Acessibilidade / Reportar erro

Horizontal gaze palsy and progressive scoliosis: magnetic resonance imaging features and surgical treatment

A 13-year-old patient was referred for surgical treatment of scoliosis. Her neurological examination revealed the complete loss of horizontal eye movements with normal vertical gaze, suggesting diagnosis of horizontal gaze palsy and progressive scoliosis. The magnetic resonance imaging revealed a hypoplastic pons and medulla with a prominent midline cleft, therefore resulting in characteristic “butterfly” configuration.(11. Bomfim RC, Távora DG, Nakayama M, Gama RL. Horizontal gaze palsy with progressive scoliosis: CT and MR findings. Pediatr Radiol. 2009;39(2):184-7. Review.) The tractography showed absence of major crossing pathways within the pons and midbrain, and normal interhemispheric connections in the corpus callosum (Figure 1). Surgical treatment for scoliosis was performed successfully (Figure 2).

Figure 1
Pre-operative images. (A to D) Magnetic resonance imaging axial T2 shows the hypoplastic pons and medulla with a prominent midline cleft. (E and F) Magnetic resonance imaging sagittal T2 of the brain shows depression of the floor of the fourth ventricle. The pons and medulla oblongata have a reduced volume. (G and H) Magnetic resonance imaging coronal T2. (I) Tractography showed no crossing over of major fibers at the level of pons

Figure 2
Operative findings. (A and B) Vertical eye movements within normal limits. (C) Absence of surgical features of horizontal eye movements. (D) Exposure of thoracic spine scoliosis with left convexity. (E) Posterior spinal fusion from the second to the eleventh thoracic level. (F) The anteroposterior radiograph before surgery. (G) The anteroposterior radiograph after surgery, showed degree of coronal balance and correction obtained

Horizontal gaze palsy with progressive scoliosis is a rare autosomal recessive disorder characterized by congenital absence of normal horizontal eye movements and progressive scoliosis during childhood and adolescence. Heterozygous mutations in ROBO3 are reported as a cause of this disorder.(22. Chan WM, Traboulsi EI, Arthur B, Friedman N, Andrews C, Engle EC. Horizontal gaze palsy with progressive scoliosis can result from compound heterozygous mutations in ROBO3. J Med Genet. 2006;43(3):e11.)

REFERÊNCIAS

  • 1
    Bomfim RC, Távora DG, Nakayama M, Gama RL. Horizontal gaze palsy with progressive scoliosis: CT and MR findings. Pediatr Radiol. 2009;39(2):184-7. Review.
  • 2
    Chan WM, Traboulsi EI, Arthur B, Friedman N, Andrews C, Engle EC. Horizontal gaze palsy with progressive scoliosis can result from compound heterozygous mutations in ROBO3. J Med Genet. 2006;43(3):e11.

Publication Dates

  • Publication in this collection
    17 Aug 2017
  • Date of issue
    Oct-Dec 2017

History

  • Received
    16 Dec 2016
  • Accepted
    8 Apr 2017
Instituto Israelita de Ensino e Pesquisa Albert Einstein Avenida Albert Einstein, 627/701 , 05651-901 São Paulo - SP, Tel.: (55 11) 2151 0904 - São Paulo - SP - Brazil
E-mail: revista@einstein.br