Acessibilidade / Reportar erro

Exposure assessment to metals in an armament repair shop of a military organization

The aim of this study was the occupational exposure assessment to lead and manganese of workers in an armament repair shop of a military organization. The air of the working environment was assessed in the environmental monitoring while the internal dose biological indicators for lead and manganese, in blood and urine, were used in biological monitoring. Metals concentration in filters and biological fluids were determined by electrothermal atomic absorption spectrometry. The results of the environmental monitoring showed lead and manganese levels above the TLV-TWA during the process of painting (313.33 g m-3) and solder (951 μg m-3). The biological indicators revealed that five of the nine employees presented Pb-S levels that suggested an environmental exposure to lead (values between 5 and 10 μg dL-1). It can be concluded that there is a small occupational exposure to lead and manganese in the superficial treatment repair shop. This exposure is influenced by weather conditions and the variable demand of work.

Lead; Manganese; Air; Blood; Urine; Exposure assessment


ABRASCO - Associação Brasileira de Saúde Coletiva Av. Brasil, 4036 - sala 700 Manguinhos, 21040-361 Rio de Janeiro RJ - Brazil, Tel.: +55 21 3882-9153 / 3882-9151 - Rio de Janeiro - RJ - Brazil