Objective

: To describe the surgical technique and preliminary clinical outcomes in a series of open reduction internal fixation of basal acromion process fractures applying a double-plating technique.

Methods

: Nine consecutive patients, mean age 33.4 years old (range, 23-61 years old) with unilateral acromion fracture (Type 3 AO/OTA) with more than 1cm displacement who underwent fixation utilizing a locked double-plating technique, were evaluated on average at 7.8 months (range, 3-15 months) for outcomes related to pain, shoulder function, and surgical complications.

Results

: Eight patients recovered with complete radiographic union and favorable shoulder function. One case failed to be fully evaluated for more than 3 months follow-up. The overall scores of Constant, Shoulder Pain and Disability Index (SPADI) and DASH for the eight patients reviewed were 91.9± 6.31, 3.11± 3.79 and 5.2± 6.35, respectively. No post-operative infection or surgical hardware irritation was identified at final follow-up of these eight patients.

Conclusion

: While more evidence is needed to justify its advantages over traditional implants, perpendicular double-plate with a locking system may be indicated for acromion pedicle fracture treatment, since it performed well for fracture healing and joint function rehabilitation. Level of Evidence IV, Therapeutic Study.