Acessibilidade / Reportar erro

Pre-contoured superior locking plates offer poor bone fit for midshaft clavicle fracture fixation: cadaveric analysis of 4 commercially available systems

ABSTRACT

Objective:

The goal of this study is to verify how commercially available pre-contoured superior plates fit on clavicle midshaft fractures.

Methods:

100 cadaveric clavicles were evaluated by three distinct observers applying the clavicle congruence score and comparing four different 6 to 8-hole pre-contoured anatomic locking-plate systems.

Results:

the inter-observer agreement was considered moderate by the percentage agreement and fair by the Fleiss’ Kappa, with no significant differences between evaluations. Only 1 of the 8 plates presented an anatomic fit greater than 70%. Long plates (8 holes) presented a poor fit compared to short plates (6 or 7 holes).

Conclusions:

the overall evaluation showed that currently-available pre-contoured superior plate systems provide a poor fit on clavicles for midshaft fracture fixations. Long plates present a worse fit compared to short ones.

Keywords:
Bone Plates; Clavicle; Fracture Fixation, Internal

Colégio Brasileiro de Cirurgiões Rua Visconde de Silva, 52 - 3º andar, 22271- 090 Rio de Janeiro - RJ, Tel.: +55 21 2138-0659, Fax: (55 21) 2286-2595 - Rio de Janeiro - RJ - Brazil
E-mail: revista@cbc.org.br