ABSTRACT
Objective:
To assess the effectiveness of a customized distalizer with Variety SP® screws anchored on palatal miniscrews for upper molar distalization.
Methods:
Seventeen patients aged between 12.5 and 24 years underwent distalization with a customized distalizer. Lateral cephalogram and cast analysis were performed before and after distalization. Linear and angular parameters of the upper first molar, first premolar, and central incisor were assessed.
Results:
Distalization with the force passing near the center of resistance (CRes) of the upper first molars resulted in distal movement, with minimal distal tipping (2.8 ± 0.45°, p< 0.05). However, distalization passing occlusal to the CRes led to greater distal tipping (13.6 ± 1.63°, p< 0.05). Statistically significant spontaneous distal tipping and distal movement of the upper first premolars occurred, with a mean of 6.2 ± 1.24° (p< 0.05) and 0.68 ± 0.34 mm (p< 0.05), respectively. The positional change of the upper central incisors presented a mean of -0.23 ± 0.1 mm (p> 0.05) and 2.65 ± 1.1° (p< 0.05). Upper first molar intrusion was statistically significant, with a mean of 0.88 ± 0.2 mm (p< 0.05).
Upper right and left first molars rotation towards palatal midline presented mean of 4.1 ± 0.19° (p< 0.05) and 3.4 ± 0.1° (p< 0.05), respectively. Additionally, the distance between upper right and left first molars increased significantly, with a mean of 2.54 ± 0.01 mm (p< 0.05).
Conclusion:
The study successfully demonstrated the efficiency of molar distalization without anchorage loss using a customized distalizer anchored on palatal miniscrews.
Keywords:
Cephalometrics; Class II; Distalization; Orthodontic miniscrew
RESUMO
Objetivo:
Avaliar a eficácia de um distalizador personalizado com parafusos Variety SP® ancorado em mini-implantes palatinos para distalização de molares superiores.
Métodos:
Dezessete pacientes com idade entre 12,5 e 24 anos foram submetidos à distalização com o distalizador customizado. Análises das radiografias cefalométricas laterais e dos modelos de gesso foram realizadas antes e depois da distalização. Foram avaliados parâmetros lineares e angulares dos primeiros molares, primeiros pré-molares e incisivos centrais superiores.
Resultados:
A distalização com a força passando perto do centro de resistência (CRes) dos primeiros molares superiores resultou em distalização com inclinação mínima (2,8 ± 0,45°, p< 0,05). Entretanto, a distalização passando oclusal ao CRes levou a uma maior inclinação para distal (13,6 ± 1,63°, p< 0,05). Ocorreu inclinação distal espontânea e movimento distal estatisticamente significativo dos primeiros pré-molares superiores, com média de 6,2 ± 1,24° (p< 0,05) e 0,68 ± 0,34 mm (p< 0,05), respectivamente. A mudança de posicionamento dos incisivos centrais superiores apresentou média de -0,23 ± 0,1 mm (p> 0,05) e 2,65 ± 1,1° (p< 0,05). A intrusão dos primeiros molares superiores foi estatisticamente significativa, com média de 0,88 ± 0,2 mm (p< 0,05). A rotação dos primeiros molares superiores direito e esquerdo em direção à linha média palatina apresentou média de 4,1 ± 0,19° (p< 0,05) e 3,4 ± 0,1° (p< 0,05), respectivamente. Além disso, a distância entre os primeiros molares superiores direito e esquerdo aumentou significativamente, com média de 2,54 ± 0,01 mm (p< 0,05).
Conclusão:
O estudo demonstrou com sucesso a eficiência da distalização de molares sem perda de ancoragem utilizando um distalizador customizado ancorado em mini-implantes palatinos.
Palavras-chave:
Cefalometria; Classe II; Distalização; Mini-implante ortodôntico
INTRODUCTION
Distalization of upper molars as a method for correction of upper crowding is getting more and more popular as an alternative to premolar extraction. Despite the large number of molar distalizing devices, orthodontists prefer compliance-free intraoral bonded appliances. There are many types of intraoral distalizers known by orthodontists, for example: Distal Jet, Pendulum, Jones Jig, iPanda, etc. Many of them have disadvantages, such as loss of anchorage, molar tipping and rotation during distalization and compromised oral hygiene. The Pendulum appliance, introduced by Dr. James Hilgers in 1992, is one of the most popular options. Various modifications of the Pendulum appliance exist today. Byloff et al.11 Byloff FK, Darendeliler MA. Distal molar movement using the pendulum appliance. Part 1: Clinical and radiological evaluation. Angle Orthod. 1997;67(4):249-60. conducted a study to evaluate the dental and skeletal effects of the Pendulum appliance. The results demonstrated that the pendulum appliance moved molars distally without creating a dental or skeletal bite opening, with little anchorage loss. However, a significant amount of molar tipping should be considered when using this appliance. In the study of Bussick et al.22 Bussick TJ, McNamara Jr JA. Dentoalveolar and skeletal changes associated with the pendulum appliance. Am J Orthod Dentofacial Orthod. 2000 Mar;117(3):333-43., the mean distalization with the Pendulum appliance was 5.7 mm.
Intraoral distalization appliances typically comprise a distalizing mechanism and anchor teeth. To prevent anchorage loss during distalization, orthodontists have started using distalization appliances in combination with palatal miniscrews. A study by Kinzinger et al.33 Kinzinger GS, Gülden N, Yildizhan F, Diedrich PR. Efficiency of a skeletonized distal jet appliance supported by miniscrew anchorage for noncompliance maxillary molar distalization. Am J Orthod Dentofacial Orthod. 2009 Oct;136(4):578-86. evaluated the effectiveness of a skeletonized distal jet appliance for maxillary molar distalization. In the area of the cement-enamel junction, the permanent first molars were distalized by a mean of 3.92 ± 0.53 mm and intruded by a mean of 0.16 ± 0.26 mm. At the same time, they experienced distal tipping of 2.79 ± 2.51°. The first premolars, included in the anchorage setup, mesialized by 0.72 ± 0.78 mm and simultaneously tipped by 1.15 ± 2.98° to the palatal plane. They also reported an increase in transverse widths and mesiopalatal rotation of both right and left upper first molars.33 Kinzinger GS, Gülden N, Yildizhan F, Diedrich PR. Efficiency of a skeletonized distal jet appliance supported by miniscrew anchorage for noncompliance maxillary molar distalization. Am J Orthod Dentofacial Orthod. 2009 Oct;136(4):578-86.
Grec et al.44 Grec RH, Janson G, Branco NC, Moura-Grec PG, Patel MP, Castanha Henriques JF. Intraoral distalizer effects with conventional and skeletal anchorage: a meta-analysis. Am J Orthod Dentofacial Orthop. 2013 May;143(5):602-15., in their meta-analysis, compared the effects of intraoral distalizers with conventional and skeletal anchorage. They concluded that molar distalization was effective with both anchorage systems. The amount of distal molar movement was 3.34 mm with conventional anchorage and 5.10 mm with the skeletal anchorage system. The conventional anchorage system showed anchorage loss, represented by a premolar mesial movement of 4.01 mm44 Grec RH, Janson G, Branco NC, Moura-Grec PG, Patel MP, Castanha Henriques JF. Intraoral distalizer effects with conventional and skeletal anchorage: a meta-analysis. Am J Orthod Dentofacial Orthop. 2013 May;143(5):602-15..
It is known that some intraoral palatal distalizers induce the rotation of upper first molars around the palatal root during distalization, due to a force passing palatally to the center of rotation of the molar55 Acar AG, Gürsoy S, Dinçer M. Molar distalization with a pendulum appliance K-loop combination. Eur J Orthod. 2010 Aug;32(4):459-65.. Kinzinger et al.66 Kinzinger GS, Diedrich PR. Biomechanics of a Distal Jet appliance. Angle Orthod. 2008 Jul;78(4):676-81. evaluated the biomechanics of a distal jet appliance, and reported that during the application of force palatal to the center of resistance (CRes) of the upper first molars, the teeth experienced therapeutically undesired mesial-inward and distal-outward rotation.66 Kinzinger GS, Diedrich PR. Biomechanics of a Distal Jet appliance. Angle Orthod. 2008 Jul;78(4):676-81.
To mitigate rotational movement and extend overall treatment duration, the approach of the present study utilizes a rigid and resistant distalizing mechanism, capable of counteracting molar rotation and intrusion, while also providing reliable anchorage post-distalization. Thus, the objective of this study was to assess the type of distal movement observed in upper teeth when utilizing a palatal distalizer with Variety SP® screws anchored on palatal miniscrews.
MATERIAL AND METHODS
Twenty patients, comprising three boys and fourteen girls aged between 12.5 and 24 years, were randomly chosen for bilateral upper molar distalization. The purpose of this intervention was to address dentoalveolar Class II malocclusion and dental arch length discrepancies.
The inclusion criteria encompassed patients with edge-to-edge Class II molar relationships and mild to moderate crowding in the maxilla. Exclusion criteria involved individuals with skeletal constriction of the maxilla, those who had undergone unilateral molar distalization, individuals with a history of prior orthodontic treatment, and those with insufficient oral hygiene.
All patients and their parents were provided with detailed information regarding the necessity of distalization and the associated procedures. Consent was obtained through the signing of an agreement form.
The distalizing appliance comprised a palatal acrylic Nance button securely bonded to two palatal miniscrews. Utilizing two 12.0-mm long Variety SP® expansion screws (Dentaurum GmbH & Co. KG, Turnstr. 31, 75228 Ispringen, Germany), positioned parallel to the alveolar crest and extending from the acrylic Nance button, the screws were welded to the upper first molar bands. The connecting wire had a diameter of 1.48 mm (Figs 1 and 2).
Preoperative mouth-rinsing with a 0.1% chlorhexidine solution was performed two days before and on the day of insertion. Local terminal anesthesia, using an adrenaline-free anesthetic, preceded the placement of the two miniscrews with neck and collar lengths of 8 mm and a diameter of 1.65 mm (Tomas, Dentaurum, Germany). The miniscrews were positioned in the paramedian region of the maxilla in the anterior palate area, using a manual screwdriver without predrilling.
Primary stability tests were conducted for all miniscrews. Three patients, experiencing palatal soft tissue inflammation after the initiation of distalization and requiring appliance removal, were excluded from the study. In four cases, upper third molars were extracted before the initiation of distalization. However, in the remaining thirteen cases, the upper third molars were in the germinating stage, eliminating the need for extraction.
Immediately after miniscrew insertion, impressions for the distalizing appliance confection were taken, using Zhermack Elite HD+ A-Silicone material. These impressions were promptly sent to a technician for the fabrication of the appliance.
It is commonly believed that titanium alloy miniscrews may undergo partial osseointegration approximately three weeks after insertion.77 Ohmae M, Saito S, Morohashi T, Seki K, Qu H, Kanomi R, et al. A clinical and histological evaluation of titanium mini-implants as anchors for orthodontic intrusion in the beagle dog. Am J Orthod Dentofacial Orthop. 2002 May;119(5):489-497.,88 Vande Vannet B, Sabzevar MM, Wehrbein H, Asscherickx K. Osseointegration of miniscrews: a histomorphometric evaluation. Eur J Orthod. 2007 Oct;29(5):437-42. Hence, our decision was to bond the appliance after this three-week period. Patients were instructed to activate the distalizing screws on each side with a quarter turn per week. In three cases, patients faced difficulties during self-activation, leading the orthodontist to perform the activations.
Lateral cephalograms were captured using Planmeca Promax 3D (Helsinki, Finland) before (T1) and after (T2) distalization for all ten patients.
All lateral cephalograms were analyzed using Dolphin Imaging software by the same operator, who performed the analysis twice at a 2-week interval. In cases in which differences in measurements arose, the means of both readings were utilized in the subsequent statistical analysis (Figs 3 and 4).
An example of lateral cephalogram tracings superimposition (T1 = black line, T2 = green line).
The analysis involved calculating the potential movement of incisors and first premolars, as well as the relative distal movement of the first molars concerning the pterygoid vertical (PTV). Reference points for measurements were established as the most distal point of the crown for the upper first molars (U6) and first premolars (U4), along with the cement-enamel junction of the upper incisors (CEJ) (U1). To evaluate changes in the vertical plane of the upper first molars, the distance between the mesiobuccal cusp tip and the Frankfort horizontal plane was measured. In cases of overlapping structures, a midpoint between two points was marked for accurate assessment.
Angular movements of U1, U4, and U6 were determined by measuring angles between the axis of teeth and the anterior cranial base. Distal tipping of the upper first molar was assessed as a decrease in the angle between the longitudinal axis of the molar and the cranial base. Conversely, for the upper first premolar and incisor, mesial tipping or flaring was reflected in the increase of the angle between the longitudinal axis of the teeth and the cranial base (Fig 5).
To assess upper first molar rotation and intermolar width, intraoral scans of the maxilla were taken for twelve patients at the start of treatment and immediately after the cessation of distalization. Intraoral scans were performed using the 3Shape TRIOS 3 intraoral scanner (3Shape A/S, Copenhagen, Denmark), and casts were generated with OrthoAnalyzer software (3Shape) (Fig 6).
A decrease in the angle between the line passing through the mesiobuccal cusp tip and mesiopalatal cusp tip and the palatal midline was indicative of first molar mesial-inward rotation. For intermolar width evaluation, the distance between the mesiobuccal cusp tips of the left (UL6) and right (UR6) first molars was measured, and an increase in this measurement indicated expansion.
The calculated parameters are detailed in Table 1.
STATISTICAL ANALYSIS
To assess the reliability of cephalometric measurements and cast analysis, two sets of measurements were taken for each participant, at two-week intervals. The possible error between the two sets of measurements was calculated using the Dahlberg formula.
Statistical calculations were conducted using SPSS software (version 14, SPSS, Chicago, Ill). The normality of the measured data was assessed using the Shapiro-Wilk test. Changes in each measurement from T1 to T2 underwent statistical analysis through a paired t-test analysis when a normal distribution was seen, while the Wilcoxon test was used for non-normally distributed data.
Differences with a significance level p< 0.05 (5%) were considered statistically significant. The relationship between distal tipping of upper molars and distal movement, as well as distal tipping and intrusion, was assessed using the Pearson correlation coefficient (r).
The primary objective was to reject the null hypothesis, thereby affirming the effective distalization of the upper first molars induced by the appliance.
RESULTS
The mean distalization duration was 6.8 months. The possible error between the two sets of cephalometric measurements calculated using the Dahlberg formula, yielded a value of 1.1° for angular measurements and 0.8mm for linear measurements. For cast analysis, Dahlberg formula revealed possible error of 2.3° for angular and 0.6 mm for linear measurements.
The results of T1 and T2 cephalogram analysis are shown in Table 2. Mean and standard deviations of T1 and T2 analysis are shown in Table 3.
Significant differences in distal movement and distal tipping of the upper first molars were found. According to measurements, the upper first molars’ mean distal movement (U6-dis.point/PTV) and distal tipping (U6/SN) were 3.8 mm (p< 0.05) and 6.0° (p< 0.05), respectively. In twelve patients, the mean distal tipping of the upper molars was 2.8 ± 0.45° (p< 0.05) and in five cases, the molars were tipped distally at a mean of 13.6 ± 1.63° (p< 0.05). In two of twelve patients, a small root movement of the upper first molars was found.
The upper first premolars tipped distally (U4/SN) on average 6.2 ± 1.24° (p< 0.05), and the mean change in distance between U4-dis.point and PTV was 0.68 ± 0.34 mm (p< 0.05). The distance from the cement-enamel junction of the maxillary central incisor to the PTV point (U1 CEJ./PTV) was increased in some patients and decreased in others, but the mean change was -0.23 ± 0.1 mm (p> 0.05). On the other hand, the maxillary central incisors were tipped palatally 2.65 ± 1.1° (p< 0.05).The mean change in distance between the mesiobuccal cusp tip of the maxillary first molar and the FH was 0.88 ± 0.2 mm (p< 0.05). In twelve cases, the distance remained unchanged or exhibited statistically insignificant differences, with a mean 0.29 ± 0.04 mm (p> 0.05). However, in five cases, intrusion of the upper first molars was observed, with a mean of 2.3 ± 0.79 mm (p< 0.05).
The Pearson correlation coefficient (r) between upper first molar distal tipping and intrusion was 0.47. Additionally, the Pearson correlation coefficient (r) between upper first molar distalization and distal tipping was -0.0052.
Distance between mesiobuccal cusp tips of upper right and left first molar increased a mean of 2.54 mm (p< 0.05). The angle between mesiobuccal cusp-mesiopalatal cusp tips and palatal midline decreased a mean of 4.1 ± 0.19° (p< 0.05) and 3.4 ± 0.1° (p< 0.05) for UR6 and UL6 respectively.
DISCUSSION
In twelve cases, the upper first molars moved distally almost bodily, with minor distal tipping. However, in five cases, the molars tipped distally significantly, in conjunction with distal movement. The biomechanical explanation could be the force passing occlusal to the CRes of the upper molars. According to Gandhi et al.99 Gandhi V, Luu B, Dresner R, Pierce D, Upadhyay M. Where is the center of resistance of a maxillary first molar? A 3-dimensional finite element analysis. Am J Orthod Dentofacial Orthop. 2021 Sep;160(3):442-50.e1., the CRes of the maxillary first molar is situated apically and distally to the trifurcation area. Its specific location can vary among different patients. To ensure controllable movement, it is crucial to consider the tooth CRes during the process of distalization. However in some cases, due to insufficient palatal depth, technicians find it challenging to place distalizing screws deep enough for the force to pass near the CRes of the first molars.
In the present study, we investigated the relationship between upper first molar distal tipping and distal movement. The Pearson correlation coefficient (r = -0.0052) suggests a very week linear relationship between upper first molar distal tipping and distal movement. This suggests that the degree of distal tipping was not significantly associated with the amount of distal movement in the present study sample.
Distal tipping of the upper first molar is more pronounced when the second molar is in the germinating phase.1010 Kinzinger GS, Fritz UB, Sander FG, Diedrich PR. Efficiency of a pendulum appliance for molar distalization related to second and third molar eruption stage. Am J Orthod Dentofacial Orthop. 2004 Jan;125(1):8-23. In the present study, ten cases involved fully erupted second molars, while in seven cases, the second molars were in the eruption phase. In these seven cases, we observed distal movement with small distal tipping of the upper first molars.
Kircali et al.1111 Kircali M, Yüksel AS. Evaluation of dentoalveolar and dentofacial effects of a mini-screw-anchored pendulum appliance in maxillary molar distalization. Turk J Orthod. 2018 Dec;31(4):103-9. evaluated the dentoalveolar and dentofacial effects of a miniscrew-supported pendulum appliance during upper molar distalization, reporting 4.2 mm of first molar distalization, significant distal tipping of 8.9°, and a significant intrusion of 0.6 mm. In another study, Cozzani et al.1212 Cozzani M, Pasini M, Zallio F, Ritucci R, Mutinelli S, Mazzotta L, et al. Comparison of maxillary molar distalization with an implant-supported distal jet and a traditional tooth-supported distal jet appliance. Int J Dent. 2014:2014:937059. reported 4.7 ± 1.6 mm of distalization, 2.8° of distal tipping, and 0.7 mm of intrusion in the upper first molars using a group of miniscrew-supported distal jet appliances. Chiu et al.1313 Chiu PP, McNamara Jr JA, Franchi L. A comparison of two intraoral molar distalization appliances: Distal jet versus pendulum. Am J Orthod Dentofacial Orthop. 2005 Sep;128(3):353-65., in their comparison of two intraoral molar distalization appliances (distal jet versus pendulum), reported 1.7 ± 1.4 mm of extrusion of the U6 in the distal jet group and 1.6 ± 1.2 mm in the pendulum group. In another study, Tekale et al.1414 Tekale PD, Patil HA, Garg K, Kerudi VV, Parhad SM, Sharan JS, et al. A three-dimensional finite element analysis of mini-implant supported K-loop for maxillary molar distalization. J Indian Orthod Soc. 2023;57(2):62-9. reported 0.25 mm of intrusion movement on the distal cusp of the maxillary first molar and 0.14 mm of extrusion movement on the mesial cusp of the first molar in the Z direction. Kinzinger et al.33 Kinzinger GS, Gülden N, Yildizhan F, Diedrich PR. Efficiency of a skeletonized distal jet appliance supported by miniscrew anchorage for noncompliance maxillary molar distalization. Am J Orthod Dentofacial Orthod. 2009 Oct;136(4):578-86. reported a mean extrusion of the first molar of 0.63 ± 0.70 mm. In another study, Kinzinger et al.66 Kinzinger GS, Diedrich PR. Biomechanics of a Distal Jet appliance. Angle Orthod. 2008 Jul;78(4):676-81. evaluated the biomechanics of a distal jet appliance, indicating that a -21 cN intrusive force acted on the upper first molar during distalization. This force remained stable until 1-mm of distal movement, after which it consistently dropped.
In our study, when the force passed near the CRes of the first molar, we observed vertical movement that was statistically insignificant. However, in five cases, when the force passed occlusal to the CRes, we observed significant intrusion along with distal tipping. The occurrence of intrusion during distal tipping of the molar suggests a complex biomechanical interplay. To gain a deeper understanding of this phenomenon, further investigation through finite element analysis is recomended.
In a systematic review, Fiorillo et al.1515 Fiorillo G, Campobasso A, Mariani G, Lo Muzio E, Mandelli G, Gastaldi G. Maxillary molar distalisation using palatal TAD-supported devices in the treatment of Class II malocclusion: a systematic review. Aust Orthod J. 2022 Jul;38(1):202-12. assessed eleven studies and concluded that upper molars can be effectively distalized with Temporary Anchorage Device (TAD)-assisted distalizing appliances, achieving a range of 3.0 to 5.3 mm. Spontaneous distal migration of upper premolars was observed, ranging from 1.65 to 4.30 mm. In our study, distal migration was 0.57mm, but the distal tipping was 5.13°. The only plausible explanation for distal tipping with minor migration is the growth-induced changes observed in the majority of patients included in this study.1616 Baccetti T, Stahl F, McNamara Jr JA. Dentofacial growth changes in subjects with untreated Class II malocclusion from late puberty through young adulthood. Am J Orthod Dentofacial Orthop. 2009 Feb;135(2):148-54. The distal tipping of upper premolars can be attributed to the use of a direct skeletal anchorage system in our study, where premolars were not included in the anchorage unit. They tipped distally due to the stretching of transseptal fibers.1717 Li Y, Jacox LA, Little SH, Ko CC. Orthodontic tooth movement: The biology and clinical implications. Kaohsiung J Med Sci. 2018 Feb;34(4):207-214.
To prevent anchorage loss, the appliance in this study was supported by two palatal miniscrews. Grec et al.44 Grec RH, Janson G, Branco NC, Moura-Grec PG, Patel MP, Castanha Henriques JF. Intraoral distalizer effects with conventional and skeletal anchorage: a meta-analysis. Am J Orthod Dentofacial Orthop. 2013 May;143(5):602-15. concluded in their study that intraoral distalizers with skeletal anchorage, unlike traditional systems, were more effective for molar distalization and showed no anchorage loss. Moreover, the use of direct skeletal anchorage induced spontaneous distal movement of upper premolars. Ludwig et al.1818 Ludwig B, Glasl B, Bowman SJ, Wilmes B, Kinzinger GS, Lisson JA. Anatomical guidelines for miniscrew insertion: palatal sites. J Clin Orthod. 2011 Aug;45(8):433-41;quiz 467. suggested that the anterior palate is a reliable zone for miniscrew insertion. In our study, miniscrews were consistently placed 3-4 mm parasagittal to the midpalatal suture in all patients.
In nine cases, the distance U1 CEJ./PTV was increased; and in six cases, U1/SN angle was increased. Given the use of direct skeletal anchorage, the only plausible explanation for the increase in results could be the growth-induced changes and possible errors during measurements.1616 Baccetti T, Stahl F, McNamara Jr JA. Dentofacial growth changes in subjects with untreated Class II malocclusion from late puberty through young adulthood. Am J Orthod Dentofacial Orthop. 2009 Feb;135(2):148-54.
Another possible reason could be the fact that in several cases brackets were bonded to upper teeth before the completion of distalization.
Another important factor that needs consideration during distalization is the stiffness of the distalizing appliance.
In their systematic review, Ceratti et al.1919 Ceratti C, Serafin M, Del Fabbro M, Caprioglio A. Effectiveness of miniscrew-supported maxillary molar distalization according to temporary anchorage device features and appliance design: systematic review and meta-analysis. Angle Orthod. 2024;94(1):107-121. compared rigid and non-rigid distalizers, and concluded that non-rigid appliances tipped upper molars more than rigid appliances, although the amounts of molar distalization and intrusion were similar. In our study, we utilized 12-mm expansion screws (Dentaurum, Variety SP®). According to the manufacturer, the expansion per turn is 0.8 mm. Lombardo et al.2020 Lombardo L, Sacchi E, Larosa M, Mollica F, Mazzanti V, Spedicato GA, et al. Evaluation of the stiffness characteristics of rapid palatal expander screws. Prog Orthod. 2016 Dec;17(1):36., comparing different palatal expanders, reported that the Dentaurum Variety SP® screw body size was 9.6 × 5 × 3mm, with a maximum expansion of 12 mm, and an arm diameter of 1.48 mm. From the initial activations, the screw exerted a force of 302 N (Newtons), and after 10 and 15 activations, it remained over 250 N. The stiffness of the screw remained high after 6-8 activations. This could be another explanation for the very small amount of distal tipping observed in five patients. Moreover, the stiffness of the “system” allowed us to use Class III elastics (as anchorage for lower molar uprighting mechanics, when necessary) or other elastic module from upper first molars, for the retraction of upper premolars and canines without fear of mesial tilting of upper molars.
In a study by Cozzani et al.1212 Cozzani M, Pasini M, Zallio F, Ritucci R, Mutinelli S, Mazzotta L, et al. Comparison of maxillary molar distalization with an implant-supported distal jet and a traditional tooth-supported distal jet appliance. Int J Dent. 2014:2014:937059., the mean distalization time was 9.1 ± 2.8 months. Kinzinger et al.33 Kinzinger GS, Gülden N, Yildizhan F, Diedrich PR. Efficiency of a skeletonized distal jet appliance supported by miniscrew anchorage for noncompliance maxillary molar distalization. Am J Orthod Dentofacial Orthod. 2009 Oct;136(4):578-86. reported a treatment duration of 6.7 months. The average distalization time with the Dual-force distalizer (DFD) was 5 months.2121 Oberti G, Villegas C, Ealo M, Palacio JC, Baccetti T. Maxillary molar distalization with the dual-force distalizer supported by mini-implants: A clinical study. Am J Orthod Dentofacial Orthop. 2009;135(3):282.e1-5; discussion 282-3. In our study, the mean distalization time was 6.8 months.
Kinzinger et al.33 Kinzinger GS, Gülden N, Yildizhan F, Diedrich PR. Efficiency of a skeletonized distal jet appliance supported by miniscrew anchorage for noncompliance maxillary molar distalization. Am J Orthod Dentofacial Orthod. 2009 Oct;136(4):578-86. reported mean increase in transverse width of 1.79 ± 1.08 mm between the mesiobuccal cusps, 2.58 ± 0.69 mm between the central fossae, and 3.03 ± 0.68 mm between the distobuccal cusps. Additionally, the upper first molar rotated mesiopalatally a mean of 8.35 ± 7.66° on the right side and 7.88 ± 5.50° on the left side.
Kircali et al.2222 Kircali M, Yüksel AS. Evaluation of dentoalveolar and dentofacial effects of a mini-screw-anchored pendulum appliance in maxillary molar distalization. Turk J Orthod. 2018 Dec;31(4):103-109. reported an increase in the distance between mesiobuccal cusps of the upper first molars by 2.4 mm, along with insignificant mesiopalatal rotations of the upper first molars.
Kinzinger et al. 66 Kinzinger GS, Diedrich PR. Biomechanics of a Distal Jet appliance. Angle Orthod. 2008 Jul;78(4):676-81., when evaluating the biomechanics of the distal jet appliance, stated that, due to the force passing palatal to the CRes of the upper first molars, they experienced a mesially rotating moment, that decreased during the course of distalization (700 cN/mm initially; 200 cN mm after 3 mm).
Kang et al.2323 Kang JM, Park JH, Bayome M, Oh M, Park CO, Kook YA, et al. A three-dimensional finite element analysis of molar distalization with a palatal plate, pendulum, and headgear according to molar eruption stage. Korean J Orthod. 2016 Sep;46(5):290-300. compared the results of distalization of the first molars with a modified palatal anchorage plate (MPAP) and a miniscrew-anchored pendulum appliance. They stated that in both methods, distalization was accompanied by intrusion, buccal tipping, and mesial-in rotation.
Increase in intermolar width in our study was similar to the results of above-mentioned studies, but despite our efforts to mitigate rotational effects during molar distalization, by employing a distalizing mechanism designed to be rigid and resistant, we observed a mean rotation of 4.1°(p<0.05) for the upper right molars and 3.4°(p<0.05) for the upper left molars. These findings indicate that, while our approach aimed to provide stability and prevent undesired molar rotation, some degree of rotational movement still occurred during the treatment, due to palatally acting force. Further investigation is recommended to better understand the factors contributing to this rotational effect and to refine treatment protocols accordingly.
CONCLUSION
This study demonstrates the effectiveness of the palatal distalizer with Variety SP® screws for bilateral molar distalization without anchorage loss. Careful planning of the line of the acting force during appliance fabrication is crucial.
-
» When the force passes near the center of resistance (CRes) of the upper first molars, the orthodontist can expect distal movement with minor distal tipping in the sagittal plane, due to the stiffness of the system, even if second molars are in the germinating stage and can act as a fulcrum.
-
» When the force is applied near the CRes of the upper first molar, minimal vertical changes occur.
-
» When the force passes occlusally beyond the CRes, it induces significant distal tipping and intrusion.
-
» Due to the force acting palatally to the center of resistance of the upper first molars, some degree of mesial-inward rotation of the molars took place.
The results are based on records of only seventeen patients, needing further investigation with a larger sample size. Future research should specifically address upper first molar torque changes, second molar movement, the amount of acting force, and the effect of upper third molars on distalization.
REFERENCES
-
1Byloff FK, Darendeliler MA. Distal molar movement using the pendulum appliance. Part 1: Clinical and radiological evaluation. Angle Orthod. 1997;67(4):249-60.
-
2Bussick TJ, McNamara Jr JA. Dentoalveolar and skeletal changes associated with the pendulum appliance. Am J Orthod Dentofacial Orthod. 2000 Mar;117(3):333-43.
-
3Kinzinger GS, Gülden N, Yildizhan F, Diedrich PR. Efficiency of a skeletonized distal jet appliance supported by miniscrew anchorage for noncompliance maxillary molar distalization. Am J Orthod Dentofacial Orthod. 2009 Oct;136(4):578-86.
-
4Grec RH, Janson G, Branco NC, Moura-Grec PG, Patel MP, Castanha Henriques JF. Intraoral distalizer effects with conventional and skeletal anchorage: a meta-analysis. Am J Orthod Dentofacial Orthop. 2013 May;143(5):602-15.
-
5Acar AG, Gürsoy S, Dinçer M. Molar distalization with a pendulum appliance K-loop combination. Eur J Orthod. 2010 Aug;32(4):459-65.
-
6Kinzinger GS, Diedrich PR. Biomechanics of a Distal Jet appliance. Angle Orthod. 2008 Jul;78(4):676-81.
-
7Ohmae M, Saito S, Morohashi T, Seki K, Qu H, Kanomi R, et al. A clinical and histological evaluation of titanium mini-implants as anchors for orthodontic intrusion in the beagle dog. Am J Orthod Dentofacial Orthop. 2002 May;119(5):489-497.
-
8Vande Vannet B, Sabzevar MM, Wehrbein H, Asscherickx K. Osseointegration of miniscrews: a histomorphometric evaluation. Eur J Orthod. 2007 Oct;29(5):437-42.
-
9Gandhi V, Luu B, Dresner R, Pierce D, Upadhyay M. Where is the center of resistance of a maxillary first molar? A 3-dimensional finite element analysis. Am J Orthod Dentofacial Orthop. 2021 Sep;160(3):442-50.e1.
-
10Kinzinger GS, Fritz UB, Sander FG, Diedrich PR. Efficiency of a pendulum appliance for molar distalization related to second and third molar eruption stage. Am J Orthod Dentofacial Orthop. 2004 Jan;125(1):8-23.
-
11Kircali M, Yüksel AS. Evaluation of dentoalveolar and dentofacial effects of a mini-screw-anchored pendulum appliance in maxillary molar distalization. Turk J Orthod. 2018 Dec;31(4):103-9.
-
12Cozzani M, Pasini M, Zallio F, Ritucci R, Mutinelli S, Mazzotta L, et al. Comparison of maxillary molar distalization with an implant-supported distal jet and a traditional tooth-supported distal jet appliance. Int J Dent. 2014:2014:937059.
-
13Chiu PP, McNamara Jr JA, Franchi L. A comparison of two intraoral molar distalization appliances: Distal jet versus pendulum. Am J Orthod Dentofacial Orthop. 2005 Sep;128(3):353-65.
-
14Tekale PD, Patil HA, Garg K, Kerudi VV, Parhad SM, Sharan JS, et al. A three-dimensional finite element analysis of mini-implant supported K-loop for maxillary molar distalization. J Indian Orthod Soc. 2023;57(2):62-9.
-
15Fiorillo G, Campobasso A, Mariani G, Lo Muzio E, Mandelli G, Gastaldi G. Maxillary molar distalisation using palatal TAD-supported devices in the treatment of Class II malocclusion: a systematic review. Aust Orthod J. 2022 Jul;38(1):202-12.
-
16Baccetti T, Stahl F, McNamara Jr JA. Dentofacial growth changes in subjects with untreated Class II malocclusion from late puberty through young adulthood. Am J Orthod Dentofacial Orthop. 2009 Feb;135(2):148-54.
-
17Li Y, Jacox LA, Little SH, Ko CC. Orthodontic tooth movement: The biology and clinical implications. Kaohsiung J Med Sci. 2018 Feb;34(4):207-214.
-
18Ludwig B, Glasl B, Bowman SJ, Wilmes B, Kinzinger GS, Lisson JA. Anatomical guidelines for miniscrew insertion: palatal sites. J Clin Orthod. 2011 Aug;45(8):433-41;quiz 467.
-
19Ceratti C, Serafin M, Del Fabbro M, Caprioglio A. Effectiveness of miniscrew-supported maxillary molar distalization according to temporary anchorage device features and appliance design: systematic review and meta-analysis. Angle Orthod. 2024;94(1):107-121.
-
20Lombardo L, Sacchi E, Larosa M, Mollica F, Mazzanti V, Spedicato GA, et al. Evaluation of the stiffness characteristics of rapid palatal expander screws. Prog Orthod. 2016 Dec;17(1):36.
-
21Oberti G, Villegas C, Ealo M, Palacio JC, Baccetti T. Maxillary molar distalization with the dual-force distalizer supported by mini-implants: A clinical study. Am J Orthod Dentofacial Orthop. 2009;135(3):282.e1-5; discussion 282-3.
-
22Kircali M, Yüksel AS. Evaluation of dentoalveolar and dentofacial effects of a mini-screw-anchored pendulum appliance in maxillary molar distalization. Turk J Orthod. 2018 Dec;31(4):103-109.
-
23Kang JM, Park JH, Bayome M, Oh M, Park CO, Kook YA, et al. A three-dimensional finite element analysis of molar distalization with a palatal plate, pendulum, and headgear according to molar eruption stage. Korean J Orthod. 2016 Sep;46(5):290-300.
-
»
Patients displayed in this article previously approved the use of their facial and intraoral photographs.
Publication Dates
-
Publication in this collection
10 June 2024 -
Date of issue
2024
History
-
Received
29 Nov 2023 -
Accepted
25 Mar 2024