Acessibilidade / Reportar erro

Evaluation of the cut quality of the Masyk® microkeratome in obtaining corneal flap from porcine eyes

PURPOSE: Evaluation of the cut quality of the Masyk® microkeratome in obtaining corneal flap from porcine eyes. METHODS: Prospective study with 31 porcine eyes divided into two groups: 15 eyes with programmed flap thickness of 160 µm and 9.5 mm diameter (Group 1), and 16 eyes with programmed flap thickness of 140 µm and 8.5 mm diameter (Group 2). Corneal thickness was calculated with a P55 pachymeter (Paradigm, USA) and the diameter with compass. RESULTS: No complications were observed during the use of the microkeratome. In group 1, the central corneal thickness mean was 146.33 ± 15.43 µm, range between 127 and 186 µm, and the vertical diameter mean was 9.39 ± 0.26 mm, range from 8.90 to 9.85 mm. In group 2, the central corneal thickness mean was 128.75 ± 18.83 µm, range from 71 to 178 µm, and the vertical diameter mean was 8.27 ± 0.20 mm, range from 7.95 to 8.65 mm. CONCLUSION: The Masyk® microkeratome showed to be effective and safe to produce corneal flaps with appropriate thickness and diameter in porcine eyes.

Keratomileusis, laser in situ; Keratectomy, photorefractive, excimer laser; Cornea; Microsurgery


Conselho Brasileiro de Oftalmologia Rua Casa do Ator, 1117 - cj.21, 04546-004 São Paulo SP Brazil, Tel: 55 11 - 3266-4000, Fax: 55 11- 3171-0953 - São Paulo - SP - Brazil
E-mail: abo@cbo.com.br