Acessibilidade / Reportar erro

Comparative study of computerized and conventional electrocardiography in Quarter Horse and Mangalarga Marchador

Computerized electrocardiography has been gaining space in clinic routines because it is more practical and precise when compared to the conventional method. However, their reference values may differ from each other. The aim of this paper was to analyze and compare computerized and conventional electrocardiography in horses. Differences were observed between P wave amplitude (P<0001) with a mean of 0.21mV in the conventional method and 0.17mV in the computerized method, PR interval duration (p=0.0005) with a mean of 260.49 ms and 242.37 ms in the conventional and computerized methods respectively, and QRS complex duration (p=0.0003) with a mean of 75.61 ms in the conventional method and 84.83 ms in the computerized method. These differences should be taken into consideration in order to avoid misunderstandings in the interpretation of the electrocardiogram in equine species.

horses digital electrocardiography; cardiac electrical impulse


Universidade Federal de Minas Gerais, Escola de Veterinária Caixa Postal 567, 30123-970 Belo Horizonte MG - Brazil, Tel.: (55 31) 3409-2041, Tel.: (55 31) 3409-2042 - Belo Horizonte - MG - Brazil