Acessibilidade / Reportar erro

Ultraviolet-A absorbance analysis in thin porcine corneas pre-and post-crosslinking

ABSTRACT

Purpose:

To determine the absorbance coefficient of the thin porcine cornea to ultraviolet-A radiation (365 nm) submitted for crosslinking.

Methods:

This in vitro, benchtop experiment using cadaver tissue study analyzed 12 porcine corneal lamellas, which were obtained using a microkeratome after mechanical de-epithelization and separated into three thickness groups: 180, 300, and 360 μm. The corneal thickness values were measured by anterior-segment optical coherence tomography. All lamellas had ultraviolet-A (365 nm) absorbance measured with a 96-well plate spectrophotometer using an ultraviolet transparent microplate before riboflavin instillation and preand post-crosslinking according to the Dresden protocol.

Results:

The ultraviolet absorbance profiles of the 180, 300, and 360 μm groups were obtained as α-coefficients of 12.85, 76.55, and 120.27, respectively. A theoretical formula was calculated though a statistical analysis that demonstrated the correlation between stromal lamellar thickness and ultraviolet absorbance.

Conclusions:

Corneal thickness and ultraviolet-A spectral absorbance of corneal lamellas showed linear correlation. These findings can potentially contribute to the optimization of ultraviolet-A application during crosslinking, making the treatment of corneas with thickness <400 μm safe and personalized energy delivery for each corneal thickness.

Keywords
Ultraviolet light; Spectrophotometry; Crosslinking; Keratoconus; Corneal thickness

INTRODUCTION

Keratoconus is a corneal ectasia that presents with progressive corneal thinning, a typical disorder finding. To halt this behavior, crosslinking became the primary surgical option, and several studies have evaluated its safety and efficacy(11 Spoerl E, Huhle M, Seiler T. Induction of cross-links in corneal tissue. Exp Eye Res. 1998;66(1):97-103.

2 Wollensak G, Spoerl E, Seiler T. Riboflavin/ultraviolet-a-induced collagen crosslinking for the treatment of keratoconus. Am J Ophthalmol. 2003;135(5):620-7.
-33 Hashemi H, Seyedian MA, Miraftab M, Fotouhi A, Asgari S. Corneal collagen cross-linking with riboflavin and ultraviolet a irradiation for keratoconus: long-term results. Ophthalmology. 2013;120(8):1515-20.). However, crosslinking in thin corneas (<400 μm of corneal thickness) can result in high risks of complications, mainly regarding the endothelium(44 Sharma A, Nottage JM, Mirchia K, Sharma R, Mohan K, Nirankari VS. Persistent corneal edema after collagen cross-linking for keratoconus. Am J Ophthalmol. 2012;154(6):922-926.e1.). Thus, some options have become available in the last few years, including transepithelial crosslinking, contact lens-assisted crosslinking, hypo-osmolar crosslinking, custom epithelial debridement, and lenticu-le--assisted crosslinking(55 Filippello M, Stagni E, O’Brart D. Transepithelial corneal collagen crosslinking: bilateral study. J Cataract Refract Surg. 2012;38(2): 283-91.

6 Kymionis GD, Diakonis VF, Coskunseven E, Jankov M, Yoo SH, Pallikaris IG. Customized pachymetric guided epithelial debridement for corneal collagen cross linking. BMC Ophthalmol. 2009;9(1):10.

7 Jacob S, Kumar DA, Agarwal A, Basu S, Sinha P, Agarwal A. Contact lens-assisted collagen cross-linking (CACXL): A new technique for cross-linking thin corneas. J Refract Surg. 2014;30(6):366-72.
-88 Sachdev MS, Gupta D, Sachdev G, Sachdev R. Tailored stromal expansion with a refractive lenticule for crosslinking the ultrathin cornea. J Cataract Refract Surg. 2015;41(5):918-23.). Nevertheless, these are good options; however, none has similar efficacy to that of the Dresden protocol, consequently showing higher failure rates. These very thin corneas have higher risks of damaging the endothelium(22 Wollensak G, Spoerl E, Seiler T. Riboflavin/ultraviolet-a-induced collagen crosslinking for the treatment of keratoconus. Am J Ophthalmol. 2003;135(5):620-7.). If the absorption coeffi-cient were known, we could fine-tune UV radiation delivery to crosslink the cornea and not damage the endothelium.

Hypo-osmolar crosslinking, as one of the most used options, is based on the assumption that a hydrated cornea becomes thicker, and this can prevent endothelium damage(99 Raiskup F, Spoerl E. Corneal cross-linking with hypo-osmolar riboflavin solution in thin keratoconic corneas. Am J Ophthalmol. 2011;152(1):28-32.e1.,1010 Hafezi F, Mrochen M, Iseli HP, Seiler T. Collagen crosslinking with ultraviolet-A and hypoosmolar riboflavin solution in thin corneas. J Cataract Refract Surg. 2009;35(4):621-4.). However, as previously described, hydrated corneas submitted for crosslinking showed a smaller collagen organization. This change appeared to be temporary when compared with control groups(1111 Bottós KM, Hofling-Lima AL, Barbosa MC, Barbosa JB Jr, Dreyfuss JL, Schor P, et al. Effect of collagen cross-linking in stromal fibril organization in edematous human corneas. Cornea. 2010;29(7):789-93.). By contrast, even when using hypo-osmolar riboflavin, some corneas did not demonstrate a more significant increase in thickness, making it unpredictable to proceed with the procedure.

The Dresden protocol involves applying ultraviolet-A (UV-A) radiation in 365 nm, 3.0 mW/cm2, for 30 min, reaching 5.4 J/cm2, in a cornea previously saturated with riboflavin 0.1%(22 Wollensak G, Spoerl E, Seiler T. Riboflavin/ultraviolet-a-induced collagen crosslinking for the treatment of keratoconus. Am J Ophthalmol. 2003;135(5):620-7.) for 30 min. A corneal thickness value of >400 μm at the corneal thinnest point without epithelium is the security barrier for endothelium protection, as the toxic endothelium threshold (0.35 mW/cm2) and the toxic threshold of total energy (0.63 J/cm2) were not reached(1212 Wollensak G, Spörl E, Reber F, Pillunat L, Funk R. Corneal endothelial cytotoxicity of riboflavin/UVA treatment in vitro. Ophthalmic Res. 2003;35(6):324-8.).

Thus, this study aimed to describe the UV-A absorbance pattern in thin porcine corneas before and after riboflavin instillation and post-crosslinking, creating a theoretical absorbance profile that can enable UV-A radiation delivery optimization according to corneal thickness.

METHODS

Corneal specimen preparation

This study examined 12 porcine thin corneal lamellas, which were obtained using a microkeratome (Moria, LSK-ONE, France) after mechanical de-epithelialization and were then separated into three thickness groups: 180, 300, and 360 μm. Immediately after the microkeratome cut, lamellas were evaluated by an-terior--segment optical coherence tomography (Optovue, Fremont, EUA) for corneal thickness measurement. The diameter of all lamellas was adjusted with a trephine to fit in the 96-well plate and positioned at the bottom plate, perpendicular to the beam of light.

All porcine eyes were obtained from a slaughterhouse, examined within 6 h after enucleation, and transported in a wet chamber made with a plastic cup containing wet gauze above and below the globe.

Crosslinking procedure

During the saturation period, an iso-osmolar riboflavin 0.1%, 400 mOsm 20% dextran (Ophthalmos, Sao Paulo, Brazil) was used, with one drop every 5 min. All lamellas had UV-A absorbance measurements at 365 nm before and after the instillation and post-crosslinking procedure. Lamella thickness was assumed constant throughout the experiment, as an isosmolar riboflavin was used.

According to the Dresden protocol, crosslinking was performed using an Opto XLink (Opto, Sao Carlos, Brazil).

Absorbance determination

A 96-well UV transparent microplate was used to determine the UV absorbance of lamellas. Measurements were obtained using an Epoch 2 spectrophotometer (Biotech Instruments, USA). The 365-nm range used during crosslinking was selected. The analyses were performed at ambient temperature (approximately 27°C).

Estimate of absorbance coefficient

Regarding the theoretical model used to estimate the UV absorbance coefficient of the porcine anterior corneal stroma, the Beer-Lambert law was followed. This law states that the absorbance (A) of a beam of collimated monochromatic radiation (in this case, UV-A 365 nm) in a homogenous material (anterior corneal stroma) is proportional to the absorption path length (d), in this case, corneal thickness, and to the absorbance coefficient (α), which is a characteristic of the material(1313 IUPAC. Compendium of Chemical Terminology, 2nd ed. (the “Gold Book”). Compiled by A. D. McNaught AD, Wilkinson A. Oxford: Blackwell Scientific Publications; 1997. Vol. 68. p.2223-30.). In addition, transmittance (T) is defined as the ratio of the transmitted intensity (I) over the incident intensity (I0) and assumes values between 0 and 1. Finally, the absorbance of the material is related to the transmittance, that is, to the incident, and transmitted intensities, through the following equations:

(equation 1) T = l / l 0 = e - α d
(equation 2) A = - log l / l 0
(equation 3) A = - log e - α d => A = α d log e
(equation 4) A = 0.43 α d

where:

A = absorbance

α = absorption coefficient (cm-1)

d = optical pathway (corneal thickness) (cm)

T = transmittance

I = transmitted light intensity (mW)

Io = incident light intensity (mW)

e = Euler’s number

Thus, an exponential relation was found between light-transmitted intensity (I) and corneal thickness (d). In addition, a linear relation was found between absorbance (-log I/I0) and corneal thickness (d) since the material absorbance coefficient (α) is constant as a material characteristic.

After calculating all measures, the absorbance of each corneal lamella’s UV-A (365 nm) was obtained. The angular coefficient corresponds to the absorbance coefficient (α) through linear regression.

Finally, according to the Dresden protocol2, a work power value of 3 mW/cm2 was safe for the endothelium in corneas with stromal thickness of >400 μm. Thus,

(equation 5) P ( e ) = P ( D ) × e - α ( D )
(equation 6) P ( D ) × e - α ( D ) = P ( d ) × e - α ( d )
(equation 7) P ( d ) = P ( D ) × e - α ( D - d )

where:

P (e) = maximal work power at endothelium (mW/cm2)

P (D) = work power according to the Dresden protocol (3 mW/cm2 considering D = 400 μm stromal thickness)

P (d) = work power according to corneal thickness (mW/cm2)

α = absorption coefficient (cm-1)

d = optical pathway (corneal thickness) (cm)

e = Euler’s number

After the α constant was determined, the optimized work power was calculated according to each corneal thickness, using the following equation:

(equation 8) P ( d ) = 3 × e - α ( 0.04 - d )

Therefore, this final equation can make it possible to correlate corneal thickness and work power on the crosslinking device .

RESULTS

This study revealed a linear correlation between corneal thickness and corneal UV-A (365 nm) absorbance (A) in corneal lamellas previously soaked with riboflavin.

All lamellas had UV-A absorbance measured by a spectrophotometer preand post-riboflavin soaking and post-crosslinking, and the results are presented in table 1. The mean corneal thickness in the 180, 300, and 360 μm groups were 219.50, 322, and 377 μm, respectively. As intended, each thickness value was analyzed individually and not as a group to obtain results for every sample with different thickness values, with a linear and progressive character, from the thinnest to the thickest lamella, which, ultimately, would optimize results. The biomechanical effects of crosslinking are already widely known, so they were not the focus of this study, which aimed to identify changes in the absorption of UV energy by the tissue.

Table 1
Total UV-A absorbance (365 nm) of lamellas in all groups, without microplate absorbance. Pachymetry values are presented in cm

Pre-soaking lamellas had a lower absorbance variability, with some thinner lamellas absorbing even more energy than thicker lamellas in a similar range. This group showed a weak linear correlation between corneal thickness and UV absorbance (Figure 1).

Figure 1
Absorbance of thin porcine cornea and alpha values.

A linear correlation was found in the post-soaking lamellas because thicker lamellas showed a higher UV absorbance profile than thinner lamellas. Moreover, the post-crosslinking samples had an even higher correlation (Figure 1). This linear correlation was achieved because of the exponential behavior reduced by the log. That is, although the absorbance ratio was linear, the power ratio that can be safely applied will be logarithmic. The microplate was also tested for UV absorbance, showing a low value of 0.043, considered in all calculations.

After this, the α-coefficient was determined for each group according to the previously mentioned equations, and the results are presented in figure 1. The pre-soaking, post-soaking, and post-crosslinking groups showed 12.85, 76.55, and 120.27, respectively. At this point, linear regression calculated how all groups absorbed UV-A, according to each corneal thickness (Figure 1).

Finally, the post-riboflavin coefficient was used to calculate the optimized work power because at this moment UV irradiation starts during the crosslinking procedure (Table 2). With this optimization, for each corneal thickness, suggesting a working power that theo-retically will not reach the toxic endothelial threshold was already possible.

Table 2
Work power according to pachymetry using post-riboflavin alpha value

DISCUSSION

Thinner lamellas had a lower absorbance profile than thicker lamellas, and the proposed theoretical model was made ex vivo using porcine corneas. Therefore, through energy optimization, the barrier of 400 μm of corneal stromal thickness for crosslinking can be overcome(22 Wollensak G, Spoerl E, Seiler T. Riboflavin/ultraviolet-a-induced collagen crosslinking for the treatment of keratoconus. Am J Ophthalmol. 2003;135(5):620-7.).

The pre-soaking group demonstrated a lower varia-bility, with thinner corneas absorbing sometimes more UV-A energy than thicker corneas, even in low order. This was possibly explained by the lower absorbance coefficient of the corneal stroma to the UV-A radiation(1313 IUPAC. Compendium of Chemical Terminology, 2nd ed. (the “Gold Book”). Compiled by A. D. McNaught AD, Wilkinson A. Oxford: Blackwell Scientific Publications; 1997. Vol. 68. p.2223-30.,1414 Kolozsvári L, Nógrádi A, Hopp B, Bor Z. UV absorbance of the human cornea in the 240- to 400-nm range. Invest Ophthalmol Vis Sci. 2002;43(7):2165-8.), mainly in thin lamellas, which makes less difference when analyzing all group thicknesses. Post--soaking and post-crosslinking groups showed a linear correlation between these two variables.

This study used iso-osmolar riboflavin 0.1% (400 mOsm), and crosslinking is possible with hypo-osmolar riboflavin (310 mOsm), which can induce corneal edema, increase thickness, and protect the endothelium(99 Raiskup F, Spoerl E. Corneal cross-linking with hypo-osmolar riboflavin solution in thin keratoconic corneas. Am J Ophthalmol. 2011;152(1):28-32.e1.,1010 Hafezi F, Mrochen M, Iseli HP, Seiler T. Collagen crosslinking with ultraviolet-A and hypoosmolar riboflavin solution in thin corneas. J Cataract Refract Surg. 2009;35(4):621-4.). However, this strategy may not be adequate to prevent progression(1515 Hafezi F. Limitation of collagen cross-linking with hypoosmolar riboflavin solution: failure in an extremely thin cornea. Cornea. 2011;30(8):917-9.). Transepithelial crosslinking(55 Filippello M, Stagni E, O’Brart D. Transepithelial corneal collagen crosslinking: bilateral study. J Cataract Refract Surg. 2012;38(2): 283-91.), custom epithelial debridement at the cone apex(66 Kymionis GD, Diakonis VF, Coskunseven E, Jankov M, Yoo SH, Pallikaris IG. Customized pachymetric guided epithelial debridement for corneal collagen cross linking. BMC Ophthalmol. 2009;9(1):10.), and contact lens-assisted crosslinking(77 Jacob S, Kumar DA, Agarwal A, Basu S, Sinha P, Agarwal A. Contact lens-assisted collagen cross-linking (CACXL): A new technique for cross-linking thin corneas. J Refract Surg. 2014;30(6):366-72.) may also halt progression on thin corneas(1616 Deshmukh R, Hafezi F, George D. Kymionis, Sabine Kling, Rupal Shah, Prema Padmanabhan MSS. Current concepts in crosslinking thin corneas. Indian J Ophthalmol. 2019;67(1):948-9.). Therefore, none of them emphasize the main problem, which is the higher energy delivery to the cornea, which exceeds the toxic endothelium threshold. Moreover, these alternatives have higher failure rates than the Dresden protocol, which is still the gold standard. The use of human corneal lamellas from smile procedures is another option(88 Sachdev MS, Gupta D, Sachdev G, Sachdev R. Tailored stromal expansion with a refractive lenticule for crosslinking the ultrathin cornea. J Cataract Refract Surg. 2015;41(5):918-23.); however, a corneal transplant technique involves tissue rejection risks and depends on the availability of technology and donors.

In another study, porcine corneas submitted with smaller intensities of UV-A (1.5 mW/cm2) exerted a biomechanical stiffening effect similar to that of the Dresden protocol. This finding also supports the idea that UV-A energy delivery can be reduced, possibly maintaining biochemical, and clinical crosslinking effects, even in corneas thinner than 400 μm(1717 Kling S, Hafezi F. Biomechanical stiffening: slow low-irradiance corneal crosslinking versus the standard Dresden protocol. J Cataract Refract Surg. 2017;43(7):975-9.). Therefore, for these extreme cases reducing fluence and irradiance during crosslinking can be an option.

Hafezi et al. reported another alternative for the treat-ment of thin corneas(1818 Hafezi F, Kling S, Gilardoni F, Hafezi N, Hillen M, Abrishamchi R, et al. Individualized corneal cross-linking with riboflavin and UV-A in ultrathin corneas: The Sub400 protocol. Am J Ophthalmol. 2021;224:133-42.). They proposed the “sub-400 protocol”, in which, using a theoretical formula, the fluency of the UV energy needed for each patient was estimated according to corneal thickness. However, in their formula, they kept the work power constant at 3 mW/cm2, varying the time of exposure to UV energy; however, this study proposes to keep the time constant, varying the work power applied to the cornea. Since studies have already prove the production of crosslinking in scenarios with less work power, this other approach is reasonable for future comparative works(1717 Kling S, Hafezi F. Biomechanical stiffening: slow low-irradiance corneal crosslinking versus the standard Dresden protocol. J Cataract Refract Surg. 2017;43(7):975-9.,1818 Hafezi F, Kling S, Gilardoni F, Hafezi N, Hillen M, Abrishamchi R, et al. Individualized corneal cross-linking with riboflavin and UV-A in ultrathin corneas: The Sub400 protocol. Am J Ophthalmol. 2021;224:133-42.).

This study has the following limitations: relatively small number of samples and mechanical creation of lamellas (instead of femtosecond-created ones), which increased thickness variability. The use of four lamellas in each group, instead of the intended three, was an attempt to improve accuracy regarding this possible variability when performing mechanical LASIK. Conversely, this study evaluated the main barrier to crosslinking thinner corneas and the higher amount of energy delivered and proposed a viable alternative that can be further explored.

Further complementary studies are needed to evaluate this energy optimization in vivo on thin corneas and analyze histopathological, biochemical, and biomechanical behaviors. Owing to the reduction of energy delivery according to corneal thickness, the potential harms of this strategy are minimized because the toxic endothelial threshold was not reached. Although the maximum energy level to perform crosslinking is already known, the minimum energy required for each patient is still being investigated, and reducing this energy at lower levels can be a solution to reduce the incidence of some crosslinking complications, such as corneal haze, progressive flattening, persistent epithelial defects, and endotheliitis, which can be related to the amount of energy delivered(1919 Belin MW, Lim L, Rajpal RK, Hafezi F, Gomes JA, Cochener B. Corneal Cross-Linking: Current USA Status: Report From the Cornea Society. Cornea. 2018;37(10):1218-25.).

Several crosslinking instruments are currently available, and many already have control over energy optimization, which could facilitate the adoption of this irradiance modification, as they would be ready for use(2020 Rodrigues R, Stefani MA. Chamon W. Crosslinking instrumentation. In: Azar D, editor. Refractive surgery. 3rd ed. Elsevier; 2019. p. 562.,2121 Malta JB, Renesto AC, Moscovici BK, Soong HK, Campos M. Stromal demarcation line induced by corneal cross-linking in eyes with keratoconus and nonkeratoconic asymmetric topography. Cornea. 2015;34(2):199-203.).

Finally, the results of this study revealed a linear correlation between porcine corneal thickness and UV-A absorbance. Through this theoretical model, the amount of energy each corneal thickness can support during crosslinking can be calculated, making personalized treatment for each thickness possible.

  • Approved by the following research ethics committee: Universidade Federal de São Paulo (CEUA no. 5055230916).

ACKNOWLEDGMENT

Special thanks to Prof. Dr. Wallace Chamon.

  • Funding: This study received no specific financial support.

REFERENCES

  • 1
    Spoerl E, Huhle M, Seiler T. Induction of cross-links in corneal tissue. Exp Eye Res. 1998;66(1):97-103.
  • 2
    Wollensak G, Spoerl E, Seiler T. Riboflavin/ultraviolet-a-induced collagen crosslinking for the treatment of keratoconus. Am J Ophthalmol. 2003;135(5):620-7.
  • 3
    Hashemi H, Seyedian MA, Miraftab M, Fotouhi A, Asgari S. Corneal collagen cross-linking with riboflavin and ultraviolet a irradiation for keratoconus: long-term results. Ophthalmology. 2013;120(8):1515-20.
  • 4
    Sharma A, Nottage JM, Mirchia K, Sharma R, Mohan K, Nirankari VS. Persistent corneal edema after collagen cross-linking for keratoconus. Am J Ophthalmol. 2012;154(6):922-926.e1.
  • 5
    Filippello M, Stagni E, O’Brart D. Transepithelial corneal collagen crosslinking: bilateral study. J Cataract Refract Surg. 2012;38(2): 283-91.
  • 6
    Kymionis GD, Diakonis VF, Coskunseven E, Jankov M, Yoo SH, Pallikaris IG. Customized pachymetric guided epithelial debridement for corneal collagen cross linking. BMC Ophthalmol. 2009;9(1):10.
  • 7
    Jacob S, Kumar DA, Agarwal A, Basu S, Sinha P, Agarwal A. Contact lens-assisted collagen cross-linking (CACXL): A new technique for cross-linking thin corneas. J Refract Surg. 2014;30(6):366-72.
  • 8
    Sachdev MS, Gupta D, Sachdev G, Sachdev R. Tailored stromal expansion with a refractive lenticule for crosslinking the ultrathin cornea. J Cataract Refract Surg. 2015;41(5):918-23.
  • 9
    Raiskup F, Spoerl E. Corneal cross-linking with hypo-osmolar riboflavin solution in thin keratoconic corneas. Am J Ophthalmol. 2011;152(1):28-32.e1.
  • 10
    Hafezi F, Mrochen M, Iseli HP, Seiler T. Collagen crosslinking with ultraviolet-A and hypoosmolar riboflavin solution in thin corneas. J Cataract Refract Surg. 2009;35(4):621-4.
  • 11
    Bottós KM, Hofling-Lima AL, Barbosa MC, Barbosa JB Jr, Dreyfuss JL, Schor P, et al. Effect of collagen cross-linking in stromal fibril organization in edematous human corneas. Cornea. 2010;29(7):789-93.
  • 12
    Wollensak G, Spörl E, Reber F, Pillunat L, Funk R. Corneal endothelial cytotoxicity of riboflavin/UVA treatment in vitro. Ophthalmic Res. 2003;35(6):324-8.
  • 13
    IUPAC. Compendium of Chemical Terminology, 2nd ed. (the “Gold Book”). Compiled by A. D. McNaught AD, Wilkinson A. Oxford: Blackwell Scientific Publications; 1997. Vol. 68. p.2223-30.
  • 14
    Kolozsvári L, Nógrádi A, Hopp B, Bor Z. UV absorbance of the human cornea in the 240- to 400-nm range. Invest Ophthalmol Vis Sci. 2002;43(7):2165-8.
  • 15
    Hafezi F. Limitation of collagen cross-linking with hypoosmolar riboflavin solution: failure in an extremely thin cornea. Cornea. 2011;30(8):917-9.
  • 16
    Deshmukh R, Hafezi F, George D. Kymionis, Sabine Kling, Rupal Shah, Prema Padmanabhan MSS. Current concepts in crosslinking thin corneas. Indian J Ophthalmol. 2019;67(1):948-9.
  • 17
    Kling S, Hafezi F. Biomechanical stiffening: slow low-irradiance corneal crosslinking versus the standard Dresden protocol. J Cataract Refract Surg. 2017;43(7):975-9.
  • 18
    Hafezi F, Kling S, Gilardoni F, Hafezi N, Hillen M, Abrishamchi R, et al. Individualized corneal cross-linking with riboflavin and UV-A in ultrathin corneas: The Sub400 protocol. Am J Ophthalmol. 2021;224:133-42.
  • 19
    Belin MW, Lim L, Rajpal RK, Hafezi F, Gomes JA, Cochener B. Corneal Cross-Linking: Current USA Status: Report From the Cornea Society. Cornea. 2018;37(10):1218-25.
  • 20
    Rodrigues R, Stefani MA. Chamon W. Crosslinking instrumentation. In: Azar D, editor. Refractive surgery. 3rd ed. Elsevier; 2019. p. 562.
  • 21
    Malta JB, Renesto AC, Moscovici BK, Soong HK, Campos M. Stromal demarcation line induced by corneal cross-linking in eyes with keratoconus and nonkeratoconic asymmetric topography. Cornea. 2015;34(2):199-203.

Publication Dates

  • Publication in this collection
    04 Mar 2024
  • Date of issue
    2024

History

  • Received
    12 Aug 2022
  • Accepted
    25 Apr 2023
Conselho Brasileiro de Oftalmologia Rua Casa do Ator, 1117 - cj.21, 04546-004 São Paulo SP Brazil, Tel: 55 11 - 3266-4000, Fax: 55 11- 3171-0953 - São Paulo - SP - Brazil
E-mail: abo@cbo.com.br