OBJECTIVE:This study aimed at evaluating the degree of conversion (DC) of four composite resins, being one nanofilled and 3 microhybrid resins, photo-activated with second- and third-generation light-emitting diodes (LEDs). MATERIAL AND METHODS: Filtek TM Z350 nanofilled composite resins and Amelogen® Plus, Vit-l-escenceTM and Opallis microhybrid resins were photo-activated with two second-generation LEDs (Radii-cal and Elipar Free LightTM 2) and one third-generation LED (Ultra-Lume LED 5) by continuous light mode, and a quartz halogen-tungsten bulb (QHT, control). After 24 h of storage, the samples were pulverized into fine powder and 5 mg of each material were mixed with 100 mg of potassium bromide (KBr). After homogenization, they were pressed, which resulted in a pellet that was evaluated using an infrared spectromer (Nexus 470, Thermo Nicolet) equipped with TGS detector using diffuse reflectance (32 scans, resolution of 4 cm-1) coupled to a computer. The percentage of unreacted carbon-carbon double bonds (% C=C) was determined from the ratio of absorbance intensities of aliphatic C=C (peak at 1637 cm-1) against internal standard before and after curing of the specimen: aromatic C-C (peak at 1610 cm-1). RESULTS: The ANOVA showed a significant effect on the interaction between the light-curing units (LCUs) and the composite resins (p<0.001). The Tukey’s test showed that the nanofilled resin (FiltekTM Z350) and Opallis when photo-activated by the halogen lamp (QTH) had the lowest DC compared with the other microhybrid composite resins. The DC of the nanofilled resin (FiltekTM Z350) was also lower using LEDs. The highest degrees of conversion were obtained using the third-generation LED and one of second-generation LEDs (Elipar Free LightTM 2). CONCLUSIONS: The nanofilled resin showed the lowest DC, and the Vit-l-escenceTM microhybrid composite resin showed the highest DC. Among the LCUs, it was not possible to establish an order, even though the second-generation LED Radii-cal provided the lowest DC.
Composite resins; Fourier transform infrared spectroscopy; Nanotechnology; Light
ORIGINAL ARTICLES
Degree of conversion of nanofilled and microhybrid composite resins photo-activated by different generations of LEDs
Benicia Carolina Iaskieviscz RibeiroI; Juliana Maria Capelozza BoaventuraII; Joel de Brito-GonçalvesIII; Alessandra Nara de Souza RastelliIV; Vanderlei Salvador BagnatoV; José Roberto Cury SaadIV
IDDS, MSc, PhD Professor, Dental School Prof. Albino Coimbra Filho, Federal University of Mato Grosso do Sul, Campo Grande, MS, Brazil
IIDDS, MSc, PhD student, Department of Restorative Dentistry, Araraquara School of Dentistry, UNESP - Univ. Estadual Paulista , Araraquara, SP, Brazil
IIIDDS, Dental School Prof. Albino Coimbra Filho, Federal University of Mato Grosso do Sul, Campo Grande, MS, Brazil
IVDDS, MSc, PhD, Assistant Professor, Department of Restorative Dentistry, Araraquara School of Dentistry, UNESP - Univ. Estadual Paulista , Araraquara, SP, Brazil
VDDS, MSc, PhD, Full Professor, Biophotonics Laboratory, Physics Institute of São Carlos, University of São Paulo, São Carlos, SP, Brazil
Corresponding address Corresponding address: Benicia Carolina Iaskieviscz Ribeiro Rua Goiás, 449 - Jardim dos Estados Campo Grande - MS - Brazil - 79.020-100 Phone:+55 67 3326-1480 e-mail: becarol.odonto@uol.com.br
ABSTRACT
OBJECTIVE:This study aimed at evaluating the degree of conversion (DC) of four composite resins, being one nanofilled and 3 microhybrid resins, photo-activated with second- and third-generation light-emitting diodes (LEDs).
MATERIAL AND METHODS: Filtek TM Z350 nanofilled composite resins and Amelogen® Plus, Vit-l-escenceTM and Opallis microhybrid resins were photo-activated with two second-generation LEDs (Radii-cal and Elipar Free LightTM 2) and one third-generation LED (Ultra-Lume LED 5) by continuous light mode, and a quartz halogen-tungsten bulb (QHT, control). After 24 h of storage, the samples were pulverized into fine powder and 5 mg of each material were mixed with 100 mg of potassium bromide (KBr). After homogenization, they were pressed, which resulted in a pellet that was evaluated using an infrared spectromer (Nexus 470, Thermo Nicolet) equipped with TGS detector using diffuse reflectance (32 scans, resolution of 4 cm-1) coupled to a computer. The percentage of unreacted carbon-carbon double bonds (% C=C) was determined from the ratio of absorbance intensities of aliphatic C=C (peak at 1637 cm-1) against internal standard before and after curing of the specimen: aromatic C-C (peak at 1610 cm-1).
RESULTS: The ANOVA showed a significant effect on the interaction between the light-curing units (LCUs) and the composite resins (p<0.001). The Tukeys test showed that the nanofilled resin (FiltekTM Z350) and Opallis when photo-activated by the halogen lamp (QTH) had the lowest DC compared with the other microhybrid composite resins. The DC of the nanofilled resin (FiltekTM Z350) was also lower using LEDs. The highest degrees of conversion were obtained using the third-generation LED and one of second-generation LEDs (Elipar Free LightTM 2).
CONCLUSIONS: The nanofilled resin showed the lowest DC, and the Vit-l-escenceTM microhybrid composite resin showed the highest DC. Among the LCUs, it was not possible to establish an order, even though the second-generation LED Radii-cal provided the lowest DC.
Key words: Composite resins. Fourier transform infrared spectroscopy. Nanotechnology. Light.
INTRODUCTION
Although widely used in diverse industries such as biomedicine, electronics, aerospace, and means of transportation, it is only recently that nanotechnology has begun to be applied to Dentistry8. Due to their small size, it is possible to incorporate more filler content on composite resins based on this technology10, which results in better mechanical properties8. Their optical properties are also improved, since the diameter of its particles is a fraction of a visible light wavelength, and the human eye cannot distinguish them8.
Given its many deficiencies, such as short life and heat production5, quartz-tungsten halogen (QTH) lamps are being replaced by other light sources, especially light-emitting diodes (LEDs). Technical advancements in LED light-curing units (LCUs) have occurred rapidly since their introduction to Dentistry, and second-generation blue LED systems are capable of performing equal to QTH LCUs17. The first-generation units consisted of an array of relatively low-powered chips offering a comparative low output and poor curing performance compared with QTH LCUs15. Second-generation models demonstrate better performance, using a single chip of much higher surface area that emits only one color range of grealy incresead output power26. Currently, the LEDs systems are already in their third generation, characterized by the presence of the same chip used by the second-generation systems plus other low-powered chips which will emit a second frequency in the violet spectral range17.
Composite resins with polymer matrices that exhibit bifunctional monomers (Bis-GMA, Bis-EMA, TEGDMA) whose polymerization reaction generates glassy polymers with dense cross-linked networks23. Ideally, composites should have most of their monomers converted into polymers during polymerization. Resin-based material polymerization involves free radical reaction in which the material is transformed from a viscous to a rigid state. During this process, the terminal aliphatic C=C bonds are broken and converted to primary C-C covalent bonds between methacrylate monomers. As polymerization progresses, however, the diffusion rate of the propagating free radicals undergoes a strong reduction. Thus, monomer conversion is not complete and, at the end of the reaction, part of the monomers remains as pendant double bonds or unreacted monomers trapped in the polymeric matrix12. Nevertheless, the dimethacrylate polymers exhibit considerable residual unsaturation in the final product, with a degree of conversion (DC) ranging from 55 to 75%6,19. The literature shows that the formation mechanism of free radical in the polymer varies with the photoinitiator system used25. Authors like Conti, et al.2 (2005) consider that the emission spectra of LCUs and absorption photoinitiators are essential for adequate polymerization.
The physical and mechanical properties of photo-cured composites are directly influenced by the level of conversion achieved during polymerization9. Lower degree of conversion provides composites with inferior mechanical properties and greater discoloration and degradation20 and as a result, restorations with poor wear resistance and poor color permanence18.
The purpose of this study was to investigate the influence of different light sources - three LEDs, two of the second and one of the third generations on the DC of nanofilled and microhybrid composite resins.
MATERIAL AND METHODS
Composite resins
A nanofilled composite resin (FiltekTM Z350) and three microhybrid composite resins (Amelogen® Plus, Vit-l-escenceTM and Opallis), all indicated for dentin at shade A2, were used. The characteristics and manufacturers of the composite resins can be seen in Figure 1.
Light-curing units
Two second-generation LEDs - Radii-cal (SDI Dental Product SDI , Bayswater, Vitoria, Australia) and Elipar Free LightTM 2 (3M ESPE Dental Products, St. Paul, MN, USA) - and one third-generation LED - Ultra-Lume LED 5 (Ultradent, South Jordan UTAH, USA) - were used. A halogen LCU (Ultralux; Dabi Atlante, Ribeirão Preto, SP, Brazil) was used as the control group. The power was measured before specimen preparation at the end of the light-guide tip of all LCUs with a power meter (Fieldmaster, Coherent Commercial Products Division, Santa Clara, CA, USA, model FM, series 11M96) and the power density values were calculated using the equation: ,where P is the power, in milliwatts, and A is the light tip area, in square centimeters.
Figure 2 shows the the main characteristics of the LCUs used in this study.
Specimen preparation
To obtain the samples, a circular matrix of aluminum with an external diameter of 2.5 cm and a central diameter of 4 mm, and depth of 2 mm was used. A mylar strip was placed on a glass plate, and the matrix was positioned over that. Using a CIGFTMIN 3 spatula (Oraltech, São Paulo, SP, Brazil), the composite resin was placed in the central orifice in a single increment. A second mylar strip was placed over the composite resin and another glass plate was slightly compressed in order to regularize the external surface of the samples.
The light-guide tips of the LCUs were placed over the matrix containing the composite resin at a standardized distance of 2 mm from the top surface of the material and photo-activation was done during 40 s16. After photo-activation, the specimens were stored under dry conditions at room temperature in light-proof containers4, and identified according to the study groups.
After 24 h, the composite resin was pulverized into fine powder. The pulverized composite resin was maintained in a dark room until the moment of the Fourier transform-infrared spectroscopy (FT-IR) analyses. Five milligrams of the ground powder were thoroughly mixed with 100 mg of KBr powder salt. This mixture was placed into a pelleting device and then pressed in a press with a load of 10 tons during 1 min to obtain a pellet17.
Determination of the DC (% DC)
The number of double-carbon bonds that are converted into single bonds provides the DC (% DC) of the composite resin. To measure the DC, the pellet was placed into a holder attachment into the spectrometer (Nexus 470 Thermo Nicolet, Vernon Hills, IL, USA). For this technique, the samples were made and analyzed 24 h after the photo-activation. The FT-IR spectra of both uncured and cured samples were analyzed using an accessory of the diffuse reflectance. The measurements were recorded in the absorbance operating under the following conditions: 32 scans, a 4 cm-1 resolution, and a 300 to 4000 cm1 wavelength. The percentage of unreactive carboncarbon double bonds (% C=C) was determined from the ratio of the absorbance intensities of aliphatic C=C (peak at 1638 cm1) against an internal standard before and after the curing of the specimen: aromatic CC (peak at 1608 cm1). The DC was determined by subtracting the % C=C from 100%, according to the equation:
eqc01
The assessment of the DC was carried out by two-way analysis of variance (ANOVA). Multiple comparisons of DC means by the Tukeys test followed the analysis. All statistical analyses were performed at a 5% significance level.
RESULTS
There was a significant effect on the interaction between the light-curing units (LCUs) and the composite resins (p<0.001). As can be seen in Table 1, the nanofilled FiltekTM Z350 composite resin showed the lowest DC for all light-curing units used. The lowest DC was obtained with the use of second-generation LED Raddi-cal (49.77%), while the best performance was achieved with the use of the QTH (55.36%), but without a statistically significant difference when compared with the third-generation LED Ultra-Lume LED 5 (54.71%). The microhybrid resins Opallis and Amelogen® Plus had intermediate values for all LCUs used. The highest percentage of conversion of monomers into polymer composite was obtained with Vit-l-escenceTM microhybrid resin photoactivated with any of the LCUs. However no statistically significant difference was observed for Elipar Free LightTM 2 (69.70%) and Ultralux (67.82%). Comparisons among the DC mean values according to the LCUs were as follows: Ultralux (FiltekTM Z350=Opallis®<Amelogen Plus® <Vit-l-escenceTM), Ultra-Lume LED 5 (FiltekTM Z350<Opallis®=Amelogen Plus®<Vit-l-escenseTM), Radii-Cal (FiltekTM Z350<Opallis®=Amelogen Plus®<Vit-l-escenceTM) and Elipar Free LightTM 2 (FiltekTM Z350<Opallis®=Amelogen Plus®<Vit-l-escenceTM).
It is possible to state that, independent of the LCU, the composite resins can be arranged in a crescent order according to their DC mean values: FiltekTM Z350≤Opallis≤Amelogen® Plus<Vit-l-escenceTM. Among the LCUs it was not possible to establish any order according to the DC mean values.
DISCUSSION
The size of the charged particle and the refractive index, the densities of restorative materials, the nature of polymer matrix and the irradiance time generated by the method of polymerization can influence the DC of dental composite. There is consensus in the literature20,21 that when inadequate levels of conversion are achieved in the polymerization reaction, the mechanical properties and abrasion resistance performance can be compromised, and color stability may decline20.
It is known that physical properties of light-cured composites may change according to the distance from the irradiated surface and, to minimize the chances of interference in this study, the space between the light guide tip and the samples was set at 2 mm24. This distance was chosen because the authors5 consider it the shortest distance between the LCU light-guide tip and the bottom of a Class I composite restoration. FT-IR was chosen to analyze the DC because it is an efficient and frequently used technique13,21 and provides a better understanding of these materials, which is expected to optimize the polymerization process9. Infrared or heat radiation is an electromagnetic radiation invisible to the human eye which limits the length of the visible spectrum from 750 µm to 0.5 mm and triggers both the vibration and rotation of molecules. This spectroscopy is based on the fact that molecules absorb electromagnetic radiation in the IR region. These reactive molecules are related to the presence of individual functional groups that give rise to absorption bands in certain defined areas of the spectrum27.
In a recent study14, results for DC, when one composite resin was light-cured with LED were significantly higher than those obtained with halogen light curing, which can be explained by their wavelengths24. However, the difference in our study was caused not only by the wavelength, but probably also by the different irradiance emitted by LCUs or even the organic components of the composite resins. Unlike Polydorou, et al.14 (2008)study, we found that the halogen light (QTH) provided the best results for the nanofilled resin. Probably, the heat generated by the QTH lamp has influenced the conversion of monomers into polymers. The gradual increase in temperature influences the polymerization reaction3 although the heat produced by halogen LCUs may cause deleterious effects to the pulp16. However, other studies are necessary to elucidate this fact because this result did not happen with the other composites. It is likely that the exposure time and power density and consequently energy density can be related with the results obtained in this study6,10.
Nonetheless, when the nanofilled and microhybrid composites were compared, the DC of the first one was lower than that of the other resins light-cured by all LCUs used in this study. These results are in accordance with those obtained by Silva, et al.22 (2008) and Halvorson, et al.5 (2002) in which the nanofilled resin showed a lower DC. A possible explanation for this performance may be related to the difference in the composition of the organic matrix, size, volume and type of particles that interfere with the depth of cure and different spread pattern of incident light7. The particles can cause an effect of dispersing the light because as light passes through the increasing density of the material, its light intensity is reduced28. It is greatly outstanding that the results with the nanofilled resin showed the lowest DC among all composites that were analyzed in this study, which is similar to the results obtained by Silva, et al.22 (2008). Those authors22 showed that non-agglomerated silica nanoparticles with mean size of 20 nm may have caused a light-scattering effect in nanofilled composite. Thus, the power density might have been attenuated and the DC decreased. On the other hand, in the microhybrid composite, light transmittance was probably higher, which can explain the results obtained in this investigation.
When Opallis composite resin was light-cured with Elipar Free LightTM 2 and Ultra Lume LED 5 it was observed the highest DC mean values. Amelogen® Plus showed no statistically significant differences when light-cured by three of the four LCUs (Ultralux QTH, LEDs Ultra Lume LED 5 and Elipar Free LightTM 2). Its lower performance occurred when LED Raddi-cal was used.
The highest conversion of monomers into polymers was observed for Vit-l-escenceTM composite resin irrespective of the LCU, with a slight increase when Elipar Free LightTM 2 was used. However, all composite resins showed a lower DC when light-cured with Radii-Cal. In spite of these results, it is known that blue LEDs have the advantage of a narrower spectral range than QTH lamps and a better connection between the emitted light and the absorption and photoinitiator camphorquinone11. In this particular case, there was a slight decline in LED ability to convert monomers into polymers, when compared with the other LCUs used in this study.
According to Nitta10 (2005), the light-guide tip diameter can influence the DC. This author10 found that the irradiation emitted by a 4-mm-diameter tip was approximately twice that of a 8-mm-diameter tip and three times that of a 10-mm-diameter tip because the light beam may be scattered depending on the type of guide and optical fiber. However, in this study, different sizes of light-guide tips (7, 8 and 13 mm) were used and the lowest DC value was obtained with the LED Raddi-cal, which has the smallest tip diameter and has a narrower range of light spectrum (440-480 nm), allowing a better use of the light emitted1. This LED provides an intensity of 970 mW/cm2, which is higher than the one from third-generation LED (800 mW/cm2), and slightly lower than the one from the other second-generation LED (Elipar Free LightTM 2), with 980 mW/cm2.
In this study, the irradiation time was constant for all LCUs (40 s) but, as shown in Figure 2, the wavelength range, power density, tip diameter were different for the different LCUs. According to Nitta10 (2005) the light-guide tip diameter influenced the power density values and the DC mean values. In this study, it was observed that the different dimensions of the light-guide tips did not show statistically significant differences, although the LED with the smallest light-guide tip showed the least performance.
Considering the results obtained in this study, further research is needed in order to elucidate the behavior of nanofilled composites when light-cured with different LCUs.
CONCLUSION
Based on the results obtained in this study, among the LCUs used, it was not possible to establish an order, even though the second-generation LED Raddi-cal showed the lowest DC mean values, regardless of the composite resin used. The LCUs did not influence on the final DC of the different composite resins. The microhybrid resin photoactivated with Elipar Free LightTM 2 second-generation LED presented the lowest DC mean values. Among the composite resins, FiltekTM Z350 showed the lowest DC and Vit-l-escenceTM microhybrid composite resin showed the highest DC.
ACKNOWLEDGEMENTS
In memoriam: Profs. Drs. Maria Salete Machado Candido, UNESP - Univ. Estadual Paulista, Araraquara School of Dentistry, Araraquara, SP, Brazil.
Denis Pablo Jacomassi, Ph.D student in Physics and Materials Science, University of São Paulo, Physics Institute of São Carlos, Optical Group, Biophotonics Laboratory, São Carlos, SP, Brazil for his unconditional support to this study.
3M ESPE Brazil, Dabi-Atlante representative Odontopan and Dr. Patricia Amaral for supplying equipment.
Received: June 16, 2010
Modification: May 31, 2011
Accepted: July 14, 2011
References
- 1- Asmussen E, Peutzfeldt A. Influence of composition on rate of polymerization contraction of light-curing resin composites. Acta Odontol Scand. 2002;60:146-50.
- 2- Conti C, Giorginni E, Landi L, Putignano A, Tosi G. Spectroscopic and mechanical properties of dental resin composites cured with different light sources. J Mol Struct. 2005;744-747(Spec. Iss.):641-6.
- 3- Cunha LG, Alonso RC, Neves AC, Goes MF, Ferracane JL, Sinhoreti MA. Degree of conversion and contraction stress development of a resin composite irradiated using halogen and LED at two C-factor levels. Oper Dent. 2009;34:24-31.
- 4- Felix CA, Price RB. The effect of distance from light source on light intensity from curing lights. J Adhes Dent. 2003;5:283-91.
- 5- Halvorson RH, Erickson RL, Davidson CL. Energy dependent polymerization of resin-based composite. Dent Mater. 2002;18:463-9.
- 6- Imazato S, McCabe JF, Tarumi H, Ehara A, Ebisu A. Degree of conversion of composites measured by DTA and FTIR. Dent Mater. 2001;17:178-83
- 7- Knezević A, Tarle Z, Meniga A, Sutalo J, Pichler G, Ristić M. Degree of conversion and temperature rise during polymerization of composite resin samples with blue diodes. J Oral Rehabil. 2001:28:586-91.
- 8- Mitra SB, Wu D, Holmes BN. An application of nanotechnology in advanced dental materials. J Am Dent Assoc. 2003;134:1382-90.
- 9- Moraes LGP, Rocha RSF, Menegazzo LM, Araújo EB Yukimitu K, Moraes JCS. Infrared spectroscopy: a tool for determination of the degree of conversion in dental composites. J Appl Oral Sci. 2008;16:145-9.
- 10- Nitta K. Effect of light guide tip diameter of LED-light curing unit on polymerization of light-cured composites. Dent Mater. 2005;21:217-23.
- 11- Nomura Y, Teshima W, Tanaka N, Yoshida Y, Nahara Y, Okazaki M. Thermal analysis of dental resins cured with blue light-emitting diodes (LEDs). J Biomed Mater Res A. 2002;63:209-13.
- 12- Noronha Filho JD, Brandão NL, Poskus LT, Guimarães JGA, Silva EM. A critical analysis of the degree of conversion of resin-based luting cements. J Appl Oral Sci. 2010;18(5):442-6.
- 13- Peutzfeldt A, Asmussen E. Resin composite properties and energy density of light cure. J Dent Res. 2005;84:659-62.
- 14- Polydorou O, Manolakis A, Hellwig E, Hahn P. Evaluation of the curing depth of two translucent composite materials using a halogen and two LED curing units. Clin Oral Investig. 2008;12:45-51.
- 15- Price RB, Felix CA, Andreou P. Evaluation of a dual peak third generation LED curing light. Compend Contin Educ Dent. 2005;26:331-47.
- 16- Rastelli ANS, Jacomassi DP, Bagnato VS. Changes in the temperature of a dental light-cured composite resin by different light-curing units. Laser Phys. 2008;18:1003-7.
- 17- Rueggeberg FA, Blalock JS, Callan RS. LED curing lights - whats new? Compend Contin Educ Dent. 2005;26:586,588,590-1.
- 18- Rueggeberg FA, Caughman WF, Curtis JW Jr. Effect of light intensity and exposure duration on cure of resin composite. Oper Dent.1994;19:26-32.
- 19- Ruyter IE, Oysaed H. Composites for use in posterior teeth: composition and conversion. J Biomed Mater Res A. 1987;21:11-23.
- 20- Schneider LF, Pfeifer CS, Consani S, Prahl SA, Ferracane JL. Influence of photoinitiator type on the rate of polymerization, degree of conversion, hardness and yellowing of dental resin composites. Dent Mater. 2008;24:1169-77.
- 21- Sideridou I, Tserki V, Papanastasiou G. Effect of chemical structure on degree of conversion in light-cured dimethacrylate-based dental resins. Biomaterials. 2002;23:1819-29.
- 22- Silva EM, Almeida GS, Poskus LT, Guimarães JGA. Relationship between the degree of conversion, solubility and salivary sorption of a hybrid and a nanofilled resin composite: influence of the light-activation mode. J Appl Oral Sci. 2008;16:161-6
- 23- Silva PCG, Porto-Neto ST, Lizarelli RFZ, Bagnato VS. Ortodontic brackets removal under shear and tensile bond strength resistance tests a comparative test between light sources. Laser Phys. 2008;5:220-6.
- 24- Stansbury JW, Trujillo-Lemon M, Lu H, Ding X, Lin Y, Ge J. Conversion-dependent shrinkage stress and strain in dental resins and composites. Dent Mater. 2005;21:56-67.
- 25- Sun GJ, Chae KH. Properties of 2,3-butanedione and 1-phenyl-1,2-propanedione as a new photosensitizers for visible light cured dental resin composites. Polymer. 2000;41:6205-12.
- 26- Uhl A, Sigusch BW, Jandt KD. Second-generation LEDs for the polymerization of oral biomaterials. Dent Mater. 2004;20:80-7.
- 27- Wendl B, Droschl H, Kern W. A comparative study of polymerization lamps to determine the degree of cure of composites using infrared spectroscopy. Eur J Orthod. 2004;26:545-51.
- 28- Yap AU, Lee HK, Sabapathy R. Release of methacrylic acid from dental composites. Dent Mater. 2000;16:172-9.
Publication Dates
-
Publication in this collection
31 May 2012 -
Date of issue
Apr 2012
History
-
Received
16 June 2010 -
Accepted
14 July 2011 -
Reviewed
31 May 2011