The common practice, in construction sites of the region of Porto Alegre, to collect samples for testing, of the first portion of the concrete discharged from the truck mixer, and the lack of standardization to measure the quality of the mixer and uniformity of mixing and the importance of quality control testing of concrete, this paper aims to examine the uniformity of ready mixed concrete. To achieve the aim was collected samples at five different points along the discharge of ready mixed concrete, for 13 lots of conventional concrete. There was not the formation of a representative profile of compressive resistance as the different collection point and there was not significant variation between the collection points.
ready mixed concrete; truck mixer