The aim of this study is to develop an analogical modeling methodology for IP and resistivity. Simple geometrical cylindrical and tabular shapes were built using standard cement, quartzitic sand and graphite. The experiment was carried out with various amounts of graphite in order to measure the IP response for different model geometries. The results are discussed in terms of IP response as a function of geometry, graphite content, depth and strike of the models.
Analog modeling; IP; resistivity