ABSTRACT

Introduction:

Prednisolone causes pro-inflammatory impulses to be inhibited and anti-inflammatory signals to be promoted. As a result, it alters how the body's immune system reacts to certain diseases. The World Anti-Doping Agency, however, has banned SNP and other glucocorticosteroids. An electrochemical sensor can be developed using a gold nanocomposite, polypyrrole nanoparticles and synthesized carbon nanotubes (Au-PPy NPs@CNTs).

Objective:

Develop an electrochemical sensor to detect prednisolone. Method: Au-PPy NPs@CNTs nanocomposite was chemically synthesized with a modified glassy carbon electrode (GCE) surface.

Results:

According to SEM data, the nanocomposite was composed of amorphous Au NPs, and PPy NPs deposited in tubes strongly entangled in a CNTs network. The wide linear range and low detection limit of the Au-PPy NPs@CNTs/GCE as prednisolone sensors were attributed to the combined catalytic performance of the Au and PPy NPs@CNTs nanostructures.

Conclusion:

The results of prednisolone detection in each specimen using the amperometric method indicated good accuracy. The accuracy and precision of Au-PPy NPs@CNTs/GCE for prednisolone detection were explored in blood samples from 5 young athletes aged 20-24 years who used prednisolone tablets (RSD less than 4.25%). In addition to monitoring prednisolone concentrations in athletes’ serum, Au-PPy NPs@CNTs/GCE can be used as a reliable prednisolone sensor. Level of evidence II; Therapeutic studies - investigating treatment outcomes.

Keywords:
Biosensing Techniques; Nanoparticles; Prednisolone; Doping in Sports