Europa |
EN 15863 [4646 EUROPEAN COMMITTE FOR STANDARDIZATION. CEN EN 15863: Characterization of waste - Leaching behaviour test for basic characterization - Dynamic monolithic leaching test with periodic leachant renewal, under fixed conditions. UK. 2015.] |
Água deionizada |
8 mL/cm² |
36 dias |
Monólito Dimensões mínimas 40 mm |
Renovação da solução |
EN 15862 [4747 EUROPEAN COMMITTE FOR STANDARDIZATION. CEN TS 15862: Characterisation of waste - Compliance leaching test - One stage batch leaching test for monoliths at fixed liquid to surface area ratio (L/A) for test portions with fixed minimum dimensions. EU. 2012.] |
Água deionizada |
12 mL/cm² |
24 horas |
Monólito Dimensões mínimas 40 mm |
Agitação |
UNI EN 12457-1 [3434 EUROPEAN COMMITTE FOR STANDARDIZATION. CEN EN 12457-1: Leaching characteristics – Determination of the availability of inorganic components for leaching – Solid earthy and stony materials. UK. 2004.] |
Água deionizada |
1:2 |
24 horas |
Granular < 4 mm |
Agitação |
UNI EN 12457-2 [3535 EUROPEAN COMMITTE FOR STANDARDIZATION. CEN EN 12457-2: Leaching characteristics – Determination of the availability of inorganic components for leaching – Solid earthy and stony materials. UK. 2004.] |
Água deionizada |
1:10 |
24 horas |
Granular < 4 mm |
Agitação |
UNI EN 12457-3 [3636 EUROPEAN COMMITTE FOR STANDARDIZATION. CEN EN 12457-3: Leaching characteristics – Determination of the availability of inorganic components for leaching – Solid earthy and stony materials. UK. 2004.] |
Água deionizada |
1:2 e 1:8 |
6 e 18 horas |
Granular < 4 mm |
Agitação |
UNI EN 12457-4 [3737 EUROPEAN COMMITTE FOR STANDARDIZATION. CEN EN 12457-4: Leaching characteristics – Determination of the availability of inorganic components for leaching – Solid earthy and stony materials. UK. 2004.] |
Água deionizada |
1:10 |
24 horas |
Granular < 10 mm |
Agitação |
CEN TS 14405 [3838 EUROPEAN COMMITTE FOR STANDARDIZATION. CEN TS 14405: Characterization of waste - Leaching behaviour tests - up-flow percolation test (under specified conditions). UK. 2004.] |
Água deionizada |
1:10 |
Calculado em função do fluxo |
Granular < 4 mm |
Coluna |
NEN 7347 [3939 ENVIRONMENT AGENCY. EA NEN 7347: Leaching characteristics of solids earthy and stony building and waste materials – Leaching tests - Determination of the leaching of inorganic components from compacted granular materials. UK. 2006.] |
Água deionizada |
- |
64 dias |
Granular < 4 mm |
Renovação da solução |
NEN 7373 [4040 ENVIRONMENT AGENCY. EA NEN 7373: Leaching characteristics - Determination of the leaching of inorganic components from granular materials with a column test - Solid earthy and stony materials. UK. 2004.] |
Água deionizada |
1:0,1 e 1:10 |
Calculado em função do fluxo |
Granular e pó |
Coluna |
NEN 7375 [4848 ENVIRONMENT AGENCY. EA NEN 7375: Leaching Characteristics of Moulded or Monolithic Building and Waste Materials Determination of Leaching of Inorganic Components with the Diffusion Test. The Tank Test. UK. 2004.] |
Água deionizada |
1:5 |
64 dias |
Monólito |
Renovação da solução |
NF X31-211 [4949 ASSOCIATION FRANCAISE DE NORMALISATION. AFNOR NFX 31-211: Leaching characteristics – Determination of the availability of inorganic components for leaching – Solid earthy and stony materials. FR. 2012.] |
Água deionizada |
1:10 |
16 a 48 horas |
Monólito ou granular (10 a 20 mm) |
3 renovações da solução (agitação) |
Estados Unidos |
Método 1311 [4141 UNITED STATES ENVIRONMENTAL PROTECTION AGENCY. U.S EPA Method 1311: Toxicity characteristic leaching procedure. U.S, 1992.] |
Solução ácida pH 4,93 ± 0,05 ou pH 2,88 ± 0,05 |
1:20 |
18 horas |
Granular (≤9,5mm) |
Agitação |
Método 1312 [4242 UNITED STATES ENVIRONMENTAL PROTECTION AGENCY. U.S EPA Method 1312: Synthetic precipitation leaching procedure. U. S, 1994.] |
Solução ácida pH 4,20 ± 0,05 ou pH 5 ± 0,05 |
1:20 |
18 horas |
Granular (≤9,5mm) |
Agitação |
Método 1313 [4343 UNITED STATES ENVIRONMENTAL PROTECTION AGENCY. U.S EPA Method 1313: Liquid-solid partitioning as function of extract pH using a parallel batch extraction procedure. U.S, 2012.] |
Água com adições de HNO3 ou NaOH |
10 mL/g |
24, 48 ou 72 horas |
Granular <0,3; 2 ou 5 mm |
9 extrações (10 se o pH natural estiver fora da faixa alvo) |
Método 1314 [4444 UNITED STATES ENVIRONMENTAL PROTECTION AGENCY. U.S EPA Method 1314: Liquid-solid partitioning as a function of liquid-solid ratio for constituents in solid materials using an up-flow percolation column procedure.U. S, 2013.] |
Água ou 1 mol CaCl2
|
10 mL/g |
13 dias |
Granular <2 e 5 mm |
9 frações |
Método 1315 [5050 UNITED STATES ENVIRONMENTAL PROTECTION AGENCY. U.S EPA Method 1315: Mass transfer rates of constituents in monolithic or compacted granular materials using a semi-dynamic tank leaching procedure. U. S, 2013.] |
Água deionizada |
9 mL/cm2
|
63 dias |
Monólito: cilindro ou cubo; Dimensão mínima de 40 mm Granulado compactado: cilindro com altura mínima de 40 mm |
9 renovações da solução |
Método 1316 [4545 UNITED STATES ENVIRONMENTAL PROTECTION AGENCY. U.S EPA Method 1316: Liquid-solid partitioning as a function of liquid-solid ratio using a parallel batch extraction procedure. U. S, 2012.] |
Água deionizada |
10; 5; 2; 1; 0,5 mL/g |
24, 48 ou 72 horas |
Granular <0,3; 2 ou 5 mm |
5 extrações |
Brasil |
NBR 10.005 [2121 ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. ABNT NBR 10.005: Procedimento para obtenção de extrato lixiviado de resíduos sólidos. Rio de Janeiro: ABNT, 2004.] |
Solução ácida pH 4,93 ± 0,05 ou pH 2,88 ± 0,05 |
1:20 |
18 horas |
Granular (≤9,5mm) |
Agitação |