Reliability of the measurements of architecture of the Vastus Lateralis muscle by ultrasonography

Reliability of the measurements of the muscle architecture variables by ultrasound are important references for applied studies of muscle mechanics. The aim this study was to analyze the reliability of measurements of Vastus Lateralis (VL) muscle thickness (MT), pennation angle (PA) and fiber length (FL). Ultrasound images were obtained in two days (N=14, 22 ± 1,75 years) with a total of sixty measurements in each subject. Reliability was determined by intraclass correlation coefficient (ICC), coefficient of variation (CV) and typical error of measurement (TEM). Results show high reliability: MT (0,96 a 0,99), PA (0,83 a 0,99) and FL (0,80 a 0,99) ICC; MT (3,12 a 3,84%), PA (3,68 a 6,34%) and FL (3,98 a 6,33%) CV; MT (0,014 a 0,15mm), PA (0,18 a 0,59º) and FL (0,07 a 1,47mm) TEM. These measures should be considered in studies of the impact of conditioning programs in the architecture of the vastus lateralis muscle.

Reliability; Vastus Lateralis; Ultrasound; Muscle Architecture