anatomical study. Eur Spine J 2009;18(09):1321-1325
-
19Christensen DM, Eastlack RK, Lynch JJ, Yaszemski MJ, Currier BL. C1 anatomy and dimensions relative to lateral mass screw placement. Spine (Phila Pa 1976) 2007;32(08):844-848
-
20Rocha R, Safavi-Abbasi S, Reis C, et al. Working area, safety zones, and angles of approach for posterior C-1 lateral mass screw placement: a quantitative anatomical and morphometric evaluation. J Neurosurg Spine 2007;6(03):247-254
-
21Hu Y, Dong WX, Spiker WR, et al. An anatomic study to determine the optimal entry point, medial angles, and effective length for safe fixation using posterior C1 lateral mass screws. Spine (Phila Pa 1976) 2015;40(04):E191-E198
-
22Meyer D, Meyer F, Kretschmer T, Börm W. Translaminar screws of the axis - an alternative technique for rigid screw fixation in upper cervical spine instability. Neurosurg Rev 2012;35(02):255-261
-
23Chun DH, Yoon DH, Kim KN, Yi S, Shin DA, Ha Y. Biomechanical Comparison of Four Different Atlantoaxial Posterior Fixation Constructs in Adults: A Finite Element Study. Spine (Phila Pa 1976) 2018;43(15):E891-E897
-
24Sai Kiran NA, Sivaraju L, Vidyasagar K, et al. Safety and Accuracy of Anatomic and Lateral Fluoroscopic-Guided Placement of C2 Pars/ Pedicle Screws and C1 Lateral Mass Screws, and Freehand Placement of C2 Laminar Screws. World Neurosurg 2018;118: e304-e315
-
25Lehman RA Jr, Dmitriev AE, Helgeson MD, Sasso RC, Kuklo TR, Riew KD. Salvage of C2 pedicle and pars screws using the intralaminar technique: a biomechanical analysis. Spine (Phila Pa 1976) 2008;33(09):960-965
-
26Dobran M, Nasi D, Esposito DP, Iacoangeli M. Posterior Fixation with C1 Lateral Mass Screws and C2 Pars Screws for Type II Odontoid Fracture in the Elderly: Long-Term Follow-Up. World Neurosurg 2016;96:152-158
-
27Chin KR, Mills MV, Seale J, Cumming V. Ideal starting point and trajectory for C2 pedicle screw placement: a 3D computed tomography analysis using perioperative measurements. Spine J 2014;14(04):615-618
-
28Dean CL, Lee MJ, Robbin M, Cassinelli EH. Correlation between computed tomography measurements and direct anatomic measurements of the axis for consideration of C2 laminar screw placement. Spine J 2009;9(03):258-262
Publication Dates
-
Publication in this collection
12 May 2023 -
Date of issue
Jan-Feb 2023
History
-
Received
02 Jan 2022 -
Accepted
20 Jan 2022