SHORT-TERM EVALUATION BETWEEN POLYETHYLENE THICKNESS IN PRIMARY TOTAL KNEE ARTHROPLASTY

AVALIAÇÃO A CURTO PRAZO ENTRE A ESPESSURA DO POLIETILENO NA ARTROPLASTIA TOTAL PRIMÁRIA DO JOELHO

ABSTRACT

Objective:

The objective of the research was to carry out a comparative study between Smith & Nephew ® or Zimmer ® prostheses with thick versus thin polyethylene, in patients undergoing primary total knee arthroplasty, during a short-term follow-up. Thus, the objective was to analyze the survival of the implants in question under the clinical and radiographic aspect.

Methods:

The sample was divided into two groups: Group 1 with thick polyethylene and group 2 with thin polyethylene. A clinical analysis of the patients was carried out and the implants were checked for loosening.

Results:

The groups were similar when compared. According to the Ahlbäck classification, 83% of the patients were in groups IV and V. The median functional score in the postoperative period was similar between the two groups. Postoperatively, the tibiofemoral angle fluctuated between 5 and 6 0 valgus on average. Two complications were observed in each group. None of the evaluated patients presented implant loosening

Conclusion:

Patients treated with thick polyethylene had the same functional score as the control group, as well as the absence of radiographic changes in this short-term follow-up, with implant survival and a similar rate of complications between both groups. Level of evidence III, Retrospective study.

Keywords:
Knee Arthroplasty; Joelho; Prosthesis Failure