We present a patient with severe aortic valvular bioprosthesis dysfunction implanted for 11 years, presenting with acute pulmonary edema due to severe valvular insufficiency with severe systolic dysfunction (EF <30%) and comorbid conditions that amounted operative risk (STS score > 10). We carried out the transcatheter aortic valve implantation (Inovare® - Braile Biomedica), which was implemented successfully by transfemoral access and good patient outcomes.
Heart valve prosthesis; Aortic valve; Heart valve prosthesis implantation; Aortic valve insufficiency