Open-access Comparative study of descendent colon rupture resistance considering traction force of rupture and total energy of rupture in rats

Estudo comparativo da resistência de ruptura de cólon descendente por meio de ensaio uniaxial força de ruptura à tração e energia total de ruptura em ratos

Abstracts

PURPOSE: To compare total energy of rupture and traction force of rupture tests within a rupture resistance study of descendent colon of rats. METHODS: Twelve descendent colon segments of rats were considered to perform the study. For each one of the specimens, total energy of rupture and traction force of rupture necessary to promote colic wall burst were evaluated through the biomechanical total energy of rupture test using the Biomechanical Data Acquisition and Analysis System, version 2.0. Average, standard deviation, standard error of average and coefficient of variation were considered for analysis of results. RESULTS: Traction force of rupture average, standard deviation, standard error of average and coefficient of variation were 380.05 gf, 98.74, 28.5 e 25.98%, respectively while total energy of rupture presented average of 244.85 gf, standard deviation of 57.76, standard error of average of 16.67 and coefficient of variation of 23.59. CONCLUSION: Although, total energy of rupture considered a larger number of attributes to its calculation related to non-linear viscoelastic materials, such as colic wall, it presented a smaller coefficient of variation when compared to traction force of rupture, thus demonstrating to constitute a possible parameter to analyze intestinal resistance of rats.

Biomechanics; Colon, Descending; Animal Experimentation


OBJETIVO: Comparação das grandezas físicas Energia Total de Ruptura e Força de Ruptura à Tração no estudo da resistência de ruptura do cólon descendente de ratos. MÉTODOS: Doze segmentos de cólon descendente de ratos foram utilizados como corpos de prova. Por meio do Teste Biomecânico Energia Total de Ruptura, obteve-se, de cada espécime, a Força de Ruptura à Tração e a Energia Total de Ruptura necessárias para promover o rompimento da parede cólica. Com esses valores, calculou-se a média, o desvio padrão, o erro padrão e o coeficiente de variação, sendo esse último atributo usado para a comparação das grandezas físicas. RESULTADOS: Os valores da média, do desvio-padrão, do erro-padrão e do coeficiente de variação da Força de Ruptura à Tração foram 380,05 gf, 98,74, 28,5 e 25,98%, respectivamente. A Energia Total de Ruptura apresentou a média de 244,85 gf, o desvio-padrão de 57,76, o erro padrão de 16,67 e o coeficiente de variação de 23,59%. CONCLUSÃO: A Energia Total de Ruptura, mesmo considerando em seus cálculos maior quantidade de atributos pertencentes aos materiais com propriedade viscoelástica não linear, tal qual a estrutura da parede cólica, apresentou menor coeficiente de variação em comparação com o coeficiente de variação da Força de Ruptura à Tração, demonstrando ser um possível parâmetro para a análise da resistência intestinal de ratos.

Biomecânica; Cólon Descendente; Experimentação animal


ORIGINAL ARTICLE

Comparative study of descendent colon rupture resistance considering traction force of rupture and total energy of rupture in rats1

Estudo comparativo da resistência de ruptura de cólon descendente por meio de ensaio uniaxial força de ruptura à tração e energia total de ruptura em ratos

Feng Chung WuI; Huei Diana LeeII; Maksoel Algustin Krauspenhar NizIII; Maria de Loudes Setsuko AyrizonoIV; Cláudio Saddy Rodrigues CoyV; Juvenal Ricardo Navarro GóesVI; João José FagundesV

IPhD, Research Assistant Professor of the Department of Surgery – Coloproctology Service, Faculty of Medical Sciences, UNICAMP. Researcher of the Institute of Automation Technology and Informatics – ITAI. Assistant Professor of the Computer Science Course at the State University of West Paraná – UNIOESTE, Brazil

IIPhD, Assistant Professor of the Computer Science Course and Coordinator of the Bioinformatics Laboratory – LABI, UNIOESTE, Brazil

IIITrainee at the Bioinformatics Laboratory – LABI, UNIOESTE, Brazil

IVPhD, Department of Surgery – Coloproctology Service, Faculty of Medical Sciences, UNICAMP, Brazil

VPhD, Assistant Professor of the Department of Surgery – Coloproctology Service, Faculty of Medical Sciences, UNICAMP, Brazil

VIPhD, Associate Professor of the Department of Surgery, Chair of the Department of Surgery and Head of the Coloproctology Service, Faculty of Medical Sciences, UNICAMP, Brazil

Correspondence Correspondence: Bioinformatics Laboratory – LABI State University of West Paraná – UNIOESTE Rua Tarqüínio Joslin dos Santos, 1300 85870-650 Foz do Iguaçu – Paraná Brazil Phone: (55 45)3520-5917 Fax: (55 45)3522-3462 wufc@unioeste.br

ABSTRACT

PURPOSE: To compare total energy of rupture and traction force of rupture tests within a rupture resistance study of descendent colon of rats.

METHODS: Twelve descendent colon segments of rats were considered to perform the study. For each one of the specimens, total energy of rupture and traction force of rupture necessary to promote colic wall burst were evaluated through the biomechanical total energy of rupture test using the Biomechanical Data Acquisition and Analysis System, version 2.0. Average, standard deviation, standard error of average and coefficient of variation were considered for analysis of results.

RESULTS: Traction force of rupture average, standard deviation, standard error of average and coefficient of variation were 380.05 gf, 98.74, 28.5 e 25.98%, respectively while total energy of rupture presented average of 244.85 gf, standard deviation of 57.76, standard error of average of 16.67 and coefficient of variation of 23.59.

CONCLUSION: Although, total energy of rupture considered a larger number of attributes to its calculation related to non-linear viscoelastic materials, such as colic wall, it presented a smaller coefficient of variation when compared to traction force of rupture, thus demonstrating to constitute a possible parameter to analyze intestinal resistance of rats.

Key words: Biomechanics. Colon, Descending. Animal Experimentation.

RESUMO

OBJETIVO: Comparação das grandezas físicas Energia Total de Ruptura e Força de Ruptura à Tração no estudo da resistência de ruptura do cólon descendente de ratos.

MÉTODOS: Doze segmentos de cólon descendente de ratos foram utilizados como corpos de prova. Por meio do Teste Biomecânico Energia Total de Ruptura, obteve-se, de cada espécime, a Força de Ruptura à Tração e a Energia Total de Ruptura necessárias para promover o rompimento da parede cólica. Com esses valores, calculou-se a média, o desvio padrão, o erro padrão e o coeficiente de variação, sendo esse último atributo usado para a comparação das grandezas físicas.

RESULTADOS: Os valores da média, do desvio-padrão, do erro-padrão e do coeficiente de variação da Força de Ruptura à Tração foram 380,05 gf, 98,74, 28,5 e 25,98%, respectivamente. A Energia Total de Ruptura apresentou a média de 244,85 gf, o desvio-padrão de 57,76, o erro padrão de 16,67 e o coeficiente de variação de 23,59%.

CONCLUSÃO: A Energia Total de Ruptura, mesmo considerando em seus cálculos maior quantidade de atributos pertencentes aos materiais com propriedade viscoelástica não linear, tal qual a estrutura da parede cólica, apresentou menor coeficiente de variação em comparação com o coeficiente de variação da Força de Ruptura à Tração, demonstrando ser um possível parâmetro para a análise da resistência intestinal de ratos.

Descritores: Biomecânica. Cólon Descendente. Experimentação animal.

Introduction

The intrinsic resistance of the colic wall has been focus of research with the objective of inferring, through its measurement, the efficiency of the intestinal healing. Many biomechanical tests, based on different physic-mechanical concepts, are used to achieve this purpose. Nevertheless, the most frequently used essays, for example, traction force1,2, explosion pressure3 and tension preassure4,5 do not consider in their calculations fundamental attributes from biological materials such as elongation, elasticity, plastic-elastic deformation and rupture time. In fact, these essays evaluate partially the colic segments behavior which present viscoelastic non-linear properties6,7. With the aim of including these attributes into the analysis, it was developed the Total Energy of Rupture test (ETR) based on the Universal Principle of Energy Conservation. This biomechanical test permits the mathematical analysis of the inherent properties of the intestinal segments after their submission to a variable force with the time8. In this work a comparative study between the physical largeness of Traction of Rupture, which presents uniaxial characteristic, and Total Energy of Rupture is proposed.

Methods

The Committee of Ethics in Animal Experimentation CEEA-IB-UNICAMP, approved procedures performed within this work according to the ethical principles adopted by the Brazilian College of Animal Experimentation – COBEA (Protocol n° 598-1). Twelve male Wistar rats were obtained from the Bioterism Center – CEMIB/UNICAMP, weighing 300-350 grams raised under similar conditions. Each animal provided a four-centimeter proof body of descendent colon. These specimens were submerged into a Becker cup containing a 0.9% physiologic solution at 37-centigrade degrees and papaverine chloridrate at a 250 milligrams per liter concentration. This procedure was performed with the purpose of minimizing spasms caused by the manipulation of the colon segments. After 30 minutes, these segments were taken out of solution and were submitted to the Total Energy of Rupture biomechanical test. This test is composed by the following components (Figure 1):


  1. Proof body (descendent colon segment) (

    Figure 1-a);

  2. Precision balance Mettler-Toledo SB8000 (

    Figure 1-b);

  3. Strength cell from the precision balance Mettler-Toledo SB8000 (

    Figure 1-c);

  4. Serial port from the precision balance Mettler-Toledo SB8000 (

    Figure 1-d);

  5. Traction system B.BRAUN 871.012 (

    Figure 1-e);

  6. Serial communication cable (

    Figure 1-f);

  7. Personal Computer with serial interface RS232 and the Biomechanical Data Acquisition and Analysis System, version 2.0 (SABI 2.0) (

    Figure 1-g);

  8. Polygraph Siemens-Elema/Modelo 804 Mingograft (

    Figure 1-h);

  9. Catheter Cannon nº 18 with the light closed (

    Figure 1-i);

  10. Catheter Cannon nº 18 with the light open (

    Figure 1-j);

  11. Triple-via plug attached at the supporter (

    Figure 1-k);

  12. Plastic syringe (10 ml), placed at the polygraph transducer (

    Figure 1-l).

ETR test was performed following the protocol described by WU et al.8. The force generated by the traction system was transferred to the specimen and detected by the precision balance strength cell. The computer containing SABI 2.0 received the force values, at a rate of three packages of data per second, sent by the balance. This system, in real time, draws the graph of the function Force x Elongation and, at the intestinal segment rupture moment, determines the Traction Force of Rupture value (FTR). SABI 2.0 automatically calculates the delimited area under this function through numerical integration using the Trapezoidal Rule method. This area corresponds to the Total Energy of Rupture (Figure 2)(Equation 1). A constant velocity of one centimeter per minute was maintained during the essay.


Where l represents the maximal elongation, l0 the initial length, F(x) the force corresponding to the elongation x and x the elongation which varies from l0 to l.

Both Rupture Force and Total Energy of Rupture were obtained for each specimen through the ETR biomechanical test. Average, standard deviation, standard error of the average and variation coefficient of these two physical largeness were calculated and used for comparison.

Results

FRT and ETR values for each rat as well as average, standard deviation, standard error of the average and the variation coefficient from these physical largeness are presented at Table 1.

Discussion

Severe problems are caused by the extravasation of the colic intraluminal content into the abdominal cavity leading to expressive indexes of morbidity and mortality1,2,3,4,5,9. Due to this fact, researchers have developed and applied different experimental models based on distinct physical-mechanical concepts with the aim to evaluate the intrinsic resistance of the intestinal wall when it is submitted to some kind of physical largeness1-11. The most used biomechanical essays are Traction Force of Rupture, Distension Pressure of Rupture using Liquid or Air and Tension of Rupture. On the one hand uniaxial tests, for example Traction Force of Rupture2,5 and Distension Pressure of Rupture3,4,10, and biaxial tests, such as Tension of Rupture2 and Final Resultant Tension of Rupture5, analyze partially the intestinal wall resistance properties, as these biological materials present non-linear viscoelastic properties. Therefore, essential attributes like deformation, time of rupture and elasticity module are not taken into account to calculate these physical largeness6,12.

On the other hand, it is believed that the Total Energy of Rupture, which corresponds to the accumulated inner energy necessary to promote the rupture of the intestinal loop, is able to analyze the resistance of intestinal segments. The Total Energy of Rupture is based on the Universal Principle of Energy Conservation and is obtained by applying the biomechanical ETR test, which considers for its calculation fundamental attributes and concepts related to the intestinal structure7,8. The ETR test, by means of SABI 2.0, draws in real time, the Force x Elongation function. As a consequence, at the rupture moment, the maximal force corresponds to the Traction Force of Rupture while the area under this function (Force x Elongation) represents the Total Energy of Rupture, which is automatically calculated by SABI 2.0. Physical largeness of FRT and ETR were measured for each proof body which were considered for a unique biomechanical essay. ETR and FRT are measured in different units, gram-force per centimeter (gf.cm) and gram-force (gf), respectively. Hence, the variation coefficient, which does not depend on the unit of the measure, as it is numerically expressed through the division of the standard deviation by the average, was used to promote the comparison between both physical largeness. It permits the comparison of data dispersion, i.e., the smaller the variation coefficient the more homogeneous is the sample13. In this work, FRT and ETR were calculated considering the same proof bodies and showed similar homogeneity, presenting respectively variation coefficients of 25.98 and 23.29%. Thus ETR exhibited a 2% smaller value than FRT. Nevertheless, the Total Energy of Rupture, when compared to the FRT, considers a larger number of attributes for its calculation that pertain to materials with non-linear viscoelastic properties, therefore demonstrating to be a possible parameter to analyze the intestinal resistance of rats. Future studies shall include the evaluation of samples containing a larger amount of specimens and also the evaluation of other tissues that present non-linear viscoelastic properties.

Conclusion

In this study, the Total Energy of Rupture (ETR) presented a variation coefficient similar to the variation coefficient of Traction Force of Rupture (FRT), though ETR considers for its calculation a larger number of attributes that are related to materials with non-linear viscoelastic properties such as the structure of the colic wall.

Acknowledgments

To Ana Cristina de Moraes and William Adalberto Silva from the Medicine and Experimental Surgery Center (NMCE), University of Campinas (UNICAMP) for technical support.

Received: October 11, 2005

Review: November 10, 2005

Accepted: December 12, 2005

Conflict of interest: none

Financial source:

Instituto de Tecnologia em Informática e Automação/ITAI

How to cite this article: Wu FC, Lee HD, Niz MAK, Ayrizono MLS, Coy CSR, Góes JRN, Fagundes JJ. Comparative study of descendent colon rupture resistance considering traction force of rupture and total energy of rupture in rats. Acta Cir Bras. [serial on the Internet] 2006 Mar-Apr;21(2). Available from URL: http://www.scielo.br/acb

References

  • 1. Hermann JB, Woodward SC, Pulaski EJ. Healing of colonic anastomoses in the rat. Surg Gynecol Obstet. 1964;119:169-75.
  • 2. Jiborn H, Ahonem J, Zederfeldt B. Healing of experimental colonic anastomoses. II. Breaking strength of the colon after left colon resection and anastomosis. Am J Surg. 1978;136:595-9.
  • 3. Wu FC, Ayrizono MLS, Fagundes JJ, Coy CSR, Góes JRN, Leonardi LS. Estudos biomecânicos da ação de aderências sobre anastomose cólica: trabalho experimental em ratos. Acta Cir Bras. 2003;18(3):216-23.
  • 4. Aprilli F, Guimarães AS, Rocha JJR. Anastomoses intestinais. In: Silva Jr., O.C. Modelos experimentais de pesquisa em cirurgia. 1ed. São Paulo: Robe Editorial; 1998.
  • 5. Wu FC. Estudo da ação de aderências sobre anastomose cólica: trabalho experimental em ratos [Dissertação Mestrado]. Faculdade de Ciências Médicas da UNICAMP; 2000.
  • 6. Fung YC. Biomechanics - Mechanical properties of soft living tissues. 2ed. New York: Spring-Verlag Inc; 1993.
  • 7. Wu FC. Estudo dos efeitos de diferentes concentrações de oxigênio e da hiperoxigenação hiperbárica sobre anastomoses cólicas comprometidas ou não pela isquemia: trabalho experimental em ratos [Tese Doutorado]. Faculdade de Ciências Médicas da UNICAMP; 2003.
  • 8. Wu FC, Lee HD, Machado RB, Dalmas S, Coy CSR, Góes JRN, Fagundes JJ. Apresentação do teste energia total de ruptura para avaliação de material biológico com propriedade viscoelástico não-linear. Acta Cir Bras. 2004;19(6):609-16.
  • 9. Fagundes JJ. Estudo comparativo da cicatrização de anastomoses cólicas realizadas com auxílio do bisturi laser de dióxido de carbono: trabalho experimental em cães [Tese Doutorado]. Faculdade de Ciências Médicas da UNICAMP; 1999.
  • 10. Hendricks T, Mastboom WJB. Healing of experimental intestinal anastomosis. Parameters for repairs. Dis Colon Rectum. 1990;33:891-901.
  • 11. Souza Filho ZA, Ioshii SO, Greca FH, Biondo-Simões, MLP, Rocha SL, Duda JR, Oliveira Filho HR. Emprego da submucosa de intestino delgado porcina no reparo de lesões do esôfago cervical. Estudo experimental em cães. Acta Cir Bras. 2003;18(3):224-31.
  • 12. Jamison CE, Marangoni RD, Glaser AA. Viscoelastic properties of soft tissue by discrete model characterization. J Biomechanics. 1968;1:3346.
  • 13. Freedman D, Pisani R, Purves R. Statistics. 3ed. New York: W.W. Norton & Company, Inc., 1998.
  • Correspondence:
    Bioinformatics Laboratory – LABI
    State University of West Paraná – UNIOESTE
    Rua Tarqüínio Joslin dos Santos, 1300
    85870-650 Foz do Iguaçu – Paraná Brazil
    Phone: (55 45)3520-5917 Fax: (55 45)3522-3462
  • 1
    . Study performed at the Coloproctology Service at the Surgical Techniques Laboratory from the Medicine and Experimental Surgery Center–NMCE, University of Campinas – UNICAMP, Brazil.
  • Publication Dates

    • Publication in this collection
      21 Mar 2006
    • Date of issue
      Apr 2006

    History

    • Reviewed
      10 Nov 2005
    • Received
      11 Oct 2005
    • Accepted
      12 Dec 2005
    location_on
    Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia https://actacirbras.com.br/ - São Paulo - SP - Brazil
    E-mail: actacirbras@gmail.com
    rss_feed Acompanhe os números deste periódico no seu leitor de RSS
    Acessibilidade / Reportar erro