Abstracts
Apnea test is a crucial requirement for determining the diagnosis of brain death (BD). There are few reports considering clinical complications during this procedure. We describe a major complication during performing the apnea test. We also analyse their practical and legal implications, and review the complications of this procedure in the literature. A 54 year-old man was admitted for impaired consciousness due to a massive intracerebral hemorrhage. Six hours later, he had no motor response, and all brainstem reflexes were negative. The patient fulfilled American Academy of Neurology (AAN) criteria for determining BD. During the apnea test, the patient developed pneumothorax, pneumoperitoneum, and finally cardiac arrest. Apnea test is a necessary requirement for the diagnosis of brain death. However, it is not innocuous and caution must be take in particular clinical situations. Complications during the apnea test could be more frequent than reported and may have practical and legal implications. Further prospective studies are necessary to evaluate the frequency and nature of complications during this practice.
apnea test; brain death; pneumoperitoneum; pneumothorax; complications
El test de apnea (AT) es un requerimiento esencial para el diagnóstico de muerte encefálica. Hay pocos estudios que consideren complicaciones clínicas relacionadas con este procedimiento. Describimos un paciente que desarrolló una complicación mayor mientras se efectuaba el test de apnea. Realizamos una revisión de las complicaciones relacionadas con este procedimiento en la literatura. CASO CLÍNICO: Un hombre de 54 años fue admitido por deterioro del sensorio debido a una hemorragia intracerebral. Seis horas posteriores, el paciente no tenía respuesta motora, y todos los reflejos del tronco cerebral estaban abolidos. El paciente cumplía con los criterios diagnósticos de Muerte Encefálica de acuerdo a lo establecido por la Academia Americana de Neurología. Durante el test de apnea, el paciente desarrolla súbitamente pneumotorax, pneumoperitoneo, y finalmente paro cardíaco. CONCLUSIÓN: El test de apnea es un requerimiento necesario para determinar el diagnóstico de muerte encefálica. No obstante, no es un procedimiento inocuo. Complicaciones durante este procedimiento pueden ser mas frecuentes que lo reportado en la literatura y tiene implicancias prácticas y legales.
test de apnea; muerte cerebral; pneumoperitoneo; pneumotorax; complicaciones
PNEUMOTHORAX AND PNEUMOPERITONEUM DURING THE APNEA TEST
HOW SAFE IS THIS PROCEDURE?
GUSTAVO SAPOSNIK* * MD, Department of Organ and Tissue Procurement and Ablation. Garrahan Hospital, Buenos Aires, Argentina. Aceite: 9-junho-2000. , GRACIELA RIZZO* * MD, Department of Organ and Tissue Procurement and Ablation. Garrahan Hospital, Buenos Aires, Argentina. Aceite: 9-junho-2000. , JORGE L. DELUCA* * MD, Department of Organ and Tissue Procurement and Ablation. Garrahan Hospital, Buenos Aires, Argentina. Aceite: 9-junho-2000.
ABSTRACT - Apnea test is a crucial requirement for determining the diagnosis of brain death (BD). There are few reports considering clinical complications during this procedure. We describe a major complication during performing the apnea test. We also analyse their practical and legal implications, and review the complications of this procedure in the literature. A 54 year-old man was admitted for impaired consciousness due to a massive intracerebral hemorrhage. Six hours later, he had no motor response, and all brainstem reflexes were negative. The patient fulfilled American Academy of Neurology (AAN) criteria for determining BD. During the apnea test, the patient developed pneumothorax, pneumoperitoneum, and finally cardiac arrest. Apnea test is a necessary requirement for the diagnosis of brain death. However, it is not innocuous and caution must be take in particular clinical situations. Complications during the apnea test could be more frequent than reported and may have practical and legal implications. Further prospective studies are necessary to evaluate the frequency and nature of complications during this practice.
KEY WORDS: apnea test, brain death, pneumoperitoneum, pneumothorax, complications.
Pneumotorax y pneumoperitoneo durante el test de apnea: cuán seguro es este procedimiento?
RESUMEN - El test de apnea (AT) es un requerimiento esencial para el diagnóstico de muerte encefálica. Hay pocos estudios que consideren complicaciones clínicas relacionadas con este procedimiento. Describimos un paciente que desarrolló una complicación mayor mientras se efectuaba el test de apnea. Realizamos una revisión de las complicaciones relacionadas con este procedimiento en la literatura. CASO CLÍNICO: Un hombre de 54 años fue admitido por deterioro del sensorio debido a una hemorragia intracerebral. Seis horas posteriores, el paciente no tenía respuesta motora, y todos los reflejos del tronco cerebral estaban abolidos. El paciente cumplía con los criterios diagnósticos de Muerte Encefálica de acuerdo a lo establecido por la Academia Americana de Neurología. Durante el test de apnea, el paciente desarrolla súbitamente pneumotorax, pneumoperitoneo, y finalmente paro cardíaco. CONCLUSIÓN:El test de apnea es un requerimiento necesario para determinar el diagnóstico de muerte encefálica. No obstante, no es un procedimiento inocuo. Complicaciones durante este procedimiento pueden ser mas frecuentes que lo reportado en la literatura y tiene implicancias prácticas y legales.
PALABRAS CLAVE: test de apnea, muerte cerebral, pneumoperitoneo, pneumotorax, complicaciones.
During decades, death has been defined as asystole and cessation of respiration. Brain death (BD) is the irreversible cessation of all functions of the entire brain, including the brainstem. Several criteria have been used to define this condition, differing in the ancillary method requirements and the time necessary to confirm the BD diagnosis. The most widely accepted criteria are the guidelines of the American Academy of Neurology (AAN) for determining brain death, which include: unresponsiveness or coma, absence of brainstem reflexes, and apnea.1 The apnea test (AT) is a necessary requirement to establish the diagnosis of BD. There are few reports describing complications during this procedure2-4.
We report a patient who developed pneumoperitoneum and pneumothorax during the apnea test and review the complications of this procedure in the literature.
CASE
A 54-year-old man with a prior history of arterial hypertension was admitted to the hospital due to impaired consciousness. He was eating when he had sudden neck pain and fell down to the floor. The same day, when admitted to the ICU he was comatose. A CT scan of the head showed a large right fronto-parietal and temporal hematoma, measuring approximately 300 ml in size. His past medical history included tobacco smoking but no chronic obstructive pulmonary disease, and a subtotal gastrectomy following gastrointestinal bleeding two years before.
One day after admission, the patient was still unresponsive. No brain or brain stem reflexes could be elicited. He met the AAN criteria for brain death. Core temperature was 36.6°C and blood pressure was 120/70. He received dopamine at a dose of 6 ug/kg/min. Pulmonary examination revealed bilateral rhonchi, although the chest X-ray was normal. Cardiovascular functions were stable before the apnea test. After preoxigenation with 100% oxygen, arterial oxygen tension was 400mmHg. In addition, the patient fulfilled the AT prerequisites. According to the AAN guidelines for performing the apnea test, a 12-french catheter was inserted 10 cm down into the y-endotracheal tube to provide an oxygen flow of 8 L/min. Two minutes later, oxygen saturation decreased to 60% and blood pressure to 80/40. At this moment, bradycardia ensued. Lung auscultation revealed bilateral absence of breath sounds. Abdominal distension and signs of cyanosis were observed. The oxygen catheter was removed and the patient was immediately connected again to the ventilator, although he continued to deteriorate. A chest X-ray showed massive bilateral pneumothorax and pneumoperitoneum. He did not respond to an IV epinephrine bolus and cardiac arrest occurred before the pneumothorax was treated. "Cardiac" death was declared after cardiopulmonary resuscitation maneuvers failed.
DISCUSSION
BD patients may be suitable organ donors. For that reason, the apnea test is an essential procedure to establish this diagnosis. Any complication during this procedure may impair organ perfusion.
The established AAN prerequisites for performing the apnea test are: core temperature > 36.5C, systolic blood pressure > 90 mmHg, corrected diabetes insipidus, pCO2 > 40 mmHg, and PO2 >200 mmHg after preoxigenation1.
The conventional technique consists in connecting a pulse oxymeter and disconnecting the ventilator. Subsequently, a cannula is placed at the level of the carina and 100% O2 is delivered at a rate of 8 liters per minute while looking closely for respiratory movements. PO2, CO2, and pH are measured at baseline and 8-10 minutes after. Subsequently, the ventilator is connected again. If respiratory movements remain absent and arterial PCO2 is >60 mmHg (or there is a 20 mmHg increase over a normal baseline PCO2), the apnea test is positive (supporting the diagnosis of BD)1. Artificial CO2 augmentation showed that the required time to perform the apnea test is markedly reduced when compared with the conventional technique5. Apnea denotes loss of brainstem function. Central chemoreceptors sense arterial PO2 and the pH of the CSF changes. Thus, they control the stimulus for neurons in the reticular and dorsal vagal nerve nuclei. There also are other mechanical and chemical influences on the respiratory neurons in the brainstem6,7.
Pitfalls in performing the apnea test could be encountered in clinical practice1,9. A few studies using small numbers of individuals have been performed in order to standardize this method10. There are anecdotal reports of medical complications during or after performing the apnea test2,3,10,11. However, prospective studies are lacking in the literature.
Gad Bar et al. reported two patients with tension pneumothorax during the apnea test2. One of them was a 55-year-old man who had intracerebral hemorrhage and developed pneumothorax when the catheter was at the level of the carina. The second case was a 14-year-old girl who had a severe head injury. One minute after starting the apnea test, "the chest looked insufflated". Both patients had arterial hypotension, bradycardia, and finally cardiac arrest. Marks and Zisfein mentioned a case with subcutaneous emphysema and thoracic insufflation3.
Wijdicks warned about the hypercarbia, acidosis, hypoxemia, and pulmonary edema that may appear during the apnea test. He questioned the safety of this procedure specially when the cited prerequisites were not considered4,7.
Cardiovascular adverse effects related to the apnea test have been reported in small series of patients, such as 30% decrease of the systemic vascular resistance, increment of the cardiac index, hypoxemia, arterial hypotension, and pulmonary hypertension7,9,10. Appropriate perfusion is a cardinal condition to preserve the organ function. Thus, prophylactic treatment with epinephrine or dopamine has been suggested to prevent hemodynamic complications, even though there is no evidence favoring this management.
We studied complications related to the AT in 129 BD individuals11. We found major and minor complications during the AT in more than two thirds of patients, including: arterial hypotension (12%), acidosis (68%), and hypoxemia (23%). Baseline hypotension (systolic blood pressure < 100 mmHg or median arterial blood pressure < 60 mmHg) and pH <7.30 were the most common predicting risk conditions.
We report a 55-year-old man with intracranial hemorrhage with no previous lung abnormalities, who developed thoracic and abdominal insufflation during the apnea test. This complication occurred even when following the recommendations for performing this test. The difference between our patient and other cases was the presence of abdominal insufflation. To our knowledge, this is the first documented-report of pneumoperitoneum associated with pneumothorax during this procedure. The pathophysiological bases are difficult to explain. Although no increase in peak airway pressure was detected, this may be the underlying clue. Several conditions may predispose to this complication, such as, a) mechanical factors e.g.: external diameter of the cannula, and length of the endotracheal tube, b) time between BD diagnosis and apnea test, and c) patient condition, e.g.: age, COPD, arterial hypotension, hypothermia, or acidosis. Thus, risk factors such as COPD, pneumonia, arterial hypotension, or acidosis should be taken into account and considered before performing this test. We also suggest delaying the apnea test in high-risk patients, especially in those with severe acidosis (pH <7.20) due to the risk of subsequent arterial hypotension and organ hypoperfusion.
In our country, as well as in others, an isoelectric EEG is a legal requirement for the diagnosis of BD. The apnea test is usually performed at the end of the clinical exam and before the EEG. Thus, a cardiac arrest due to a complication of this procedure may have legal implications because the BD diagnosis has not been definitely established in the individual yet.
Because of the documented complications during the apnea test, we do not consider this procedure as innocuous11. On the other hand, it is a cardinal requisite that should not be avoided to complete the diagnosis of BD. For this reason, we believe this test should be done at a more adequate time. Thus, we suggest the apnea test should be performed after the neurological evaluation and the EEG.
In summary, medical complications may occur during the apnea test. Prospective studies are necessary in order to establish high-risk conditions and to define the frequency of complications during this procedure.
Acknowledgment - Jose A. Bueri for his technical assistance and suggestions.
Dr. Gustavo Saposnik - Charcas 4431 4 "10" - Buenos Aires (1425) - Argentina. Fax: 5411 4803 8674. E-mail: gsaposnik@yahoo.com or saposnik@janssen.com.ar
- 1. Quality Standards Subcommittee of the American Academy of Neurology. Practice parameters for determining brain death in adults (summary statement). Neurology 1995;45:1012-1014.
- 2. Gad Bar J, Yaron-Bar L, Zeev Z. Tension pneumothorax during apnea testing for the determination of brain death. Anesthesiology 1998;89:1250-1251.
- 3. Marks SJ, Zisfein J. Apneic oxygenation in apnea test for brain death: a controlled trial. Arch Neurol. 1990;47:1066-1068.
- 4. Wijdicks E. In search of a safe apnea test in brain death: Is this procedure really more dangerous than we think?. Arch Neurol 1995;52:338-339.
- 5. Lang CJG. Apnea testing by artificial CO2 augmentation. Neurology 1995;45:966-969.
- 6. Ropper AH, Kennedy SK, Russell L. Apnea testing in the diagnosis of brain death: clinical and physiological observation. J Neurosurg 1981;55:942-946.
- 7. Wijdicks EFM. Determining brain death in adults. Neurology 1995;45:1003-1011.
- 8. Van Norman GA. A matter of life and death. Anesthesiology 1999;91:275-87.
- 9. Jeret JS, Benjamin JL. Risk of hypotension during the apnea testing. Arch Neurol. 1994;51:595-599.
- 10. Combes JC, Nicolas F, Cros N, D´athis P, Freysz M. Hemodynamic changes induced by apnea test in patients with brain death. Ann Fr Anesth Reanim. 1996;15:1173-1177.
- 11. Saposnik G, Rizzo G, Vega A, Sabattiello R, Deluca JL. Complications in the apnea test in the diagnosis of Brain Death. In press.
Publication Dates
-
Publication in this collection
06 Dec 2000 -
Date of issue
Sept 2000
History
-
Accepted
09 June 2000