The translaminar dynamic fracture toughness of titanium-graphite hybrid fiber-metal laminate with thermoplastic matrix has been determined at the impact velocities of 2.25 and 5.52 m/s, within the temperature range from -196 to +180 ºC, and compared to that of conventional carbon-epoxy composite laminates. The hybrid laminate exhibits lower initiation fracture toughness than traditional unidirectional tape composites though it is tougher than conventional woven fabric laminates. Impact tests revealed that, if compared to the mechanical performance of conventional carbon-epoxy laminates, the fiber-metal laminate application must rely on its resistance to dynamic fracture propagation rather than on fracture initiation.
Dynamic fracture toughness; hybrid fiber-metal laminate; instrumented Charpy impact testing