Abstract
Objective:
to verify the stability of vancomycin hydrochloride in antimicrobial seal solutions with and without association of heparin sodium according to temperature and association time.
Method:
an experimental study designed for the analysis of hydrogenionic potential and concentration by means of high-efficiency liquid chromatography of vancomycin hydrochloride (n=06) and vancomycin hydrochloride and heparin sodium (n=06). The solutions studied were submitted to absence of light, as well as to 22°C and 37°C. Analyses in triplicate (n=192) were performed at the initial moment (T0) and three (T3), eight (T8) and 24 hours (T24) after preparation. The data were submitted to analysis of variance (p≤0.05).
Results:
concentration of the antimicrobial at 22°C presented a reduction (T0-T8) and a subsequent increase (T24); hydrogenionic potential decreased significantly over time. At 37°C, the concentration increased up to T3 and decreased at T24, with a reduction of hydrogenionic potential up to 24 hours. Concentration of the vancomycin hydrochloride and heparin sodium solutions varied with a reduction at 22°C, accompanied by increased hydrogenionic potential. Precipitate formation was observed by visual inspection of the vancomycin hydrochloride-heparin sodium association (T3).
Conclusion:
pharmacological stability of vancomycin hydrochloride (5 mg/mL) and physical incompatibility with heparin sodium (100 IU/mL) were evidenced after three hours of association in the antimicrobial seal solutions studied.
Descriptor:
Catheter-Related Infections; Drug Stability; Infusions, Intravenous; Vancomycin; Heparin; Nursing