Abstract
The aim of the present study was to perform a software-assisted radiographic assessment of the effect of platform-switching on marginal bone loss (MBL) around dental implants. Forty patients requiring a dental implant in non-grafted partially edentulous mandibles were enrolled and categorized into implants receiving a platform-matched abutment (control group) or implants with a platform-switched abutment (test group). Standardized digital periapical radiographs were taken at the time of implant placement (T0), at implant loading (T1) and 1-year after functional loading (T2). Software-assisted radiographic assessment of the MBL horizontal, vertical and area changes was performed and compared between time intervals (T1-T0, T2-T1 and T2-T0). Mean radiographic horizontal MBL (hMBL) and vertical MBL (vMBL) from implant placement to 1-year after implant loading (T2-T0) were significantly increased around platform-matched when compared to platform-switched abutments (1.04 mm vs 0.84 mm, p<0.05) and (0.99 mm vs 0.82 mm, p<0.05), respectively. Additionally, bone loss area (BLa) was greater (0.77 mm2 vs 0.63 mm2; p<0.05) for platform-matched compared to platform-switched abutments. Platform-switching has a positive impact upon the amount of bone modeling after loading implants with internal hexagon connection.
Key Words:
dental implant; platform switching; marginal bone loss; digital radiography
Resumo
O objetivo do presente estudo foi realizar uma avaliação radiográfica assistida por computador do efeito da plataforma reduzida sobre a perda óssea marginal (MBL) ao redor de implantes. Quarenta pacientes que necessitavam um implante em mandíbulas parcialmente edêntulas não enxertadas foram selecionados e divididos em implantes que receberam pilares de plataforma igualada (grupo controle) ou implantes com pilares de plataforma reduzida (grupo teste). Radiografias periapicais digitais padronizadas foram realizadas no momento da instalação do implante (T0), carregamento do implante (T1) e 1 ano após carregamento funcional (T2). Avaliação radiográfica assistida por computador da MBL horizontal, vertical e mudanças de área foi realizada e comparada entre os intervalos de tempo (T1-T0, T2-T1 e T2-T0). A média radiográfica da MBL horizontal (hMBL) e da MBL vertical (vMBL) do momento da instalação do implante até 1 ano após carregamento (T2-T0) foram significativamente aumentadas ao redor dos pilares de plataforma igualada quando comparado com os pilares de plataforma reduzida (1,04 mm vs 0,84 mm, p<0,05) e (0,99 mm vs 0,82,mm, p<0,05), respectivamente. Além disso, a área de perda óssea (BLa) foi maior (0,77 mm2 vs 0,63 mm2; p<0,05) para plataforma igualada comparada com pilares de plataforma reduzida. Plataforma reduzida tem um impacto positivo na remodelação óssea após carregamento de implantes com conexão interna hexagonal.
Introduction
Modern clinicians often choose implant therapy as the first treatment option to replace missing teeth. Morphological bone changes should be expected after tooth extraction and implant placement that may result in challenging situations and compromise aesthetics11 Paolantonio, M; Dolci, M; Scarano, A; d'Archivio, D; Di Placido, G; Tumini, V; et al.. Immediate implantation in fresh extraction sockets. A controlled clinical and histological study in man. J Periodontol 2001;72:1560-1571.. Early identification of surgical and prosthetic factors that induce detrimental effects upon the peri-implant tissues becomes crucial in routine procedures.
Peri-implant marginal bone loss (MBL) at the shoulder-abutment connection has been associated with biological complications that may trigger inflammatory events and further progressing to peri-implant diseases. Peri-implant tissue adaptations may result from the presence of biological width following implant rehabilitation, bacterial colonization at the implant shoulder-abutment interface and stress concentration at the implant shoulder during function22 Atieh, MA; Ibrahim, HM; Atieh, AH. Platform switching for marginal bone preservation around dental implants: a systematic review and meta-analysis. J Periodontol 2010;81:1350-1366.,33 Wagenberg, B; Froum, SJ. Prospective study of 94 platform-switched implants observed from 1992 to 2006. Int J Periodontics Restorative Dent 2010;30:9-17..
Platform switching advocates the concept of using smaller diameter abutments than the implant platform in order to reduce the amount of peri-implant MBL44 Lazzara, RJ; Porter, SS. Platform switching: a new concept in implant dentistry for controlling postrestorative crestal bone levels. Int J Periodontics Restorative Dent 2006;26:9-17.. The horizontal inward repositioning of the implant-abutment interface was responsible for confining the bone remodeling away from the outer edge of the implant and thus preserving the peri-implant tissues. Numerous studies evaluating the clinical outcomes of platform-switching have shown long-term promising results55 Fickl, S; Zuhr, O; Stein, JM; Hurzeler, MB. Peri-implant bone level around implants with platform-switched abutments. Int J Oral Maxillofac Implants 2010;25:577-581.,66 Prosper, L; Redaelli, S; Pasi, M; Zaron, F; Radaelli, G; Gherlone, EF. A randomized prospective multicenter trial evaluating the platform-switching technique for the prevention of postrestorative crestal bone loss. Int J Oral Maxillofac Implants 2009;24:299-308.. Moreover, studies including different diameter of implants77 Canullo, L; Fedele, GR; Iannello, G; Jepsen, S. Platform switching and marginal bone-level alterations: the results of a randomized-controlled trial. Clin Oral Implants Res 2010;21:115-121., implant surfaces88 Kielbassa, AM; Martinez de Fuentes, R; Goldstein, M,; Arnhart, C; Barlattani, A; Jackowski, J; et al.. Randomized controlled trial comparing a variable-thread novel tapered and a standard tapered implant: interim one-year results. J Prosthet Dent 2009;101:293-305. and abutment connections99 De Angelis, N; Nevins, ML; Camelo, MC; Ono, Y; Campailla, M; Benedicenti, S. Platform switching versus conventional technique: a randomized controlled clinical trial. Int J Periodontics Restorative Dent 2014;34 Suppl 3:s75-79. have been addressed as possible confounding factors to consider when selecting an implant system for platform switching.
To the authors' knowledge few studies examined the implant connection as a potential variable with a biological impact, rather than a mechanical effect upon MBL around platform-switched implants. Thus, this prospective study aimed to evaluate the effect of platform switching on implants with internal hexagonal connection. The work hypothesis was that implants with a platform-matched abutment have greater MBL than implants with a platform-switched abutment.
Material and Methods
Subject Selection
This study was approved by the Ethics Committee of the Dental School of the Universidade de São Paulo (Opinion 401 778). Patients undergoing dental care at the Dental Center of Military Police of São Paulo (COdont) and at Center of Excellence for Prosthodontics and Implant Dentistry (CEPI) of the Dental School, University of São Paulo were enrolled, treated and followed up within a 15-month interval. For each group, 18 patients were initially included, based on a statistical sample size for a bone loss statistical difference of 0.5 mm after 1 year of loading, p=0.05, 0.5 mm standard deviation and 85% of statistical power. Furthermore, 2 patients were added to each group considering a possible dropout of 10%. Patients with healed edentulous non-grafted sites in the posterior mandible requiring single implant restorations were eligible for the present study. Exclusion criteria were as follows: patients with uncontrolled systemic diseases, pregnant or lactating women, active periodontal disease, smoking, signs of parafunctional activity, history of oral cancer which requires radiation therapy and patient taking medications known to alter bone metabolism (i.e. bisphosphonates).
Surgical and Prosthetic Protocols
Virtual implant software was used (Dental Slice(r), Bioparts Prototipagem Biomédica, Brasília, DF, Brazil) to enable a three-dimensional bone reconstruction, allowing the diameter, length and position of the implants to be planned with greater precision. Patients were randomly categorized into two main groups: 4 mm diameter platform-matched abutments (control group) on a 4 mm diameter internal hexagonal implant (Conect AR(r), Conexão Sistema de Prótese, Arujá, Brazil) and 4 mm diameter platform-switched abutments (test group) on 5-mm diameter internal hexagonal implants. All implants had the same cylindrical-tapered design and acid-etched treated surface.
Under local anesthesia, the surgical sites were prepared with sequential drills under constant irrigation according to the manufacturer's recommendations and performed by the same surgeon (NS). Besides the quality and quantity of bone support, the mesiodistal and buccolingual inclination of the implants were chosen by the functional and aesthetic requirements. All implants were placed in native bone at crestal bone level in a prosthetically driven position and healing abutments were simultaneously installed. After implant placement, patients were under clinical and radiographic observation every four months during the whole study. Implants were excluded from the present study if probing depths ≥4 mm were associated with radiographic bone loss beyond the bone physiological remodeling, pain, mobility, bleeding on probing and/or suppuration1010 Weber, HP; Crohin, CC; Fiorellini, JP. A 5-year prospective clinical and radiographic study of non-submerged dental implants. Clin Oral Implants Res 2000;11:144-153.,1111 Mangano, C; Mangano, F; Shibli, JA; Ricci, M; Sammons, RL; Figliuzzi, M. Morse taper connection implants supporting "planned" maxillary and mandibular bar-retained overdentures: a 5-year prospective multicenter study. Clin Oral Implants Res 2011;22:1117-1124.,1212. American Academy of Periodontolgy. Peri-implant mucositis and peri-implantitis: a current understanding of their diagnoses and clinical implications. J Periodontol 2013;84:436-443.
The prosthetic phase was performed 3 months after implant installation. The choice of components, prosthetic planning, installation of abutments, clinical and radiographic evidence of copings and veneering was performed by the same professional (NS). Screwed porcelain-fused-to-metal crowns were used to restore implants and torqued following the manufacturers' instructions.
Radiographic Assessment
Standardized periapical radiographs were obtained at the time of implant placement (T0), at implant loading (T1) and 1-year after implant loading (T2). Periapical radiographs were digitized with a scanner (Scaner Vita Scan Combi Plus, Durr Dental AG, Bietigheim-Bissingen, Germany). A computer software (DBSWIN 5.2.0, Durr Dental) was used to calculate the distance between the outer edges of the implant platform to the first vertically (vDIB) and horizontally (hDIB) visible crestal bone ; and the bone loss area (BLa) circumscribed between vDIB and hDIB as depicted in Figure 1. All calculations were performed by the same calibrated examiner (NS) at all time points.
Software-assisted assessment of the distance between the outer edges of the implant platform to the first visible crestal bone vertically (vDIB) and horizontally (hDIB); and the bone loss area (BLa) circumscribed between vDIB and hDIB.
Statistical Analysis
Non-parametric Mann-Whitney and Student's t-test were used to verify the inter-group differences among the averages of vMBL, hMBL and BLa and to compare mean differences between variables at all time intervals (T1-T0, T2-T1, T2-T0), the Wilcoxon and paired t-test were used to verify differences between the experimental times. A possible association between time and bone loss was evaluated by linear regression.
Results
Forty patients were enrolled and classified according to their implant platform-abutment relationship. No implant was lost nor presented signs of peri-implant disease. Table 1 shows mean and standard deviation values between groups with respect of vMBL, hMBL and BLa, at T0, T1 and T2. Linear regression graphs indicate a significant progressive increase of vertical and horizontal bone loss (Figs. 2 and 3) and average bone loss area (Fig. 4) from the implant shoulder to bone crest in both groups, as a result of the physiological bone remodeling after implant placement (p<0.05).
Linear regression indicating a significant progressive increase of vertical bone loss for matched and switched abutments over 18 months.
Linear regression indicating a significant progressive increase of horizontal bone loss for matched and switched abutments over 18 months.
Linear regression indicating a significant progressive increase of bone loss area for matched and switched abutments over 18 months.
Peri-implant MBL comparisons between platform-matched (control) and platform-switched implants (test) are in Table 2. Changes in hMBL and vMBL between implant placement and implant loading (T1-T0) were significantly reduced (p<0.05), but no significant difference was found regarding the BLa (p>0.05). Comparisons between peri-implant MBL at implant loading and 1-year after functional loading (T2-T1) exhibited significant differences in hMBL and BLa (p<0.05), but not in vMBL (p=0.89). Finally, bone changes between implant placement and 1-year after functional loading (T2-T0) showed a significantly higher MBL for platform-matched abutments compared to platform-switched in hMBL, vMBL and BLa.
Discussion
The biologic width around osseointegrated implants has been extensively investigated1313 Berglundh, T; Lindhe, J. Dimension of the periimplant mucosa. Biological width revisited. J Clin Periodontol 1996;23:971-973.,1414 Cochran, DL; Obrecht,M; Weber, K; Dard M; Bosshardt D; Higginbottom FL; et al.. Biologic width adjacent to loaded implants with machined and rough collars in the dog. Int J Periodontics Restorative Dent 2014;34:773-779.. Effects of platform switching in limiting the peri-implant MBL have been discussed in both prospective and longitudinal human studies33 Wagenberg, B; Froum, SJ. Prospective study of 94 platform-switched implants observed from 1992 to 2006. Int J Periodontics Restorative Dent 2010;30:9-17.,99 De Angelis, N; Nevins, ML; Camelo, MC; Ono, Y; Campailla, M; Benedicenti, S. Platform switching versus conventional technique: a randomized controlled clinical trial. Int J Periodontics Restorative Dent 2014;34 Suppl 3:s75-79. and displayed long-term stability1515 Schwarz, F; Alcoforado, G; Nelson, K; Schaer, A; Taylor, T; Beuer, F; et al.. Impact of implant-abutment connection, positioning of the machined collar/microgap, and platform switching on crestal bone level changes. Camlog Foundation Consensus Report. Clin Oral Implants Res 2014;25:1301-1303.,1616 Fernandez-Formoso, N; Rilo, B; Mora, MJ; Martinez-Silva, I; Diaz-Afonso, AM. Radiographic evaluation of marginal bone maintenance around tissue level implant and bone level implant: a randomised controlled trial. A 1-year follow-up. J Oral Rehabil 2012;39:830-837.. Conversely, numerous studies have also reported results rejecting the platform-switching concept. After 2 years, Crespi et al.1717 Crespi, R; Cappare, P; Gherlone, E. Radiographic evaluation of marginal bone levels around platform-switched and non-platform-switched implants used in an immediate loading protocol. Int J Oral Maxillofac Implants 2009;24:920-926. reported a mean vMBL of 0.73 mm and 0.78 mm around matched and mismatched abutments, respectively1717 Crespi, R; Cappare, P; Gherlone, E. Radiographic evaluation of marginal bone levels around platform-switched and non-platform-switched implants used in an immediate loading protocol. Int J Oral Maxillofac Implants 2009;24:920-926.. Similarly, Enkling et al.1818 Enkling, N; Johren, P; Klimberg, V; Bayer, S; Mericske-Stern, R; Jepsen, S. Effect of platform switching on peri-implant bone levels: a randomized clinical trial. Clin Oral Implants Res 2011;22:1185-1192. showed mean vMBL of 0.58 mm and 0.53 mm around non-platform switching and platform switching after 12 months.
Implants restored according to the platform-switching concept could experience different patterns of MBL when compared to implants with platform-matched abutments. To avoid heterogeneity in the interpretation of the data, all patients underwent the same treatment modality in a similar way to a previous study1919 Al-Nsour, MM; Chan, HL; Wang, HL. Effect of the platform-switching technique on preservation of peri-implant marginal bone: a systematic review. Int J Oral Maxillofac Implants 2012;27:138-145.. The choice of the statistical power was settled before the clinical phase to avoid underpowering or overpowering. Between these two extremes, the statistical power of 85% reduced the chance of Type II error and the number of subjects, and assured the viability of the statistical analysis. This study revealed no significant differences between Group 1 and 2 in terms of mean vMBL and hMBL at T1 and T2. The only meaningful differences were observed when considering BLa. These results showed that both implants with matched and switched platform presented progressive bone loss. However, comparisons between different time intervals may be crucial to accurately confirm the concept of platform-switching1515 Schwarz, F; Alcoforado, G; Nelson, K; Schaer, A; Taylor, T; Beuer, F; et al.. Impact of implant-abutment connection, positioning of the machined collar/microgap, and platform switching on crestal bone level changes. Camlog Foundation Consensus Report. Clin Oral Implants Res 2014;25:1301-1303.. From the time point of prosthesis installation, which created a horizontal inward mismatch for the test group, to 1 year follow-up (T2-T1), a significant hMBL and BLa reduction occurred around switched platform implants and the linear regression showed a trend of higher MBL around matched platform implants over time.
A physiological bone remodeling around dental implants may occur after the connection of prosthetic components and the induction of mechanical loading. This shows up because of the biological width after the implant exposure to the oral cavity. Such findings are clinically relevant when considered the interproximal distances between implants or to an adjacent tooth. Tarnow et al.2020 Tarnow, DP, Cho, SC, Wallace, SS. The effect of inter-implant distance on the height of inter-implant bone crest. J Periodontol 2000;71:546-549.,2121 Tarnow, D; Elian, N; Fletcher, P; Froum, S; Magner, A; Cho, SC, et al.. Vertical distance from the crest of bone to the height of the interproximal papilla between adjacent implants. J Periodontol 2003;74:1785-1788. reported a minimal distance of 3.4 mm between implants in order to avoid soft tissue changes and 1.5 mm between adjacent teeth. The benefits of platform switching in a clinical setting could be advantageous as long as limited edentulous spaces are present and narrow implants are not considered, especially in the esthetic zone.
Furthermore, the MBL extension seems to be dependent upon a myriad of factors including implant collar design, apico-coronal implant location during placement and soft tissue thickness. Special attention to the soft tissue thickness indicated a potential key role in preventing peri-implant MBL. Linkevicius et al.2222 Linkevicius, T; Puisys, A; Steigmann, M; Vindasiute, E; Linkeviciene, L. Influence of vertical soft tissue thickness on crestal bone changes around implants with platform switching: a comparative clinical study. Clin Implant Dent Relat Res 2015;17:1228-1236. reported a mean MBL of 1.17 mm in thin soft tissues (<2 mm) and 0.21 mm in thick tissues (≥2 mm) on abutment mismatch after 1-year follow-up. Thin soft tissues (<2 mm) may prove detrimental upon peri-implant MBL despite the advised use of platform-switching2222 Linkevicius, T; Puisys, A; Steigmann, M; Vindasiute, E; Linkeviciene, L. Influence of vertical soft tissue thickness on crestal bone changes around implants with platform switching: a comparative clinical study. Clin Implant Dent Relat Res 2015;17:1228-1236.. Bacterial colonization could also induce a detrimental effect on the long-term stability around dental implants2323 Lindhe, J; Meyle, J. Peri-implant diseases: Consensus Report of the Sixth European Workshop on Periodontology. J Clin Periodontol 2008;35:282-285.. This may occur as consequence of leakage at the implant-abutment interface or as a result of contamination during implant placement and thus inhibiting the possible effects of platform-switching1717 Crespi, R; Cappare, P; Gherlone, E. Radiographic evaluation of marginal bone levels around platform-switched and non-platform-switched implants used in an immediate loading protocol. Int J Oral Maxillofac Implants 2009;24:920-926.,1818 Enkling, N; Johren, P; Klimberg, V; Bayer, S; Mericske-Stern, R; Jepsen, S. Effect of platform switching on peri-implant bone levels: a randomized clinical trial. Clin Oral Implants Res 2011;22:1185-1192.,2424. Romanos, GE; Biltucci, MT; Kokaras, A; Paster, BJ. Bacterial composition at the implant-abutment connection under loading in vivo. Clin Implant Dent Relat Res 2016;18:138-45..
Protein biomarkers and microbial profile from oral fluids could be valuable diagnostic and prognostic tools in the assessment of disease activity around dental implants2525. Li JY, Wang HL. Biomarkers associated with periimplant diseases. Implant Dent 2014;23:607-611.. Further clinical studies using biomarkers to monitor the physiological bone remodeling and changes in the microbiome in peri-implant sulcus are still required to help clinicians to make safe and predictable decisions in their clinical practice.
Within the limitations of the present study, it may be concluded that platform-switchings have a positive short-term impact upon the amount of marginal bone loss around loaded implants with internal hexagon connection. Further long-term longitudinal studies are required to validate this concept.
References
-
1Paolantonio, M; Dolci, M; Scarano, A; d'Archivio, D; Di Placido, G; Tumini, V; et al.. Immediate implantation in fresh extraction sockets. A controlled clinical and histological study in man. J Periodontol 2001;72:1560-1571.
-
2Atieh, MA; Ibrahim, HM; Atieh, AH. Platform switching for marginal bone preservation around dental implants: a systematic review and meta-analysis. J Periodontol 2010;81:1350-1366.
-
3Wagenberg, B; Froum, SJ. Prospective study of 94 platform-switched implants observed from 1992 to 2006. Int J Periodontics Restorative Dent 2010;30:9-17.
-
4Lazzara, RJ; Porter, SS. Platform switching: a new concept in implant dentistry for controlling postrestorative crestal bone levels. Int J Periodontics Restorative Dent 2006;26:9-17.
-
5Fickl, S; Zuhr, O; Stein, JM; Hurzeler, MB. Peri-implant bone level around implants with platform-switched abutments. Int J Oral Maxillofac Implants 2010;25:577-581.
-
6Prosper, L; Redaelli, S; Pasi, M; Zaron, F; Radaelli, G; Gherlone, EF. A randomized prospective multicenter trial evaluating the platform-switching technique for the prevention of postrestorative crestal bone loss. Int J Oral Maxillofac Implants 2009;24:299-308.
-
7Canullo, L; Fedele, GR; Iannello, G; Jepsen, S. Platform switching and marginal bone-level alterations: the results of a randomized-controlled trial. Clin Oral Implants Res 2010;21:115-121.
-
8Kielbassa, AM; Martinez de Fuentes, R; Goldstein, M,; Arnhart, C; Barlattani, A; Jackowski, J; et al.. Randomized controlled trial comparing a variable-thread novel tapered and a standard tapered implant: interim one-year results. J Prosthet Dent 2009;101:293-305.
-
9De Angelis, N; Nevins, ML; Camelo, MC; Ono, Y; Campailla, M; Benedicenti, S. Platform switching versus conventional technique: a randomized controlled clinical trial. Int J Periodontics Restorative Dent 2014;34 Suppl 3:s75-79.
-
10Weber, HP; Crohin, CC; Fiorellini, JP. A 5-year prospective clinical and radiographic study of non-submerged dental implants. Clin Oral Implants Res 2000;11:144-153.
-
11Mangano, C; Mangano, F; Shibli, JA; Ricci, M; Sammons, RL; Figliuzzi, M. Morse taper connection implants supporting "planned" maxillary and mandibular bar-retained overdentures: a 5-year prospective multicenter study. Clin Oral Implants Res 2011;22:1117-1124.
-
12American Academy of Periodontolgy. Peri-implant mucositis and peri-implantitis: a current understanding of their diagnoses and clinical implications. J Periodontol 2013;84:436-443.
-
13Berglundh, T; Lindhe, J. Dimension of the periimplant mucosa. Biological width revisited. J Clin Periodontol 1996;23:971-973.
-
14Cochran, DL; Obrecht,M; Weber, K; Dard M; Bosshardt D; Higginbottom FL; et al.. Biologic width adjacent to loaded implants with machined and rough collars in the dog. Int J Periodontics Restorative Dent 2014;34:773-779.
-
15Schwarz, F; Alcoforado, G; Nelson, K; Schaer, A; Taylor, T; Beuer, F; et al.. Impact of implant-abutment connection, positioning of the machined collar/microgap, and platform switching on crestal bone level changes. Camlog Foundation Consensus Report. Clin Oral Implants Res 2014;25:1301-1303.
-
16Fernandez-Formoso, N; Rilo, B; Mora, MJ; Martinez-Silva, I; Diaz-Afonso, AM. Radiographic evaluation of marginal bone maintenance around tissue level implant and bone level implant: a randomised controlled trial. A 1-year follow-up. J Oral Rehabil 2012;39:830-837.
-
17Crespi, R; Cappare, P; Gherlone, E. Radiographic evaluation of marginal bone levels around platform-switched and non-platform-switched implants used in an immediate loading protocol. Int J Oral Maxillofac Implants 2009;24:920-926.
-
18Enkling, N; Johren, P; Klimberg, V; Bayer, S; Mericske-Stern, R; Jepsen, S. Effect of platform switching on peri-implant bone levels: a randomized clinical trial. Clin Oral Implants Res 2011;22:1185-1192.
-
19Al-Nsour, MM; Chan, HL; Wang, HL. Effect of the platform-switching technique on preservation of peri-implant marginal bone: a systematic review. Int J Oral Maxillofac Implants 2012;27:138-145.
-
20Tarnow, DP, Cho, SC, Wallace, SS. The effect of inter-implant distance on the height of inter-implant bone crest. J Periodontol 2000;71:546-549.
-
21Tarnow, D; Elian, N; Fletcher, P; Froum, S; Magner, A; Cho, SC, et al.. Vertical distance from the crest of bone to the height of the interproximal papilla between adjacent implants. J Periodontol 2003;74:1785-1788.
-
22Linkevicius, T; Puisys, A; Steigmann, M; Vindasiute, E; Linkeviciene, L. Influence of vertical soft tissue thickness on crestal bone changes around implants with platform switching: a comparative clinical study. Clin Implant Dent Relat Res 2015;17:1228-1236.
-
23Lindhe, J; Meyle, J. Peri-implant diseases: Consensus Report of the Sixth European Workshop on Periodontology. J Clin Periodontol 2008;35:282-285.
-
24Romanos, GE; Biltucci, MT; Kokaras, A; Paster, BJ. Bacterial composition at the implant-abutment connection under loading in vivo Clin Implant Dent Relat Res 2016;18:138-45.
-
25Li JY, Wang HL. Biomarkers associated with periimplant diseases. Implant Dent 2014;23:607-611.
Publication Dates
-
Publication in this collection
Nov-Dec 2016
History
-
Received
Sept 2016 -
Accepted
Nov 2016