Acessibilidade / Reportar erro

National Trends in Utilization and In-Hospital Outcomes of Surgical Aortic Valve Replacements in Spain, 2001-2015

Abstract

Objective:

The aims of this study were to examine the incidence and in-hospital outcomes of surgical aortic valve replacement (SAVR) and to identify factors associated with in-hospital mortality (IHM) among patients according to the type of implanted valve used in SAVR.

Methods:

We performed a retrospective study using the Spanish National Hospital Discharge Database, 2001-2015. We included patients who had SAVR listed as a procedure in their discharge report.

Results:

We identified 86,578 patients who underwent SAVR (52.78% mechanical and 47.22% bioprosthetic). Incidence of SAVR coding increased significantly from 11.95 cases per 100,000 inhabitants in 2001 to 17.92 in 2015 (P<0.001). Age and comorbidities increased over time (P<0.001). There was a significant increase in the frequency of concomitant coronary artery bypass grafting (CABG) and in the use of pacemaker implantation. The use of mechanical SAVR decreased and the use of bioprosthetic valves increased over time. IHM decreased over time (from 8.13% in 2001-05 to 5.39% in 2011-15). Patients who underwent mechanical SAVR had higher IHM than those who underwent bioprosthetic SAVR (7.44% vs. 6%; P<0.05). Higher IHM rates were associated with advanced age, female sex, comorbidities, concomitant CABG, and the use of mechanical SAVR (OR 1.67; 95% CI 1.57-1.77).

Conclusion:

The number of SAVRs performed in Spain has increased since 2001. The use of mechanical SAVR has decreased and the use of bioprosthetic valves has increased over time. IHM has decreased over time for both types of valves and despite a concomitant increase in age and comorbidities of patients during the same period.

Keywords:
Aortic Valve; Hospital Mortality; Incidence; Spain; Heart Valve Prosthesis; Coronary Artery Bypass; Pacemarker Artificial

Sociedade Brasileira de Cirurgia Cardiovascular Rua Afonso Celso, 1178 Vila Mariana, CEP: 04119-061 - São Paulo/SP Brazil, Tel +55 (11) 3849-0341, Tel +55 (11) 5096-0079 - São Paulo - SP - Brazil