INTRODUCTION:

The main laboratory test for the diagnosis of coronavirus disease 2019 (COVID-19) is the reverse transcription real-time polymerase chain reaction (RT-qPCR). However, RT-qPCR is expensive because of the number of tests required. This study aimed to evaluate an alternative to the RT-qPCR approach for the detection of sudden acute respiratory syndrome coronavirus 2 (SARS-CoV-2) that is half of the total volume currently recommended by the US Centers for Disease Control and Prevention.

METHODS:

The analytical limit of detection (LoD) and the reaction efficiency using half volumes of the RT-qPCR assay were evaluated for the N1 and N2 regions using a synthetic control RNA. A panel of 76 SARS-CoV-2-positive and 26 SARS-CoV-2-negative clinical samples was evaluated to establish clinical sensitivity and specificity.

RESULTS:

The RT-qPCR assay efficiency was 105% for the half and standard reactions considering the N2 target and 84% (standard) and 101% (half) for N1. The RT-qPCR half-reaction LoD for N1 and N2 were 20 and 80 copies/µL, respectively. The clinical sensitivity and specificity were 100%. The half reaction presented a decrease of up to 5.5 cycle thresholds compared with standard RT-qPCR.

CONCLUSIONS:

The use of the RT-qPCR half-reaction proved feasible and economic for the detection of SARS-CoV-2 RNA.

Keywords:
Coronavirus; Coronavirus disease 2019; COVID-19; RT-qPCR half-reaction; SARS-CoV-2

Sociedade Brasileira de Medicina Tropical - SBMT Caixa Postal 118, 38001-970 Uberaba MG Brazil, Tel.: +55 34 3318-5255 / +55 34 3318-5636/ +55 34 3318-5287, http://rsbmt.org.br/ - Uberaba - MG - Brazil
E-mail: rsbmt@uftm.edu.br