Acessibilidade / Reportar erro

Physicochemical characterization of six commercial hydroxyapatites for medical-dental applicatons as bone graft

Caracterização físico-química de seis hidroxiapatitas comerciais para aplicações médico-odontológicas como material de enxerto

The aim of this work was to characterize six hydroxyapatites in granular form for applications in medicine and dentistry as bone graft and to compare with manufacturers' specification. These samples were produced by four different manufacturers, and all of them are easily available in the Brazilian market. Physicochemical characterization was carried out by using electron microscopy (SEM), X-ray diffraction (XRD), infrared spectroscopy (FTIR) and surface area (BET) measurements. The results show that just one hydroxyapatite sample exhibited characterisitics in perfect agreement with the manufacturers' specifications. The studied parameters, namely crystallinity, surface area and composition may be used to estimate hydroxyapatite's biodegradability and as a criterion for quality control.

Hydroxyapatite; Calcium phosphate; Bone graft; Physicochemical characterization


Faculdade De Odontologia De Bauru - USP Serviço de Biblioteca e Documentação FOB-USP, Al. Dr. Octávio Pinheiro Brisolla 9-75, 17012-901 Bauru SP Brasil, Tel.: +55 14 32358373 - Bauru - SP - Brazil