Acessibilidade / Reportar erro

Corrosion of galvanic couplings of Ni-Cr and Co-Cr alloys with Ti-6Al-4V in artificial saliva using electrochemical methods

Corrosão de acoplamentos galvânicos de ligas Ni-Cr e Co-Cr com Ti 6Al 4V em saliva artificial por métodos eletroquímicos

ABSTRACT

In this work, the open-circuit corrosion potentials of the alloys studied in aerated artificial saliva were determined; in the same solution, the potentiodynamic polarization curves of said alloys have been drawn. The corrosion potentials and current intensities of the galvanic coupling of the Ti-6Al-4V alloy with the Co-Cr and Ni-Cr alloys were determined using the Evans method, finding that the galvanic couples more resistant to corrosion in the electrolytic medium considered are those formed between the Ti alloy and the Co-Cr alloys; the least resistant are those formed between Ti alloy and Ni-Cr alloys. The corroded surfaces of the seven alloys considered in this work were also studied, and by EDAX the corrosion products due to the ions detached in the electrolytic medium were analyzed.

Keywords
Galvanic couplings; dental alloys; Co-Cr, Ni-Cr; corrosion

Laboratório de Hidrogênio, Coppe - Universidade Federal do Rio de Janeiro, em cooperação com a Associação Brasileira do Hidrogênio, ABH2 Av. Moniz Aragão, 207, 21941-594, Rio de Janeiro, RJ, Brasil, Tel: +55 (21) 3938-8791 - Rio de Janeiro - RJ - Brazil
E-mail: revmateria@gmail.com