Acessibilidade / Reportar erro

Methods for analysis of PAH and BTEX in groundwater from gas stations: a case study in Campo Grande, MS, Brazil

Two methods using headspace solid-phase microextraction and gas chromatography - mass spectrometry were developed for the determination of polycyclic aromatic hydrocarbons (PAH) and BTEX. Best results were obtained using DVB/CAR/PDMS fiber, with 10 min extraction at 25 °C and 0.15 min desorption at 260 °C (BTEX), and PDMS/DVB fiber, with 60 min extraction at 90 °C, 10% NaCl and 5 min desorption at 270 °C (PAH). LOD intervals were 3x10-2 - 5x10-2 µg L-1 (BTEX) and 1.6x10-3 - 1.4 µg L-1 (PAH). The methods were applied to forty-five groundwater samples from monitoring wells of gas stations and only benzene level exceeded the limit established by Brazilian regulations.

groundwater; aromatic hydrocarbons; HS-SPME/GC-MS/MS


Sociedade Brasileira de Química Secretaria Executiva, Av. Prof. Lineu Prestes, 748 - bloco 3 - Superior, 05508-000 São Paulo SP - Brazil, C.P. 26.037 - 05599-970, Tel.: +55 11 3032.2299, Fax: +55 11 3814.3602 - São Paulo - SP - Brazil