Hoon Kim et al. (88. Kim JH, Byeon HK, Kim DH, Kim SH, Choi EC, Koh YW. ICG-Guided Sentinel Lymph Node Sampling during Robotic Retroauricular Neck Dissection in cN0 Oral Cancer. Otolaryngol Head Neck Surg. 2020;162(3):410-3. https://doi.org/10.1177/0194599819900264 https://doi.org/10.1177/0194599819900264...
) |
|
2.5 mg/ml |
2 ml |
ICG |
peritumoral |
Firefly system, robotic system, |
preoperative |
- |
Ishiguro et al. (99. Ishiguro K, Iwai T, Izumi T, Sugiyama S, Baba J, Oguri S, et al. Sentinel lymph node biopsy with preoperative CT lymphography and intraoperative indocyanine green fluorescence imaging for N0 early tongue cancer: A long-term follow-up study. J Craniomaxillofac Surg. 2020;48(3):217-22. https://doi.org/10.1016/j.jcms.2020.01.007 https://doi.org/10.1016/j.jcms.2020.01.0...
) |
Daiichi Sankyo Company, Tokyo, Japan |
5 mg/ml |
2 ml |
ICG |
peritumoral |
CTL, near-infrared camera |
intraoperative |
- |
Honda et al. (1010. Honda K, Ishiyama K, Suzuki S, Kawasaki Y, Saito H, Horii A. Sentinel Lymph Node Biopsy Using Preoperative Computed Tomographic Lymphography and Intraoperative Indocyanine Green Fluorescence Imaging in Patients With Localized Tongue Cancer. JAMA Otolaryngol Head Neck Surg. 2019;145(8):735-40. https://doi.org/10.1001/jamaoto.2019.1243 https://doi.org/10.1001/jamaoto.2019.124...
) |
Daiichi Pharmaceutical |
5 mg/ml |
2 ml |
CT lymphography, ICG |
peritumoral |
FLAIR, near-infrared camera, HEMS, PDE |
preoperative |
1 min/2 min |
Meershoek et al. (1111. Meershoek P, van den Berg NS, Brouwer OR, Teertstra HJ, Lange CAH, Valdés-Olmos RA, et al. Three-Dimensional Tumor Margin Demarcation Using the Hybrid Tracer Indocyanine Green-99mTc-Nanocolloid: A Proof-of-Concept Study in Tongue Cancer Patients Scheduled for Sentinel Node Biopsy. J Nucl Med. 2019;60(6):764-9. https://doi.org/10.2967/jnumed.118.220202 https://doi.org/10.2967/jnumed.118.22020...
) |
ICG-Pulsion; Pulsion Medical Systems |
1.25 mg/ml |
80 MBq |
ICG-99mTc-nanocolloid |
peritumoral |
PDE, near-infrared camera, |
preoperative |
- |
KleinJan et al. (1212. KleinJan GH, van Werkhoven E, van den Berg NS, Karakullukcu MB, Zijlmans HJMAA, van der Hage JA, et al. The best of both worlds: a hybrid approach for optimal pre- and intraoperative identification of sentinel lymph nodes. Eur J Nucl Med Mol Imaging. 2018;45(11):1915-25. https://doi.org/10.1007/s00259-018-4028-x https://doi.org/10.1007/s00259-018-4028-...
) |
Pulsion Medical Systems, Múnich, Germany |
1.25 mg/ml |
81 MBq |
ICG-99mTc-nanocolloid, blue dye |
peritumoral |
SPECT/CT, near-infrared camera, γ-probe |
preoperative |
15 min/2 h |
Digonnet et al. (1313. Digonnet A, van Kerckhove S, Moreau M, Willemse E, Quiriny M, Ahmed B, et al. Near infrared fluorescent imaging after intravenous injection of indocyanine green during neck dissection in patients with head and neck cancer: A feasibility study. Head Neck. 2016;38(4) Suppl 1:E1833-7. https://doi.org/10.1002/hed.24331 https://doi.org/10.1002/hed.24331...
) |
Pulsion Medical System, Belgium |
0.25 mg/kg |
- |
ICG |
intravenous |
near-infrared camera |
intraoperative |
2 h |
Christensen et al. (1414. Christensen A, Juhl K, Charabi B, Mortensen J, Kiss K, Kjær A, et al. Feasibility of Real-Time Near-Infrared Fluorescence Tracer Imaging in Sentinel Node Biopsy for Oral Cavity Cancer Patients. Ann Surg Oncol. 2016;23(2):565-72. https://doi.org/10.1245/s10434-015-4883-7 https://doi.org/10.1245/s10434-015-4883-...
) |
ICG-Pulsion,Pulsion Medical, Germany |
0.25 mg/ml |
0.2 ml |
ICG-99mTc -nanocolloid |
peritumoral |
SPECT/CT, near-infrared camera, γ-probe |
preoperative |
- |
Peng et al. (1515. Peng H, Wang SJ, Niu X, Yang X, Chi C, Zhang G. Sentinel node biopsy using indocyanine green in oral/oropharyngeal cancer. World J Surg Oncol. 2015;13:278. https://doi.org/10.1186/s12957-015-0691-6 https://doi.org/10.1186/s12957-015-0691-...
) |
Dandong, China |
5 mg/ml |
1 ml |
blue dye, ICG |
peritumoral |
near-infrared camera |
preoperative |
10 min |
Nakamura et al. (1616. Nakamura T, Kogashiwa Y, Nagafuji H, Yamauchi K, Kohno N. Validity of sentinel lymph node biopsy by ICG fluorescence for early head and neck cancer. Anticancer Res. 2015;35(3):1669-74.) |
Daiichi Sankyo, Tokyo, Japan |
2.5 mg/ml |
0.5 ml |
99mTc, ICG |
peritumoral |
HEMS monitor, |
preoperative |
19.8±12.6 min |
Murase et al. (1717. Murase R, Tanaka H, Hamakawa T, Goda H, Tano T, Ishikawa A, et al. Double sentinel lymph node mapping with indocyanine green and 99m-technetium-tin colloid in oral squamous cell carcinoma. Int J Oral Maxillofac Surg. 2015;44(10):1212-7. https://doi.org/10.1016/j.ijom.2015.05.008 https://doi.org/10.1016/j.ijom.2015.05.0...
) |
Diagnogreen; Daiichi Pharmaceutical, Tokyo, Japan |
5 mg/ml |
0.4 ml |
ICG |
peritumoral |
γ-probe |
intraoperative |
2 h |
Borbón-Arce et al. (1818. Borbón-Arce M, Brouwer OR, van den Berg NS, Mathéron H, Klop WM, Balm AJ, et al. An innovative multimodality approach for sentinel node mapping and biopsy in head and neck malignancies. Rev Esp Med Nucl Imagen Mol. 2014;33(5):274-9. https://doi.org/10.1016/j.remnie.2014.06.015 https://doi.org/10.1016/j.remnie.2014.06...
) |
ICG-Pulsion, Pulsion Medical Systems, Múnich, Germany |
2.5 mg/ml |
85 MBq |
ICG-99m Tc-nanocolloid |
peritumoral |
SPECT/CT, near-infrared camera, γ-probe, PDE |
preoperative |
15 min/2 h |
Joost et al. (1919. van der Vorst JR, Schaafsma BE, Verbeek FP, Keereweer S, Jansen JC, van der Velden LA, et al. Near-infrared fluorescence sentinel lymph node mapping of the oral cavity in head and neck cancer patients. Oral Oncol. 2013;49(1):15-9. https://doi.org/10.1016/j.oraloncology.2012.07.017 https://doi.org/10.1016/j.oraloncology.2...
) |
Pulsion Medical Systems (Múnich, Germany) |
2.5 mg/ml |
1.6 mL |
blue dye, ICG-99m Tc, HSA |
peritumoral |
Mini-FLARE imaging system |
preoperative |
5/10/15/30 min |
Frontado et al. (2020. Frontado ML, Brouwer OR, van den Berg NS, Mathéron HM, Vidal-Sicart S, van Leeuwen FW, et al. Added value of the hybrid tracer indocyanine green-99mTc-nanocolloid for sentinel node biopsy in a series of patients with different lymphatic drainage patterns. Rev Esp Med Nucl Imagen Mol. 2013;32(4): 227-33. https://doi.org/10.1016/j.remnie.2013.05.015 https://doi.org/10.1016/j.remnie.2013.05...
) |
ICG-Pulsion, Pulsion Medical Systems, Múnich, Alemania |
5 mg/ml |
86.5 MBq |
ICG-99m Tc-nanocolloid |
peritumoral |
SPECT/CT, γ- camera |
preoperative |
10 min/15 min/2 h |
Nynke et al. (2121. van den Berg NS, Miwa M, KleinJan GH, Sato T, Maeda Y, van Akkooi AC, et al. (Near-Infrared) Fluorescence-Guided Surgery Under Ambient Light Conditions: A Next Step to Embedment of the Technology in Clinical Routine. Ann Surg Oncol. 2016;23(8):2586-95. https://doi.org/10.1245/s10434-016-5186-3 https://doi.org/10.1245/s10434-016-5186-...
) |
Pulsion Medical Systems, Múnich, Germany |
2.5 mg/ml |
0.4 ml |
ICG-99m Tc -nanocolloid |
peritumoral |
SPECT/CT, near-infrared camera, γ-probe, |
preoperative |
3-19 h |