Acessibilidade / Reportar erro

Comparison Between Graphene Oxides Reduced by Microwave System with Different Power Sets

The present work compares graphene oxides produced by the Marcano's method and the subsequent reduction process using a microwave system with different power and time sets. The thermal profiles of the reduction processes were analyzed, emphasizing the heat capacity from the 600 W test of 3.44 kJ/K. The X-ray diffraction showed a reduction in the interlayer space and the number of layers in all powers. The infrared and UV-Vis spectroscopy results showed a clear decrease in the bands corresponding to the oxygenated group and partial restoration of aromatic bonds. The Raman spectroscopy showed that the 1000 W power set originated a higher defective structure. The observed results allow the conclusion that the 600 W power promotes a little better result between the analyzed power sets.

Keywords:
graphene oxide; microwave reduction; X-ray diffraction; FTIR


ABM, ABC, ABPol UFSCar - Dep. de Engenharia de Materiais, Rod. Washington Luiz, km 235, 13565-905 - São Carlos - SP- Brasil. Tel (55 16) 3351-9487 - São Carlos - SP - Brazil
E-mail: pessan@ufscar.br