Acessibilidade / Reportar erro

Risk of false-positive result in mammography screening in Brazil

False-positive results on mammography screening are common, putting a burden on both women and the health care system. This study aimed to estimate the risk of false-positive results in Brazilian mammography screening based on data from the Brazilian Unified National Health System (SUS) information systems. A retrospective cohort study was conducted with women aged 40-69 years, who underwent mammography screening and breast histopathological examination at SUS from 2017 to 2019. The rate of false-positive results was estimated based on the prevalence of altered BI-RADS results on mammography screening and the proportion of benign results on breast histopathological examination. Of the 10,671 women with histopathological examination at SUS, 46.2% had a benign result, and this proportion was significantly higher in women aged 40-49 years compared to women aged 50-69 years. The estimate of false-positive results was 8.18 cases per 100 women aged 40-49 years and 6.06 per 100 women aged 50-69 years. This information is useful for public managers in evaluating mammography screening programs, as well as for health care providers to guide women on the implications of mammography screening.

Keywords:
False Positive Reactions; Mammography; Tamizajwe Masivo; Breast Neoplasms


Escola Nacional de Saúde Pública Sergio Arouca, Fundação Oswaldo Cruz Rua Leopoldo Bulhões, 1480 , 21041-210 Rio de Janeiro RJ Brazil, Tel.:+55 21 2598-2511, Fax: +55 21 2598-2737 / +55 21 2598-2514 - Rio de Janeiro - RJ - Brazil