Acessibilidade / Reportar erro

Range of motion after total knee arthroplasty

Abstracts

OBJECTIVE: To evaluate knee range of motion (ROM) after at least six months postoperatively in total knee arthroplasty, by comparing it to baseline value. MATERIALS AND METHODS: Ranges of motion of eighty arthroplasties were analyzed within an average follow-up of 21.9 months. RESULTS: No significant differences between pre- and postoperative averages for extension (p=0.09) and flexion (p=0.47) were found. By dividing the patients into two groups, a significant flexion improvement was seen in those with pre-op flexion equal or smaller than 90º (n=17) (p=0.000037). In the other group, a significant decrease in flexion was seen in those with pre-op flexion equal or greater than 120º (n=31) (p=0.000068). Four patients have been submitted to knee manipulations within an average of 2.1 months postoperatively. The mean flexion rate before manipulation and after six months was significantly different (p=0.0068). The mean pre-op flexion and after six months postoperatively was similar (p=0.28). CONCLUSION: Preoperative flexion significantly influences the post-op flexion in total knee arthroplasty. Its measurement provides the surgeon with a good parameter for previewing this.

Range of motion; Arthroplasty; Knee


OBJETIVO: Avaliar a amplitude de movimentos (ADM) do joelho após seis meses de pós-operatório de artroplastia total, comparando-a com o seu valor pré-operatório. MATERIAL E MÉTODOS: Foi analisada a amplitude de movimento de 80 artroplastias, com acompanhamento pós-operatório médio de 21,9 meses. RESULTADO: Não houve diferença significativa entre as médias pré e pós-operatória, de extensão (p=0,09) e flexão (p=0,47). Subdividindo os pacientes em dois grupos, naqueles com flexão pré-operatória menor ou igual a 90° (n=17) observou-se aumento significativo da flexão (p=0,000037). Naqueles com flexão pré-operatória maior ou igual a 120° (n=31) ocorreu diminuição significativa da flexão (p=0,000068). Quatro pacientes foram submetidos à manipulação, em média com 2,1 meses de pós-operatório. A média de flexão antes da manipulação e após seis meses dessa foi significativamente diferente (p=0,0068). Já as médias de flexão pré-operatória e após seis meses de pós-operatório foram semelhantes (p=0,28). CONCLUSÃO: A flexão pré-operatória influencia de forma significativa a flexão após artroplastia total do joelho. Sua medida fornece ao cirurgião bom parâmetro para prevê-la.

Amplitude de movimento; Artroplastia; Joelho


ORIGINAL ARTICLE

Range of motion after total knee arthroplasty

Lúcio Honório de Carvalho JúniorI; Cézar Augusto Costa de CastroII; Matheus Braga Jacques GonçalvesIII; Leonardo Costa Martins RodriguesIV; Felipe Vieira Pinto da CunhaIV; Fernando de Lima LopesIV

IPhD in Orthopaedics by Federal University of São Paulo (UNIFESP), Associate Professor, Department of Locomotive Apparatus, Medical School, UFMG. Orthopaedic doctor at Hospital Madre Teresa (HMT), Belo Horizonte

IIMember of SBOT, specialist student in Knee Surgery, HMT

IIIMember of SBOT, specialist in Knee Surgery, HMT

IVResident doctor in Orthopaedics and Traumatology, HMT

Correspondences to Correspondences to R. Olavo Carsalade Vilela, 264 Residencial Ipê da Serra, Nova Lima, MG, Brasil CEP 34.000-100 E-mail: luciohcj@medicina.ufmg.br

SUMMARY

Objective: To evaluate knee range of motion (ROM) after at least six months postoperatively in knee total arthroplasty, by comparing it to baseline value. Materials and Methods: Ranges of motion of eighty arthroplasties were analyzed within an average follow-up of 21.9 months. Results: No significant differences between pre- and postoperative averages for extension (p=0.09) and flexion (p=0.47) were found. By dividing the patients into two groups, a significant flexion improvement was seen in those with pre-op flexion equal or smaller than 90º(n=17) (p=0.000037). In the other group, a significant decrease in flexion was seen in those with pre-op flexion equal or greater than 120º (n=31) (p=0.000068). Four patients have been submitted to knee manipulations within an average of 2.1 months postoperatively. The mean flexion rate before manipulation and after six months was significantly different (p=0.0068). The mean pre-op flexion and after six months postoperatively was similar (p=0.28). Conclusion: Preoperative flexion significantly influences the post-op flexion in knee total arthroplasty. Its measurement provides the surgeon with a good parameter for previewing this.

Keywords:Range of motion; Arthroplasty; Knee.

INTRODUCTION

Knee total arthroplasty (KTA) has as an objective to provide relief from pain, correct deformities, and allow a functional range of motion, keeping stability and knee function for daily activities(1). KTA is an efficient procedure for the treatment of pain and for correcting deformities associated to the degenerative joint disease(2,3).

Despite of the evolutions on surgical techniques, on implants and on postoperative handling, stiffness is still a common problem after KTA(2). The range of motion (ROM) obtained postoperatively depends mostly of its preoperative score(3-6). Patient’s age and morphology, diagnosis and prosthesis models seem not to influence it(3-5).

The objective of this study is to evaluate ROM in knees of patients submitted to KTA comparing them to preoperative ROM scores.

MATERIALS AND METHODS

Between June, 1995 and July, 2004, 137 KTAs have been performed by the main author at the Hospital Madre Teresa (HMT) in Belo Horizonte (MG). By reviewing patients’ medical files, preoperative and 6 months postoperatively ROM scores were obtained. Fifty seven patients who missed the minimum follow-up time of 6 months or those for whom we couldn’t find the respective medical files have been excluded, totaling 80 arthroplasties being evaluated.

The mean age of patients was 71.6 years old, ranging from 54 to 91 years old. Sixty nine (86.25%) arthroplasties were performed in women and 11 (13.75%) in men. Forty six (57.5%) arthroplasties have been performed on the right side and 34 (42.5%) on the left side. All prostheses were cemented preserving the posterior cruciate ligament. Four different models were used: Duracon®- Howmedica®(46), Nexgen®- Zimmer®(17), Search®- Aesculap®(9) and Advantin®- Wright®(8). The diagnosis of osteoarthrosis was provided to 76 (95%) cases, rheumatoid arthritis to 3 (3.75%) and osteonecrosis in 1 (1.25%). Average postoperative follow-up was 21.9 months, with the longest being 102 months and the shortest 6 months.

The Student’s T-test was used for comparing averages with a significant p value if lower than 0.05.

The research design was approved by the Committee of Ethics in Research at HMT.

RESULTS

Mean preoperative range was 0.6° with a standard deviation (SD) equal to 2.53 and the mean postoperative range was 0.1° (SD=0.78). No significant difference was seen (p=0.09) among pre and postoperative average ranges. Mean preoperative flexion was 107.1° (SD=15.95) and the mean postoperative flexion was 108.6° (SD=11.87), with no significant difference seen among them (p=0.47).

By analyzing the results from another perspective, patients have been further divided into three groups: Group 1 - those with a preoperative flexion < 90º, Group 2 - those with a preoperative flexion > 120º, and Group 3- those submitted to manipulation. The different prosthesis models were uniformly distributed among the groups, and this was not considered as a confusing factor for the analysis of results.

Among the patients with a preoperative flexion lower or equal to 90° (n=17), the mean preoperative flexion was 85° (SD=8.66) and the mean postoperative flexion was 100.5° (SD=9.88). A significant difference was seen between those averages (p=0.000037).

For patients with a preoperative flexion higher or equal to 120° (n=31) the mean preoperative flexion was 123.5° (SD=4.88) and the mean postoperative flexion was 112.8° (SD=13.10). That difference has shown to be significant (p=0.000068).

Six arthroplasties (7.5%) evolved to postoperative stiffness (Group 3). In two patients, a ROM of 80º was accepted and in the others (n=4) manipulation was performed, within 2.1 months postoperatively, in average. The mean flexion for these patients was 107.5° (SD=15) preoperatively, 54.5° (SD=16.76) before manipulation, and 94.7° (SD=16.76) after six months postoperatively. The statistical analysis showed significant differences among the preoperative flexion values and those before manipulation (p=0.000046) and among the flexion averages before manipulation and after 6 months postoperatively (p=0.0068). No significant difference was seen between preoperative flexion and after 6 months postoperatively (p=0.28).

The results are summarized on Table 1.

DISCUSSION

The knee ROM required for daily activities was determined by biomechanical and gait analysis studies. Laubenthal et al..(7) showed that the patients require 67° of flexion during the gait balance phase, 83° for stepping up stairs, 100° for stepping down, 93° for standing up from a chair and between 71° and 117° for catching an object on the floor.

In agreement with the findings by Schurman and Rojer(6) who correlated five different kinds of knee prosthesis to the postoperative ROM, this study could not find a significant difference among the four kinds used.

This study confirms that the preoperative flexion is a valuable parameter for the prognosis of postoperative flexion after KTA, agreeing with the findings by Ritter and Stringer(3), Parsley et al.(5), Harvey et al.(4) and Schurman and Rojer(6). The mean preoperative flexion was similar to the average after six months of surgery (p=0.47). Ritter and Stringer(3) and Parsley et al.(5) stated that patients with little flexion before surgery tend to gain motion, and those having a bigger flexion tend to loose it. This trend was confirmed in this study. Patients with a flexion < 90° have gained motion (p=0.000037) while those with a flexion > 120° have lost it (p=0.000068).

Despite the technical advancements, stiffness is still a common complication after KTA. There is no universally acceptable criterion for its diagnosis. Stiffness is defined as an inappropriate range of motion for daily activities, resulting in functional restraints(2). According to literature, its incidence ranges from 8% to 12%(8). Among the patients in this study, six (7.5%) evolved to a flexion < 90° postoperatively.

Fox and Ross(9) and Esler et al.(10) showed that those patients gained motion after manipulation, achieving a flexion similar to preoperative value, evolving similarly to other patients. These observations are confirmed here. Among the patients submitted to knee manipulation, the flexion averages before manipulation and after six months postoperatively were significantly different (p=0.0068). The averages for preoperative flexion and after six months postoperatively were similar (p=0.28).

CONCLUSION

In the analysis of range of motion after KTA, the preoperative flexion significantly influenced the postoperative flexion. Its measurement provides the surgeon with a good parameter for predicting flexion after arthroplasty.

REFERENCES

Received: 04/04/05 approved in 22/08/05

Study conducted at Hospital Madre Teresa, in Belo Horizonte (MG), Brazil.

  • 1. Buechel FF, Pappas MJ. Long-term survivorship analysis of cruciate-sparing versus cruciate-sacrificing knee prostheses using meniscal bearings. Clin Orthop 1990; 260:162-9.
  • 2. Bong MR, Cesare PE. Rigidez após artroplastia total de joelho. J Am Acad Orthop Surg, 2004; 2: 227-34.(Edição Brasileira)
  • 3. Ritter MA, Stringer EA. Predictive range of motion after total knee replacement. Clin Orthop 1979; 143: 115-9.
  • 4. Harvey IA, Barry K, Kirby SP Johnson R, Elloy MA. Factors affecting the range of movement of total knee arthroplasty. J Bone Joint Surg Br 1993; 75: 950-5.
  • 5. Parsley BS, Engh GA, Dwyer KA. Preoperative flexion. Does it influence postoperative flexion after posterior-cruciate-retaining total knee arthroplasty? Clin Orthop 1992; 275:204-10.
  • 6. Schurman DJ, Rojer DE. Total knee arthroplasty. Range of motion across five systems. Clin Orthop 2005; 430: 132-7.
  • 7. Laubenthal KN, Smidt GL, Kettelkamp DB. A quantitative analysis of knee motion during activities of daily living. Phys Ther 1972; 52:34-43.
  • 8. Scranton PE Jr. Management of knee pain and stiffness after total knee arthroplasty. J Arthroplasty 2001; 16:428-35.
  • 9. Fox JL, Ross R. The role of manipulation following total knee replacement. J Bone Joint Surg Am 1981; 63:357.
  • 10. Esler CN, Lock K, Harper WM, Gregg PJ. Manipulation of total knee replacements. Is the flexion gained retained? J Bone Joint Surg Br 1999; 81:27-9.
  • Correspondences to
    R. Olavo Carsalade Vilela, 264
    Residencial Ipê da Serra, Nova Lima, MG, Brasil
    CEP 34.000-100
    E-mail:
  • Publication Dates

    • Publication in this collection
      26 Jan 2006
    • Date of issue
      2005

    History

    • Accepted
      22 Aug 2005
    • Received
      04 Apr 2005
    ATHA EDITORA Rua: Machado Bittencourt, 190, 4º andar - Vila Mariana - São Paulo Capital - CEP 04044-000, Telefone: 55-11-5087-9502 - São Paulo - SP - Brazil
    E-mail: actaortopedicabrasileira@uol.com.br