Abstract
High density polyethylene and high density polyethylene-clay nanocomposites were produced using direct solvent polymerization and a Ziegler catalyst system (TiCl4 and triethylaluminum in hexane). The produced polymer has a high average molecular weight and a multimodal molecular weight distribution composed of four distributions including a very high molecular weight component. The laboratory polymer has a thermal stability in inert atmosphere similar to the commercial high density polyethylene produced by Braskem. In oxidant atmosphere the produced polymer presents three thermal oxidation events above 400ºC due to the combustion of low, medium and high molecular weight molecules. The thermal oxidation of the nanocomposites is shifted and reduced for high temperatures indicating an improvement in the thermal stability of the polymeric matrix due to the clay barrier effect for gases and volatile compounds.
Keywords: Polyethylene; Nanocomposite; Thermal degradation; Clay; In situ polymerization
1. Introduction
Polymer-clay nanocomposites have received considerable attention in recent years due to their excellent mechanical and barrier properties. Polyolefines-clay nanocomposites are a very promising material, but the non-polar characteristic of these polymers makes the production of nanocomposites a challenging task1,2. Nowadays melt and solution intercalation are the most popular methods for nanocomposite production using a polymeric matrix that contains polar groups3,4,5. However, for a polyolefin matrix the in situ polymerization is the most effective method in clay exfoliation and in the production of nanocomposites1. In this study the production and the thermal stability of high density polyethylene produced using the conventional Ziegler-Natta catalyst system is addressed.
Several studies discuss the thermal stability of polymers in nanocomposites. The thermal degradation of polyethylene-clay nanocomposites produced by melt processing improves the stability and reduces inflammability due to the barrier effect and the charring process1,6. The thermal stability of high density polyethylene-clay nanocomposites produced by in situ polymerization has received less attention and only a few papers discuss this topic.
Jin et al.7 produced polyethylene nanocomposites by in situ polymerization using (i) sodium and (ii) organophilically modified montmorillonites intercalated with TiCl4 and activated by triethylaluminum (TEAL). The results indicated an average molecular weight of 102800 and 204600 and cristallinity of 37 and 34%, respectively. The silicate layers were well dispersed in the polymer matrix.
Ramazani et al.8 produced polyethylene nanocomposites by in situ polymerization using a modified montmorillonite. The clay was activated using triisobutylaluminum (TIBA) or TEAL and after TiCl4 and ethylene was used in the polymerization. They used 2 to 9% clay and the produced polymer had a melting temperature between 132 and 133ºC, crystallinity of 66 to 70%, and exhibited thermal stability until 400ºC.
Nikkhah et al.9 investigated the properties of polyethylene/clay nanocomposites using the in situ polymerization and bi-supported catalyst (bentonite clay and MgCl2/TiCl4). The results indicated that the crystallization temperatures of the nanocomposites were significantly higher than that of pure polyethylene. There was an improvement in the thermal stability of the polymers. The good dispersion and exfoliation of the clay during the polymerization were responsible for obtaining improvements in the reinforcing properties of the clay in the polymer matrix.
Abedi et al.10 produced polyethylene/clay nanocomposites via in situ polymerization using TiCl4, TEAL and organometallic modifier butyloctylmagnesium (BOM) as the catalyst. The clay silicate layers were completely exfoliated in the polymer matrix. The thermal properties of the nanocomposites produced indicated the improved thermal stability of the nanocomposites when compared with pure polyethylene.
The purpose of this work is to produce a high density polyethylene and high density polyethylene-clay nanocomposite using direct solvent polymerization with a Ziegler type catalyst system11, without catalyst support, and to characterize the polymers obtained and their thermal stability.
2. Experimental Procedure
2.1. Materials
The materials used in the present study includes a reference material which was a commercial high density polyethylene produced by Braskem PE2 using the slurry-Mitsubishi process, a Ziegler-Natta catalyst (diethylaluminum chlorid, DEAC), co-catalysts (ethylaluminium sesquichloride, EASC and triethylaluminum, TEAL) and hexane as the solvent. This process uses controlled operating conditions and: i) parallel reactors for the production of the polymer with bimodal molecular weight distribution and ii) reactors in series, for the production of polymers with a monomodal molecular weight distribution. In the present case the sample BS002W is a bimodal resin and the sample JVU060 is a monomodal resin.
For the production of the polymer and nanocomposites the reactants used were: ethylene (99,99%, White Martins SA), solution of TiCl4 (1 mol/L in methylene chloride, Sigma-Aldrich), solution of triethylaluminum (93% Sigma-Aldrich), ethanol (99.99%, Merck), hexane (99.99%, Merck), metallic sodium (99.99%, Merck), benzophenone (99.99%, Merck), nitrogen (99.99 %, White Martins SA) and Nanomer ® I.44 P (Sigma Aldrich), which is 35-45 wt% dimethyl dialkyl (C14-C18) amine montmorillonite clay with particle size finer than 20 µm.
2.2. Production of polymers and nanocomposites
The ethylene polymerization reactions were carried out in a 250 mL stainless steel bench top Parr Instruments stirred reactor (Series 4560), which had a gas inlet, stirring speed adjustment and temperature control. Initially the reactor was purged with N2 and 150 mL of dry hexane was added, then a hexane solution of TiCl4 (0.3 or 0.8 mL of TiCl4 in 10 mL of hexane) and a hexane solution of TEAL was added (0.9, 1.8 or 2.6 mL of TEAL in 10 mL of hexane) as catalyst and co-catalyst. The molar ratio (Al/Ti) was 20 or 29. The injection of ethylene in this system initiated the polymerization that was discontinued after 60 or 90 minutes by reactor depressurizing and the addition of 10 mL of ethanol. The polymerizations were carried out at a temperature between 77 or 85ºC with constant stirring at 190 rpm and pressure between 2.1 and 2.7 bar. The experimental conditions for polymer synthesis, selected according with previous work by Jin et al.7 and Haag and Silva11, are summarized in Table 1. After the reaction ended, the reactor content was filtered at vacuum and washed using ethanol and then distilled water to remove the hexane and catalytic residues. After this, the polymer was dried at 80ºC for 24 hours.
For the synthesis of the nanocomposites three different addition strategies were used:
-
Initially the nanoclay (Nanomer® I44 P) was added to the reactor, then it was purged with N2 and 150 mL of dry hexane was added. It was impregnated by TiCl4 (a solution of 0.6 mL of TiCl4 in 10 mL of hexane) for 60 minutes, then a solution TEAL (1.8 mL in 10 mL of hexane) was added, the following steps are the same as for the production of the polymers described above.
-
Initially the nanoclay was added to the reactor, then it was purged with N2 and 150 mL of dry hexane was added, the following steps are the same as for the production of the polymers described above.
-
Initially the nanoclay was added to the reactor and 150 mL of dry hexane was added. The Lab_Line Ultratip Labsonic System was used to enhance the clay dispersion on the hexane. Then it was purged with N2 and the following steps are the same as for the production of the polymers described above.
The molar ratio (Al/Ti) used in the polymerizations was 29. The experimental conditions for the synthesis of composites and nanocomposites are summarized in Table 2.
2.3. Polymer and nanocomposite characterizations
The catalyst activity or efficiency on the polymerization (rp) was estimated taking into account the mass of polymer produced (mPE), the reaction time (tp) and the amount of titanium used in the reaction (mTi):
The average molecular weight is related to the viscosity of the polymer. In the present study it was estimated using the Braskem method, which is based on the ASTM D-4020 and ISO 1628-3 methods12,13. A Ubbelohd viscosimeter n.1 was used to measure the polymer solution viscosity as a function of the polymer concentration (between 0.01 and 0.02 g/dL in decahydronaphthalene at 135ºC). The specific viscosity (ηsp) is defined as the ratio of the difference between the viscosities of the solution (η) and solvent (ηs) and the viscosity of the solvent:
The relative viscosity (ηrel) is defined as the ratio of the viscosity of the solution to the viscosity of the solvent:
The intrinsic viscosity ([η]) for high density polyethylene is estimated at very low solution concentration using a single concentration and solution viscosity data (C and h) and the ASTM correlation:
The viscosimetric molecular weight of a polymer is close to the average molecular weight and is estimated using the Margolies equation:
The melting temperatures of the polymers were obtained by differential scanning calorimetry (DSC) using the Shimadzu DSC-50, with nitrogen flow at 30 mL/min and a heating rate of 10ºC/min in a temperature range of 30 to 600ºC.
The polymer solid content was evaluated after the thermal degradation of the samples at 600 and 900ºC in an oxidant atmosphere in a laboratory bench Quimis oven. The solid content was characterized using a scanning electron microscope and X-ray spectra (EDS) using the JEOL JSM 6610LV.
The polymer crystallinity (χc) was estimated from the melting enthalpy for the samples ( estimated as the area under the endothermic peak/heating rate) using as reference enthalpy for 100% crystalline high molecular weight polyethylene ( = 293 J/g) as follows:
The thermal stability of the polymers was evaluated using thermogravimetric and differential thermal analysis (TGA/DTA), performed using the Shimadzu DTG-60H. In this case samples of about 4.0 mg were placed in the platinum sample holder and the runs were performed in the range of 25-600ºC, with a heating rate of 10ºC/min under 50 mL/min of nitrogen atmosphere.
The kinetics for most of the cases of polymer thermal degradation are described as a single-step process by the rate equation:
where α is the conversion (α = (mi ‒ mT)/(mi‒ mf), where mT is the mass at temperature T, mi is the initial mass and mf is the final mass), Ea is the Arrhenius activation energy, A is the preexponential factor, R is the universal gas constant, T the temperature, and f(α) is the reaction mathematical model. The conversion can be estimated by thermogravimetric analysis (TGA). In the present case, the apparent activation energy for the polymer degradation was evaluated using TGA at different heating rates using Shimadzu TGA-50, under 50 mL/min of nitrogen and heating rates of 5, 10, 15 and 20ºC/min. The activation energy was estimated using the Ozawa-Flynn-Wall method for conversion ranging from 20 to 90%, using the Arrhenius plotting of the heating rate (β) and the temperature at the defined conversion (Ti). The slope of the plot ln β versus 1/Ti is Ea/R14.
The molecular weight distribution was measured using gel permeation liquid chromatography (GPC) according to ASTM D647415. The samples of polymer were dissolved in a solvent then injected onto a high temperature chromatographic column that had a solid packed substrate. This process separates the molecules of the polymer according to their size in the solution. As the separated molecules permeate from the column they are detected. The retention times are converted through molecular weights and the distributions are determined from the molecular weight concentration data. This method uses a polystyrene standard for calibration. In the present case, the equipment used was the GPC IR Polymer Char (which has three detectors: infrafred, viscometer and light scattering) using the infrared detector. The equipment uses four TOSOH GPC TSKgel® speakers. The solvent used was 1,2,4-trichlorobenzene (TCB), the solvent flow rate was 1 mL/min and the temperature 140ºC. The result of the GPC is a plot of the weight fraction as a function of the molecular weight. This plot can have several peaks on a multimodal distribution, so a peak decovolution, which is a well known mathematical procedure, is mandatory to identify the contribution of each distribution on the experimental result. In the present case the decovolution of the molecular weight distributions were performed using OriginLab software version 7.0 taking into account the presence of two to four peaks in the molecular weight distribution.
For the nanocomposites, the crystallinity of the polymers was evaluated using X-ray diffraction performed with the Shimadzu XRD-6000 diffractometer. The thermal stability was evaluated using thermogravimetric and differential thermal analysis (TGA/DTA), performed using the Shimadzu DTG-60H with a heating rate of 10ºC/min under 50 mL/min of synthetic air.
3. Results and Discussion
3.1 Characterization of the polymers
The catalyst activity of the polymerization reaction is relatively low and significantly dependent on the Al/Ti molar ratio as shown at Tables 1 and 3. The intrinsic viscosity for the polyethylene produced was 8.2 dL/g and the average molecular weight was 1.23 x 106 g/mol. This indicates that the polymer produced has a large molecular weight and is classified as high density polyethylene.
Figure 1a shows the DSC results for polyethylene obtained in laboratory (HDPE 1, 2 and 3) and samples of the commercial high molecular weight polyethylene (JV060U and BS002W). The commercial samples present a melting temperature of 131 and 133ºC, respectively, and the laboratory samples 133 and 134ºC, which confirm the production of high molecular weight polyethylene.
Thermal degradation in an inert atmosphere of commercial (BS002W and JV060U) and laboratory (HDPE) high density polyethylene: a) Differential scanning calorimetry, b) Thermo gravimetric analysis, c) Differential thermal analysis.
Figure 1b shows the termogravimetric analysis data for the samples in an inert atmosphere. It can be seen that the samples degrade in a single step and the JV060U sample has higher thermal stability. The JV060U and BS002W polymers start thermal degradation at about 400 and 350ºC and reach zero mass at about 500ºC. The laboratory sample starts degradation at about 350ºC and reaches zero mass at about 500ºC, which is the same behavior of BS002W.
The inert atmosphere differential thermal analysis (DTA) curves for the commercially produced and laboratory samples are shown in Figure 1c. Samples JV060U and BS002W showed a first endothermic event which is related to the melting temperatures at 133 and 136ºC and a second and third endothermic events at 477 and 442ºC and an exothermic event at high temperature. These events are related to the cross chain thermal decomposition including the elimination of volatile molecules of low and medium molecular weight. The laboratory sample has a melting temperature of 134ºC and has two decomposition temperatures at 443 and 477ºC, similar to those of the commercial sample BS002W.
Tables 3 and 4 shows the solid residual content of the laboratory and commercial polymer samples after the thermal degradation at 600ºC in an oxidant atmosphere. It can be seen that the laboratory polymer samples have about 2% solid residues while the commercial samples have about 0.1%. Figure 2a shows the SEM images in the secondary electron of the laboratory polymer. Figure 2b shows the solid residue after the laboratory polymer calcinations at 900ºC. It shows that this solid was sinterized and the composition is mainly aluminum oxide with traces of titanium oxide, which is the residue of the co-catalyst and catalyst used in the polymerization process.
a) SEM image in secondary electron of laboratory polymer. b) SEM image in secondary electron and EDS spectra of the polymer solid residue after thermal oxidation at 900ºC.
The DSC results (Figure 1a) also enable the evaluation of the degree of crystallization of the polymers. For the commercial samples, JV060U has a melting temperature of 131ºC and heat of fusion 194.8 J/g and BS002W has melting temperature of 133ºC and heat of fusion 167.6 J/g. For the laboratory polymers the melting temperature is 133 and 134ºC, which correspond to the melting enthalpies of 163.9 and 164.1 J/g. The degree of crystallization of the laboratory and commercial polymers are presented in Tables 3 and 4. The crystalline of the commercial polymers (JV060U and BS002W) was 61 and 53%, and the crystalline of the laboratory polymer was 52%, which is close to the value of one of the commercial samples.
Figure 3a shows the TGA curves for the thermal degradation of the laboratory polymers at an inert temperature for four different heating rates (5, 10, 15 and 20ºC/min). It was found that the thermal degradation occurs in a single step between 400 and 500ºC. The apparent activation energy for the laboratory polymers thermal degradation is shown in Figure 3b. The activation energy is from 260 to 440 kJ/mol, values higher than those reported in the literature16,17, indicating that the molecular weight for the laboratory polymers is higher than conventional high density polyethylene.
Thermal degradation kinetics on inert atmosphere of the laboratory (HDPE) high density polyethylene: a) Thermo gravimetric analysis for heating rate between 5 and 20ºC/min, b) Apparent activation energy obtained by isoconversional analysis of TGA data.
The molecular weight distribution of the commercial and laboratory polyethylene samples estimated using GPC are shown at Figure 4. It can be observed that JV060U exhibits a narrow dispersion monomodal molar weight distribution, and BS002W presents a medium dispersion bimodal molar weight distribution, both distributions with a similar average value (log M = 4.7). The laboratory polymers (HDPE 1, 2 and 3) present a broad dispersion multimodal molar weight distribution with a high average value (log M = 5.5).
Figure 5a shows the deconvolution of the molecular weight distributions of sample JV060U. It has two peaks (at log M = 4.6 and 6.0), but the second peak is very small indicating that this material is practically monomodal. Figure 5b shows the deconvolution of the molecular weight distributions of sample BS002W. There are two peaks (at log M = 4.7 and 5.8) indicating that this material is bimodal. Figure 5c shows the deconvolution of the molecular weight distribution of a laboratory polymer (HDPE). Here there are 4 peaks (at log M = 3.3, 4.8, 5.8 and 6.3) indicating a large molar weight and multimodal distribution. The predominant distributions are the second and fourth, which have average values (at log M = 4.8 and 6.3).
Decovolution of the molecular weight distribution: a) JV060U, b) BS002W, c) laboratory polymer.
Figure 6a shows the XRD pattern for the laboratory samples (HDPE 1, 2, and 3) and laboratory nanocomposites (HDPE + Nanoclay 1, 2, and 3). The presence of two characteristic crystalline peaks at 2θ = 21.7º and 2θ = 24º were observed, corresponding to the orthorhombic crystal structure of polyethylene, planes (110) and (200). A small peaks were observed for the nanocomposites at around 2θ = 35º, which is probably due to the silicate. Under the large peaks of the polyethylene there is a halo from the amorphous fraction of the polymer. There is no visible difference between the crystalline/amorphous composition in the pure polymers and the polymers in the nanocomposites. Figure 6b shows the XRD pattern for the nanoclay and the nanocomposites at low angles. The characteristic peak of the modified montmorilonite is not present at the nanocomposite samples, which indicates the exfoliation and homogenization of the nanoclay in the nanocomposites.
XRD patterns: a) High molecular weight polyethylene and nanocomposites. b) Low angle for the clay and nanocomposites.
Figure 7a shows the thermogravimetric analysis in an oxidant atmosphere for the samples of laboratory polymer (HDPE 1 and 2) and one nanocomposite sample (HDPE + Nanoclay, N1). It can be seen that the polymers curves present several different regions (I, II and III) which indicate the thermal oxidation of low, medium and high molecular weight polymers. The nanocomposite curve presents a low temperature thermal oxidation behavior, but at higher temperatures there is a reduction in the thermal oxidation. The correspondent differential thermal analysis (DTA) for oxidant atmosphere is shown in Figure 7b. For the laboratory polymers, an endothermic event (the polymer melting) and several exothermic events (thermal oxidation) can be observed. The first exothermic event (at about 250ºC) corresponds to the oxidation of volatile compounds. The second, third and fourth events (at about 400, 470 and 500ºC) corresponds to the thermal oxidation of polymers of medium and large molecular weight and the combustion of the heavy compounds (char). Quite distinct behavior for the nanocomposites can be seen, especially for temperatures above 450ºC. The peaks related to the thermal oxidation of the medium and large molecular weight polymers shift and reduce indicating that a high temperature is now necessary for the oxidation of the polymers. This improvement in the thermal stability of the polymeric matrix can be explained by the fact that the nanoclay can reduce the diffusion of oxygen and the volatile degradation products acting as a mass transport barrier.
Thermal degradation in an oxidant atmosphere of the polyethylene (HDPE) and the composite polyethylene and nanoclay (HDPE + Nanoclay): a) Thermo gravimetric analysis, b) Differential thermal analysis.
4. Conclusions
This study investigated the production of polyethylene and polyethylene-clay nanocomposite using direct solvent polymerization with a Ziegler type catalyst system (TEAL and TiCl4). Polymers and nanocomposite samples were characterized and their thermal stability investigated. The produced polymers were multimodal high density polyethylenes composed of four molecular distributions. The crystallinity of the produced polymer was about 52%. The nanocomposite presents low temperature thermal oxidation and high temperature thermal oxidation reduction. Several thermal oxidation events are noted in the polymer: oxidation of volatile compounds at 250ºC, thermal oxidation of polymers of medium and large molecular weight at 400 and 470ºC and the combustion of the heavy compounds (char) at 500ºC. The thermal oxidation of the medium and large molecular weight polymers in the nanocomposites shift and reduces indicating an improvement in the thermal stability of the polymeric matrix due to the clay mass transport barrier effect.
5. Acknowledgements
This study was supported by the Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq, Brazil) grant numbers 458098/2014-0 and 157196/2001-9. The Braskem PE2 is acknowledged for the GPC analysis and for provide samples of the commercial HDPE. Zênis Novais da Rocha from the Chemical Institute (UFBA) is acknowledged for their valuable help with the polymer and nanocomposite synthesis. The authors acknowledged for the thermal and XRD analysis performed at the laboratories: i) Catálise e Polímeros, ii) Energia e Ciência dos Materiais and iii) Pesquisa em Catálise e Materiais of the Federal University of Bahia.
6. References
- 1 Paul DR, Robeson LM. Polymer nanotechnology: nanocomposites. Polymer 2008;49(15):3187-3204.
- 2 Camargo PHC, Satyanarayana KG, Wypych F. Nanocomposites: synthesis, structure, properties and new application opportunities. Materials Research 2009;12(1):1-39.
- 3 Silva BL, Nack FC, Lepienski CM, Coelho LAF, Becker D. Influence of intercalation methods in properties of clay and carbon nanotube and high density polyethylene nanocomposites. Materials Research 2014;17(6):1628-1636.
- 4 Barbosa R, Morais DDS, Nóbrega KC, Araújo EM, Mélo TJA. Influence of processing variables on the mechanical behavior of HDPE/clay nanocomposites. Materials Research 2012;15(3):477-482.
- 5 Araújo EM, Barbosa R, Rodrigues AWB, Melo TJA, Ito EN. Processing and characterization of polyethylene/Brazilian clay nanocomposites. Materials Science and Engineering: A 2007;445-446:141-147.
- 6 Pandey JK, Reddy KR, Kumar AP, Singh RP. An overview on the degradability of polymer nanocomposites. Polymer Degradation and Stability 2005;88(2):234-250.
- 7 Jin YH, Park HJ, IM SS, Kwak SY, Kwak S. Polyethylene/clay nanocomposite by in-situ exfoliation of montmorillonite during Ziegler-Natta polymerization of ethylene. Macromolecular Rapid Communications 2002;23(2):135-140.
- 8 Ramazani A, Tavakolzadeh F, Baniasadi H. In situ polymerization of polyethylene/clay nanocomposites using a novel clay-supported Ziegler-Natta catalyst. Polymer Composites 2009;30(10):1388-1393.
- 9 Nikkhah SJ, Ramazani A, Baniasadi H, Tavakolzadeh F. Investigation of properties of polyethylene/clay nanocomposites prepared by new in situ Ziegler-Natta catalyst. Materials and Design 2009;30(7):2309-2315.
- 10 Abedi S, Abdouss M, Nekoomanesh-Haghighi M, Sharifi-Sanjani N. PE/clay nanocomposites produced via in situ polymerization by highly active clay-supported Ziegler-Natta catalyst. Polymer Bulletin 2013;70(4):1313-1325.
- 11 Haag RB, Silva JC, Abarca JRQ, Coutto Filho O, inventors. Petroleo Brasileiro - Petrobras SA, assignee. Process for preparing a Ziegler type catalytic system and process for preparing ultra high molecular weight polyethylene US patent 4983693. 1991 Aug 08.
- 12 American Society for Testing and Materials (ASTM). D4020-11 - Standard Specification for Ultra-High-Molecular-Weight Polyethylene Molding and Extrusion Materials West Conshohocken, PA: ASTM International; 2018.
- 13 Roxo G, Bittencourt B. UHMWPE molecular weight determination for viscosimetric analysis São Paulo: Technical Bulletin (UTEC) - Braskem; 2006.
- 14 Prime RB, Bair HE, Vyazovkin S, Gallagher PK, Riga A. Thermogravimetric Analysis (TGA) In: Menczel JD, Prime RB, editors. Thermal analysis of polymers: fundamentals and applications. London: John Wiley & Sons; 2009.
- 15 American Society for Testing and Materials (ASTM). D6474-99 -Standard test method for determining molecular weight distribution and molecular weight averages of polyolefins by high temperature gel permeation chromatography West Conshohocken, PA: ASTM International; 2018.
- 16 Khaghanikavkani E, Farid MM. Thermal pyrolysis of polyethylene: kinetic study. Energy Science and Technology 2011;2(1):1-10.
- 17 Peterson JD, Vyazovkin S, Wight CA. Kinetic of the thermal and thermal-oxidative degradation of polystyrene, polyethylene and poly(propylene). Macromolecular Chemistry and Physics 2001;202(6):775-784.