Acessibilidade / Reportar erro

Bond Strength of a Bisphenol-A-Free Fissure Sealant With and Without Adhesive Layer under Conditions of Saliva Contamination

Abstract

Dental sealants are important for prevention of carious lesions, if they have good shear strength. The aim of this study was to evaluate the shear bond strength (SBS) of two sealants to saliva-contaminated and non-contaminated enamel with and without an intermediate adhesive layer underneath the sealant. Ninety flat enamel surfaces from human third molars were randomly assigned to 6 groups (n=15): F (control): Fluroshield(tm) sealant; EWB (control): Embrace(tm) WetBond(tm); SB/F: Single Bond adhesive system + F; SB/EWB, s-SB/F and s-SB/EWB. In the s-SB/F and s-SB/EWB groups, the acid-etched enamel was contaminated with 0.01 mL of fresh human saliva for 20 s. Sealant cylinders were bonded to enamel surface with and without an intermediate adhesive system layer. The shear tests were performed using a universal testing machine (0.5 mm/min). Data were analyzed statistically by Kruskal-Wallis and Mann-Whitney tests (α=0.05). F presented higher mean SBS than EWB in all experimental conditions. The lowest SBS mean was obtained for EWB on contaminated enamel (p<0.05). In conclusion, an adhesive system layer should be used prior to sealant placement, in both dry and saliva-contaminated enamel. F had the best performance in all experimental conditions. EWB sealant showed very low results, but an adhesive layer underneath the sealant increased its SBS even after salivary contamination.

Key Words:
fissure sealants; shear strength; Bisphenol-A.

Resumo

Selantes dentários são importantes para a prevenção de lesões de cárie desde que tenham boa resistência ao cisalhamento. O objetivo deste trabalho foi avaliar a resistência ao cisalhamento (SBS), de dois selantes em esmalte contaminado e não contaminado com saliva, com e sem uma camada adesiva intermediária sob o selante. Noventa superfícies de esmalte de terceiros molares humanos foram planificadas e divididas aleatoriamente em 6 grupos (n=15): F (controle): selante Fluroshield(tm); EWB (controle): Embrace(tm) WetBond(tm); SB/F: sistema adesivo Single Bond + F; SB/EWB, s-SB/F and s-SB/EWB. Nos grupos s-SB/F e s-SB/EWB, a contaminação do esmalte condicionado foi obtida com 0,01 mL de saliva humana fresca durante 20 s. Cilindros de selante foram colocados sobre a superfície do esmalte com e sem uma camada de sistema adesivo intermediária. Os ensaios de cisalhamento foram realizados utilizando uma máquina universal de ensaios (0,5 mm/min). Os dados foram analisados estatisticamente pelo teste de Kruskal-Wallis e Mann-Whitney (?#61537;=0,05). F apresentou valores médios de SBS maiores do que EWB em todas as condições experimentais. O menor valor médio de SBS foi obtido pelo EWB em esmalte contaminado (p<0,05). Em conclusão, uma camada de sistema de adesivo deve ser utilizada antes da colocação do selante, tanto em superfície seca quanto contaminada por saliva. F teve o melhor desempenho em todas as condições experimentais. O selante EWB apresentou resultados insatisfatórios, porém o uso de uma camada adesiva abaixo do selante aumentou sua SBS, mesmo após a contaminação salivar.

Introduction

Fissure sealants used as preventive treatment on occlusal surfaces act as an effective mechanical barrier against the accumulation and maturation of biofilm 11. Prabhakar, AR; Murthy, SA; Sugandhan, S. Comparative evaluation of the length of resin tags, viscosity and microleakage of pit and fissure sealants - an in vitro scanning electron microscope study. Contemp Clin Dent 2011;2:324-330., especially if it remains intact and bonded to tooth surface 22. Panigrahi, A; Srilatha, KT; Panigrahi, RG; Mohanty, S; Bhuyan, SK; Bardhan, D. Microtensile bond strength of Embrace WetBond hydrophilic sealant in different moisture contamination: an in-vitro study. J Clin Diagn Res 2015;9:ZC23-ZC25.,33. Simonsen, RJ; Neal, NC. A review of the clinical application and performance of pit and fissure sealants. Aust Dent J 2011;56:45-58..

The ideal time for sealant placement is soon after the eruption of permanent molars 44. Gomes-Silva, JM; Torres, CP; Contente, MMMG; Oliveira, MAHM; Palma-Dibb, RG; Borsatto, MC. Bond strength of a pit-and-fissure sealant associated to etch-and-rinse and self-etching adhesive systems to saliva-contaminated enamel: individual vs. simultaneous light curing. Braz Dent J 2008;19:341-347., as newly erupted teeth are less mineralized and more susceptible to acid attack 55. Waggoner, WF. Managing occlusal surfaces of young permanent molars. J Am Dent Assoc 1991;122:72-76.. However, sealant placement during this period is challenging because the contact of the tooth with the distal marginal ridge of the gingiva facilitates the contamination of the occlusal surface by moisture or saliva 66. Locke, D; Jokovic, A; Kay, EJ. Prevention. Part 8: The use of pit and fissure sealants in preventing caries in the permanent dentition of children. Br Dent J 2003;195:375-378., which is the most common cause of sealant failure 22. Panigrahi, A; Srilatha, KT; Panigrahi, RG; Mohanty, S; Bhuyan, SK; Bardhan, D. Microtensile bond strength of Embrace WetBond hydrophilic sealant in different moisture contamination: an in-vitro study. J Clin Diagn Res 2015;9:ZC23-ZC25.. The microspores produced by acid etching may be partially occluded after a contamination time as short as one second 77. Silverstone, LM; Hicks, MJ; Featherstone, MJ. Oral fluid contamination of etched enamel surfaces: an SEM study. J Am Dent Assoc 1985;110:329-332.. This partial obliteration prevents the ideal formation of resin tags, thus weakening sealant retention 88. Hormati, AA; Fuller, JL; Denehy, GE. Effects of contamination and mechanical disturbance on the quality of acid-etched enamel. J Am Dent Assoc 1980;100:34-38..

Conventional pit and fissure sealants are extremely sensitive to moisture due to their hydrophobic nature and thus require a clean, dry and etched enamel surface during placement 99. Khatri, SG; Samuel,SR; Acharya, S; Patil, S; Madan, K. Retention of moisture-tolerant and conventional resin-based sealant in six- to nine-year-old children. Pediatr Dent 2015;37:366-370.. In addition, resin-based materials, although more and more popular like composite resins and pit and fissure sealants, have caused concern due to the presence of 2,2-bis(4-hydroxyphenyl)propane (Bisphenol A - BPA) 1010. Lang, IA; Galloway, TS; Scarlett, A; Henley, WE; Depledge M; Wallace RB et al.. Association of urinary bisphenol A concentration with medical disorders and laboratory abnormalities in adults. J Am Dent Assoc 2008;300:1303-1310.. BPA is a plastic used in the fabrication of several other products, including bottles, baby bottles, detergents, food packing and its derivatives, may present hazard to health 1111. Fleisch, AF; Sheffield, PE; Chinn, C; Edelstein, BL; Landrigan PJ. Bisphenol A and related compounds in dental materials. Pedriatics 2010;126:760-768..

Some studies found that BPA could induce changes in various mechanisms and physiological processes, among which early puberty in females and feminization in male at very low levels 1212. Timms, BG; Howdeshell, KL; Barton, L; Bradley, S; Richter CA; vom Saal FS. Estrogenic chemicals in plastic and oral contraceptives disrupt development of the fetal mouse prostate and urethra. Proc Natl Acad Sci USA 2005;102:7014-7019., high-risk breast and prostate cancer 1313. Sasco, AJ. Epidemiology of breast cancer: an environmental disease? APMIS 2001;109:321-332., calcium influx induction, which leads to release of prolactin 1414. Palanza, P; Howdeshell, KL; Parmigiani, S; vom, Saad FS. Exposure to a low dose of bisphenol A during fetal life or in adulthood alters maternal behavior in mice. Environ Health Perspect 2002;110Suppl 3:415-422., development of hyperglycemia, insulin tolerance and diabetes 1515. Alonso-Magdalena, P; Morimoto, S; Rípoli, C; Fuentes, E; Nadal, A. The estrogenic effect of bisphenol A disrupts the pancreatic β-cell function in vivo and induces insulin resistance. Environ Health Perspect 2006;114:106-112., cardiovascular disease 1010. Lang, IA; Galloway, TS; Scarlett, A; Henley, WE; Depledge M; Wallace RB et al.. Association of urinary bisphenol A concentration with medical disorders and laboratory abnormalities in adults. J Am Dent Assoc 2008;300:1303-1310., abnormal concentration of Y-glutamyl liver enzymes and alkaline phosphatase 1616. Bindhumol, V; Chitra, KC; Mathur, PP. Bisphenol A induces reactive oxygen species generation in the liver of male rats. Toxicology 2003;188:117-124., according to the switching of the β-pancreatic cells 1717. Ropero, AB; Alonso-Magdalena, P; García-García ,E; Rípoli C; Fuentes E; Nadal A. Bisphenol A disruption of the endocrine pancreas and blood glucose homeostasis. Int J Androl 2008;31:194-200., dysfunction of thyroid hormone production 1818. Moriyama, K; Tagami, T; Akamizu, T; Usui, T; Saijo, M; Kanamoto, N et al.. Thyroid hormone action is disrupted by bisphenol A as an antagonist. J Clin Endocrinol Metab 2002;87:5185-5190., increase of reactive oxygen species 1919. Ooe, H; Tkahiro, T; Iguchi-Ariga, SMM; Ariga, H. Induction of reactive oxygen species by bisphenol A and abrogation of bisphenol A induced cell injury by DJ-I. Toxicol Sci 2005;88:114-126., which are implicated in oxidative stress mechanism and over-regulation of cAMP response element binding protein, which inhibits apoptosis 2020. Quesada, I; Fuentes, E; Viso-León, MC; Soria, B; Rípoli, C; Nadal, A. Low doses of the endocrine disruptor bisphenol A and the native hormone 17β-estradiol rapidly activate transcription factor CREB. FASEB J 2002;16:1671-1673..

Although the amount and duration of systemic BPA absorption that can produce adverse effects has not yet been established 1111. Fleisch, AF; Sheffield, PE; Chinn, C; Edelstein, BL; Landrigan PJ. Bisphenol A and related compounds in dental materials. Pedriatics 2010;126:760-768.,2121. Kloukos, D; Pandis, N; Eliades, T In vivo bisphenol-A release from dental pit and fissure sealants: a systematic review. J Dent 2013;41:659-667., it is known that BPA is released from dental resinous materials by the salivary enzymatic hydrolysis of its derivatives and it is detectable in saliva for up to 3 h after material placement in the mouth 2121. Kloukos, D; Pandis, N; Eliades, T In vivo bisphenol-A release from dental pit and fissure sealants: a systematic review. J Dent 2013;41:659-667.. Residual (uncured) BPA can be removed from the resin or sealant through chewing attrition or be degraded chemically or mechanically, and may be absorbed systemically 1010. Lang, IA; Galloway, TS; Scarlett, A; Henley, WE; Depledge M; Wallace RB et al.. Association of urinary bisphenol A concentration with medical disorders and laboratory abnormalities in adults. J Am Dent Assoc 2008;300:1303-1310.,2222. Kane, B; Karren, J; Garcia-Godoy, C; Garcia-Godoy, F. Sealant adaptation and penetration into occlusal fissures. Am J Dent 2009;22:89-91..

The successful clinical use of fissure sealants is attributed to their retention, resistance to wear and capacity to maintain an adequate seal on tooth surface 11. Prabhakar, AR; Murthy, SA; Sugandhan, S. Comparative evaluation of the length of resin tags, viscosity and microleakage of pit and fissure sealants - an in vitro scanning electron microscope study. Contemp Clin Dent 2011;2:324-330.. Previous studies have reported increased bond strengths after application of an adhesive layer between sealant and contaminated 44. Gomes-Silva, JM; Torres, CP; Contente, MMMG; Oliveira, MAHM; Palma-Dibb, RG; Borsatto, MC. Bond strength of a pit-and-fissure sealant associated to etch-and-rinse and self-etching adhesive systems to saliva-contaminated enamel: individual vs. simultaneous light curing. Braz Dent J 2008;19:341-347.,2323. Asselin, M-E; Sitbon, W; Fortin, D; Abelardo, L; Rompre PH. Bond strength of a sealant to permanent enamel: evaluation of 3 application protocols. Pediatr Dent 2009;31:323-328.cs,2424. Feigal, RJ; Musherure, P; Gillespie, B; Levy-Polack, M, Quelhas, I, Hebling, J. Improved sealant retention with bonding agents: a clinical study of two-bottle and single-bottle systems. J Dent Res 2000;79:1850-1856.,2525. Kang, JH; Kondo, F; Katayama, Y. Human exposure to bisphenol A. Toxicology 2006;226:79-89. and non-contaminated 2323. Asselin, M-E; Sitbon, W; Fortin, D; Abelardo, L; Rompre PH. Bond strength of a sealant to permanent enamel: evaluation of 3 application protocols. Pediatr Dent 2009;31:323-328.cs etched enamel, due to its hydrophilic property 2424. Feigal, RJ; Musherure, P; Gillespie, B; Levy-Polack, M, Quelhas, I, Hebling, J. Improved sealant retention with bonding agents: a clinical study of two-bottle and single-bottle systems. J Dent Res 2000;79:1850-1856.. A BPA-free fissure sealant moisture-tolerant product has been introduced under the trade name EmbraceTM WetBondTM (EWB; Pulpdent Corporation, Watertown, MA, USA), which good marginal adaptation in pits and fissures 2222. Kane, B; Karren, J; Garcia-Godoy, C; Garcia-Godoy, F. Sealant adaptation and penetration into occlusal fissures. Am J Dent 2009;22:89-91. and reduction of microbial attachment on sealant surface 2626. Sadeghi, M. An in vitro microleakage study of class V cavities restored with a new self-adhesive flowable composite resin versus different flowable materials. Dent Res J 2012;9:460-465..

Because research is limited to these tests and there is lack of information on the retention of EWB under dry conditions and salivary contamination to prove its effectiveness. The aim of this study was to evaluate the shear bond strength (SBS) of a EWB BPA-free sealant to saliva-contaminated and non-contaminated enamel with or without use of an intermediate adhesive layer underneath the sealant. The hypothesis was that there is no significant difference among the experimental conditions.

Material and Methods

After research protocol approval by the institutional Ethics Committee (Process #2010.1.539.58.0), freshly extracted sound human third molars were cleaned from calculus and root-adhered debris and examined under a ×20 magnifier to discard those with cracks and structural defects.

Sample size calculation was performed before the beginning of the study using the G Power 3.1.7 Version (Franz Faul, Universität Kiel, Germany) software for Windows XP. Expecting the minimum correlation of 0.60 with 0.80 power, 0.801 actual power and alpha of 0.05 and one-sided test, the minimum sample size was 15 samples.

Forty-five teeth were selected for the study and stored in 0.9% saline with 0.4% sodium azide at 4 °C. Prior to use, the teeth were washed in running water to eliminate storage solution residues. Roots were cut transversally 2 mm below the cementoenamel junction, crowns were bisected buccolingually and the resulting halves were embedded in polyester resin (2.1 cm diameter and 1.1 cm high). After resin polymerization, the mesial and distal enamel surfaces were ground wet with #320- to 400-grit silicon carbide (SiC) papers (Buehler Ltd., Lake Bluff, IL, USA), in a low-speed polishing machine (Aropol 2V; Arotec S/A, São Paulo, SP, Brazil). The specimens were hand polished with wet #600-grit SiC paper and cleaned with pumice slurry to obtain 90 flat, smooth test surfaces. The bonding site was delimited with an adhesive tape piece with a 3-mm-diameter central hole. The following materials were used: Fluroshield(tm) sealant (F; Dentsply/Caulk, Milford, DE, USA), Embrace(tm) WetBond(tm) (EWB, Pulpdent), Adper Single Bond adhesive system (SB; 3M ESPE, St. Paul, MN, USA). The 90 test specimens randomly assigned to 6 groups (n=15), as follows: F (control), EWB (control), SB/F, SB/EWB, s-SB/F, s-SB/EWB. In all groups, the enamel surfaces were etched with a 37% phosphoric acid gel (Scotchbond(tm) Etchant; 3M ESPE).

The specimens were individually fixed in a metallic clamping device and the test surfaces were pressed against a split polytetrafluoroethylene jig to provide a cylindrical cavity (4 mm high x 3 mm diameter) coincident with the delimited enamel bonding site. In groups s-SB/F and s-SB/EWB, acid-etched enamel was contaminated with 0.01 mL of fresh human saliva from a healthy donor for 20 s and the enamel surface was not dried. Sealant was inserted into the jig in two increments (2 mm high x 3 mm diameter), polymerized for 20 s each. As the cavity was filled, the specimen was released from the jig and clamping device, resulting in a sealant cylinder (4 mm x 3 mm) bonded to the enamel surface.

In groups SB/F, SB/EWB, s-SB/F and s-SB/EWB, the adhesive system was used before sealant placement. Disposable microbrush tips were used to avoid excess and pooling of adhesive along the edges of the adhesive tape, which could affect tension distribution during the shearing test and the validity of results. The adhesive system and the sealants were light-cured for 10 s and 20 s, respectively, with a halogen light-curing unit (XL 3000; 3M/ESPE) with 450 mW/cm2 output, as measured with a curing radiometer (Demetron Research Corp., Danbury, CT, USA).

After 24 h storage in distilled water at 37 °C, SBS was measured using a knife-edge blade in a universal testing machine (MEM 2000; EMIC Ltda, São José dos Pinhais, PR, Brazil) with a 50 kgf load cell at crosshead speed of 0.5 mm/min. The fractures were analyzed under a stereoscopic microscope (Nikon Instrument Group Inc. Melville, NY, USA) with 40× magnification in order to determine the types of fracture: adhesive, at the enamel interface/sealant or adhesive system; cohesive, in the body of the sealant or enamel, keeping an intact interface; and mixed when occurred disruption of the adhesive bond and the material or the substrate at the same time.

Means in MPa and standard deviations were calculated and analyzed regarding their distribution and homogeneity. Data were analyzed statistically by Kruskal-Wallis and Mann-Whitney tests using SPSS (SPSS 12.0 for Windows Inc., Chicago, IL, USA). Significance level was set at 5%.

Results

The F group presented significantly higher SBS (p<0.05) than the EWB group in all experimental conditions. Comparing the groups sealed with Fluroshield(tm), the SB/F group had the highest bond strength (p<0.05). The SB/EWB group presented significantly higher SBS than the EWB group, which had the lowest SBS of all groups (p<0.05). The use of an intermediate adhesive prior to application of Fluroshield(tm) increased significantly the SBS to dry enamel, which did not occur in the presence of salivary contamination. The SBS of EWB to both contaminated and non-contaminated enamel increased significantly when the sealant was combined with the adhesive system (Table 1).

Table 1
Shear bond strength means (MPa) of the fissure sealants with and without an intermediate adhesive layer under dry and saliva-contamination conditions

Failure mode analysis revealed a predominance of cohesive failures in SB/F (40%) and SB/EWB (66.6%) groups. Adhesive failures were prevalent in EWB (60%) and s-SB/F (53.3%) groups and mixed failures in F and s-SB/EWB groups, with 40% and 60%, respectively (Fig. 1).

Figure 1
Failure mode distribution in the groups after shearing test.

Discussion

The effectiveness of sealants as caries-preventive agents depends mainly on an adequate bonding of the sealant to the tooth surface and its complete retention on the tooth 99. Khatri, SG; Samuel,SR; Acharya, S; Patil, S; Madan, K. Retention of moisture-tolerant and conventional resin-based sealant in six- to nine-year-old children. Pediatr Dent 2015;37:366-370.. Sealant retention is often assessed by shear strength tests and the results are considered reliable and effective in comparative studies to determine the adhesion of materials to tooth structure 2727. Eliades, A; Birpou, E; Eliades, T; Eliades, G. Self-adhesive restoratives as pit and fissure sealants: A comparative laboratory study. Dent Mater 2013;29:752-762..

The resin-based sealant Fluroshield(tm) is the gold standard in sealant research due to its excellent shear test results 44. Gomes-Silva, JM; Torres, CP; Contente, MMMG; Oliveira, MAHM; Palma-Dibb, RG; Borsatto, MC. Bond strength of a pit-and-fissure sealant associated to etch-and-rinse and self-etching adhesive systems to saliva-contaminated enamel: individual vs. simultaneous light curing. Braz Dent J 2008;19:341-347., since the average range of bond strength was is accepted to be 5.9 to 7.8 MPa clinically and 4.9 MPa for laboratory performances 2424. Feigal, RJ; Musherure, P; Gillespie, B; Levy-Polack, M, Quelhas, I, Hebling, J. Improved sealant retention with bonding agents: a clinical study of two-bottle and single-bottle systems. J Dent Res 2000;79:1850-1856.. However, there are few studies testing EWB 99. Khatri, SG; Samuel,SR; Acharya, S; Patil, S; Madan, K. Retention of moisture-tolerant and conventional resin-based sealant in six- to nine-year-old children. Pediatr Dent 2015;37:366-370.,2222. Kane, B; Karren, J; Garcia-Godoy, C; Garcia-Godoy, F. Sealant adaptation and penetration into occlusal fissures. Am J Dent 2009;22:89-91.,2727. Eliades, A; Birpou, E; Eliades, T; Eliades, G. Self-adhesive restoratives as pit and fissure sealants: A comparative laboratory study. Dent Mater 2013;29:752-762.,2828. Iyer, RR; Gopalakrishnapillai, AC; Kalantharakath, T. Comparisons of in vitro penetration and adaptation of moisture tolerant resin sealant and conventional resin sealant in different fissure types. Chin J Dent Res 2013;16:127-136. and none has assessed sealant retention against shearing forces. Therefore a comparative analysis with the results of the present study cannot be done. Base don the findings, the null hypothesis could not be accepted.

Studies have shown that the SBS between sealant and enamel surface decreases significantly under conditions of salivary contamination 44. Gomes-Silva, JM; Torres, CP; Contente, MMMG; Oliveira, MAHM; Palma-Dibb, RG; Borsatto, MC. Bond strength of a pit-and-fissure sealant associated to etch-and-rinse and self-etching adhesive systems to saliva-contaminated enamel: individual vs. simultaneous light curing. Braz Dent J 2008;19:341-347.. Because of the high enamel reactivity induced by phosphoric acid etching, even minute exposures to saliva, as brief as 1 s, could be sufficient to create a pellicle that partially occludes the enamel pores, causing ultrastructural alterations and preventing formation of the resin tags responsible for mechanical retention 88. Hormati, AA; Fuller, JL; Denehy, GE. Effects of contamination and mechanical disturbance on the quality of acid-etched enamel. J Am Dent Assoc 1980;100:34-38.. The use of adhesive systems underneath sealant restorations has been suggested to minimize the deleterious effects of salivary contamination to adhesion 44. Gomes-Silva, JM; Torres, CP; Contente, MMMG; Oliveira, MAHM; Palma-Dibb, RG; Borsatto, MC. Bond strength of a pit-and-fissure sealant associated to etch-and-rinse and self-etching adhesive systems to saliva-contaminated enamel: individual vs. simultaneous light curing. Braz Dent J 2008;19:341-347.. It was significantly observed only for EWB sealant, which had a similar result when associated to adhesive without contamination. Fluroshield(tm) showed higher SBS means when it was associated with adhesive systems without contamination. This is likely due to the great capacity of single-bottle adhesives to flow deeply into capillary-like spaces of the etched enamel surface and produce an optimal resin tag penetration and enhanced adhesion 44. Gomes-Silva, JM; Torres, CP; Contente, MMMG; Oliveira, MAHM; Palma-Dibb, RG; Borsatto, MC. Bond strength of a pit-and-fissure sealant associated to etch-and-rinse and self-etching adhesive systems to saliva-contaminated enamel: individual vs. simultaneous light curing. Braz Dent J 2008;19:341-347..

The manufacturer states that EWB incorporates di-, tri- and multi-functional acrylate monomers into a hydrophilic, resin acid-integrating network. The sealant is activated in presence of moisture and is recommended for placement on slightly moist acid-etched enamel surfaces, which can form micromechanical and chemical bonds to slightly moist surfaces 99. Khatri, SG; Samuel,SR; Acharya, S; Patil, S; Madan, K. Retention of moisture-tolerant and conventional resin-based sealant in six- to nine-year-old children. Pediatr Dent 2015;37:366-370.. When activated, EWB is acidic, but the cured material has low water solubility and a neutral pH 2222. Kane, B; Karren, J; Garcia-Godoy, C; Garcia-Godoy, F. Sealant adaptation and penetration into occlusal fissures. Am J Dent 2009;22:89-91.. This could be the reason why EWB showed better results with the adhesive system. The hydrophilic monomers in the contemporary adhesive systems are known to increase the surface wetting and resin penetration 2424. Feigal, RJ; Musherure, P; Gillespie, B; Levy-Polack, M, Quelhas, I, Hebling, J. Improved sealant retention with bonding agents: a clinical study of two-bottle and single-bottle systems. J Dent Res 2000;79:1850-1856..

Although EWB may offer lower polymerization shrinkage due to the absence of BPA 2222. Kane, B; Karren, J; Garcia-Godoy, C; Garcia-Godoy, F. Sealant adaptation and penetration into occlusal fissures. Am J Dent 2009;22:89-91., epoxy resins are known to have an outstanding adhesive quality 2929. Bowen, RL. Use of epoxy resins in restorative materials. J Dent Res 1956;35:360-369., which could be an explanation for the remarkably low adhesion of EWB even to non-contaminated enamel, which had 60% of adhesive fractures. Thus, on one hand, BPA-free resinous dental materials may be advantageous for avoiding potential toxic effects to the patients 2525. Kang, JH; Kondo, F; Katayama, Y. Human exposure to bisphenol A. Toxicology 2006;226:79-89., but on the other hand. The absence of BPA may affect negatively the adhesion of materials to dental tissues 1111. Fleisch, AF; Sheffield, PE; Chinn, C; Edelstein, BL; Landrigan PJ. Bisphenol A and related compounds in dental materials. Pedriatics 2010;126:760-768.. In previous studies, EWB showed better adaptation compared to conventional sealants 99. Khatri, SG; Samuel,SR; Acharya, S; Patil, S; Madan, K. Retention of moisture-tolerant and conventional resin-based sealant in six- to nine-year-old children. Pediatr Dent 2015;37:366-370.,2828. Iyer, RR; Gopalakrishnapillai, AC; Kalantharakath, T. Comparisons of in vitro penetration and adaptation of moisture tolerant resin sealant and conventional resin sealant in different fissure types. Chin J Dent Res 2013;16:127-136.. In this study, EWB presented the lowest SBS means when used strictly following the manufacturer's instructions, compared to Fluroshield(tm). Although this study has not evaluated the morphology of the fissures, it may have affected the outcome, since it was found that cracks in V and U format featured the best penetrations and adaptations 2828. Iyer, RR; Gopalakrishnapillai, AC; Kalantharakath, T. Comparisons of in vitro penetration and adaptation of moisture tolerant resin sealant and conventional resin sealant in different fissure types. Chin J Dent Res 2013;16:127-136.. Third molars were used in this research, which have varied occlusal anatomy.

Further laboratory studies are required to confirm and explain the results of the present study as well as testing other mechanical properties of EWB to provide the scientific basis for its clinical indication. The combination of EWB with adhesive systems could improve the mechanical properties of the sealant with the benefit of not releasing BPA; however, in this study, the EWB did not produce good results for shear strength under any of the tested conditions.

It may be concluded that an adhesive system layer should be used prior to sealant placement, in both dry and saliva-contaminated enamel. F had the best performance in all experimental conditions.

References

  • 1
    Prabhakar, AR; Murthy, SA; Sugandhan, S. Comparative evaluation of the length of resin tags, viscosity and microleakage of pit and fissure sealants - an in vitro scanning electron microscope study. Contemp Clin Dent 2011;2:324-330.
  • 2
    Panigrahi, A; Srilatha, KT; Panigrahi, RG; Mohanty, S; Bhuyan, SK; Bardhan, D. Microtensile bond strength of Embrace WetBond hydrophilic sealant in different moisture contamination: an in-vitro study. J Clin Diagn Res 2015;9:ZC23-ZC25.
  • 3
    Simonsen, RJ; Neal, NC. A review of the clinical application and performance of pit and fissure sealants. Aust Dent J 2011;56:45-58.
  • 4
    Gomes-Silva, JM; Torres, CP; Contente, MMMG; Oliveira, MAHM; Palma-Dibb, RG; Borsatto, MC. Bond strength of a pit-and-fissure sealant associated to etch-and-rinse and self-etching adhesive systems to saliva-contaminated enamel: individual vs. simultaneous light curing. Braz Dent J 2008;19:341-347.
  • 5
    Waggoner, WF. Managing occlusal surfaces of young permanent molars. J Am Dent Assoc 1991;122:72-76.
  • 6
    Locke, D; Jokovic, A; Kay, EJ. Prevention. Part 8: The use of pit and fissure sealants in preventing caries in the permanent dentition of children. Br Dent J 2003;195:375-378.
  • 7
    Silverstone, LM; Hicks, MJ; Featherstone, MJ. Oral fluid contamination of etched enamel surfaces: an SEM study. J Am Dent Assoc 1985;110:329-332.
  • 8
    Hormati, AA; Fuller, JL; Denehy, GE. Effects of contamination and mechanical disturbance on the quality of acid-etched enamel. J Am Dent Assoc 1980;100:34-38.
  • 9
    Khatri, SG; Samuel,SR; Acharya, S; Patil, S; Madan, K. Retention of moisture-tolerant and conventional resin-based sealant in six- to nine-year-old children. Pediatr Dent 2015;37:366-370.
  • 10
    Lang, IA; Galloway, TS; Scarlett, A; Henley, WE; Depledge M; Wallace RB et al.. Association of urinary bisphenol A concentration with medical disorders and laboratory abnormalities in adults. J Am Dent Assoc 2008;300:1303-1310.
  • 11
    Fleisch, AF; Sheffield, PE; Chinn, C; Edelstein, BL; Landrigan PJ. Bisphenol A and related compounds in dental materials. Pedriatics 2010;126:760-768.
  • 12
    Timms, BG; Howdeshell, KL; Barton, L; Bradley, S; Richter CA; vom Saal FS. Estrogenic chemicals in plastic and oral contraceptives disrupt development of the fetal mouse prostate and urethra. Proc Natl Acad Sci USA 2005;102:7014-7019.
  • 13
    Sasco, AJ. Epidemiology of breast cancer: an environmental disease? APMIS 2001;109:321-332.
  • 14
    Palanza, P; Howdeshell, KL; Parmigiani, S; vom, Saad FS. Exposure to a low dose of bisphenol A during fetal life or in adulthood alters maternal behavior in mice. Environ Health Perspect 2002;110Suppl 3:415-422.
  • 15
    Alonso-Magdalena, P; Morimoto, S; Rípoli, C; Fuentes, E; Nadal, A. The estrogenic effect of bisphenol A disrupts the pancreatic β-cell function in vivo and induces insulin resistance. Environ Health Perspect 2006;114:106-112.
  • 16
    Bindhumol, V; Chitra, KC; Mathur, PP. Bisphenol A induces reactive oxygen species generation in the liver of male rats. Toxicology 2003;188:117-124.
  • 17
    Ropero, AB; Alonso-Magdalena, P; García-García ,E; Rípoli C; Fuentes E; Nadal A. Bisphenol A disruption of the endocrine pancreas and blood glucose homeostasis. Int J Androl 2008;31:194-200.
  • 18
    Moriyama, K; Tagami, T; Akamizu, T; Usui, T; Saijo, M; Kanamoto, N et al.. Thyroid hormone action is disrupted by bisphenol A as an antagonist. J Clin Endocrinol Metab 2002;87:5185-5190.
  • 19
    Ooe, H; Tkahiro, T; Iguchi-Ariga, SMM; Ariga, H. Induction of reactive oxygen species by bisphenol A and abrogation of bisphenol A induced cell injury by DJ-I. Toxicol Sci 2005;88:114-126.
  • 20
    Quesada, I; Fuentes, E; Viso-León, MC; Soria, B; Rípoli, C; Nadal, A. Low doses of the endocrine disruptor bisphenol A and the native hormone 17β-estradiol rapidly activate transcription factor CREB. FASEB J 2002;16:1671-1673.
  • 21
    Kloukos, D; Pandis, N; Eliades, T In vivo bisphenol-A release from dental pit and fissure sealants: a systematic review. J Dent 2013;41:659-667.
  • 22
    Kane, B; Karren, J; Garcia-Godoy, C; Garcia-Godoy, F. Sealant adaptation and penetration into occlusal fissures. Am J Dent 2009;22:89-91.
  • 23
    Asselin, M-E; Sitbon, W; Fortin, D; Abelardo, L; Rompre PH. Bond strength of a sealant to permanent enamel: evaluation of 3 application protocols. Pediatr Dent 2009;31:323-328.cs
  • 24
    Feigal, RJ; Musherure, P; Gillespie, B; Levy-Polack, M, Quelhas, I, Hebling, J. Improved sealant retention with bonding agents: a clinical study of two-bottle and single-bottle systems. J Dent Res 2000;79:1850-1856.
  • 25
    Kang, JH; Kondo, F; Katayama, Y. Human exposure to bisphenol A. Toxicology 2006;226:79-89.
  • 26
    Sadeghi, M. An in vitro microleakage study of class V cavities restored with a new self-adhesive flowable composite resin versus different flowable materials. Dent Res J 2012;9:460-465.
  • 27
    Eliades, A; Birpou, E; Eliades, T; Eliades, G. Self-adhesive restoratives as pit and fissure sealants: A comparative laboratory study. Dent Mater 2013;29:752-762.
  • 28
    Iyer, RR; Gopalakrishnapillai, AC; Kalantharakath, T. Comparisons of in vitro penetration and adaptation of moisture tolerant resin sealant and conventional resin sealant in different fissure types. Chin J Dent Res 2013;16:127-136.
  • 29
    Bowen, RL. Use of epoxy resins in restorative materials. J Dent Res 1956;35:360-369.

Publication Dates

  • Publication in this collection
    May-Jun 2016

History

  • Received
    23 Feb 2016
  • Accepted
    04 Apr 2016
Fundação Odontológica de Ribeirão Preto Av. do Café, S/N, 14040-904 Ribeirão Preto SP Brasil, Tel.: (55 16) 3602-3982, Fax: (55 16) 3633-0999 - Ribeirão Preto - SP - Brazil
E-mail: bdj@forp.usp.br