Open-access Assessment of open source software for CBCT in detecting additional mental foramina

Abstract

The purpose of this study was to evaluate which post-processing imaging protocol would be better to analyze the additional mental foramen (AMF) in preoperative planning with cone-beam computed tomography (CBCT) exams, and to test reproducibility of measurements, using open source software (OsiriX). The software was used to detect the cases of AMF from among 58 exams for dental implant planning in edentulous mandible areas-three cases were found. The case images were submitted to qualitative analysis using 2D orthogonal MPR, 3D-MPR and 3D volume rendering protocols by two oral and maxillofacial radiologists. Quantitative analysis used the 3D-MPR protocol; the closed polygon tool measured the mental foramen (MF) and the AMF areas; the length tool measured the distance between foramina. The measurements were performed independently by the examiners, at two different times. Intra- and interexaminer agreement was assessed using the intraclass correlation coefficient. The panoramic view did not show the MF and the AMF clearly. The AMF could be detected in the parasagittal view. 2D Orthogonal MPR was effective to observe the AMF in some cases. The 3D-MPR and 3D view protocols were the most effective to locate and analyze the AMF. In conclusion, a 3D view improves visualization when anatomical points are not clearly visible. 3D-MPR was considered a more effective post-processing imaging protocol to observe foramina relationships. The high reproducibility of measurements for anatomical MF variations was established using specific tools featured in open source software for CBCT. OsiriX is realistic and recommended for preoperative planning.

Cone Beam Computed Tomography; Imaging, Three-Dimensional; Mandible; Tomography, X-Ray Computed


Introduction

Knowledge of the distances, location and number of mental foramina is useful in defining safe areas when performing mandible procedures.1 Anatomical variations of the MF have been reported in many studies. The most common cases are the multiple foramina.2-4 In rare cases, the mental foramen may not even exist.5 The double mental foramen is reported in literature as a result of the branching of the mental nerve before it passes through the MF.6 The reported frequency of AMF varies according to ethnic group:

  • 1.4% of 510 sides examined in American Whites,

  • 5.7% of 332 sides examined in African Americans, and

  • 7% of 157 samples of the Central and South America population.7,8

Several studies on MF variations have been published in regard to two-dimensional radiographic techniques and the dissection of dry mandibles.2,9-11 Three-dimensional reconstructed images from cone-beam computed tomography (3D-CBCT) are more reliable and accurate than two-dimensional radiography of craniofacial structures for diagnosis, and allow multiple imaging post-processing protocols for better and more correct treatment planning and evaluation.2,12,13

The aim of this study was to assess cone-beam computed tomography (CBCT) imaging using open source software, by analyzing which post-processing imaging protocol would be better for planning a procedure and for clearly identifying the existence of anatomical variations. Another aim was to test the reproducibility of 3D-CBCT for measuring anatomical landmarks, such as the MF and AMF, using open source software.

Methodology

Subjects

Data from the CBCT examinations of 71 patients (29 males and 42 females) who had undergone dental implant treatment planning in edentulous mandible areas from December 2010 to February 2011 were analyzed. Nine CBCT examinations with excessive artifacts in the mandible area were excluded. Four exams with CBCT acquisition problems were excluded because of poor image quality. Anatomic variation with clinical consequences was observed in a total of 58 exams, which were set aside for analysis with open source software for preoperative planning. Three cases of AMF were detected (5.17%), and were analyzed with different post-processing protocols of the open source software.

Data acquisition

The CBCT scans were taken by i CAT Classic (Imaging Sciences International, Hatfield, USA), using the following acquisition protocol: 120 kVp, 36.12 mAs, field of view (FOV) measuring 60 mm in height and 160 mm in diameter, and 0.25 mm voxel reconstruction. After image acquisition, the data were stored in a digital imaging communication in medicine (DICOM) file format and imported to an independent workstation (iMac 27, Mac OsX 10.6, Apple, Inc., Cupertino, USA) with open-source DICOM viewer OsiriX 4.0 (Pixmeo, Geneva, Switzerland; www.osirix-viewer.com). OsiriX software can be used to view volumetric images that capture, store, communicate, process and display DICOM (.dcm file) images. It also generates 3D reconstructed images. All the study cases were analyzed by two oral and maxillofacial radiologists12,14-16 using different OsiriX software tools. Two views were made for implant planning:

  • first, a panoramic view (3D Curved MPR, at mean mode 10.15 mm thick),

  • and then, a parasagittal view (3D Curved MPR).

Imaging analysis

The three cases of AMF were detected in implant planning and subsequently analyzed in three different imaging visualization protocols offered specifically by the OsiriX software. The following protocols were used to conduct the qualitative analysis and to observe the anatomical aspects of this landmark:

  • multiplanar reconstruction (2D Orthogonal MPR),

  • 3D multiplanar reconstruction (3D-MPR), and

  • 3D view (3D volume rendering with low contrast, 16-bit and CLUT editor to reduce red scale).

Qualitative analysis was conducted to observe the location of the additional foramen and describe aspects of the additional foramen relationship to adjacent structures, to intraosseous communication and to the MF. The image analyses were performed in random order to reach an agreement. The examiners were asked to identify the main MF and the AMF, by describing the characteristics of these anatomical landmarks. The observers could use all available tools and functions in each protocol. In the 2D Orthogonal MPR, the same position of each one plane is showed on the other two planes, with a thin cross reference line. The 3D-MPR enables the examiner to change the position or orientation of one of the three planes (coronal, sagittal, and axial) to obtain two reconstructed planes. The 3D view protocol displays images with one-point linear perspective projection, increasing the potential of locating and observing the relationship of adjacent structures. The descriptions obtained for each case were collated and ultimately generated the final qualitative analysis.

Quantitative analysis was performed to measure the area of the additional foramen in relation to the MF and the distance between both. OsiriX tools were used to perform measurements:

  • the closed polygon ROI (region of interest) (Figure 1), allowing polygons to be drawn by clicking on as many corners as needed and displaying information such as area and perimeter instantly, and

Figure 1
Closed polygon ROI used for measuring MF area.

  • the length ROI (Figures 2a, b), allowing the drawing of simple lines to compute linear measurements.

Figure 2
a: Length ROI used for measuring the distance between foramina. b: Length ROI used in the case of a distal AMF, to measure the outermost part of the cortical bone between foramina.

The 3D-MPR view was used to obtain the foramen area by marking its limits to the outermost part of the cortical bone, using the closed polygon. The distance between the foramina (the main MF and the AMF) was calculated with the length tool in this view, by measuring the outermost part of the cortical bone located in this region, in a reconstructed image that allows viewing the two foramina. The measurements were made by two oral and maxillofacial radiologists, independently, at two different times. Intraexaminer (at an interval of two weeks) and interexaminer (the first time and after the second time) agreement was assessed according to the intraclass correlation coefficient (ICC).

Results

Implant planning

The panoramic view did not show the main foramen or the additional foramen clearly in any case analyzed (Figure 3a). In the parasagittal view (Figure 3b), a trabecular bone dividing the output of the mandibular canal caused the two foramina to branch out, observed in case 1 and case 2. In case 3, the branching out was noted along the course of the mandibular canal, and an accessory branch could be identified distally to the main MF. No other cases of AMF were detected.

Figure 3
a: Panoramic view (3D curved MPR, at mean mode 10.15 mm thick) showing the area demarcated for obtaining the parasagittal view. b: The MF and the AMF (arrows) with the presence of bone trabeculae in the parasagittal view.

Qualitative analysis

The additional foramen could be located in all three cases using the 2D Orthogonal MPR view, corresponding to a coronal, sagittal, and axial image. In the coronal view, a trabecular bone separating the foramina was observed in cases 1 and 2. This pattern was not observed in case 3. In the sagittal view, the branching out at the canal output was evident in case 1. In case 2, the separation of the mandibular canal into two mental foramina could be clearly seen. In case 3, the two foramina could be discerned on the same slice. In case 1, the MF was observed superiorly, and the additional foramen, inferiorly, in the axial view. However, in case 2, it was difficult to distinguish which foramen should be classified as additional, whether that appearing superiorly or inferiorly. In case 3, the branching out of the mandibular canal along its course was evident, and the two foramina were observed on the same slice. The advantage of this post-processing imaging protocol is that it enables easy navigation through the tomographic slices because the orientation planes are locked. However, the location and the relationship to adjacent structures of the AMF are limited.

3D-MPR allowed the imaging views to be manipulated freely, resulting in a reconstructed sagittal view depicting two foramina (Figures 4a, b). In case 1, two foramina were easily detected, with a trabecular bone separating one foramen superiorly and the other, inferiorly. In case 2, the two foramina were more difficult to detect clearly in the same view, with a trabecular bone separating one foramen superiorly and the other foramen, inferiorly. In case 3, the AMF could be observed distally to the MF. The advantage of this post-processing imaging protocol was the ability to change the position or orientation of one plane to obtain reconstructed images showing the two foramina, thereby enabling more reliable measurements.

Figure 4
a: Crosshair (black and white) tool of 3D-MPR in an axial view positioned at the foramen output (arrow) to generate a reconstructed image. b: Reconstructed sagittal image depicting two foramina.

The 3D view showed the location of the AMF in relationship to the MF (Figure 5), whereby the location was classified as distal-inferiorly in case 1, inferiorly in case 2, and distal-inferiorly in case 3. Both mental and additional foramina were clearly visible. The advantage of this post-processing imaging protocol was its ability to locate MF and AMF immediately.

Figure 5
3D view (3D volume rendering with low contrast, 16-bit and CLUT editor) with improved visualization of AMF and MF location.

Quantitative analysis

Table 1 shows the measurements of the MF and AFM areas, the distance between the superior and the inferior foramina, and between the mesial and the distal foramina, made by two observers at two different times. The statistical results comparing the measurements made by the observers are shown in Table 2.

Table 1
Measurements of the MF and AMF areas and the distance between the main mental foramen and the additional mental foramen, made by two observers in two different analyses.
Table 2
Statistical results comparing the measurements made by the two observers.

According to the classification system proposed by Fleiss17, the replicability of the method adopted may be considered as excellent. The p-value ranged from p = 0.0009 to p = 0.0331 in the interexaminer analysis. The intraexaminer analysis obtained a variation of p = 0.0011 to p = 0.0052 for observer 1 and p = 0.0014 to p = 0.0040 for observer 2. The intraclass correlation (ICC) statistic used to make the comparison between measurements showed coefficients ranging from 0.9032 to 0.9565 (maximum value = 1) for the interobserver analysis, and ranging from 0.9184 to 0.9666 for the intraobserver analysis (maximum value = 1).

Discussion

Unlike other studies, our methodology was standardized to obtain the reconstructed images for measurements, thus preventing changes in the orientation of planes from interfering with the results obtained. In 3D-MPR, the observer in our study manipulated the image view to obtain an angle of the MF at the outermost section of the buccal surface bone, in order to measure the diameter of the foramen. This pattern was used in all measurements. Naitoh et al. 14 obtained the diameter measurement by calculating the long and short axes (a and b) of each foramen according to the elliptic area formula:

No specification regarding the image view used to perform the measurements was cited. In this study, the area was calculated with the closed polygon ROI feature of the OsiriX system, which gives the result for the area immediately after the user marks the limit points of the foramen. The measurements of the foramina area are used in some classifications to determine which AMF could be classified as double mental foramen or accessory mental foramen according to size.³

Naitoh et al. 14 calculated the distance between foramina by marking a horizontal axis and a vertical axis starting at the center of the largest foramen and then calculating the distance to the center of the other foramen, using the formula:

Conversely, in this study, the distance between the foramina was calculated by measuring the trabecular bone or the outermost cortical bone (in the 3D-MPR reconstructed images) with a straight line drawn by the length ROI tool, which gives the result for the linear measurement immediately and can be useful to estimate a safe area.

Noninvasive methods, like CBCT, enable observations of anatomical investigation to be more accurate. Accordingly, more cases of multiple mental foramina will be detected. This type of mandible image is very effective in identifying the location of such mandibular landmarks as the canal and both mental and mandibular foramina, as well as the course and branches of inferior alveolar nerves and vessels.4

Good knowledge of mental nerve anatomy and branches is very important for conducting surgical procedures, nerve block and local anesthesia,1 implant insertion14 and periapical surgery, and for better understanding endodontic-related pain and paresthesia.18 Knowing where the additional mental foramen is located may prevent nerve and vascular injury.1,19 The double mental foramen may innervate and vascularize a distant area, like that of case 3. It may also interfere in anesthetic techniques, and its unusual location may further complicate surgical procedures, causing traumas, hemorrhage and paresthesia. Implant planning should be carried out very carefully, especially in an edentulous premolar area.

Typically, the AMF is smaller than the mental foramen; hence, it is more difficult to visualize. In cases where the existence of the additional foramen is not certain, or where the mental foramen is not displayed on the panoramic radiograph, examination by CBCT is recommended.

According to Yamauchi et al. 15 and Costa et al. 20 and also Cavalcanti,21 OsiriX is easy-to-use open source software, offering advanced and useful post-processing imaging protocols, thus making it a versatile DICOM viewer offering regular updates. In our opinion the post-processing method used in this software is a new and important tool for the dental preoperative planning of procedures like implant placement and oral surgery, mainly for cases with anatomical variations that could interfere in the final result, and that are scarcely detected with two-dimensional radiographic techniques.

Cavalcanti21 reported that 3D-CBCT using OsiriX open source DICOM viewer has a potential application for craniofacial surgical planning and also for qualitative and quantitative analyses. Based on this statement,21 our study demonstrated the assessment of MF and AMF for implant planning. Because CBCT is a volumetric imaging tool, special focus should be directed toward medical information technology. The tools provided in visualization programs are new to many professionals. This makes the learning curve more complex-the learning task requires effort. This issue must be analyzed with deep and critical insight.21

In our opinion, 3D-CBCT imaging using OsiriX software is an effective digital analysis tool, and a valuable imaging modality for improving diagnosis and treatment planning, thus ensuring the best guidance for dental implant surgical interventions. Keeping abreast of the recent developments in medical imaging is essential, and interactive hardware-software should be prioritized.

Conclusion

In conclusion, the 3D view protocol improved visualization when anatomical points were not clearly visible, thus affording the means to obviate surgery failure. 3D-MPR was considered a more effective post-processing imaging protocol to observe the relationship between the MF and the AMF, and also made it possible to locate these points to conduct further measurements. However, it is necessary to establish a standard protocol to analyze this anatomical variation. A high reproducibility of measurements to ascertain anatomical MF variations was established using specific tools featured in open source software for CBCT.

Acknowledgements

The authors would like to thank CAPES (Coordination of the Advancement of Higher Education, Brasilia, Brazil) for its funding, provided through a Masters scholarship (Oséas Santos Junior) and a PhD scholarship (Otavio Umetsubo); FAPESP, for providing a PhD scholarship (Lucas Pinheiro); and the CNPq (National Council for Research, Brasilia, Brazil), for Universal Research Project grant no. 472895/2009-5, and Research Productivity Scholarship grant no. 303847/2009-3, awarded to Dr. Marcelo Cavalcanti.

References

  • 1 Haktanir A, Ilgaz K, Turhan-Haktanir N. Evaluation of mental foramina in adult living crania with MDCT. Surg Radiol Anat. 2010 Apr;32(4):351-6.
  • 2 Kaufman E, Serman NJ, Wang PD. Bilateral mandibular accessory foramina and canals: a case report and review of the literature. Dentomaxillofac Radiol. 2000 May;29(3):170-5.
  • 3 Oliveira-Santos C, Souza PH, De Azambuja Berti-Couto S, Stinkens L, Moyaert K, Van Assche N, et al. Characterisation of additional mental foramina through cone beam computed tomography. J Oral Rehabil. 2011 Aug;38(8):595-600.
  • 4 Igarashi C, Kobayashi K, Yamamoto A, Morita Y, Tanaka M. Double mental foramina of the mandible on computed tomography images: a case report. Oral Radiol. 2004 Dec;20(2):68-71.
  • 5 Silva Ramos Fernandes L, Capelozza A, Rubira-Bullen I. Absence and hypoplasia of the mental foramen detected in CBCT images: a case report. Surg Radiol Anat. 2011 Oct;33(8):731-4.
  • 6 Serman NJ. Differentiation of double mental foramina from extra bony coursing of the incisive branch of the mandibular nerve--an anatomic study. Refuat Hashinayim. 1987 Jul;5(3):20-2.
  • 7 Sawyer DR, Kiely ML, Pyle MA. The frequency of accessory mental foramina in four ethnic groups. Arch Oral Biol. 1998 May;43(5):417-20.
  • 8 Hanihara T, Ishida H. Frequency variations of discrete cranial traits in major human populations. IV. Vessel and nerve related variations. J Anat. 2001 Sep;199(3):273-87.
  • 9 Al Talabani N, Gataa I, Jaff K. Precise computer-based localization of the mental foramen on panoramic radiographs in a Kurdish population. Oral Radiol. 2008;24(2):59-63.
  • 10 de Freitas V, Madeira MC, Toledo Filho JL, Chagas CF. Absence of the mental foramen in dry human mandibles. Acta Anat (Basel). 1979;104(3):353-5.
  • 11 Mendonca Amorim M, Bevilacqua Prado F, Bicalho Borini C, Oliveira Bittar T, Volpato MC, Groppo FC, et al. The mental foramen position in dentate and edentulous brazilian's mandible. Int J Morphol. 2008;26(4):981-7.
  • 12 Cavalcanti MG, Ruprecht A, Vannier MW. 3D volume rendering using multislice CT for dental implants. Dentomaxillofac Radiol. 2002 Jul;31(4):218-23.
  • 13 Klinge B, Petersson A, Maly P. Location of the mandibular canal: comparison of macroscopic findings, conventional radiography, and computed tomography. Int J Oral Maxillofac Implants. 1989 Winter;4(4):327-32.
  • 14 Naitoh M, Hiraiwa Y, Aimiya H, Gotoh K, Ariji E. Accessory mental foramen assessment using cone-beam computed tomography. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2009. Feb;107(2):289-94.
  • 15 Yamauchi T, Yamazaki M, Okawa A, Furuya T, Hayashi K, Sakuma T, et al. Efficacy and reliability of highly functional open source DICOM software (OsiriX) in spine surgery. J Clin Neurosci. 2010 Jun;17(6):756-9.
  • 16 Albuquerque MA, Gaia BF, Cavalcanti MG. Oral cleft volumetric assessment by 3D multislice computed tomographic images. Int J Oral Maxillofac. 2011 Nov;40(11):1280-88.
  • 17 Fleiss JL. Design and analysis of clinical experiments. Hoboken (NJ): Wiley Interscience Publications, John Wiley & Sons, Inc; 1999.
  • 18 Joyce AP, Donnelly JC. Evaluation of the effectiveness and comfort of incisive nerve anesthesia given inside or outside the mental foramen. J Endod. 1993 Aug;19(8):409-11.
  • 19 Katakami K, Mishima A, Shiozaki K, Shimoda S, Hamada Y, Kobayashi K. Characteristics of accessory mental foramina observed on limited cone-beam computed tomography images. J Endod. 2008 Dec;34(12):1441-5.
  • 20 Costa FF, Gaia BF, Umetsubo OS, Cavalcanti MGP. Detection of horizontal root fracture with small-volume cone-beam computed tomography in the presence and absence of intracanal metallic post. J Endod. 2011 Oct;37(10):1456-9.
  • 21 Cavalcanti MG. Cone beam computed tomographic imaging: perspective, challenges, and the impact of near-trend future applications. J Craniofac Surg. 2012 Jan;23(1):279-82.

Publication Dates

  • Publication in this collection
    Apr 2013

History

  • Received
    20 July 2012
  • Reviewed
    07 Dec 2012
  • Accepted
    21 Dec 2012
location_on
Sociedade Brasileira de Pesquisa Odontológica - SBPqO Av. Prof. Lineu Prestes, 2227, 05508-000 São Paulo SP - Brazil, Tel. (55 11) 3044-2393/(55 11) 9-7557-1244 - São Paulo - SP - Brazil
E-mail: office.bor@ingroup.srv.br
rss_feed Acompanhe os números deste periódico no seu leitor de RSS
Acessibilidade / Reportar erro