Bactericidal effect of high frequency generator in Staphylococcus aureus culture

The purpose of this study was to check the bactericidal effect of the high frequency generator over the Staphylococcus aureus culture. A total of 36 Petri dishes inoculated with Staphylococcus aureus were divided into 6 groups, including 4 treated (G5-15, G5-10, G3-15 and G3-10) and 2 controls (GC3 e GC5). G5-15 and G5-10 were treated 5 times per week during 15 and 10 minutes, respectively, while G3-15 and G3-10 were treated 3 times per week during 15 and 10 minutes, respectively. In treatment, it was used the high frequency generator with intensity of 10, sparking technique with standard electrode. After the 15th day of treatment, there were performed transplanting, in order to check if there were growth of new cultures, and only G5-15 showed to be effective when compared to GC5 (p=0.0039). So, the high frequency generator had a bactericidal effect on Staphylococcus aureus in vitro culture at a frequency of 5 times per week and exposure time of 15 minutes daily.