Open-access Incremental Value Of 3D Transesophageal Echocardiography for The Assessment of Mitral Valve Prolapse

Echocardiography, Transesophageal / utilization; Echocardiography, Three Dimensional / utilization; Mitral Valve Prolapse

A 90-year-old asymptomatic patient with atrial fibrillation underwent a transesophageal echocardiography (TEE) for the assessment of thrombus. The TEE examination evidenced mitral valve anterior leaflet prolapse with moderate to severe eccentric regurgitation. Three-dimensional (3D)-TEE was performed and showed chordal rupture (A2) related to the anterior scallop of the mitral valve (Figure 1 e video 1). In this case, 3D-TEE provided additional anatomical information regarding the mitral valve, allowing the diagnosis of flail leaflet and chordal rupture, not assessed by the 2D evaluation.

Figure 1
2D-TEE, four-chamber view showing mitral valve prolapse at 0° (A) e 34° (B) rotation of imaging array. C and D. 2D TEE color flow mapping evidencing eccentric mitral regurgitation, directed posteriorly at 0° (C) and 138° (D) rotation of imaging array. E and F. 3D-TEE images showing the mitral valve prolapse of the anterior leaflet (A2) (E, arrow), in a surgical view (from the left atrium, LA) and chordal rupture (F, arrow). TEE: transesophageal echocardiography; RA: right atrium; RV: right ventricule; LV: left ventricule; AO: aorta.
Video 1
Additional Supporting Information: Real time 3D TEE cine loops evidence chordal rupture (A2) associated with mitral valve prolapse.

Publication Dates

  • Publication in this collection
    Apr 2015

History

  • Received
    01 Sept 2014
  • Reviewed
    08 Sept 2014
  • Accepted
    08 Sept 2014
location_on
Sociedade Brasileira de Cardiologia - SBC Avenida Marechal Câmara, 160, sala: 330, Centro, CEP: 20020-907, (21) 3478-2700 - Rio de Janeiro - RJ - Brazil, Fax: +55 21 3478-2770 - São Paulo - SP - Brazil
E-mail: revista@cardiol.br
rss_feed Acompanhe os números deste periódico no seu leitor de RSS
Acessibilidade / Reportar erro