[1313 C. Kassem, A. S. Farghaly, and B. Benmokrane, "Evaluation of flexural behavior and serviceability performance of concrete beams reinforced with FRP bars," J. Compos. Constr., vol. 5, no. 11, pp. 682–695, 2011.] |
C1-4 |
20 |
30 |
0.47 |
40.4 |
1368.0 |
114.0 |
71.20 |
71.72 |
|
1.01 |
TC |
C1-4b |
20 |
30 |
0.47 |
40.4 |
1368.0 |
114.0 |
74.58 |
80.20 |
|
1.08 |
CC |
C1-6 |
20 |
30 |
0.71 |
39.3 |
1368.0 |
114.0 |
83.13 |
83.53 |
|
1.00 |
CC |
C1-8 |
20 |
30 |
0.95 |
39.3 |
1368.0 |
114.0 |
90.39 |
92.43 |
|
1.02 |
CC |
C2-4 |
20 |
30 |
0.43 |
39.9 |
1904.0 |
112.0 |
78.75 |
69.38 |
|
0.88 |
CC |
C2-4b |
20 |
30 |
0.43 |
39.9 |
1904.0 |
112.0 |
78.18 |
76.16 |
|
0.97 |
CC |
C2-6 |
20 |
30 |
0.64 |
40.8 |
1904.0 |
112.0 |
80.89 |
82.09 |
|
1.01 |
CC |
C2-8 |
20 |
30 |
0.85 |
40.8 |
1904.0 |
112.0 |
89.39 |
91.09 |
|
1.02 |
CC |
G1-6 |
20 |
30 |
1.29 |
39.1 |
600.0 |
40.0 |
77.47 |
68.86 |
|
0.89 |
CC |
G1-8 |
20 |
30 |
1.72 |
39.1 |
600.0 |
40.0 |
86.76 |
76.77 |
|
0.88 |
CC |
G2-6 |
20 |
30 |
1.13 |
39.1 |
648.0 |
36.0 |
71.00 |
63.03 |
|
0.89 |
CC |
G2-8 |
20 |
30 |
1.51 |
39.1 |
648.0 |
36.0 |
84.54 |
70.52 |
|
0.83 |
CC |
AR-6 |
20 |
30 |
0.71 |
39.1 |
1716.0 |
52.0 |
70.85 |
61.62 |
|
0.87 |
CC |
AR-8 |
20 |
30 |
0.95 |
39.1 |
1716.0 |
52.0 |
71.75 |
69.04 |
|
0.96 |
CC |
[1414 M. Thériault and B. Benmokrane, "Effects of FRP reinforcement ratio and concrete strength on flexural behavior of concrete beams," J. Compos. Constr., vol. 2, no. 1, pp. 7–16, 1998.] |
BC4NA |
13 |
18 |
2.03 |
46.2 |
772.9 |
38.0 |
22.40 |
20.13 |
|
0.90 |
CC |
BC4NB |
13 |
18 |
2.03 |
46.2 |
772.9 |
38.0 |
20.60 |
20.13 |
|
0.98 |
CC |
BC4HA |
13 |
18 |
2.03 |
53.9 |
772.9 |
38.0 |
21.00 |
20.63 |
|
0.98 |
CC |
BC4HB |
13 |
18 |
2.03 |
53.9 |
772.9 |
38.0 |
21.40 |
20.63 |
|
0.96 |
CC |
BC2NA |
13 |
18 |
1.02 |
53.1 |
772.9 |
38.0 |
21.90 |
18.89 |
|
0.86 |
CC |
BC2NB |
13 |
18 |
1.02 |
53.1 |
772.9 |
38.0 |
20.00 |
18.89 |
|
0.94 |
CC |
BC2HA |
13 |
18 |
1.02 |
57.2 |
772.9 |
38.0 |
19.70 |
18.48 |
|
0.94 |
CC |
BC4HB |
13 |
18 |
1.02 |
57.2 |
772.9 |
38.0 |
20.60 |
18.48 |
|
0.90 |
CC |
[1515 R. Masmoudi, M. Thériault, and B. Benmokrane, "Flexural behavior of concrete beams reinforced with deformed fiber reinforced plastic reinforcing rods," ACI Struct. J., vol. 5, no. 6, pp. 665–675, 1998.] |
CB2B-1 |
20 |
30 |
0.58 |
52.0 |
779.0 |
38.0 |
57.90 |
65.04 |
|
1.12 |
TC |
CB2B-2 |
20 |
30 |
0.58 |
52.0 |
779.0 |
38.0 |
59.80 |
65.04 |
|
1.09 |
TC |
CB3B-1 |
20 |
30 |
0.87 |
52.0 |
779.0 |
38.0 |
66.00 |
79.30 |
|
1.20 |
CC |
CB3B-2 |
20 |
30 |
0.87 |
52.0 |
779.0 |
38.0 |
64.80 |
79.30 |
|
1.22 |
CC |
CB4B-1 |
20 |
30 |
1.16 |
45.0 |
779.0 |
38.0 |
75.40 |
74.63 |
|
0.99 |
CC |
CB4B-2 |
20 |
30 |
1.16 |
45.0 |
779.0 |
38.0 |
71.70 |
74.63 |
|
1.04 |
CC |
CB6B-1 |
20 |
30 |
1.74 |
45.0 |
779.0 |
38.0 |
84.80 |
87.48 |
|
1.03 |
CC |
CB6B-2 |
20 |
30 |
1.74 |
45.0 |
779.0 |
38.0 |
85.40 |
87.48 |
|
1.02 |
CC |
[1616 Ridwan and D. T. Putri, "Flexural capacity of concrete beam reinforced with GFRP bars," J. Phys. Conf. Ser., vol. 2049, no. 1, pp. 012075, 2021.] |
FB-2 |
30 |
40 |
0.22 |
30.0 |
690.0 |
41.0 |
68.94 |
62.75 |
|
0.91 |
TC |
FB-3 |
30 |
40 |
0.33 |
30.0 |
690.0 |
41.0 |
111.18 |
93.04 |
|
0.84 |
TC |
FB-4 |
30 |
40 |
0.44 |
30.0 |
690.0 |
41.0 |
125.88 |
121.91 |
|
0.97 |
TC |
FB-6 |
30 |
40 |
0.66 |
30.0 |
690.0 |
41.0 |
171.54 |
158.56 |
|
0.92 |
CC |
FB-8 |
30 |
40 |
0.88 |
30.0 |
690.0 |
41.0 |
222.60 |
178.05 |
|
0.80 |
CC |
HFB-3 |
30 |
40 |
0.33 |
50.0 |
690.0 |
41.0 |
93.24 |
94.89 |
|
1.02 |
TC |
HFB-4 |
30 |
40 |
0.44 |
50.0 |
690.0 |
41.0 |
119.04 |
124.63 |
|
1.05 |
TC |
HFB-6 |
30 |
40 |
0.66 |
60.0 |
690.2 |
41.0 |
200.46 |
185.69 |
|
0.93 |
TC |
HFB-8 |
30 |
40 |
0.88 |
50.0 |
690.0 |
41.0 |
218.04 |
241.47 |
|
1.11 |
TC |
HFB-10 |
30 |
40 |
1.11 |
50.0 |
690.0 |
41.0 |
219.36 |
265.55 |
|
1.21 |
CC |
[1717 B. Benmokrane, O. Chaallal, and R. Masmoudi, "Glass Fibre Reinforced Plastic (GFRP) rebars for concrete structures," Constr. Build. Mater., vol. 9, no. 6, pp. 353–364, 1995.] |
ISO30-2 |
20 |
30 |
0.95 |
44.0 |
688.8 |
42.0 |
80.40 |
85.18 |
|
1.06 |
CC |
KD30-1 |
20 |
30 |
0.95 |
44.0 |
640.9 |
49.0 |
50.60 |
79.79 |
|
1.58 |
CC |
KD30-2 |
20 |
30 |
0.95 |
44.0 |
640.9 |
49.0 |
63.80 |
79.79 |
|
1.25 |
CC |
KD45-1 |
20 |
45 |
0.64 |
55.0 |
640.9 |
49.0 |
106.60 |
136.16 |
|
1.28 |
TC |
KD45-2 |
20 |
45 |
0.64 |
55.0 |
640.9 |
49.0 |
113.00 |
136.16 |
|
1.20 |
TC |
ISO55-1 |
20 |
55 |
0.52 |
43.0 |
688.8 |
42.0 |
181.50 |
184.17 |
|
1.01 |
TC |
ISO55-2 |
20 |
55 |
0.52 |
43.0 |
688.8 |
42.0 |
181.50 |
184.17 |
|
1.01 |
TC |
KD55-1 |
20 |
55 |
0.52 |
43.0 |
640.9 |
49.0 |
146.90 |
171.48 |
|
1.17 |
TC |
KD55-2 |
20 |
55 |
0.52 |
43.0 |
640.9 |
49.0 |
172.50 |
171.48 |
|
0.99 |
TC |
[1818 B. Benmokrane, O. Chaallal, and R. Masmoudi, "Flexural response of concrete beams reinforced with FRP reinforcing bars," ACI Struct. J., vol. 91, no. 2, pp. 46–55, 1996.]* |
ISO2 |
20 |
30 |
0.95 |
43.0 |
688.5 |
45.0 |
80.40 |
83.26 |
|
1.04 |
CC |
ISO3 |
20 |
55 |
0.52 |
43.0 |
688.5 |
45.0 |
181.70 |
189.95 |
|
1.05 |
TC |
ISO4 |
20 |
55 |
0.52 |
43.0 |
688.5 |
45.0 |
181.70 |
189.95 |
|
1.05 |
TC |
[1919 A. F. Ashour, "Flexural and shear capacities of concrete beams reinforced with GFRP bars," Constr. Build. Mater., vol. 20, pp. 1005–1015, 2006.] |
Beam 2 |
15 |
20 |
0.19 |
27.7 |
650.0 |
38.0 |
5.89 |
5.84 |
|
0.99 |
TC |
Beam 4 |
15 |
25 |
0.15 |
27.7 |
650.0 |
38.0 |
7.85 |
7.94 |
|
1.01 |
TC |
Beam 6 |
15 |
30 |
0.13 |
27.7 |
650.0 |
38.0 |
10.79 |
9.77 |
|
0.91 |
TC |
Beam 8 |
15 |
20 |
0.19 |
50.1 |
650.0 |
38.0 |
5.89 |
5.90 |
|
1.00 |
TC |
Beam 10 |
15 |
25 |
0.15 |
50.1 |
650.0 |
38.0 |
9.48 |
8.00 |
|
0.84 |
TC |
Beam 12 |
15 |
30 |
0.25 |
50.1 |
650.0 |
38.0 |
16.75 |
19.46 |
|
1.16 |
TC |
[2020 J. R. Yost, C. H. Goodspeed, and E. R. Schmeckpeper, "Flexural performance of concrete beams reinforced with FRP grids," J. Compos. Constr., vol. 5, no. 1, pp. 18–25, 2005.]* |
1FRP1 |
38 .1 |
20.3 |
0.10 |
27.6 |
829.7 |
41.4 |
11.49 |
11.60 |
|
1.01 |
TC |
1FRP2 |
38.1 |
20.3 |
0.10 |
27.6 |
829.7 |
41.4 |
12.67 |
11.60 |
|
0.92 |
TC |
1FRP3 |
38.1 |
20.3 |
0.10 |
27.6 |
829.7 |
41.4 |
11.49 |
11.60 |
|
1.01 |
TC |
2FRP1 |
31.8 |
21.6 |
0.12 |
27.6 |
829.7 |
41.4 |
13.62 |
12.46 |
|
0.91 |
TC |
2FRP2 |
31.8 |
21.6 |
0.12 |
27.6 |
829.7 |
41.4 |
13.26 |
12.46 |
|
0.94 |
TC |
2FRP3 |
31.8 |
21.6 |
0.12 |
27.6 |
829.7 |
41.4 |
13.06 |
12.46 |
|
0.95 |
TC |
4FRP1 |
20.3 |
15.2 |
1.04 |
27.6 |
829.7 |
41.4 |
15.78 |
14.68 |
|
0.93 |
TC |
4FRP2 |
20.3 |
15.2 |
1.04 |
27.6 |
829.7 |
41.4 |
15.58 |
14.68 |
|
0.94 |
TC |
4FRP3 |
20.3 |
15.2 |
1.04 |
27.6 |
829.7 |
41.4 |
16.29 |
14.68 |
|
0.90 |
TC |
5FRP1 |
19.1 |
15.2 |
1.10 |
27.6 |
829.7 |
41.4 |
16.37 |
14.14 |
|
0.86 |
CC |
5FRP2 |
19.1 |
15.2 |
1.10 |
27.6 |
829.7 |
41.4 |
16.65 |
14.14 |
|
0.85 |
CC |
5FRP3 |
19.1 |
15.2 |
1.10 |
27.6 |
829.7 |
41.4 |
15.78 |
14.14 |
|
0.90 |
CC |
[2121 A. F. Ashour and M. N. Habeeb, "Continuous concrete beams reinforced with CFRP bars," ICE Proc. Struct. Build., vol. 161, no. 6, pp. 349–357, 2008.] |
C-S-1 |
20 |
30 |
0.75 |
26.9 |
1000.0 |
200.0 |
64.11 |
54.50 |
|
0.85 |
TC |
C-S-2 |
20 |
30 |
0.29 |
27.5 |
2000.0 |
200.0 |
44.28 |
43.68 |
|
0.99 |
TC |
C-C-3 |
20 |
30 |
0.52 |
23.6 |
2000.0 |
200.0 |
44.76 |
43.30 |
|
0.97 |
TC |
C-C-4 |
20 |
30 |
0.52 |
27.2 |
1000.0 |
200.0 |
60.66 |
54.87 |
|
0.90 |
TC |
C-C-5 |
20 |
30 |
0.75 |
28.0 |
1000.0 |
200.0 |
56.03 |
54.64 |
|
0.98 |
TC |
[2222 A. F. Ashour, and M. Family, "Tests of concrete flanged beams reinforced with CFRP bars," Mag. Concr. Res., vol. 58, no. 9, pp. 627–639, 2006.] |
T/C150-2 |
20/70 |
70/15 |
0.36 |
37.5 |
1060.0 |
200.0 |
64.89 |
76.77 |
|
1.18 |
TC |
T/C150-4 |
20/70 |
70/15 |
0.52 |
37.5 |
1060.0 |
200.0 |
145.69 |
146.89 |
|
1.01 |
TC |
T/C100-4 |
20/70 |
70/10 |
0.63 |
37.5 |
1060.0 |
200.0 |
104.63 |
123.23 |
|
1.18 |
TC |
R/C-2 |
20 |
35 |
0.47 |
40.5 |
1060.0 |
200.0 |
57.33 |
71.05 |
|
1.24 |
TC |
R/C-4 |
20 |
35 |
0.79 |
40.5 |
1060.0 |
200.0 |
124.60 |
136.60 |
|
1.10 |
TC |
[2323 S. H. Alsayed, Y. A. Al-Salloum, and T. H. Almusallam, "Performance of glass fiber reinforced plastic bars as a reinforcing material for concrete structures," Compos., Part B Eng., vol. 31, pp. 555–567, 2000.] |
II |
20 |
21 |
2.70 |
31.3 |
700.0 |
35.6 |
34.19 |
36.84 |
|
1.08 |
CC |
III |
20 |
26 |
0.98 |
31.3 |
886.0 |
43.4 |
45.13 |
47.67 |
|
1.06 |
CC |
IV |
20 |
30 |
0.95 |
40.7 |
700.0 |
35.6 |
59.19 |
69.84 |
|
1.18 |
CC |
V |
20 |
25 |
2.27 |
40.7 |
700.0 |
35.6 |
57.00 |
63.54 |
|
1.11 |
CC |
[2424 C. Barris, L. Torres, A. Turom, M. Baena, and A. Catalan, "An experimental study of the flexural behavior of GFRP RC beams and comparison with predicted models," Compos. Struct., vol. 91, pp. 286–295, 2009.] |
C-212-D1 |
14 |
19 |
0.85 |
59.8 |
1353.0 |
63.3 |
38.20 |
27.13 |
|
0.71 |
CC |
C-216-D1 |
14 |
19 |
1.51 |
56.3 |
995.0 |
64.2 |
45.06 |
34.09 |
|
0.76 |
CC |
C-316-D1 |
14 |
19 |
2.27 |
55.2 |
995.0 |
64.2 |
49.38 |
39.75 |
|
0.80 |
CC |
C-212-D2 |
16 |
19 |
0.74 |
39.6 |
1353.0 |
63.3 |
27.69 |
21.64 |
|
0.78 |
CC |
C-216-D2 |
16 |
19 |
1.32 |
61.7 |
995.0 |
64.2 |
42.15 |
29.17 |
|
0.69 |
CC |
C-316-D2 |
16 |
19 |
1.98 |
60.1 |
995.0 |
64.2 |
43.20 |
34.07 |
|
0.79 |
CC |
[2525 M. El-Mogy, A. El-Ragaby, and E. El-Salakawy, "Flexural behavior of continuous FRP-reinforced concrete beams," J. Compos. Constr., vol. 14, no. 6, pp. 669–680, 2010.] |
GS1 |
20 |
30 |
1.65 |
28.0 |
736.0 |
46.0 |
60.20 |
62.59 |
|
1.04 |
CC |
GS2 |
20 |
30 |
1.65 |
26.0 |
736.0 |
46.0 |
49.00 |
50.70 |
|
1.03 |
CC |
CS1 |
20 |
30 |
0.59 |
26.0 |
1392.0 |
116.0 |
51.80 |
58.99 |
|
1.14 |
CC |
[2626 G. Thiagarajan, "Experimental and Analytical Behavior of Carbon Fiber-based rods as Flexural Reinforcement," J. Compos. Constr., vol. 7, no. 1, pp. 64–72, 2003.]* |
B4 |
15.24 |
15.24 |
0.27 |
51.7 |
1899.9 |
140.0 |
12.60 |
13.84 |
|
1.10 |
TC |
B5 |
15.24 |
15.24 |
0.27 |
48.0 |
1899.9 |
140.0 |
10.15 |
13.76 |
|
1.36 |
TC |
B6 |
15.24 |
15.24 |
0.27 |
45.9 |
1899.9 |
140.0 |
12.87 |
13.73 |
|
1.07 |
TC |
B7 |
15.24 |
15.24 |
0.43 |
49.3 |
1899.9 |
140.0 |
17.10 |
18.49 |
|
1.08 |
CC |
B8 |
15.24 |
15.24 |
0.43 |
51.1 |
1899.9 |
140.0 |
16.92 |
18.45 |
|
1.09 |
CC |
B9 |
15.24 |
15.24 |
0.43 |
53.3 |
1899.9 |
140.0 |
16.58 |
18.21 |
|
1.10 |
CC |
B10 |
15.24 |
15.24 |
0.61 |
53.4 |
1899.9 |
140.0 |
17.85 |
20.74 |
|
1.16 |
CC |
B11 |
15.24 |
15.24 |
0.61 |
55.0 |
1899.9 |
140.0 |
17.61 |
20.59 |
|
1.17 |
CC |
B12 |
15.24 |
15.24 |
0.61 |
43.9 |
1899.9 |
140.0 |
17.51 |
19.52 |
|
1.12 |
CC |
[2727 M. A. Rashid, M. A. Mansur, and P. Paramasivam, "Behavior of aramid fiber-reinforced polymer reinforced high strength concrete beams under bending," J. Compos. Constr., vol. 9, no. 2, pp. 117–127, 2005.] |
AF2T1 |
15 |
30 |
0.35 |
42.8 |
1759.6 |
53.0 |
44.17 |
46.58 |
|
1.05 |
CC |
BF3T1 |
15 |
30 |
0.52 |
85.8 |
1759.6 |
53.0 |
59.46 |
60.81 |
|
1.02 |
CC |
CF3T1 |
15 |
30 |
0.52 |
85.6 |
1759.6 |
53.0 |
67.21 |
60.75 |
|
0.90 |
CC |
DF2T1 |
15 |
30 |
0.35 |
84.5 |
1759.6 |
53.0 |
48.06 |
50.28 |
|
1.05 |
CC |
DF3T1 |
15 |
30 |
0.52 |
84.5 |
1759.6 |
53.0 |
62.77 |
60.40 |
|
0.96 |
CC |
DF4T1 |
15 |
30 |
0.70 |
84.5 |
1759.6 |
53.0 |
60.02 |
62.06 |
|
1.03 |
CC |
DF3T2 |
15 |
30 |
0.52 |
84.5 |
1759.6 |
53.0 |
62.41 |
60.40 |
|
0.97 |
CC |
DF3T3 |
15 |
30 |
0.52 |
84.5 |
1759.6 |
53.0 |
60.80 |
60.40 |
|
0.99 |
CC |
DS4T2 |
15 |
30 |
1.79 |
84.5 |
1759.6 |
53.0 |
107.20 |
89.01 |
|
0.83 |
CC |
[2828 R. K. Kalluri, “Bending behavior of concrete T-beams reinforced with glass-fiber reinforced polymer bars,” Ph.D. dissertation, West Virginia Univ., Morgantown, 1999, 112 p.]* |
B1T1 |
15/91 |
46/7.6 |
1.07 |
38.6 |
620.0 |
40.0 |
111.85 |
106.63 |
|
0.95 |
TC |
B2T1 |
15/76 |
46/7.6 |
1.17 |
35.2 |
620.0 |
40.0 |
107.79 |
106.58 |
|
0.99 |
TC |
B3C1 |
15/46 |
45/6.4 |
4.31 |
21.4 |
620.0 |
40.0 |
203.37 |
208.13 |
|
1.02 |
CC |
B4T1 |
15/107 |
45/6.4 |
1.27 |
18.6 |
620.0 |
40.0 |
156.60 |
144.44 |
|
0.92 |
TC |
B3C2 |
15/61 |
37/6.4 |
3.73 |
21.4 |
620.0 |
40.0 |
223.71 |
198.51 |
|
0.89 |
CC |
B1T2 |
15/91 |
38/7.6 |
1.83 |
38.6 |
620.0 |
40.0 |
213.54 |
248.59 |
|
1.16 |
TC |
B2C1 |
15/76 |
38/7.6 |
2.57 |
35.2 |
620.0 |
40.0 |
244.05 |
297.66 |
|
1.22 |
CC |
B4C1 |
15/107 |
37/6.4 |
3.31 |
18.6 |
620.0 |
40.0 |
244.05 |
275.70 |
|
1.13 |
CC |
[2929 H. A. Toutanji and M. Saafi, "Flexural behavior of concrete beams reinforced with glass fiber-reinforced polymer (GFRP) bars," ACI Struct. J., vol. 97, no. 5, pp. 712–719, 2000.] |
GB1-1 |
18 |
30 |
0.47 |
35.0 |
695.0 |
40.0 |
60.00 |
44.82 |
|
0.75 |
TC |
GB1-2 |
18 |
30 |
0.47 |
35.0 |
695.0 |
40.0 |
59.00 |
44.82 |
|
0.76 |
TC |
GB2-1 |
18 |
30 |
0.71 |
35.0 |
695.0 |
40.0 |
65.00 |
60.69 |
|
0.93 |
CC |
GB2-2 |
18 |
30 |
0.71 |
35.0 |
695.0 |
40.0 |
64.30 |
60.69 |
|
0.94 |
CC |
GB3-1 |
18 |
30 |
0.94 |
35.0 |
695.0 |
40.0 |
71.00 |
63.27 |
|
0.89 |
CC |
GB3-2 |
18 |
30 |
0.94 |
35.0 |
695.0 |
40.0 |
70.50 |
63.27 |
|
0.90 |
CC |