Acessibilidade / Reportar erro

Influence of the change in the shape of the corneal epithelium removal in postoperative PRK visual acuity.

ABSTRACT

Objective:

To determine if the change in the shape of the corneal epithelial removal in photorefractive keratectomy (PRK), from circular to oval shape, modifies the recovery of the postoperative visual acuity (VA).

Methods:

Forty-three(43) patients subjected to bilateral simultaneous PRK were prospectively evaluated. Randomly for each patient, one eye underwent epithelial removal in circular shape and the other in oval shape. On the sixth day of postoperative period (D6) the follow items were recorded: the subjective comparative perception, informed by the patient, of the quality of vision between the eyes, the objective monocular VA and the appearance of the central corneal epithelial suture line.

Results:

With regard to subjective quality of vision perception, it was observed that 48.8% of patients did not realize the difference between the eyes, while 51.2% did (41.9% reported better quality of vision in the eye with the oval shape and 9.3% reported better vision in the eye with the circular shape). With regard to the VA (Snellen), the average in the oval shape of 0.62 was significantly higher (p < 0.001) than the circular shape of 0.53. As for the appearance of the epithelial suture line, in 64.3% of the cases there was a lower density of the suture line in the eyes submitted to the oval shape, 31.0% did not demonstrate difference and in 4.8% of eyes submitted to oval shape the suture line was denser. These results are due to the fact that in the oval shape the epithelial cells come from non-equidistant edges of the corneal periphery to the center and run across a smaller area, determining a smoother, sometimes off-center, epithelial suture line.

Conclusion:

The change in the shape of the corneal epithelial removal in photorefractive keratectomy (PRK), from circular to oval shape, determines a better recovery of the postoperative visual acuity (VA).

Keywords:
Photorefractive keratectomy; Visual acuity; Cornea; Epithelium; Excimer laser