Ribbed slabs have been widely used in buildings due to their many advantages, especially the decrease of concrete below the neutral line. This paper presents an experimental and computational study on ribbed slabs with wide-beam, two one-way slabs and two two-way slabs, with variable depths were tested to evaluate their resistance to punching and shear strength of slabs. Experimental and computational results showed that the wide-beam ribs connection is a critical point in the design of the slabs due to the difference in stiffness in the transition zone. Best results for the ultimate load estimates for ribs were provided by EC 2 (2004), while estimates of ACI 318 (2008) and NBR 6118 (2014) were respectively conservative and unsafe. Test results on slabs also revealed that the Brazilian alternative to analysis ribbed slabs as solid ones failed to give satisfactory results.