Acessibilidade / Reportar erro

Evaluation of coagulation/flocculation process in the landfill leachate treatment at the Municipal Wastewater Treatment Plant

Avaliação do processo de coagulação / floculação no tratamento de lixiviados de aterro sanitário em estação de tratamento de águas residuais

Abstracts

The combined treatment of leachate from urban solid waste landfills in a Municipal Wastewater Treatment Plant (MWTP) minimizes the implementation and operation costs of a landfill. This work investigated the combined treatment of the leachate from Morro do Céu Landfill in Niterói, RJ and sewage samples from Icaraí MWTP with different proportions (0, 0.5, 2.0 and 5.0 %). This MWTP features a physical chemical treatment followed by expulsion through a submarine emissary, and so the physical chemical treatment was simulated. The coagulants used were ferric chloride, aluminum sulfate, Tanfloc SG, Tanfloc SL and PanflocTM Hiper Plus in different concentrations (20, 40 and 60 mg L-1). During testing, polyelectrolytes in concentrations of 0.5 and 1.0 mg L-1 were added in some samples to stimulate flocculation. The statistical analysis of COD removals showed that Tanfloc SG achieved better results than the other coagulants in all conditions studied, without requiring the addition of polyelectrolytes. Toxicity tests were performed on the raw sewage with a mixture of 5.0 % of landfill leachate and in the mixture treated with Tanfloc SG. The results indicated that the toxicity of the samples is lower than the limit established by current Rio de Janeiro State legislation (NT-213, INEA).

physical-chemical treatment; sewage; toxicity


O tratamento combinado de lixiviado de aterros de resíduos sólidos urbanos em uma Estação de Tratamento de Esgotos Sanitários (ETE) é um procedimento que tem sido aplicado para minimizar os custos de implementação e operação de um aterro sanitário. Neste trabalho, o tratamento combinado de lixiviado oriundo do Aterro do Morro do Céu, Niterói, RJ, com esgoto doméstico, oriundo da ETE Icaraí, em diferentes proporções (0, 0,5, 2,0 e 5,0 %) foi realizado. Esta ETE apresenta um tratamento físico-químico e posterior lançamento em emissário submarino, dessa maneira o presente trabalho simulou o tratamento físico-químico realizado na ETE. Os coagulantes utilizados foram o cloreto férrico, sulfato de alumínio, Tanfloc SG, Tanfloc SL e Panfloc Hiper Plus® em diferentes concentrações (20, 40 e 60 mg L-1). Em alguns ensaios, polieletrólitos foram adicionados como auxiliares de floculação, em concentrações de 0,5 e 1,0 mg L-1. A análise estatística de remoções de DQO mostrou que Tanfloc SG obteve os melhores resultados do que os outros coagulantes em todas as condições estudadas, sem necessidade de adição de polieletrólitos. Os testes de toxicidade foram conduzidos com a mistura de 5,0 % de lixiviado em esgoto bruto e na mistura tratada com Tanfloc SG. Os resultados indicaram que a toxicidade das amostras é inferior ao limite estabelecido pela legislação em vigor no Rio de Janeiro (NT-213, INEA).

tratamento físico-químico; esgoto doméstico; toxicidade


  • ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS - ABNT. Technical Standard NBR 15.088 Aquatic Ecotoxicology - test method with fish. Rio de Janeiro, 2004.
  • AMERICAN PUBLICA HEALTH ASSOCIATION - APHA; AMERICAM WATER WORKS ASSOCIATION - AWWA; WATER POLLUTION CONTROL FACILITY - WPCF. Standard methods for examination of water and wastewater 21th ed. New York, 2005. 1055p.
  • CAMPOS, J. C.; MOURA, D.; COSTA, A. P.; YOKOYAMA, L.; ARAUJO, F. V. F.; CAMMAROTA, M. C. et al. Evaluation of pH, alkalinity and temperature during air stripping process for ammonia removal from landfill leachate, Journal of Environmental Science and Health, Part A: Toxic/Hazardous Substances and Environmental Engineering, v. 48, n. 9, p. 1105-1113, 2013. http://dx.doi.org/10.1080/10934529.2013.774658
  • CASTILHOS JR., A. B. (Coord). Gerenciamento de resíduos sólidos urbanos com ênfase na Proteção de corpos d'água: prevenção, geração e tratamento de lixiviados de aterros sanitários. Prosab 4. Petrópolis: Sermograf, 2006. 494p.
  • COSSU, R.; LAVAGNOLO, M. C.; ANDREOTTOLA, G. Biological removal of nutrients in co-treatment of leachate and sewage. In: INTERNATIONAL TRAINING SEMINAR: MANAGEMENT AND TREATMENT OF MSW LANDFILL LEACHATE, 1998, Venice. Proceedings... Cagliari: CISA, 1998. p. 1-13.
  • DIAMADOPOULOS, E.; SAMARAS , P.; DABOU, X.; SAKELLAROPOUL , D. P. Combined treatment of landfill leachate and domestic sewage in a sequencing batch reactor. Water Science & Technology, v. 36, p. 61-68, 1997. http://dx.doi.org/10.1016/S0273-1223(97)00370-3
  • EBERT, R. Estudo de regulamentos para recebimento de efluentes não domésticos no sistema público de esgotos. In: CONGRESSO BRASILEIRO DE ENGENHARIA SANITÁRIA E AMBIENTAL, 20., 1999, Rio de Janeiro. Anais... Rio de Janeiro: ABES, 1999.
  • EHRIG, H. J. Co-treatment in domestic sewage facilities. In: INTERNATIONAL TRAINING SEMINAR: MANAGEMENT AND TREATMENT OF MSW LANDFILL LEACHATE, 1998, Venice. Proceedings... Cagliari: CISA, 1998. p. 1-10.
  • INSTITUTO BRASILEIRO DE GEOGRAFIA E ESTATÍSTICA - IBGE. Pesquisa nacional de saneamento básico 2010. Available in http://www.ibge.gov.br/home/estatistica/populacao/condicaodevida/pnsb2008/PNSB_2008.pdf Access: 8 Sep. 2013.
  • INSTITUTO ESTADUAL DO AMBIENTE - INEA. Rio de Janeiro. NT-213, aprovada pela Deliberação CECA nº 1.948 de 04 de setembro de1990. Critérios e padrões para controle de toxicidade em efluentes líquidos industriais. Diário Oficial [do] Estado do Rio de Janeiro, Rio de Janeiro, 18 de outubro de 1990.
  • JORDÃO, E. P.; PESSÔA, C. A. Tratamento de esgotos domésticos 5. ed. Rio de Janeiro: ABES, 2009. 941p.
  • MANNARINO, C. F.; FERREIRA, J. A.; MOREIRA, J. C.; BILA, D. M.; MAGALHÃES, D. P. Assessment of combined treatment of landfill urban solid waste leachate and sewage using Danio rerio and Daphnia similis Bulletin of Environmental Contamination and Toxicology, v. 85, p. 274-278, 2010. http://dx.doi.org/10.1007/s00128-010-0087-9
  • MARTTINEN, S. K.; KETTUNEN, R. H.; RINTALA, J. A. Occurrence and removal of organic pollutants in sewages and landfill leachates. The Science of the Total Environmental, v. 301, p. 1-12, 2003. http://dx.doi.org/10.1016/S0048-9697(02)00302-9
  • QASIM, S.; CHIANG, W. Sanitary landfill leachate. Lancaster: Technomic Publishing Company, 1994.
  • RIO DE JANEIRO (Estado). Lei n. 2.661, de 27 de dez. de 1996 Regulamenta o disposto no art. 274 (atual 277) da constituição do Estado do Rio de Janeiro no que se refere à exigência de níveis mínimos de tratamento de esgotos sanitários, antes de seu lançamento em corpos d'água e dá outras providências. Available in: <http://alerjln1.alerj.rj.gov.br/CONTLEI.NSF/c8aa0900025feef6032564ec0060dfff/5a35845b2e69709d032564fb005de9a4?OpenDocument>. Access in: 8 Sep. 2013.

Publication Dates

  • Publication in this collection
    22 Jan 2014
  • Date of issue
    Dec 2013

History

  • Received
    09 Sept 2013
  • Accepted
    22 Oct 2013
Instituto de Pesquisas Ambientais em Bacias Hidrográficas Instituto de Pesquisas Ambientais em Bacias Hidrográficas (IPABHi), Estrada Mun. Dr. José Luis Cembranelli, 5000, Taubaté, SP, Brasil, CEP 12081-010 - Taubaté - SP - Brazil
E-mail: ambi.agua@gmail.com